Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Project Information
.r wrightsoft- Duct System Summary Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@/10L.COM Job: Date: Dec 02, 2020 By: For: SMITH RESIDENCE LOT 1 HOLIDAY OUT, ST LUCIE, FL1 i HeatingCooling 9 External static pressure 1.00 in H2O 1.00 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 1.00 in H2O 1.00 in H2O Supply / return available pressure 0.500 / 0.500 in H2O 0.500 / 0.500 in H2O Lowest friction rate 1.000 in/100ft 1.000 in/100ft Actual air flow 800 cfm 800 cfm Total effective length (TEL) 195 ftj Name Design (Btuh) Htg (Cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Mat[ Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH 2 h 1105 41 26 1.000 5.0 Ox 0 VIFx 28.2 135.0 st5 BEDROOM 2 h 2986 111 96 1.000 7.0 Ox0 ! VIFx 21.0 115.0 st2 BEDROOM 3 h 3146 117 97 1.000 7.0 Ox0 VIFx 39.6 155.0 st6 FOYER/LIVING AREA C 2020 88 94 1.000 7.0 Ox 0 VIFx 19.7 115.0 st2 FOYER/LIVING AREA -A C 2020 88 94 1.000 7.0 OX0 VIFx 40.2 155.0 st6 KITCHEN c 2113 71 98 1.000 7.0 Ox 0 VIFx 20.1 115.0 st2 LAUNDRY RM h 991 37 31 1.000 5.0 Ox 0 VIFx 27.7 135.0 sty M BATH C 1066 39 49 1.000 6.0 Ox0 VIFx 8.7 140.0 st3 •TOILET C 495 12 23 1.000 5.0 Ox0 VIFx 12.4 140.0 st3 • WIC C 573 25 27 1.000 5.0 Ox0 VIFx 10.9 140.0 st3 MASTER BEDROOM c 2246 104 104 1.000 7.0 Ox0 VIFx 5.2 140.0 st4 STAIRS UP c 954 19 44 1.000 6.0 Ox0 VIFx 6.1 140.0 st4 WIC h 1256 47 18 1.000 4.0 Ox0 VIFx 29.7 115.0 st2 Name Trunk Type Htg (cfm) Clg (cfm) Design FR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk st3 Peak AVF 76 99 1.000 370 7.0 0 x 0 VinlFlx st1 st4 Peak AVF 123 148 1.000 424 8.0 0 x 0 VinlFlx st1 st1 Peak AVF 199 247 1.000 559 9.0 0 x 0 VinlFlx st5 Peak AVF 284 248 1.000 642 9.0 0 x 0 VinlFlx st2 st2 Peak AVF 601 553 1.000 765 12.0 0 x 0 VinlFlx st6 Peak AVF 205 191 1.000 589 8.0 0 x 0 VinlFlx st5 -�- wrightsoft" 2020-Dec-02 10:57:37 �. .� +•„ Mm� - Right -Suite® Universal 2019 19.0.08 RSU08101 /A Page 1 ...rightsoft HVACISMITH RESIDENCE- HOLIDAY OUT.rup Calc = M.18 Front Door faces: SE ti ® Project Summary Job: wrightsoft Date: Dec 02, 2020 Entire House By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE,.FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUIC For: Notes: SMITH RESIDENCE LOT 1 HOLIDAY OUT, ST LUCIE, FL1 Desi n Information Weather: Fort Pierce, FL, US Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 18413 Btuh Ducts 3038 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 21452 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 Heating Coolingg Area (ft2) 1297 1297 Volume (ft3) 11578 11578 Air changeS/hour 0.45 0.23 Equiv. AVF (cfm) 87 44 Heating Equipment Summary Make Trade Model AHRI ref Efficiency 100 EFF Heating input 6.1 kW • Heating output 20905 Btuh Temperature rise 24 OF Actual air flow 800 cfm Airflow factor 0.037 cfm/Btuh Static pressure 1.00 in H2O Space thermostat Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD- 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 12887 Btuh Ducts 4397 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data in Rate/swing multiplier 0.95 Equipment sensible load 16419 Btuh Latent Cooling Equipment Load Sizing Structure 3854 Btuh Ducts 1154 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 5008 Btuh Equipment Total Load (Sen+Lat) 21427 Btuh Req. total capacity at 0.70 SHR 2.0 ton Cooling Equipment Summary Make Rheem Trade RHEEM Cond RA1624AJ 1 NA Coil RH1T2417STANJA AHRI ref 7940891 Efficiency 1 13.0 EER, 16 SEER Sensible cooling 16800 Btuh Latent cooling 7200 Btuh Total cooling 24000 Btuh Actual