Loading...
HomeMy WebLinkAboutEnergy Code10 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: SMITH RESIDENCE Builder Name: Street: LOT 1 HOLIDAY OUT Permit Office: ST LUCIE COUNTY City, State, Zip: ST LUCIE, FL, Permit Number: Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1 1. New construction or existing New (From Plans) 9. Wall Types (1885.8 sqft.) Insulation Area 2. Single family or multiple family Single family a. Concrete Block - Ext Insul, Exterior R=5.0 997.50 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Exterior Frame Wood, Adjacent R=19.0 627.33 ft2 c. - R=11.0 261.00 ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5.' Is this a worst case? No 10. Ceiling Types (1297.0 sqft.) Insulation Area a. Roof Deck (Unvdnted) R=19.0 1297.00 ft2 6. Conditioned floor area above grade (ft2) 1297 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(186.3 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Garage 6 130 a. U-Factor: Sgl, U=1.05 186.33 ft2 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 24.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC:, 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 17.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2.360 ft. 14. Hot Area Weighted Average SHGC: 0.250 water systems 8. Floor Types (1297.0 sqft.) Insulation Area a. Electric 'Tankless Cap: 1 gallonsEF:0.990 a. Slab -On -Grade Edge Insulation R=0.0 930.00 ft2 b. Conservation features b. Raised Floor R=21.0 367.00 ft2 None c. N/A R= ft2 15. Credits None Glass/Floor Area: 0.144 Total Proposed Modified Loads: 52.39 PASS Total Baseline Loads: 52.62 I hereby certify that the plans and specifications covered by Review of the plans and OEIE':S1r2A this calculation are in compliance with the Florida Energy specifications covered by this = p Code calculation indicates compliances with the Florida Energy Code.-4 F+ 1tn„ '<�• •" u O PREPAED BY: R Before construction is completed ' d DATE: 12-2-2 )2g this building will be inspected for compliance with Section 553.908 �" *' I herebycertify that this b ' din as designed, is in compliance Y 9� 9 P Florida Statutes. with the Florida Energy de. COtj OWNER/AGENT- BUILDING OFFICIAL' DATE: 7 2-- -Z Z T DATE: -'Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 12/2/2020 11:22 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: SMITH RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1297 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: LOT 1 HOLIDAY OUT Permit Office: ST LUCIE COUNTY Cross Ventilation: -No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: ST LUCIE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS i Number Name Area Volume 1 Entire House 1297 11306 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 3 131 1179 No 0 1 1 Yes Yes Yes 2 CLST 3 12 108 No 0 1 Yes Yes Yes 3 LAUNDRY RM 36 324 No 0 1 Yes Yes Yes 4 BATH 2 - 54 486 No 0 1 Yes Yes Yes 5 FOYER/LIVING AR 337 3033 No 0 1 Yes Yes Yes 6 KITCHEN 183 1647 Yes 0 1 Yes Yes Yes 7 BEDROOM 2 141 1269 No 0 1 1 Yes Yes Yes 8 WIC 23 207 No 0 1 Yes Yes Yes 9 PANTRY 13 117 No 0 1 Yes Yes Yes 10 STAIRS UP 40 320 No 0 1 Yes Yes Yes 11 M BATH 77 616 No 0 1 Yes Yes Yes 12 M TOILET 21 168 No 0 1 Yes Yes Yes 13 MASTER BEDROO '168 1344 No 0 1 1 Yes Yes Yes 14 M WIC 61 488 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area li Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation BEDROOM 3 24 ft 0 131 ftzi ____ 1 0 0 2 Slab -On -Grade Edge Insulation CLST 3 2 ft 0 12 f12 1 0 0 3 Slab -On -Grade Edge Insulation LAUNDRY RM 6 ft 0 i 36 ftz 1 0 0 4 Slab -On -Grade Edge Insulation BATH 2 9 ft 0 54 f? ____ 1 0 0 12/2/2020 11:22 