HomeMy WebLinkAboutEnergy Code10
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: SMITH RESIDENCE
Builder Name:
Street: LOT 1 HOLIDAY OUT
Permit Office: ST LUCIE COUNTY
City, State, Zip: ST LUCIE, FL,
Permit Number:
Owner:
Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1
1. New construction or existing New (From Plans)
9. Wall Types (1885.8 sqft.)
Insulation Area
2. Single family or multiple family Single family
a. Concrete Block - Ext Insul, Exterior
R=5.0 997.50 ft2
3. Number of units, if multiple family 1
b. Frame - Wood, Exterior
Frame Wood, Adjacent
R=19.0 627.33 ft2
c. -
R=11.0 261.00 ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
5.' Is this a worst case? No
10. Ceiling Types (1297.0 sqft.)
Insulation Area
a. Roof Deck (Unvdnted)
R=19.0 1297.00 ft2
6. Conditioned floor area above grade (ft2) 1297
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(186.3 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Garage
6 130
a. U-Factor: Sgl, U=1.05 186.33 ft2
SHGC: SHGC=0.25
b. U-Factor: N/A ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
24.0 SEER:16.00
c. U-Factor: N/A ft2
SHGC:,
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
17.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 2.360 ft.
14. Hot
Area Weighted Average SHGC: 0.250
water systems
8. Floor Types (1297.0 sqft.) Insulation Area
a. Electric 'Tankless
Cap: 1 gallonsEF:0.990
a. Slab -On -Grade Edge Insulation R=0.0 930.00 ft2
b. Conservation features
b. Raised Floor R=21.0 367.00 ft2
None
c. N/A R= ft2
15. Credits
None
Glass/Floor Area: 0.144 Total Proposed Modified Loads: 52.39
PASS
Total Baseline Loads: 52.62
I hereby certify that the plans and specifications covered by
Review of the plans and
OEIE':S1r2A
this calculation are in compliance with the Florida Energy
specifications covered by this
= p
Code
calculation indicates compliances
with the Florida Energy Code.-4
F+ 1tn„ '<�• •" u O
PREPAED BY:
R
Before construction is completed
'
d
DATE: 12-2-2 )2g
this building will be inspected for
compliance with Section 553.908
�"
*'
I herebycertify that this b ' din as designed, is in compliance
Y 9� 9 P
Florida Statutes.
with the Florida Energy de.
COtj
OWNER/AGENT-
BUILDING OFFICIAL'
DATE: 7 2-- -Z Z T
DATE:
-'Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
12/2/2020 11:22 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
SMITH RESIDENCE
Bedrooms: 3
Address Type:
Street Address
Building Type:
User
Conditioned Area: 1297
Lot #
Owner Name:
Total Stories: 1
Block/Subdivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
LOT 1 HOLIDAY OUT
Permit Office:
ST LUCIE COUNTY
Cross Ventilation: -No
County:
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan: No
City, State,
Zip:
ST LUCIE,
Family Type:
Single-family
FL,
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design
Daily Temp
V Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer
Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
i
Number
Name
Area
Volume
1
Entire House
1297
11306
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1
BEDROOM 3
131
1179 No
0
1
1
Yes
Yes
Yes
2
CLST 3
12
108 No
0
1
Yes
Yes
Yes
3
LAUNDRY RM
36
324 No
0
1
Yes
Yes
Yes
4
BATH 2 -
54
486 No
0
1
Yes
Yes
Yes
5
FOYER/LIVING AR
337
3033 No
0
1
Yes
Yes
Yes
6
KITCHEN
183
1647 Yes
0
1
Yes
Yes
Yes
7
BEDROOM 2
141
1269 No
0
1
1
Yes
Yes
Yes
8
WIC
23
207 No
0
1
Yes
Yes
Yes
9
PANTRY
13
117 No
0
1
Yes
Yes
Yes
10
STAIRS UP
40
320 No
0
1
Yes
Yes
Yes
11
M BATH
77
616 No
0
1
Yes
Yes
Yes
12
M TOILET
21
168 No
0
1
Yes
Yes
Yes
13
MASTER BEDROO
'168
1344 No
0
1
1
Yes
Yes
Yes
14
M WIC
61
488 No
0
1
Yes
Yes
Yes
FLOORS
#
Floor Type
Space
Perimeter Perimeter R-Value
Area
li
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulation
BEDROOM 3 24 ft 0
131 ftzi
____
1 0
0
2 Slab -On -Grade Edge Insulation
CLST 3 2 ft 0
12 f12
1 0
0
3 Slab -On -Grade Edge Insulation
LAUNDRY RM 6 ft 0
i
36 ftz
1 0
0
4 Slab -On -Grade Edge Insulation
BATH 2 9 ft 0
54 f?