air flow 800 cfm Air flow factor 0.046 cfm/Btuh Static pressure 1.00 in H2O Load sensible heatiratio 0.78 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 1 _ 2020-Dec-02 10:57:30 Right -Suite® Universal 2019 19.0.08 RSU08101 Page 1 ...rightsoft HVAC\SMITH RESIDENCE- HOLIDAY OUT.rup Calc = MJ8 Front Door faces: SE + wrightsoft Right-J® Worksheet Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS AOL.COM Job: Date: Dec 02, 2020 By: 1 Room name Entire House BEDROOM 3 2 3 Exposed wall Room height 168.7 ft 8.9 ft 24.0 ft 9.0 ft heat/cool 4 5 Room dimensions Room area 1297.2 ft' 1.0 x 131.0 ft 131.0 ftz Ty Construction U-value Or HTM Area (ft') Load Area (ft-) 'Load number (Btuh/Wt-°F) (Btuh/ft') or perimeter (ft) (Btuh)I or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat (Cool Gross N/P/S Heat Cool 6 - -- Vi! -C. Vil 12E Osw -- - _ v 2 glazing, clr Iow_e __ 13A 5ocs _ ` 0 068 _ _. _ 1 050 0.125 n _n_ ne 1:90 29.40 3.50 1.18 20.99 1.91 "_165 8 145 -- -- _ 157 - -_ ._ 0 136 . -^ 2997.'� :235 475 186 _ -__ _168 260 � 0 _ 0 0 . ___0 0 _ _ __ _ 0 - 0 11 _ _G. _ 2alazinq.-clrlow-e 12E-Osw 2,giazing,_clrlow_e..._ 13A-5ocs 2 glazing, clr low-e _ _ 13A-5ocs 2 glazing, clr low-e 1 050 0.068 .__,_1.050 0.125 1.050 0125 1.050 ne. a _a- a a _ _.. se se 29.40 1.90 .___29.40,___ 3.50 29.40 3.50 29.40 _ _32.8.8 1.18 39.77. 1.91 39.77 1:91 31.63 _ _10 147 _, ._ _7. 141 9 90 10 0 140 _--_-0 132 -0 _ _ . 60 1 262 , . 266 ..__�x216 462 265 210 294 ,-315 f 165 _i.__ _292.___ 252 _ _ 358 ; 115 316 _ _ 0 _ 0 _.0 0 0 ' 0 0 0 0 _...____ 0 0 0 " 4 --.0 0 _._._0 0 __.. _.__0 0 0 --- _ _ _O 0 0 0 _.__...__0 0 0 , _ ,.. _ . 0 0 V+! 2glazing,_clrlgw.e 12E-Osw 2 glazing, clr low-e _1.050 0.068 1.050 _se_ s s __ 29.40 1.90 29.40 31.99 1.18 20.99 _ __.20 161 7 _. _. 2 121 7 __._ 591 231 216 _ ___643 144 154 --_ - _0 0 0 _- 0 ..- 0 0 --_- ---_Q 0 0 0 0 I~{G, _ _ G13A 2 giazinq, clr_ low-e _ 5ocs 1 050 0125 s _ sw 29 40 3.50 20.99 1�.91 32 207177 -_ _ _ 32 952 620 i_ -._ 680 i 339-90 ,__ _ _ 0 _ 0 90 0 315 0 172 . V�! --, _ 2.glazing,:clr_low-e_._ 12E-0sw 2 glazing, clr low-e _ ____1.050-sw_ 0.068 1.050 w w ___.29.40 1.90 29.40 �_.31.63_.. 1.18 39.77 _.;�30 154 8 4 146 0 _882..:,_...-949-__ 278 235 �, 173 i 318 _..,_0 0 0 __ __.'0_0 0 0 0 0 0 0 13A 5ocs 2 glazing, cir low-e 2 glazing, clr low-e 0.125 1.050 1.050 y nw nw nw 3.50 29.40 29.40 1.91 32.88 32.88 414 4 8 372 0 0 1302 118 235 . r 711 132 f 263 126 0 0 - 111 0 0 _ 389 0 0 212 0 0 --. C F n 2,glazing,,clr low�e. _- - 16X19-0md 22A tph _ __._._ 1.050 0.408 1 358 _nw __.29.40 1.59 38,02 32.88 1.31 0 00 _ - _ _30 1234 __.__0 1234 __882 1956 986 1688 0 __.___15 131 _ 131 ___m0 131 24 _441 208 913 ___493 _ _. 493 179 �0. - - - - 964_4242 - A. f 6 c)AED excursion 0 88 Envelope loss/gain 15741 9605 2265 1144 12 a) Infiltration 2672 732 355 97 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 2550 300 Subtotal (lines 6 to 13) 18413 12887 2620 1542 Less external load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 0 184130 0 0 12887 0 80 2701 0 25 1566 15 Duct loads 116% 34%1 3038 4397 16% 34% 446 534 Total room load Air required (cfm) 21452 800 17283 800 1 3146 1171 2101 97 /ACCA to meet all n -f-I.F wriightsoTt- �� Right -Suite® Universal 2019 19.0.08 RSU08101 ...rightsoft HVAC%SMITH RESIDENCE- HOLIDAY OUT.rup Calc = MJ8 Front Door faces: SE 2020-Dec-02 10:57:30 Page 1 .v -�- wrightsoft Right-J® Worksheet Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM Job: Date: Dec 02, 2020 By: 1 Room name CLST 3 LAUNDRYRM 2 Exposed wall 2.0 ft 6.0 ft 3 Room height 9.0 ft heaticool 9.0 ft heat/cool 4 5 Room dimensions Room area 2.0 x 6.0 ft 12.0 ftz ! 