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORM R405-201.7 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5 Slab -On -Grade Edge Insulation FOYER/LIVING A 23 ft 0 337 fie ---- 1 0 0 6 Slab -On -Grade Edge Insulation KITCHEN 13.3 ft 0 183 ft2 ____ 1 0 0 7 Slab -On -Grade Edge Insulation BEDROOM 2 18.8 ft 0 141 ft2 ____ 1 0 0 8 Slab -On -Grade Edge Insulation WIC 2 12.3 ft 0 23 ft2 ---- 1 0 0 9 Slab -On -Grade Edge Insulation PANTRY 2.2 ft 0 13 ft2 1 0 0 10Raised Floor STAIRS UP ____ --_- 40 ftz 21 1 0 0 11Raised Floor M BATH ____ _-__ 77 ft- 21 1 0 0 12Raised Floor M TOILET ___- ____ 21 ft2 21 1 0 0 13Raised Floor MASTER BEDRO __-- ____ I 168 ft? 21 1 0 0 14Raised Floor M WIC ____ ---- 61 f?2 21 1 0 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barrl Absor. Tested Tested Insul. (deg) 1 Hip Metal 1367 ft2 0 ft2 Light N I 0.3 No 0.9 No 19 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1297 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) BEDROOM 3 0 Blown 131 ft2 0.1 Wood 2 Under Attic (Unvented) CLST 3 0 Blown 12 ft2 0.1 Wood 3 Under Attic (Unvented) LAUNDRY RM 0 Blown 36 ft2 0.1 Wood 4 Under Attic (Unvented) BATH 2 0 Blown 54 ft2 0.1 Wood 5 Under Attic (Unvented) FOYER/LIVING A 0 Blown 337 ft2 0.1 Wood 6 Under Attic (Unvented) KITCHEN 0 Blown i 183 ft2 0.1 Wood 7 Under Attic (Unvented) BEDROOM 2 0 Blown 141 ft2 0.1 Wood 8 Under Attic (Unvented) WIC 2 0 Blown 23 ft2 0.1 Wood 9 Under Attic (Unvented) PANTRY 0 Blown 13 ft2 0.1 Wood 10 Under Attic (Unvented) STAIRS UP 0 Blown 40 ft2 0.1 Wood 11 Under Attic (Unvented) M BATH 0 Blown 77 ft2 0.1 Wood 12 Under Attic (Unvented) M TOILET 0 Blown 21 ft2 0.1 Wood 13 Under Attic (Unvented) MASTER BEDRO 0 Blown 168 ft2 0.1 Wood 14 Under Attic (Unvented) M WIC 0 Blown 61 ft2 0.1 Wood 12/2/2020 11:22 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height; Sheathing Framing Solar Below 0 1 SW Exterior Concrete Block - Ext InsiBEDROOM 3 5 10 0 9 0 li 90.0 ft2 0 0 0.3 0 2 NW Exterior Concrete Block - Ext InstBEDROOM 3 5 14 0 9 0 126.0 ft2 0 0 0.3 0 _ 3 NW Exterior Concrete Block- Ext Insul CLST 3 5 2 0 9 0 18.0 ft2 0 0 0.3 0 4 NW Exterior Concrete Block - Ext InsdIAUNDRY R 5 6 0 9 0 54.0 ft2 0 0 0.3 0 5 NW Exterior Concrete Block - Ext Insul BATH 2 5 9 0 9 0 81.0 ft2 0 0 0.3 0 6 SE Exterior Concrete Block - Ext InsflOYER/LIVIN 5 10 0 9 0 90.0 ft2 0 0 0.3 0 7 SW Exterior Concrete Block - Ext InsfAOYER/LIVIN 5 13 0 9 0 117.0 ft2 0 0 0.3 0 8 S Garage Frame - Wood STAIRS UP 11 8 0 9 0 72.0 ft2 0 0.1 0.3 0 9 E Exterior Concrete Block - Ext Insul KITCHEN 5 13 5 9 0 120.8 ft2 0 0 0.3 0 10 S Garage Frame- Wood KITCHEN 11 13 0 I 9 0 117.0 ft2 0 0.1 0.3 0 11 NE Exterior Concrete Block - Ext InstBEDROOM 2 5 10 9 9 0 1 96.8 ft2 0 0 0.3 0 12 NW Exterior Concrete Block- Ext InstBEDROOM 2 5 8 0 9 0 72.0 ft2 0 0 0.3 0 13 NE Exterior Concrete Block- Ext Insul WIC 2 5 5 5 9 0 48.8 ft2 0 0 0.3 0 14 NW Exterior Concrete Block- Ext Insul WIC 2 5 7 0 9 0 j 63.0 ft2 0 0 0.3 0 15 E Exterior Concrete Block - Ext Insul PANTRY 5 2 3 9 0 20.3 ft2 0 0 0.3 0 16 N Exterior Frame - Wood STAIRS UP 19 8 11 8 0 71.3 ft2 0 0.1 0.3 0 17 W Exterior Frame - Wood STAIRS UP 19 4 6 8 0 36.0 ft2 0 0.1 0.3 0 18 N Exterior Frame - Wood M BATH 19 11 8 8 0 93.3 ft2 0 0.1 0.3 0 19 E Exterior Frame - Wood M BATH 19 4 6 8 0 36.0 ft2 0 0.1 0.3 0 20 E Exterior Frame - Wood M TOILET 19 4 6 8 0 36.0 ft2 0 0.1 0.3 0 21 S Exterior Frame - Wood MASTER BE 19 14 0 8 0 112.0 ft2 0 0.1 0.3 0 22 W Exterior Frame - Wood MASTER BE 19 14 9 8 0 118.0 ft2 0 0.1 0.3 0 23 E Exterior Frame - Wood M W IC 19 9 5 8 0 75.3 ft2 0 0.1 0.3 0 24 S Exterior Frame - Wood M W IC 19 6 2 8 0 49.3 ft2 0 0.1 0.3 0 25 SE