Loading...
HomeMy WebLinkAboutRenovation Floor PlanGENERAL NOTES 1. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES / AGENCIES HAVING JURISDICTION. 2. THE CONTRACTOR IS RESPONSIBLE FOR ALL WORK SHOWN BY THESE DOCUMENTS AND FOR COORDINATION WITH ANY AND ALL OTHER DOCUMENTS PREPARED BY OTHERS. 3. ALL RATED PARTITIONS AND/OR ASSEMBLIES SHALL MEET APPROPRIATE U.L. STANDARDS AND ALL PENETRATIONS THRU RATED CONSTRUCTION SHALL CONFORM WITH APPLICABLE RATED ASSEMBLY INSTALLATION. 4. ALL WORK REQUIRED TO BE EXECUTED BY SUBCONTRACTORS SHALL BE PERFORMED BY COMPETENT FIRMS EXPERIENCED IN THE INSTALLATION OF THEIR SPECIFlC WORK. EACH SUBCONTRACTOR MUST HOLD CURRENT STATE REGISTRATION OR ST. LUCIE COUNTY/CITY OF FORT PIERCE CERTIFICATE OF COMPETENCY, AS WELL AS OTHER LICENSES WHICH MAY BE REQUIRED BY THE GOVERNING MUNICIPALITY IN WHICH THE PROJECT IS LOCATED. 5. BEFORE COMMENCING WORK, EACH CONTRACTOR/SUBCONTRACTOR SHALL VERIFY MEASUREMENTS, LOCATIONS AND COORDINATE AS REQUIRED BETWEEN ALL RELATED TRADES. 6. THE CONTRACTOR SHALL SUPPLY AND INSTALL ALL NECESSARY DEVICES AND EQUIPMENT TO ENSURE SAFE, FULLY OPERATIONAL AND WORKABLE SYSTEMS AND BUILDING. 7. ANY DISCREPANCIES WITH THE DRAWINGS, DIMENSIONS, CONFLICTS OR OTHERWISE, SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND VERIFIED PRIOR TO CONSTRUCTION. 8. GYPSUM WALLBOARD SHALL COMPLY WITH ASTM C36 AND SHALL BE 1/2" THICK. PROVIDE MOISTURE RESISTANT GYPSUM BOARD AT WALLS BEHIND WET AREAS. 9. THESE DRAWINGS SHOULD NOT BE SCALED TO OBTAIN DIMENSIONS. REFER TO DIMENSIONS INDICATED. ANY DIMENSION NOT PROVIDED OR MIS -LABELED SHALL BE VERIFIED WITH THE ARCHITECT PRIOR TO CONSTRUCTION. REVIEWED FOR " CODE COMPLIANCE ST. LUCIE COUNTY BOCC FILE COPY ELECTRICAL NOTES 1. PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORS AS REQUIRED BY NATIONAL FIRE PROTECTION ASSOCIATION AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES. 2. PROVIDE AND INSTALL GROUND FAULT CIRCUIT-INTERUPTERS MEETING THE REQUIREMENTS OF ALL GOVERNING CODES. 3. UNLESS OTHERWISE INDICATED, INSTALL SWITCHES AND RECEPTACLES AT THE FOLLOWING HEIGHT ABOVE FINISH FLOOR: SWITCHES 42" OUTLETS 14" TELEPHONE 14" TELEVISION 14" 4. PROVIDE AFCI PROTECTION IN ALL BEDROOMS PER NEC 210-12B. 5. ALL ELECTRICAL WORK SHALL MEET THE REQUIREMENTS OF THE CURRENT EDITION OF THE N.E.C. 6. ALL WORK REQUIRED TO BE EXECUTED BY SUBCONTRACTORS SHALL BE PERFORMED BY COMPETENT FIRMS EXPERIENCED IN THE INSTALLATION OF THEIR SPECIFIC WORK. EACH SUBCONTRACTOR MUST HOLD CURRENT STATE REGISTRATION OR ST. LUCIE COUNTY CERTIFICATE OF COMPETENCY, AS WELL AS OTHER LICENSES WHICH MAY BE REQUIRED BY THE GOVERNING MUNICIPALITY IN WHICH THE PROJECT IS LOCATED. 7. BEFORE COMMENCING WORK, EACH CONTRACTOR/SUBCONTRACTOR SHALL VERIFY MEASUREMENTS, LOCATIONS AND COORDINATE AS REQUIRED BETWEEN ALL RELATED TRADES. B. THE CONTRACTOR SHALL SUPPLY AND INSTALL ALL NECESSARY DEVICES AND EQUIPMENT TO ENSURE SAFE, FULLY OPERATIONAL AND WORKABLE SYSTEMS AND BUILDING. 9. ELECTRICAL LIGHTING FIXTURES SHALL BE AS SELECTED BY THE OWNER APPLICABLE CODES A. FLORIDA BUILDING CODE, SIXTH EDITION - EXISTING BUILDING, LEVEL 2 ALTERATION B. FLORIDA BUILDING CODE, SIXTH EDITION - RESIDENTIAL RECEIVED C. FLORIDA BUILDING CODE, SIXTH EDITION - PLUMBING MAR 12 2021 D. FLORIDA BUILDING CODE, SIXTH EDITION - MECHANICAL Permt. in9 Department E. FLORIDA BUILDING CODE, SIXTH EDITION - FUEL GAS Sa. was County F. NATIONAL ELECTRIC CODE (NEC), 2014 WITH ALL AMENDMENTS & REVISIONS G. 2017 FLORIDA FIRE PREVENTION CODE (FFPC)(NFPA-1, NFPA-101) Don Bergman ARCHITECTURE, LLC P: 772-1665832 C: 772-708-0164 License No. AA 26002432 P.O. Box 13537 4362 Gator Trace Lane Fort Pierce, Florida 34982 Heise House Interior Renovation 30001 orange Avenue Fort Pierce, FL Se RMA t.4`021 Consultant: Q 2020 Don Bergman Architecture LLC This document, Sheet No. A-1.0 has been prepared specifically for this Project. This document is not suitable for use on other projects or in other locations without the approval and participation of Don Bergman Architecture, LLC AR0013560. Reproduction and/or muse is prohibited. Sheet Title : Renovation Floor Plan Scale: 1 /4'=V-0' Revisions: A02.16.21 SEC BLDG. DEPT. Q2 03.10.21 SEC BLDG. DEPT. Comm.: Date: 21-021 12.10.20 Drawn: Checked: DBA DLB M A-1.0 RENOVATION FLOOR PLAN SCALE : 1/40 = V-0" dlb ^A 4n 4 . Of.