6.0 x 6.0 ft 36.0 ftz Ty Construction U-value Or- HTM Area (ft) Load Area (ftz) Load number (Btuhlftz-°F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat (Cool Gross N/P/S Heat Cool 6 1/N -- -----WG. 12E-0sw ^' ,2.91azing,_clrtow^e__.__ 13A-5ocs 0 068 _1 050 0.125 n _.n ne -1.90 _29.40 3.50 1.18 2099 1.91 -- 0 . .. 0 0 - 0 __. .,. 0 0 0 _. _ 0 0 j T 0- _ 0 0 0 _-__ 0 ^ 0 0 _._ .__.._ 0 0 4- 0 0 0 -- 0 .__ .., 0 0 11 U�sw�. 2.alazino. clr low-e- _ _ 12E 0sw _ _-_ 1 050 0 O68 - ne , a _-_ 29.40 1.90 32 88 1.1-8 _ 0 0 _ 0 0 0 0 , _ 0 0 0 _0 _ 0 - 0 _ 0 -- m'0 __ _ 0 0 Ut/ 2.glazing, cir low-e____ 13A5ocs 2 glazing, cir low e .__..__1.050 0.125 1.050 _e__ a a __29.40, 3.50 29.40 . _.39.77 1.91 39.77 .. - �_O 0 0 _.-_ ...0 0 0 _ _.__ ___0 0 0 _0 1 0 0 _.:. _a0!.__ 0 0 _._..._0 0 0 __ .. _0 0 0 _.. _ 0 0 0 13A5ocs - _ 2 glazing, cir low-e ___...0125 1.050 'se se 3,50 29.40 191 31.63 '0 0 0 0 _ O 0 _ _.__0 0 _._ _ _ _0 0 - _ _ 0 0 :_ 0 -___0 0 2glazing,clrJowe_ _. 12E-0sw 2 glazing, clr low-e ____1050 0.068 1.050 _se s s _29.40 1.90 29.40 31-99 1.18 20.99 0 0 0 _._.0 0 0 __.._e, __0 0 0 __-_. 0 0 0 ._. _.._.0 0 0 _v -0 0 0 ... __ .0 0 0 _-_..-._Q 0 0 _I-.._ -G.2.glazing,_clr,low-e.__._ yJ (^C_ 2 Alazinq, clr low-e 13A-5ocs 12E-Osw 2 glazing, clr low-e _T___1A50 0.125 __1:050 0.068 1.050 s sw _sw_.' w w . __ 29.40 3.50 _ 29.40 1.90 29.40 -_ _ 2.0 1.91 _ .31.63 1.18 39.77 ---___� 0 0 _..'--._0 0 0 _-_ _ ,0 0 .._. -- _0 0 0 .. _ . _ 0 0 _, .__0 0 0 _ _ _. __...0 ----0-_.__ 0 0 _._0 _._0'_.___.__`_0 0 0 _ 0 0 0 _-_--- _ 0 _.-_. _<._.0 0 0 _._ . _ .. 0 __._-_ .0. 0 0 13A-5ocs 2 glazing, cir low-e 2 glazing, clr low-e 0 125 1.050 1.050 nw nvv nw 3.50 29.40 29.40 1.91 32.88 32.88 18 0 0 18 0 0 63 0 0 34 0 0 54 0� 8 - 46 0 0 161 0 235 88 0 263 2.glazing,_clr.lowe -_ 1,050 _nw _29.40 _ _ 32.88 .- ____0 __---D ..----- . _.. -0 -U 0 - -_0 C _- _ 16X19.Omd 0.408 358 _ _w _ 1.59 _. 38.02 1.37 _ -000 _ 12 12 12 ....._v_._2 19 76 16 _- - -r_- _ . 36 _ 35 _ 36 - - _6 _. 57 ... -228 ------ , _0 49 _. ... W0 - -- _ _ --2 _ - - - 6 c)AED excursion 56 Envelope loss/gain 158 49 681 457 12 a) Infiltration 30 8 89 24 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 188 57 770 481 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -188 -57 80 25 14 Subtotal 0 0 851 505 151 Duct loads 16% 341/6 0 0 16% 34% 140 172 Total room load Air required (cfm) 0 0 0 0 991 37 678 31 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. -Ff&- wrOgtitsoft- At& Right -Suite® Universal 2019 19.0.08 RSU08101 2020-Dec-02 1 Page 2 ...rightsoft HVAC\SMITH RESIDENCE- HOLIDAY OUT.rup Calc = MJ8 Front Door faces: SE 9 wrightsoft Right-JO Worksheet Job: Entire House Date: Dec 02, 2020 QUICK CALCS, INC. By: 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BATH 2 FOYER/LIVING AREA 2 3 Exposed wall Room height 9.0 ft 9.0 ft heat/cool 23.0 ft 9.0 ft heat/cool 4 5 Room dimensions Room area 9.0 x 6.0 ft! 54.0 ft' 1.0 x 337.0 ft 337.0 ftz Ty Construction U-value Or HTM Area (ft�) Load Area (ftz) Load number (Btuh/ftz °F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/PIS Heat Cool Gross N/P/S Heat Cool 6 y/ 12E-0sw 2 glazing, clr low-e _ 13A-5ocs 0.068 -11_1.050 0.125 n-. n ne - 1.90 29,40 3.50 1.18 20.99 1.91 - 0 _ _ _-_ 0 0 O - - _ __ 0 0 ^._ 0 -- 3 0' ______0 - _0 0 0 __,-_ 0 0 -- - 0 _ 0 0 0 -0 0 _ - 0 _ _0 6 11 T=G- \ 2 glazinq, cir low-e_ _ 12E-0sw 1.050 0.068 _ne a 29.40 1.90 32.88 1.18 _ 0 0 _ _0 p _ _ _ 0 o p_ _,.. o. p w 0_. o _ ____ 2 glazing,_clr.low-e _._ .... -1.050 _ e. -29.40 ,39.77 _ .. _0.. .. _.. _0 _ __0 h , . . _ _.0 _-. _._ . 