ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET
Florida Building Code 7th Edition (2020)
Based on Section 1525 of the Florida Building Code- Building
INSTRUCTION PAGE
COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET
APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW:
Required Sections of Attachments Required
Roof System the Permit Application See List Below
Form
Low Slope Application A,B,C 1,2,3,4,5,6,7
Prescriptive BUR-RAS 150 A,B,C 2,4,5,6,7
Asphaltic Shingles A,B,D 1,2,4,5,6,7
Concrete or Clay Tile A,B,D,E 1,2,3,4,5,6,7
Metal Roofs A,B,D 1,2,3,4,5,8,7
Wood Shingles and A,B,D 1,2,4,5,6,7
Shakes
Other As Applicable 1,2,3,4,5,6,7
ATTACHMENTS REQUIRED As Applicable):
1. Fire Directory Listing Page
2. From Product Approval:
Front Page
Specific System Description
Specific System Limitations
General Limitations
Applicable Detail Drawings
3. Design Calculations per Chapter 16,or if applicable, RAS 127 or RAS 128
4. Other Component of Product Approval
5. Municipal Permit Application
6. Owners Notification for Roofing Considerations(Reroofing Only)
7, Any Required Roof Testing/Calculation Documentation
Form RooflnfoFeb21 Rev Feb 18,2021
5T. LUCI E
Section A (General Information).
Master Permit No. Process No.
Contractors Name:CMR CONSTRUCTION & ROOFING License# CCC1327587
Job Address 6840 Bronte Circle Port St. Lucie, FL 34952
ROOF CATEGORY
❑Low Slope ❑Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tiles
Asphaltic Shingles ❑Metal Panel/Shingles ❑Wood Shingles/Shakes
❑ Prescriptive BUR-RAS 150
ROOF ROOF TYPE.
❑ New roof ❑ Repair ❑ Maintenance Ede Reroofing ❑Recovering
ROOF SYSTEM INFORMATION
Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) 3,683 Total (SF) 3,683
Section B(Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include
dimensions of sections and levels,clearly identify dimensions of elevated pressure zones and location of parapets.
t
d
% IZ- 1Z t-� I I rT1 LZ V 1 -1 'AGE
}
11{�
Report
eagleview - Premium 8/28/2020
Claim: OIC20200800364
6840 Bronte Circle, Port St. Lucie, FL 34952 Report: 35978452
LENGTH DIAGRAM
Total Line Lengths: Valleys = 85 ft Flashing = 2 ft
Ridges = 67 ft Rakes = 121 ft Step flashing = 31 ft
Hips = 103 ft Eaves = 164 ft Parapets = 0 ft
12 12
26
cli
LO
14 C)
♦
------------;6
13 13 it 1 14 N
F
S
Note: This diagram contains segment lengths(rounded to the nearest whole number)over 5.0 Feet. In some cases, segment labels
have been removed for readability. Plus signs preface some numbers to avoid confusion when rotated (e.q. +6 and +9).
@ 2008-2020 Eagle View Technologies,Inc.and Pictometry International Corp.—All Rights Reserved—Protected by European Patent Application No.10162199.3—Covered by one or more of U.S.Patent Nos.8,078,436;8,145,578;8,170,940;
8,209,152;8,515,125;8,825,454;9,135,737;8,670,961;9,514,568;8,818,770;8,542,880;9,244,589;9,329,749;9,599,466.Other Patents Pending.
PAGE 4
ST. LUCIE WORKS
Section C (Low Slope Roof) Surfacing:
Fill in specific roof assembly components and identify Fastener Spacing for Anchor/Base Sheet Attachment:
manufacturer Zone 1':—" oc @ Lap, # Rows @ n oc
(If a component is not used, identify as"NA") Zone 1:—" oc @ Lap, # Rows @ "oc
System Manufacturer: one 2� " oc @ Lap, # Rows @ oc
/)Nu
one oc @ Lap, # Rows @ n oc
Product Approval No.:
r of F Hers Per Insulation Board:
Design Wind Pressures, From RAS 128 Calcul 1': e1: Zone 2: Zone 3:
Zone 1': Zone 1: Zone 2: Zone 3 rate Components Noted and Details as Applicable:
Max. Design Pressure, from the specific product approval Woodblocking, Gutter, Edge Termination, Stripping,
system: Flashing, Continuous Cleat, Cant Strip, Base Flashing,
Counterflashing,Coping, Etc. .,
Deck: Indicate: Mean Roof Height, Parapet Height, Height of Base
Type: Flashing,Component Material,Material'Thickness, Fastener
Type,Fastener Spacing or Submit Manufacturers Details that
Gauge Thickness: Comply with RAS 111 and Chapter 16..