____
1 0
0
12/2/2020 11:22 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6
FORM R405-201.7 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
5 Slab -On -Grade Edge Insulation
FOYER/LIVING A 23 ft
0
337 fie
----
1 0
0
6 Slab -On -Grade Edge Insulation
KITCHEN 13.3 ft
0
183 ft2
____
1 0
0
7 Slab -On -Grade Edge Insulation
BEDROOM 2 18.8 ft
0
141 ft2
____
1 0
0
8 Slab -On -Grade Edge Insulation
WIC 2 12.3 ft
0
23 ft2
----
1 0
0
9 Slab -On -Grade Edge Insulation
PANTRY 2.2 ft
0
13 ft2
1 0
0
10Raised Floor
STAIRS UP ____
--_-
40 ftz
21
1 0
0
11Raised Floor
M BATH ____
_-__
77 ft-
21
1 0
0
12Raised Floor
M TOILET ___-
____
21 ft2
21
1 0
0
13Raised Floor
MASTER BEDRO __--
____
I
168 ft?
21
1 0
0
14Raised Floor
M WIC ____
----
61 f?2
21
1 0
0
ROOF
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
# Type Materials Area
Area
Color
Barrl
Absor.
Tested
Tested Insul.
(deg)
1 Hip
Metal 1367 ft2
0 ft2
Light
N
I
0.3
No 0.9
No 19
18.4
ATTIC
V # Type
Ventilation Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic
Unvented
0
1297 ft2
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1 Under Attic (Unvented)
BEDROOM 3
0
Blown
131 ft2
0.1
Wood
2 Under Attic (Unvented)
CLST 3
0
Blown
12 ft2
0.1
Wood
3 Under Attic (Unvented)
LAUNDRY RM
0
Blown
36 ft2
0.1
Wood
4 Under Attic (Unvented)
BATH 2
0
Blown
54 ft2
0.1
Wood
5 Under Attic (Unvented)
FOYER/LIVING A
0
Blown
337 ft2
0.1
Wood
6 Under Attic (Unvented)
KITCHEN
0
Blown
i
183 ft2
0.1
Wood
7 Under Attic (Unvented)
BEDROOM 2
0
Blown
141 ft2
0.1
Wood
8 Under Attic (Unvented)
WIC 2
0
Blown
23 ft2
0.1
Wood
9 Under Attic (Unvented)
PANTRY
0
Blown
13 ft2
0.1
Wood
10 Under Attic (Unvented)
STAIRS UP
0
Blown
40 ft2
0.1
Wood
11 Under Attic (Unvented)
M BATH
0
Blown
77 ft2
0.1
Wood
12 Under Attic (Unvented)
M TOILET
0
Blown
21 ft2
0.1
Wood
13 Under Attic (Unvented)
MASTER BEDRO
0
Blown
168 ft2
0.1
Wood
14 Under Attic (Unvented)
M WIC
0
Blown
61 ft2
0.1
Wood
12/2/2020 11:22 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Space
Cavity
Width
Height;
Sheathing Framing
Solar Below
0
1
SW
Exterior
Concrete Block - Ext InsiBEDROOM 3
5
10
0
9 0 li
90.0 ft2
0
0
0.3
0
2
NW
Exterior
Concrete Block - Ext InstBEDROOM 3
5
14
0
9 0
126.0 ft2
0
0
0.3
0
_ 3
NW
Exterior
Concrete Block- Ext Insul CLST 3
5
2
0
9 0
18.0 ft2