0 -_U' - - -0 0 V�/ �C 13A-5ocs 2 glazing, clr low-e 0.125 1.050 a a 3.50 29.40 1.91 39.77 0 0 0 0 0 0 0 0 0 0 0 0_ 0 0 0 0 Vt! 13A-5ocs 2 glazing, clr low-e 0.125 1.050 se se 3.50- 29.40 31.63 0 0 _ _ . _ O 0 _ _ 6 0 .. - _o I 0 _90 10 - 60 1 _ 210 294 . 115 316 2glazng,_clr_low-e_. -_ 12E-0sw 2 glazing, clr low-e _ - _ 1.050 0.068 1.050 . se s s 29.40, 1.90 29.40 . _ 31.99 1.16 20.99 ...._ . _0 0 0 _ _ _0 0 0 _: _.._ 0 0 0 9 0 0 --, . 20 0 0 2 0 0 _- . 591 0 0 643' 0 0 V}/ 2.glazinq, qlr low_e_ 13A-5ocs 1.050 6.125 _ s_ sw 29.40 3.50 20.99 1.91 - 0 0 _- _ ,- 0 0 0 0 _ __0 0 _ 0 117 _ 0 87 0 305 _ _ _ 0 166 2 glazing, clr low-e ___; :. _ 1.050 , sw: _29.40 ,-_ 31.63 . _ . -_ 0 .. 0 _. _ _ _ ,0 . • - ., 0 ,_ ___, 30 __ _,_ __-A _- 882 -_ - 949. V+/ �C 12E-0sw 2 glazin , clr low-e 0.068 1.050 w w_ 1.90 29.40 1.18 39.77 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 - -G 13A-5ocs - -�- 2 glazing, clr low-e 2 glazing, clr low-e 0.125 1.050 1.050 nw nw nw 3.50 29.40 29.40 1.91 32.88 32.88 81 4 0 77 0 0 - 270 118 0 , 147 132 0 0 0 0 0 0 0: 0 0 0 - 0 0 0 C _- _ - 2.glazing, clr.low,e__ 16X19 Omd - __. __. - _. __ 1.050 _ - 0.408 nw__ -.. _29.40- 1.59 _32.88 1.37 _ ._.-0 54 ,° _- - _0 54 _ 0 86 :_ 0 74 ' -._W 0 337 _ _._ '0__ 337 __0 534 _ -- _ U 461 1.358 ._ -_ - 38.02 _ _0.00 _ q _ 54 _ _ 9 - _ 342 ;_ _ _0 537 23 _- 875 - -0 6 c) AED excursion 25 -38 Envelope loss/gain 815 377 3689 2611 12 a) Infiltration 133 36 341 93 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other j 0 300 Subtotal (lines 6 to 13) 948 1 414 4030 3004 Less external load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 0 948 0 0 11 414 0 27 4057 0 8 3012 15 Duct loads 116% 34% 156 141 16% 34% 669 1028 Total room load 1105 555 4726 4040 Air required (cfm) 41 26 176 187 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. k wrightSoTtm "` -f2020-Dec-02 10:57:30 Right -Suite® Universal 2019 19.0.08 RSU08101 .4LCA ...rightsoft HVACISMITH RESIDENCE- HOLIDAY OUT.rup Calc = MJ8 Front Door faces: SE Page 3 -+ wrightsoft Right-J® Worksheet Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax: 772466-6796 Email: QUICKCALCS@AO0 .COM Job: Date: Dec 02, 2020 By: 1 Room name KrrCHEN BEDROOM 2 2 Exposed wall 13.3 ft 18.8 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 183.0 ft 183.0 ft2 1.0 x 141.4 ft 141.4 f12 Ty Construction Ll-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft22F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat (Cool Gross N/P/S Heat Cool 6 V+/ . 12EOsw 2,glazing, clrl__ _.. 13A-5ocs _--0068 . _ 1.050 0.125 -"n _n_ ne 1.90 __29.40 3.50 1.18 20.99 1.91 .__. 0 0 0 -v 0 _ _0 0 0 0 6 -�-`_ 0 40 0 __..__.O _._0 97 , 0-p _ 0 87 _'_ 0 306 -_.___--0 167 11 t-G12E-0sw . 2 glezinq,_ clr low-e , - 2 glazing, clr low.-e_ _ _ „1 O50 0.068 _ .. -1 050 _ ne„ a _.e.- 2-9 40 1.90 _._29.40 32.88 1.18 _-39.7.7... 0 0 ___-. _0 0 0 _ _. ____ 0 0 _" 0 ------ 0 0 _ _- _ _0 10 144 r0 __ . _ _0 0 0 ..._ _____'_0 282 '0 __ . _0 3.15 0 _ _ _ __._ 0 1�/ -µ--_ �--G U 13A-5ocs 2glazing,clrlow-e 13A-5ocs 2 glazing, cir low-e .2 glazing,_cir,low-e_ _ 12E Osw 2 glazing, clr low-e 0.125 1.050 0.125 1.050 . - _. 1 O50 0 068 1.050 a a 3.50 29.40 3.50 29.40 __29.40 1.90 29.40 1.91 39.77 1.91 31.63 _ 31 99'._ 1.18 20.99 121 9 - _ 0 ' 0 .. _ _. 0 0 112 0 p 0 m' - 0 0 391 265 0 0 �0 0 214 t 358 - w_.0 0 '•_____0 " 0 0 0 0 __ _0 0 _ __.._0 0 0 0 0 .. __... 0 0 ,-_ 0 "`0 0 0 0 _. _ 0 0 0 - _.-_ o 0 0 0 _- 0 0 .__ 0 0 0 se se _se_ s s IyJ-G q azinq, clr low-e-_ 2gA-5ocgs� 13A-5 n ,.cir low.e__ . _ _1 050 _-0125 1 125 s _ sw sw_,_...29.40. 