Garage Frame - Wood FOYER/LIVIN 11 3 0 9 0 27.0ft2 0 0.1 0.3 0 26 N Garage Frame - Wood FOYER/LIVIN 11 5 0 9 0 45.0 ft2 0 0.1 0.3 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Insulated KITCHEN None .23 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area', Depth Separation Int Shade Screening 1 NW 2 Metal Low-E Single Yes 1.05 0.25 Y 15.0 ft? 1 ft 0 in 1 ft 4 in None None 2 NW 4 Metal Low-E Single Yes 1.05 0.25 Y 8.0 ft2 1 ft 0 in 1 ft 4 in None None 3 NW • 5 Metal Low-E Single Yes 1.05 0.25 Y 4.0 ft21 1 ft 0 in 1 ft 4 in None None 4 SE 6 Metal Low-E Single Yes 1.05 0.25 Y 10.0 ft' 5 ft 0 in 1 ft 4 in None None 5 SE 6 Metal Low-E Single Yes 1.05 0.25 Y 20.0 ft? 5 ft 0 in 1 ft4 in None None 6 SW 7 Metal Low-E Single Yes 1.05 0.25 Y 30.0 ft l 1 ft 0 in 1 ft 4 in None None 7 E 9 Metal Low-E Single Yes 1.05 0.25 Y 9.0 ft2 1 ft 0 in 1 ft 4 in None None 8 NE 11 Metal Low-E Single Yes 1.05 0.25 Y 10.0 ft2, 1 ft 0 in 1 ft 4 in None None 12/2/2020 11:22 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT M WINDOWS Orientation shown is the entered, Proposed orientation. V # Wall Ornt ID Frame Panes NFRC U-Factor SHGC Imp Overhang Area Depth Separation Int Shade Screening 9 10 11 12 13 14 15 NW 12 Metal Low-E Single N 18 Metal Low-E Single E 19 Metal Low-E Single E 20 Metal Low-E Single S 21 Metal Low-E Single S 21 Metal Low-E Single W 22 Metal Low-E Single Yes Yes Yes Yes Yes Yes Yes 1.05 0.25 Y 1.05 0.25 Y 1.05 0.25 Y 1.05 0.25 Y 1.05 0.25 Y 1.05 0.25 Y 1.05 0.25 Y 15.0 ft2 1 ft 0 in 1 ft 4 in 8.0 ft2 1 ft 0 in 1 ft 4 in 4.0 ftl 1 ft 0 in 1 ft 4 in 4.0 f0 1 ft 0 in 1 ft 4 in 8.0 ft1 1 ft 0 in 1 ft 4 in 33.3 ft2 5 ft 0 in 1 ft 4 in 8.0 ft2 1 ft 0 in 1 ft 4 in None None None None None None None None None None None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter • Avg. Wall Height Exposed Wall Insulation 1 506 ft2 506 ft2 29 ft 9 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000388 1319 72.41 136.18 .139 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 117 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 16 24 kBtu/hr 720 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric Tankless Garage 0.99 1 gal 55.1 gal 120 deg I None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name System Model # Collector Model Collector # Area Storage Volume FEF None None ft2 DUCTS # ---- Supply ---- Location R-Value Area ---- Return ---- Location Area Leakage Type Air CFM 25 CFM25 Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 130 ft2 Attic 13 ft2 Default Leakage Garage (Default) c(Default) c 1 1 12/2/2020 11:22 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 I i FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat: N Ceiling Fans: Coolin Jan Heating Jan Feb Feb Mar Mar A r Apr f Ma May Jun rj Jun Jul Jul Au Au Se Sep Oct Oct X Nov Nov Dec X Dec Ventin Jan Feb Mar [X] A r [ Ma Jun [ Jul [ Aug [ Se [X] Oct [X] Nov [ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 j 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 'Cooling (WEH) AM 78 78 78 78 78 78 78', 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS i Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 6.3 BEDROOM 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY RM Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 FOYER/LIVING AR Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 PANTRY Default(8 Ibs/sq.ft. ft2 ft 0.3 STAIRS UP Default(8 Ibs/sq.ft. ft2 ft 0.3 M BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 M TOILET Default(8 Ibs/sq.ft. ft2 ft 0.3 MASTER BEDROO Default(8 Ibs/s .ft. ft2 ft 0.3 M W IC I 12/2/2020 11:22 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6