0
0
0.3
0
4
NW
Exterior
Concrete Block - Ext InsdIAUNDRY R
5
6
0
9 0
54.0 ft2
0
0
0.3
0
5
NW
Exterior
Concrete Block - Ext Insul BATH 2
5
9
0
9 0
81.0 ft2
0
0
0.3
0
6
SE
Exterior
Concrete Block - Ext InsflOYER/LIVIN
5
10
0
9 0
90.0 ft2
0
0
0.3
0
7
SW
Exterior
Concrete Block - Ext InsfAOYER/LIVIN
5
13
0
9 0
117.0 ft2
0
0
0.3
0
8
S
Garage
Frame - Wood STAIRS UP
11
8
0
9 0
72.0 ft2
0
0.1
0.3
0
9
E
Exterior
Concrete Block - Ext Insul KITCHEN
5
13
5
9 0
120.8 ft2
0
0
0.3
0
10
S
Garage
Frame- Wood KITCHEN
11
13
0
I
9 0
117.0 ft2
0
0.1
0.3
0
11
NE
Exterior
Concrete Block - Ext InstBEDROOM 2
5
10
9
9 0 1
96.8 ft2
0
0
0.3
0
12
NW
Exterior
Concrete Block- Ext InstBEDROOM 2
5
8
0
9 0
72.0 ft2
0
0
0.3
0
13
NE
Exterior
Concrete Block- Ext Insul WIC 2
5
5
5
9 0
48.8 ft2
0
0
0.3
0
14
NW
Exterior
Concrete Block- Ext Insul WIC 2
5
7
0
9 0 j
63.0 ft2
0
0
0.3
0
15
E
Exterior
Concrete Block - Ext Insul PANTRY
5
2
3
9 0
20.3 ft2
0
0
0.3
0
16
N
Exterior
Frame - Wood STAIRS UP
19
8
11
8 0
71.3 ft2
0
0.1
0.3
0
17
W
Exterior
Frame - Wood STAIRS UP
19
4
6
8 0
36.0 ft2
0
0.1
0.3
0
18
N
Exterior
Frame - Wood M BATH
19
11
8
8 0
93.3 ft2
0
0.1
0.3
0
19
E
Exterior
Frame - Wood M BATH
19
4
6
8 0
36.0 ft2
0
0.1
0.3
0
20
E
Exterior
Frame - Wood M TOILET
19
4
6
8 0
36.0 ft2
0
0.1
0.3
0
21
S
Exterior
Frame - Wood MASTER BE
19
14
0
8 0
112.0 ft2
0
0.1
0.3
0
22
W
Exterior
Frame - Wood MASTER BE
19
14
9
8 0
118.0 ft2
0
0.1
0.3
0
23
E
Exterior
Frame - Wood M W IC
19
9
5
8 0
75.3 ft2
0
0.1
0.3
0
24
S
Exterior
Frame - Wood M W IC
19
6
2
8 0
49.3 ft2
0
0.1
0.3
0
25
SE
Garage
Frame - Wood FOYER/LIVIN
11
3
0
9 0
27.0ft2
0
0.1
0.3
0
26
N
Garage
Frame - Wood FOYER/LIVIN
11
5
0
9 0
45.0 ft2
0
0.1
0.3
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
S
Insulated KITCHEN
None
.23
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
# Omt ID
Frame Panes NFRC U-Factor
SHGC
Imp
Area',
Depth
Separation
Int Shade
Screening
1
NW 2
Metal Low-E Single Yes
1.05
0.25
Y
15.0 ft?
1 ft 0 in
1 ft 4 in
None
None
2
NW 4
Metal Low-E Single Yes
1.05
0.25
Y
8.0 ft2
1 ft 0 in
1 ft 4 in
None
None
3
NW • 5
Metal Low-E Single Yes
1.05
0.25
Y
4.0 ft21
1 ft 0 in
1 ft 4 in
None
None
4
SE 6
Metal Low-E Single Yes
1.05
0.25
Y
10.0 ft'
5 ft 0 in
1 ft 4 in
None
None
5
SE 6
Metal Low-E Single Yes
1.05
0.25
Y
20.0 ft?