29 40 3- 21.91 1 91 -.__31.63 0 0 _ _. ,. .0 0 0 __ <--_0 0 6 - w_.__0 0 0 ..!�0 6 W 0 __ .- .__.0._ 0 0 . ._.-0 0 0 ._ __0 0 0 _____.___0 -�--G_ Vh2.glazing._clr:low,-e.,_,_ 12E-Osw 2 lazin _clrlow-e_ l 5ocs 2 glazing, 2 lazm , clr low-e glazing,0 0.068 1.050 0 050 1 050 _ _1 050 w w 1.90 29.40 9.40 29.40 _--_29.40 1.18 39.77 1.91 32.88 _-_32.88' 0 0 0 0 ...____..0 0 0 0 0 ., _0 0 0 0 0 _._ __ 0 0 0 0 0 . .._- m.__0 0 0 72 0 _-___ 15 0 0 57 0 :. -0 0 0 200 0 0 0 109 0 0 nw nw _.nw" C 16X19-0md 0.408 1.59 1.37 120 120 190 164 141 141 2.24 193 _ _ __. _ _ -_-_--_ _ 38.02 _-.__' ._ ._ 0.00 m. __. .._ _ 183 _ _. - 13 .._�_ 507 _ . j_.__ _.0 _._ _ 141 _. _19 0. 6 c)AED excursion -411 8 Envelope loss/gain 1353 695 2165 1286 12 a) Infiltration 199 54 278 76 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other j 800 150 Subtotal (lines 6 to 13) 1552 1549 2443 1512 Less external load 0 0 0 0 Less transfer 0 0 0 0 14 Redistribution Subtotal 87 1638 27 1576 120 2563 37 1549 15 Duct loads 16% 34% 270 538 16% 34% 423 529 Total room load 1909 2113 2986 2078 Air required (cfm) 71 98 111 96 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. wrligF�tsoft• 2020-Dec-0210:57:30 Right -Suite@ Universal 2019 19.0.08 RSU08101 Page 4 ...rightsoft HVAC\SMITH RESIDENCE- HOLIDAY OUT.rup Calc = MJ8 Front Door faces: SE - - wrightsofV Right-M Worksheet Dat Entire House Date: Dec 02, 2020 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@40L.COM 1 Room name WIC 2 PANTRY 2 Exposed wall 12.3 ft 2.2 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 22.5 ft 22.5 ft2 1.0 x 13.2 ft 13.2 ft2 Ty Construction U-value Or HTM Area (ft-) Load Area (ft2) Load number (Btuh/Wt-°F) (Btuh/ftz) or perimeter (ft) , (Btuh) or perimeter (ft) 1(Btuh) Heat Cool Gross N/P/S Heat (Cool Gross N/P/S Heat Cool 6 ... _ 12E-Osw _ 2 glazing, clr low-e.- - 13A-5ocs 0.068 _ _,_ 1 050 0.125 n _.n ne 1.90 _29.40 3.50 . 1.18 20.99 1.91 0 _ 0 48 ... 0 _ __0 48 . _ 0 n_ t .. 0 170 ,- - 0 _.... ._ 0 93 ; 0 0 0 - - -0 _ _ _ _ 0 0 0 -,_ _. _ __0 0 0 _0 0 V)/ 11 V�/ 2 glazing.-clr low.e_ 12E-0sw 1.050 0.068 _ne, a - _ 29.40 1.90 32.88 1.18 _ _ 0 0 ,_- _ 0 0 0 b 0 0 _ 0 0 _ 0 - 0 _0 0 _ 0 0 _ .( v�/ �C - -- yJ 2.glazing,_clr low. e.. _ 13A-5ocs 2 glazin , clr low-e 13A-5ocs _-_ -- 2 glazing, clr low-e _..__ _.1.050 0.125 1.050 _. . __0.125 1.050 . _e._ a _ e se se .__ 29.40 3.50 29,40 3.50 29.40 . _.39.77 1.91 3.9.77 1.910 31.63 0 0 0 0 .. _. 0 0 0 _ __. _0 0 ___ __. 0 0 0 .. _ __.. b 0 _; _ _ ___0 0 0 0 0 ._ ... -0 20 0 0 0 '. _._._0 20 0 .. -.. - _6 0 _.0 70 0 _..__ . . 0 0 _ .. _ _.A 39 0 _ - 0 0 2 glazing, clr low-e-_ 12E-0sw - 1.050.. 0.068 Se s 29.40 1.90 ._ 31.99 1.18 _. . - 0 0 - 0 0 0- - 0 0 0 -0 0 - 0 0 - --- 0 0 - 0 0 2 glazing, cir low-e 1.050 s 29.40 20.99 0 0 0 0 0 0 0 0 _ v� 2 glazing, clr low-e, 13A 5ocs 1.050 0.125 s_ sw 29.40 3.50 20.99 1.91 0 0 0 0 0 0 0 0 _-, 0 0 0 0 0 .�G: 2 glazing,.clr_low e.._.. ._ __ 1.050 sw_ _ __ 29.40 .31.63 .. ...... 0 _,_ . _ 0 0 +-_ .._ . __0 , -_ _ . _ . 0 _ _ _. _0 . __ 0 - 0 V�/ 12E-0sw 0.068 w 1.90 1.18 0 0 0 0 0 0 0 0 2 glazing, clr low-e 1,050 w 29.40 39,77 0 0__ 0 0 0 0 0 0 VI/ 13A 5ocs 0.125 nw 3 50 1.91 63 63 :, 221 12b LL 0 - - 0 0 6 2 glazing, clr low-e 2 glazing, clr.low-e 1.050 1.050 nw nw 29.40 29.40 32.88 32.88 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 II��-GG C 2 glazing,_clr low:e _ _ 16X19-0md 22A tph__ -_. 1.050 0.408 _ -_ 1.358 _nw . - _. -. _. 29.4Q 1.59 _ m 38.02 32.88 1.37 _ _ 0.00 ._ .. 0 _ - 23 _. - . 23 _... .. _0 23 - ---12 -_ _ _ _0 36 .