Slope:
Anchor/Base Sheet& No. df Ply(s):
Anchor/Base Sheet Fastener/Bonding Material: FT.
Insulation Base Layer:
Base Insultation Size and Thickness: Parapet
Base Insulation Fastener/Bonding Material: Height
Top Insulation Layer:
Top Insulation Size and Thickness: FT.
Top Insulation Fastener/Bonding Material:
Mean
Base Sheet(s)& No.of Ply(s): Roof
Base Sheet Fastener/Bonding Material: Height
Ply Sheet(s)'& No. of Ply(s):
Ply Sheet Fastener/Bonding Material:
Top Ply:
Top Ply Fastener/Bonding Material:
t
ST. LUCRE WORKS
Section D (Steep Slope Roof System)
Roof System Manufacturer: OWENS CORNING
Notice of Acceptance Number:
NOA No.: 17-1211 .02
Minimum Design Wind Pressures, If Applicable(From RAS 127 or Calculations): N/A
Zone 1: Zone 2e: Zone 2n: Zone 2r: Zone 3e: Zone 3r:
Deck Type: IPLYWOOD
Roof Slope:
Type underlayment: ISelf adhered OC Weather Lock G
direct to deck
5 ' 'I2 _ Insulation: N/A
Fire Barrier: N/A
shingle-1 1/4 coil nails 6 per shingle
Ridge Ventilation? Fastener Type &Spacing: decking-2/38 8D ring shank 6'OC field
GAF Cobra Shingle Ridge Vent 14"OC on butt joints
Nail Gun version Adhesive Type: N/A
Type Cap Sheet: N/A
Mean Roof Height: 15 Roof Covering: Owens Corning Shingle
Type&Size Drip 126 GA 3 x 3
Edge:
ST. LUCIE WORKS
Section E(Tile Calculations)
For Moment based tile systems,choose either Method 1 or 2.Compare the values for Mr with the values from Mf.If the Mf values
are greater than or equal to the Mrvalues,for each area of the roof,then the tile attachment method is acceptable.
Method 1'Moment Based Tile Calculations Per RAS 12T
(Zone 1 : x _ --Mg: =Mr, Product Approval M
(Zone 2e: x I Mg: =M,• Product Approval Mf
(Zone 2n: x Jl = --Mg: =Mrb, Product Approval Mf
(Zone 2r: x. _ —Mg: =M Product Approval Mf
(Zone 3e: x _ --Mg: =Mne Product Approval Mf
(Zone 3r: x]L _ Mg. =Mr, Product Approval Mf
Method 2"Simplified Tile Calculations Per Table Below"
Required Moment of Resistance(Mr) From Table Below Product Approval Mf-
Mr required Moment Resistance*
Mean Roof Height Roof Slope 15' 20' 25' 30' 40'
2:12 34.4 36.5 38.2 39.7 42.2
3:12 32.2 34.4 AF 36MOM 37.4 39.8
4:12 .4 32J. d
35.1 37.3
5:12 30 6ktlues
32.8 34.9
6:12 2 28 .430.5 32.4
7:12 24. 25 28.2 30.0
*Must be used in conjunction a list of t e emsFor Uplift based tile systems u ethod 3. paa for F' for Fr If the F'values are greater than or
equal to the Fr values,for each area of the roof,then the tile attachment method is acceptable.
Method 3"Uplift Based Tile Calculations Per RAS 12T
(Zone 1: x L =x W:= )-W: cos r =Fr1 Product Approval F'
(Zone 2e: x L =x W:= )-W: Cos r =Fr2e Product Approval F'
(Zone 2n: x L =x W:= )-W: cos r =Fr2n Product Approval F'
(Zone 2r: x L =x W:= ) -W: cos r =Fr2r Product Approval F'
(Zone 3e: x L =x W:= )-W: cos r =Fr3e Product Approval F'
(Zone 3r: x L =x W:= ) -W: cos r =Fr3r Product Approval F'
Where to Obtain Information
Description Symbol Where to find
Design Pressure Zones 1,2e,2n,2r,3e,3r From applicable table in RAS 127 or by an engineering analysis
prepared by PE based on ASCE 7
Mean Roof Height H Job Site
Roof Slope 0 Job Site
Aerodynamic Multiplier a Product Approval
Restoring Moment due to Gravity Mg Product Approval
Attachment Resistance Mf Product Approval
Required Moment Resistance Mg Calculated
Minimum Attachment Resistance F' Product Approval
Required Uplift Resistance Fr Calculated
Average Tile Weight W Product Approval
Tile Dimensions L=length W=width Product Approval
All calculations must be submitted to the building official at the time of permit application.