HomeMy WebLinkAboutTempra Series Tankless Electric Water Heaters Specification SheetENGINEERING SPECIFICATION SHEET RF
J4*
STIEBEL ELTWON
Simply the Best
`0ter Heaters4�vp Tempra® Series TankLess Recta , ',e
For who le hous; or multiple point-oi-use
empr
��7eatures
) On -demand, continuous and unlimited
99% efficiency
supply of hot water
Cold water only line needed to
) High limit switch with manual reset
be run to lavatory
) All models equipped with exclusive
3, Seismic proof construction
Electronic Temperature Control that
> Tankless design prevents
ensures steady output temperature even
Legionella bacteria growth
with varying flow rates
No standby heat loss with
Exclusive design prevents dry firing
tankless design
3, Electronic switch activated for virtually
Easy installation 3W NPT
silent operation
7 year leakage/3 year parts warranty
connections
1) No T & P relief valve needed
Copper sheathed heating element housed
(Check local code)
YEAR
in copper cylinder
It A
Model
Voltage
Phase
kW
Amps
Circuit
Breaker(s)
Wire
Size
Temperature Rise *F
1.5 gpm 2.25 gpm
(gpm =kWX6.831 At)
3.0 gpm 4.5 gpm
Timp'ra"42/12"Plus
__24
single"
12
50
501DP
'6 AWG
54,'�
.36
172
209 V
single or unbalanced, 3-phase
9
44
'50 DP•
'&AWG
'41
27
20'
-
Tempra® 15/15 Plus
240 V
single
14.4
2 x 30
2 x 30 DP
10 AWG
65
43
33
208 V
single or unbalaficed 3-phase
10.8
2 x 26
2 x 30 DP
10 AWG
49
33
25
ra 20 us
Terp Pii20131',,24
0 V
single %
i9.2
2 x 40
2k 0, 6P,
8,AW6
88
158
44,
_208V
single or unbalanced 3-Phase
14.4
2 x.35
2 x 35 DP
8 AWG•
65
43
33
22
Tempra® 24/24 Plus
240 V
single
24
2 x 50
2 x 50 DP
6 AWG
92
73
54
37
208 V
single or unbalan, ced 3-phase
18
2 x 44
2 x 50 DP
6 AWG
82
54
41
27
T P'ra, 29129Tfus: 240 V
em
single
28;8
3 x!40.
3 x 40'DP
.'!8,AWG
92
87
66
44,
�208 V'
single or balanced 3-phase.,
21.6
3 x 35
3.x 35 DP
8 AWG
92
66
49
33,
Tempra® 36/36 Plus
240 V
-single
36
3 x 50
3 x 50 DP
6 AWG
92
92
82
55
208 V
single or balancdd 3-phase
27
3 x 44
3 x 50 DP
6 AWG
92
82
61
41
Tempra® Model
1
12 / 12 Plus 1 15 / 15 Plus
20 / 20 Plus
24 / 24 Plus
29
29 Plus
36 / 36 Plus
Part number 223420 /224196 223421 /224197
223422 /224198 223424 /224199
232885 /223425 232886 /223426
w e �g
ht
A 3,'
16.'13
8 6
-19.0/ 0 8 6
Min. flow to activate (gpm I/min) 0.37 1.4 1
0.50/1.9
0.50/ 1.9 0.50/1.9
0.77/2.9 0.77/2.9
P
in. 30-,p !.Max.,150
;Operating
psi
Dimensions (in. / cm) WIDTH 16%"/42.0 CM X HEIGHT 141/2"/36.9 CM X DEPTH 4%"/11.7 cm
;Cover'Mater'W and Color :Gray Metal
9ffEBEL -ELTRON 17 West St., W. Hatfield, MA 01088 1 i00.582.8423I 413.247.3380 1 fax 413.247.3369 1 info@stiebei-eltron-usa.com I www.stiebei-eltron-usa.com
O
I
0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0
Flow Rate GPM
Temperature Rise vs. Flow Rate at 240 V
90
80
70
60
50
a 40
E
30
20
10
0
90
80
70
60
LL 50
n 40
E
30
20
10
Tempra° 36
Tempra° 29
Tempra° 24
Tempra® 20
Tempra° 36
Tempra° 29
Tempra® 24
Tempra° 20
0
0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0
Flow Rate GPM
STIEBEL ELTROF117 West St., W. Hatfield, MA 010881800.582.8423 1413.247.33801 fax 413.247.3369 1 info@stiebel-eltron-usa.com I www.stiebei-eltron-usa.com
r-
Certified to ANSI/UL Std. 499
Conforms to CAN/CSA E335-1 & E335-2-35
i
i
> Tempra® tankless electric water heaters are suitable for whole house or multiple point -of -use applications.
*CU;A
Tested and certified
by WQA against NSF/
ANSI 372 for lead free
compliance.
> Tempra® tankless electric
water heaters are suitable
for booster applications,
accepting a maximum
incoming water temperature
of 131°F/55°C.
The tankless electric water heater shall be equipped with several copper sheathed heating elements housed in copper cylinders. The
number of heating elements shall be three in the case of the 12 M unit, four in the case of the 14.4 M and 19.2 M units, six in the
case of the 24 M and 28.8 M units and nine in the case of the 36 M unit. Each copper cylinder that houses heating elements shall
be equipped with a dedicated single pole bimetal type high limit that is attached to the top dome of the cylinder. These safety high
limit switches shall have a manual reset that interrupts power at 185°F. The heating elements shall be controlled by a number of triacs
(power transistors) that are soldered into the circuit board and cooled by the incoming cold water. The unit shall be equipped with a
flow sensor with a miniaturized turbine that feeds the water flow rate information into the main circuit board. The output temperature
shall be adjustable between 86°F and 140°F via a knob that is positioned on the front cover. The water connections shall be designed
for 3W NPT flex hose connectors. The housing shall be made of a powder coat painted steel and the front cover shall be hinged on the
left side of the housing. Tempra® Plus models shall be equipped with Advanced Flow Control -to automatically adjust the flow of water
to ensure a constant output temperature, even if demand exceeds capacity. The unit shall conform to ANSI ANSIML Std. 499 and be
certified to CAN/CSA E335-1 & E335-2-35.
STIEBEL ELTRON 17 West St., W. Hatfield, MA 01088 1800.582.84231413.247.3380 1 fax 413.247.3369 1 info@stiebel-eltron-usa.com I www.stiebei-eltron-usa.com