�..._469 _ 0 31 1__._.. _ -- 0 13 13 __ 0 13 2 _.._ 0 21 .. _ 82 0 18 ___0 6 c) AED excursion 8 -2 Envelope loss/gain 895 236 174 55 12 a) Infiltration 183 50 33 9 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 1 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 1078 287 207 64 Less external load 0 0 0 0 Less transfer 0 1 0 0 0 14 Redistribution Subtotal 0 1078 1 287 -207 0 -64 0 loads 16% 34% 178 98 16% 34% 0 0 r15Duct Total room load Air required (cfm) 147 1256 384 18 0 0 0 0 _ Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -0 wr➢ghtsoTta 2020-Dec-02 1 Right -Suite® Universal 2019 19.0.08 RSU08101 Pg ae 5 ...rightsoft HVAC1SM17H RESIDENCE- HOLIDAY OUT.rup Calc = MJ8 Front Door faces: SE 9 -+- wrightsot Right-J® Worksheet Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@,AOL.COM Job: Date: Dec 02, 2020 By: 1 Room name STAIRS UP M TOILET 2 3 Exposed wall Room height 13.3 ft 14.8 ft heat/cool 4.4 ft 8.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 40.0 ft 40.0 ft' 1.0 x 21.0 ft 21.0 ft' Ty Construction U-value Or HTM Area (ft') Load I Area (ft') Load number (Btuh/ft? °F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) _ Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V1/ I---G 12E-Osw 2 glazing, clr low-e_ -_ 13A 5ocs 0 068 _ 1 O50 0125 n n __ ne 1.90 29 40 3.50 1.18 _ 20.99 1.91 72 _ _ 0 0 72 0 0 136 - _ 0 0 85 0 0 -0 0 0 V7/ 11 _--- 2 olazinq, clr low-e _ 12E-Osw -_ 1.050 0.068 ne a _ 29.40 1.90 _32.88 1.18 _ - 0 0 _ 0 _ 0 0 0 0 0 _ _ 0 _ 36 - _ 0 32 _ 0 61 0 38 G. VU �--G V�! 2.glazing,-clr_low_e_-_ 13A-5ocs 2 lazin , clr low-e 13A5ocs 2 glazing, clr low-e -1.050 0.125 1.050 0.125 1.050 __e. a a se se __29.40 3.50 29.40 3.50 29.40 _. 39.77 1.91 39.77 1.91 31.63 __..__ _0 0 0 - - p 0 -..__.--_0 0 0 O 0• •___ _ .0 0 0 ;.__ -_-. O 0 _,.. _ _0 0 0 h - _, .6 0. ._ ____.4 0 0 _-.____ __o 0 __.___0 0 0 _...____.6 0 _ _ 108 0 0 _ .._ _ - 6 0 --,146 0 0 -- - o 0 _... _ V)/ 2 glazing,_clr low a -- 12E-Osw 2 glazing, clr low-e , ---_- 1.05029.40 0.068 1.050 s s 1.90 29.40 _ 31.99 1.18 20.99 _._ _-.. _ _0 0 0 __:-- -- _. 0 0 0 _ _ .' 0 0 0! ., _ _ 0 0 0 - 0 0 0 0 0 f 0 0 0 0 V�✓ 2 glazing,-cIr low-e 13A 5ocs 1.050 0.125 ,,, s_ sw 29.40 3.50 20 99 1.91 0 0 0 0 0 0 0 0 _ 0 0 0 0 0 LL 0 V+/ _ �G 2glazing;_clr_low-e _._ 12E-Osw 2 glazing, clr low-e 13A-5ocs 2 glazing, clr low-e 2 glazing, clr low-e _-___ 1.050 0.068 1.050 - 0.125 1.050 1.050 .sw, w w nw nw nw ___2940 1.90 29.40 ., _ 3.50 29.40 29.40 .- .31.63 1.18 39.77 1.91 32.88 32.88 ,__ - , .- 0 36 0 ._.._.-. _O 0 0 _,- ::,_ _0 36 0 . _., Q 0 0 _ -0 68 0 --0 0; 0 ..� 0 42 0 0 0 0 ... __ 0 0 0 0 0 0 ___. ___A 0 0 _ _._. ,0 0 0 _ 0 0 0 - 0 0 0 _ ..._0 0 0 0 0 0 L�_GG C _ 2 9lazin 9,_clr.low-e___ 16X19-Omd _ _ 1.050 0.408 . nw 29..40 1.59 32.88 1.37 _ _ . 0 40 0 40 . 0 63 . ' . __.-0 55 -___.0.__ 21 ____0_. 21 -0 33 29 F- - -- 22A-tph_ _ .. __ 1 358 _ 38:02 _0.00 ..30 _ . 9 .. 0 . ; . .0 w 6 c)AED excursion -19 -10 Envelope loss/gain 268 163 209 203 12 a) Infiltration 177 48 59 16 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 500 150 Subtotal (lines 6 to 13) 444 711 268 369 Less external load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 0 4440 0 0 711 0 0 268 0 0 369 15 Duct loads 116% 34% 73 I 243 16% 34% 44 126 Total room load Air required (cfm) 518 191 I 954 44 312 12 495 23 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -Fk- wrigF.tsoft® Right -Suite® Universal 2019 19.0.08 RSU08101 2020-Dec-02 1 Page 6 ...rightsoft HVACISMITH RESIDENCE- HOLIDAY OUT.rup Calc = MJS Front Door faces: SE 9 -- wrightsoft Right-J® Worksheet Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOI.com Job: Date: Dec 02, 2020 By: 1 Room name M WIC MASTER BEDROOM 2 3 Exposed wall Room height 15.6 ft 8.0 ft heat/cool 28.7 ft 8.