HomeMy WebLinkAboutRenovation Floor PlanGENERAL NOTES
1. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES
/ AGENCIES HAVING JURISDICTION.
2. THE CONTRACTOR IS RESPONSIBLE FOR ALL WORK SHOWN BY THESE DOCUMENTS
AND FOR COORDINATION WITH ANY AND ALL OTHER DOCUMENTS PREPARED BY
OTHERS.
3. ALL RATED PARTITIONS AND/OR ASSEMBLIES SHALL MEET APPROPRIATE U.L.
STANDARDS AND ALL PENETRATIONS THRU RATED CONSTRUCTION SHALL CONFORM
WITH APPLICABLE RATED ASSEMBLY INSTALLATION.
4. ALL WORK REQUIRED TO BE EXECUTED BY SUBCONTRACTORS SHALL BE
PERFORMED BY COMPETENT FIRMS EXPERIENCED IN THE INSTALLATION OF THEIR
SPECIFlC WORK. EACH SUBCONTRACTOR MUST HOLD CURRENT STATE REGISTRATION
OR ST. LUCIE COUNTY/CITY OF FORT PIERCE CERTIFICATE OF COMPETENCY, AS WELL
AS OTHER LICENSES WHICH MAY BE REQUIRED BY THE GOVERNING MUNICIPALITY IN
WHICH THE PROJECT IS LOCATED.
5. BEFORE COMMENCING WORK, EACH CONTRACTOR/SUBCONTRACTOR SHALL VERIFY
MEASUREMENTS, LOCATIONS AND COORDINATE AS REQUIRED BETWEEN ALL RELATED
TRADES.
6. THE CONTRACTOR SHALL SUPPLY AND INSTALL ALL NECESSARY DEVICES AND
EQUIPMENT TO ENSURE SAFE, FULLY OPERATIONAL AND WORKABLE SYSTEMS AND
BUILDING.
7. ANY DISCREPANCIES WITH THE DRAWINGS, DIMENSIONS, CONFLICTS OR OTHERWISE,
SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND VERIFIED PRIOR
TO CONSTRUCTION.
8. GYPSUM WALLBOARD SHALL COMPLY WITH ASTM C36 AND SHALL BE 1/2"
THICK. PROVIDE MOISTURE RESISTANT GYPSUM BOARD AT WALLS BEHIND
WET AREAS.
9. THESE DRAWINGS SHOULD NOT BE SCALED TO OBTAIN DIMENSIONS. REFER TO
DIMENSIONS INDICATED. ANY DIMENSION NOT PROVIDED OR MIS -LABELED SHALL
BE VERIFIED WITH THE ARCHITECT PRIOR TO CONSTRUCTION.
REVIEWED FOR "
CODE COMPLIANCE
ST. LUCIE COUNTY
BOCC
FILE
COPY
ELECTRICAL NOTES
1. PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORS AS REQUIRED
BY NATIONAL FIRE PROTECTION ASSOCIATION AND MEETING THE REQUIREMENTS
OF ALL GOVERNING CODES.
2. PROVIDE AND INSTALL GROUND FAULT CIRCUIT-INTERUPTERS MEETING THE
REQUIREMENTS OF ALL GOVERNING CODES.
3. UNLESS OTHERWISE INDICATED, INSTALL SWITCHES AND RECEPTACLES AT THE
FOLLOWING HEIGHT ABOVE FINISH FLOOR:
SWITCHES 42"
OUTLETS 14"
TELEPHONE 14"
TELEVISION 14"
4. PROVIDE AFCI PROTECTION IN ALL BEDROOMS PER NEC 210-12B.
5. ALL ELECTRICAL WORK SHALL MEET THE REQUIREMENTS OF THE CURRENT
EDITION OF THE N.E.C.
6. ALL WORK REQUIRED TO BE EXECUTED BY SUBCONTRACTORS SHALL BE
PERFORMED BY COMPETENT FIRMS EXPERIENCED IN THE INSTALLATION OF
THEIR SPECIFIC WORK. EACH SUBCONTRACTOR MUST HOLD CURRENT STATE
REGISTRATION OR ST. LUCIE COUNTY CERTIFICATE OF COMPETENCY,
AS WELL AS OTHER LICENSES WHICH MAY BE REQUIRED BY THE GOVERNING
MUNICIPALITY IN WHICH THE PROJECT IS LOCATED.
7. BEFORE COMMENCING WORK, EACH CONTRACTOR/SUBCONTRACTOR SHALL
VERIFY MEASUREMENTS, LOCATIONS AND COORDINATE AS REQUIRED BETWEEN
ALL RELATED TRADES.
B. THE CONTRACTOR SHALL SUPPLY AND INSTALL ALL NECESSARY DEVICES AND
EQUIPMENT TO ENSURE SAFE, FULLY OPERATIONAL AND WORKABLE SYSTEMS
AND BUILDING.
9. ELECTRICAL LIGHTING FIXTURES SHALL BE AS SELECTED BY THE OWNER
APPLICABLE CODES
A. FLORIDA BUILDING CODE, SIXTH EDITION - EXISTING BUILDING, LEVEL 2 ALTERATION
B. FLORIDA BUILDING CODE, SIXTH EDITION - RESIDENTIAL RECEIVED
C. FLORIDA BUILDING CODE, SIXTH EDITION - PLUMBING MAR 12 2021
D. FLORIDA BUILDING CODE, SIXTH EDITION - MECHANICAL
Permt. in9 Department
E. FLORIDA BUILDING CODE, SIXTH EDITION - FUEL GAS Sa. was County
F. NATIONAL ELECTRIC CODE (NEC), 2014 WITH ALL AMENDMENTS & REVISIONS
G. 2017 FLORIDA FIRE PREVENTION CODE (FFPC)(NFPA-1, NFPA-101)
Don Bergman
ARCHITECTURE, LLC
P: 772-1665832
C: 772-708-0164
License No. AA 26002432
P.O. Box 13537
4362 Gator Trace Lane
Fort Pierce, Florida
34982
Heise
House
Interior
Renovation
30001 orange Avenue
Fort Pierce, FL
Se
RMA t.4`021
Consultant:
Q 2020 Don Bergman
Architecture LLC
This document, Sheet No. A-1.0
has been prepared specifically for this
Project. This document is not
suitable for use on other projects
or in other locations without the
approval and participation of
Don Bergman Architecture, LLC
AR0013560. Reproduction and/or
muse is prohibited.
Sheet Title :
Renovation Floor Plan
Scale: 1 /4'=V-0'
Revisions:
A02.16.21 SEC BLDG. DEPT.
Q2 03.10.21 SEC BLDG. DEPT.
Comm.:
Date:
21-021
12.10.20
Drawn:
Checked:
DBA
DLB
M
A-1.0
RENOVATION FLOOR PLAN
SCALE : 1/40 = V-0"
dlb
^A 4n 4 .
Of.