5 ft 0 in
1 ft4 in
None
None
6
SW 7
Metal Low-E Single Yes
1.05
0.25
Y
30.0 ft l
1 ft 0 in
1 ft 4 in
None
None
7
E 9
Metal Low-E Single Yes
1.05
0.25
Y
9.0 ft2
1 ft 0 in
1 ft 4 in
None
None
8
NE 11
Metal Low-E Single Yes
1.05
0.25
Y
10.0 ft2,
1 ft 0 in
1 ft 4 in
None
None
12/2/2020 11:22 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
M
WINDOWS
Orientation shown is the entered, Proposed orientation.
V #
Wall
Ornt ID Frame Panes
NFRC
U-Factor SHGC Imp
Overhang
Area Depth Separation
Int Shade
Screening
9
10
11
12
13
14
15
NW 12 Metal Low-E Single
N 18 Metal Low-E Single
E 19 Metal Low-E Single
E 20 Metal Low-E Single
S 21 Metal Low-E Single
S 21 Metal Low-E Single
W 22 Metal Low-E Single
Yes
Yes
Yes
Yes
Yes
Yes
Yes
1.05 0.25 Y
1.05 0.25 Y
1.05 0.25 Y
1.05 0.25 Y
1.05 0.25 Y
1.05 0.25 Y
1.05 0.25 Y
15.0 ft2 1 ft 0 in 1 ft 4 in
8.0 ft2 1 ft 0 in 1 ft 4 in
4.0 ftl 1 ft 0 in 1 ft 4 in
4.0 f0 1 ft 0 in 1 ft 4 in
8.0 ft1 1 ft 0 in 1 ft 4 in
33.3 ft2 5 ft 0 in 1 ft 4 in
8.0 ft2 1 ft 0 in 1 ft 4 in
None
None
None
None
None
None
None
None
None
None
None
None
None
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter •
Avg. Wall Height Exposed Wall Insulation
1
506 ft2 506 ft2
29 ft
9 ft
11
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000388
1319 72.41 136.18 .139
7
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/
None
COP:1
117 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency
Capacity Air Flow
SHR Block
Ducts
1
Central Unit/
Split
Single SEER: 16
24 kBtu/hr 720 cfm
0.8 1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap
Use SetPnt
Conservation
1
Electric Tankless
Garage
0.99 1 gal 55.1 gal 120 deg
I
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
System Model # Collector Model
Collector
# Area
Storage
Volume
FEF
None None
ft2
DUCTS
#
---- Supply ----
Location R-Value Area
---- Return ----
Location Area Leakage Type
Air CFM 25 CFM25
Handler TOT OUT
QN RLF
HVAC #
Heat Cool
1
Attic 6 130 ft2
Attic
13 ft2 Default Leakage
Garage (Default) c(Default) c
1 1
12/2/2020 11:22 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6
I
i
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
Programable Thermostat:
N
Ceiling Fans:
Coolin Jan
Heating Jan
Feb
Feb
Mar
Mar
A r
Apr
f
Ma
May
Jun
rj Jun
Jul
Jul
Au
Au
Se
Sep
Oct
Oct X
Nov
Nov
Dec
X Dec
Ventin Jan
Feb
Mar
[X] A r
[
Ma
Jun
[ Jul
[ Aug
[
Se
[X] Oct [X]
Nov
[ Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7 j
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
'Cooling (WEH)
AM
78
78
78
78
78
78
78',
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Heating (WD)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
Heating (WEH)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
MASS
i
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
6.3
BEDROOM 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LAUNDRY RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
FOYER/LIVING AR
Default(8 Ibs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
PANTRY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
STAIRS UP
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M TOILET
Default(8 Ibs/sq.ft.
ft2
ft
0.3
MASTER BEDROO
Default(8 Ibs/s .ft.
ft2
ft
0.3
M W IC
I
12/2/2020 11:22 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6