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 61.3 ft 61.3 ft2 1.0 x 167.8 ft 167.8 ft2 Ty Construction U-value Or HTM Area (ft2) Load i Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat (Cool Gross N/P/S Heat Cool 6Vt^�__ �G 12E-0sw ` 2,glazing, clr lo" _ _ 13A-5ocs 0.068 _ 1.050 0.125 -n n ne 1.90 _29A 3.50 ' 1.1$ _ _ 2W99 1.91 - --- 0 0 '__._ 0 0 ._ __ 0 0 0 0 --- n-0 0 ____- -_0 0 0 0 _ _ _0 0 11 _- _. V)/ 2 olazing, clr low e_ _ 12E 06vv ' 1 050 0 068 ne_ a 29.40 1:90' 32.88 ' - 1.18 0 75 0 _ 75 0 - 14 . 0 -...__ 89 0 0 __ _0 0 0 _0 0 _ .. 0 _____.G 2 glazing,_clr.low:e____ __.1.050 ._1.050 __e_ _29.40 . _39.77 ___.. __ 0 .__. __. _ 0 _ . _._ - _0 J :-.0 __ _0 -. ___ ___0 _ _ ___0 _ __ _.. __0. Jl �C 13A-5ocs 2 glazing cir low-e 0.125 1.050 a a 3.50 29.40 1.91 39.77 0 0 0 0 0 0 0 l 0 0 0 0 0 0 0 0 0 - - 13A-5ocs --- - 2 glazing, clr low-e - - 0.125 1.050 se se 3.50 29.40 1.91 31.63 _ _ _. 0 0 .__ .--- 0 0 _ _0 0 0 }` 0 0 0 0 0 _. - _ _0 0 __.. _.- 0 0 2 glazing,_cl_r low-e__ _ 12E-0sw 2 glazing, clr low-e _-____ 1 0'50 0.068 1.050 se_ s s 29.40 _ 1.90 29.40 -_31.--99 1.18- 20.99 0 _ 50 0 _ 0 - 50 0 _ _, 0 - 95 0 0 59 0 .:. '_0 111 7 ... _ -__ •0 72 7 0 136 216 _ 0 _ 85 154 .2 glazinq, cir low-e_ _ _ 13A 5ocs _ _ 1.050 0 125 _ s sw 29.40 3.50 20.99 1.91 0 _0 0 0 0 0} 0 0 32 LL 0 . 32 0 952 0 680 '0 __G 2 glazin , clr low-e,.__ _ _1.050 _sw ___29:40 .., :31.63 _ . 0 ..., ._.. 0 .--., ,. - -- 0 _`- _0 ___ , , _.0 . - _.._..0 _ 0 w-_ _ _. _ _ 0 yJ 12E-0sw glazin ,_ clr low-e 0.068 1.050 w w 1.90 29.40 1.18 39.T7 0 0 0 0 0 0 0 0 118 8 110 0 210 235 130 318 13A-5ocs - -- 2 glazing, clr low-e 2 glazing, clr low-e - - 0.125 1.050 1.050 _ - nw nw nw _ 29.40 29.40 0 0 _ ._- 0 0 0 .-0 0 0 .-;.-_-_0 r 0 1 0 _____ _0 0 0 -__...-0 0 0 ---- .._.O 0 0 __---__0 0 0 32.88 32.88 2-glazing,_clr-lowe- _1.050 _nw. 29.40 .___32.88 ..:0 _.,.__.__.0 --„_ __ -_0 _fir- v 0 _._.. _,__0._-.__;___0 _____. __0 C 16X19-0md 0.408 1.59 1.37 61 61 97 84 168 168 266 230 E - 22A-t h._. _ P - _d 1 358 ._r. _38.02 -- -_ _ 0,00 - _. _ -- _3 _ 1 _ _0 _ _ _ - 0 _ _ - 0 _ _ __0 6 c)AED excursion -11 -25 Envelope loss/gain 366 221 20151 1571 12 a) Infiltration 206 56 377 103 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 150 0 Subtotal (lines 6 to 13) 572 427 2392 1675 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 572 427 2392 1675 15 Duct loads 16% 34% 94 146 16% 34% 395 571 Total room load 666 573 2787 2246 Air required (cfm) 25 27 104 104 rACCA to meet all rec -�- wrigF�tsoTt- .4CCP, _ Right -Suite@) Universal 2019 19.0.08 RSU08101 ...rightsoft HVAC\SMITH RESIDENCE- HOLIDAY OUT.rup Calc = MJ8 Front Door faces: SE 2020-Dec-02 10:57:30 Page 7 -- wrightsoft' Right-J® Worksheet Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS AOL COM Job: Date: Dec 02, 2020 By: 1 Room name M BATH 2 3 Exposed wall Room height 16.1 ft 8.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 77.0 ft 77.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area Load number (Btuh/ft22F) (Btu ft2) or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V►I 12E Osw� glazing, clr low-e ._ 13A-5ocs 0 068 1 050 0.125 n n.. ne 1.90 29;40 3.50 1 18 _ �20.99 1.91 9385 _. W _ 8 0 _ ___ _� 0 ,. 235 0 168 0 11 __ - V}✓ 2 alaznq, clr low a __ 12E-0sw 1.050 0 068 ne a 29.40 1.90 32.88 1.18 0 �36 0 32 0 61 1 0 38 2-glazing,_clr-Iow_e-___.._w _1.050 , e ._._29.40 39.77 __ ... _-A __.. _...0 108 _ .___ 146 13A-5acs 0.125 a 3.50 1.91 0 0 0 1 0 �C 2 glazing, clr low e 1 O50 a 29 40 39.77 0 0 0 0 V�! G 13A5ocs 2 glazing, clr low e 0125 1.050 se se 3.50 29.40 1 91 31.63 0 0 0 0 0 0 0_ 0 2.glazing, clrlowe_ 12E-0sw 2 glazing, clr low-e 1 050 0.068 1.050 _se,_ s s �29_40 1.90 29.40 .._ 31 99 1.18 20.99 W _ Q 0 0 0 0 0 _ ._ ,0 0 0 .__ 0' f- 0 0 G 2 glazinq, clr low-e__ 13A5ocs 2glazing,_clnlow7e_ 1.050 0.125 -:..__. 650 s: sw _sw: 29.40 3.50 .__29.40, 20 99 1.91 __31:63 0 , 0 ___ _ _._..0 0 0 _ __. ..0 0 0� ,_. 0 0 __ 0 �� yJ �G 12E-0sw 2 glazing,_clr lowe 13A 5ocs ° 0.068 1,050 0 125 w w -_.. nvd 1.90 29.40 3 50 1.18 39.77 T.91 0 0 0 0 0 6 0 0 0 0 0 0 2 glazing, clr low-e- 2 glazing, clr low-e 1.050 1.050 nw `nw 29.40 29.40 32.88 32.88 0 0 0 0 0 0 0 0 _ C 2,glazing, clrlow-e_-_ 16X19-Omd _ _1 050 0.408 „nw_ _29,40. , 32.88 0___-- 77 122 105 _ F _ . _. _ _ __.. 22A tph _ _. _ _ 1.358 38 02 0 00 0 0 e 0 _ 0_ _ _ _ 6 c) AED excursion -21 Envelope loss/gain 689 537 12 a) Infiltration 212 58 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other j 200 Subtotal (lines 6 to 13) 901 795 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 901 795 151 Duct loads 1 16% 34% 149 271 Total room load I 1050 1066 Air required (cfm) 1 1 39 49 wrYgt�tsoft^' .AtA Right -Suite® Universal 2019 19.0.08 RSU08101 ...rightsoft HVACISMITH RESIDENCE- HOLIDAY OUT.rup Calc = MJ8 Front Door faces: SE 2020-Dec-02 10:57:30 Page 8 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 I The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Garage 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 24.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1297 d) Room 6nit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 1.050 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 14. Heating system: Capacity 17.0 c) Area 7c. 186.3 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas fur' ace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 21.0 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.99 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. 19.0 e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 5.0 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 1062. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 0.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizo a heating credit f) Programmable thermostat- No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has corn lied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be i tailed (or exceeded) in this home before final inspection. Otherwise, anew EPL display card will be comple based on installed code compliant features. Builder Signature: Date: Address of New Home: LOT 1 HOLIDAY OUT City/FL Zip: ST LUCIE, FL 12/2/2020 11:23:03 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: SMITH. RESIDENCE Builder Name: Street: LOT 1 HOLIDAY OUT Permit Office: ST LUCIE COUNTY City, State, Zip: ST LUCIE, FL, Permit Number: U Owner: Jurisdiction: ST LUCIE COUNTY = Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dro g /soffit ed ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. m. terial having a thermal resistance of R-3 per inch mm1mum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim; joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottorr to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation rea�ily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Battinsulation shall be cut neatly to fit around wiring an I plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and Wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC400. 12/2/2020 11:23 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017)1 Compliant Software Page 1 of 1