Loading...
HomeMy WebLinkAboutProject InformationLoad Shout Form Job: 1390 - wrightsoft® Date: 1214/2020 House By. Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone:772.800.8413 Email:Mdc lynrie@alrcaics.com For: ZeitzResidence,Air Conditioning Unlimited 8217 Maiden,cane Place, Port St. Lucie, FL 34952 Htg'., Gig innarawn Outside db (°F) 41 90 Method Blower door Inside db (°F) 70 75 Shielding / stories 3 (partial) / 1 Design TD (°F) 29 15 Pressure /AVF 50 Pa / 1247 cfm Daily range - L Inside humidity (%) 30 i 50 Moisture difference (grAb) 2 57 HEATING EQUIPMENT COOLING EQUIPMENT Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat 100 EFF 5.3 kW 18083 Btuh 27 °F 660 cfm 0.037 cfmBtuh 0.70 in H2O Make Goodman Mfg. Trade GOODMAN Cond GSX16S181A Coil ASPT25B14A AHRI ref 201786256 Efficiency Sensible cooling Latent cooling Total cooling Actual airflow Airflow factor Static pressure Load sensible heat ratio 13.0 EER,16 SEER 12600 Btuh 5400 Btuh 18000 Btuh 600 cfm 0.049 cfm/Btuh 0.70 in H2O 0.75 ROOM NAME Area W) j Htg load (Btuh) Clg load (Btuh) HtgAVF (cfm) CIgAVF (cfm) Bed 159 2610 1425 97 70 Bath 66 677 258 25 13 Master Bath 66 603 230 22 11 Master Bed 242 3183 1838 119 90 WIC 44 168 92 6 5 234 Kitchen Nook 234 3923 4776 146 Hall 79 0 0 0 0 Clst 9 0 0 0 0 Great Room j 431 4943 3607 184 177 a n I n n n Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrightsoft® 2020-Dec-07 16:21:37 Rlght Sute®Universal 2021 21.0.02 RSU29066 Page 1 ...ghtsoft HVAC18217 Maidencane Place PSL Prop.rLp Calc= MJ8 Front Door faces: N House 1336 16106 12225 600 600 Other equip loads 1143 607 Equip. @ 0.95 RSM 12241 Latent cooling 4182 —/1 AI CI -17)A a IrA)A Fnn nnn Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrightsoft® 2020-Dec-07 16:21:37 -- �� rt.tvu.em.. e.nw...r�•wm Right-Sute®Uruversa12021 21.0.02 RSU29066 Page 2 ...ghsoftHVAC18217MaidencanePlace PSLProp .rLp Calc=MJ8 FrordDoorfaces: N Building Alnal sis Job: 1390 - wrightsoft° g Date: 12/412020 House By. Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: %4ddlyrm@aircalcs.com Project• • For: Zeitz Residence, Air Conditioning Unlimited 8217 Maidencane Place, Port St. Lucie, FL 34952 Design Conditions Location: Indoor: Heating Cooling St Lucie Co Inti, FL, US Indoor temperature ('F) 70 75 Elevation: 26 ft Design TD ('F) 29 15 Latitude: 28'N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 2.4 56.9 Dry bulb (°F) 41 90 Infiltration: Dailyran%OF) - 15 (L ) Method Blower door Wet bulb (° ) - 77 Shielding / stories 3 (partial) / 1 Wind speed (mph) 15.0 7.5 Pressure /AVF 50 Pa / 1247 cfm Heating Component Btuh/ft2 Btuh % of load Walls 3.1 3316 19.2 Glazing 17.1 2031 11.8 Doors 3.7 i 74 0.4 Ceilings 1.6 2120 12.3 Floors 3.2 4302 24.9 Infiltration 2.0 2151 12.5 Ducts 2112 12.2 Piping 1 0 0 Humidification 1 0 0 Ventilation ;1143 6.6 Adjustments 0 Total 17249 1 100.0 Cooling Component Btuh/ft2 Btuli % of load Walls 1.9 2067 16.1 Glazing 26.1 3106 24.2 Doors 3.7 75 0.6 Ceilings 1.2 1633 12.7 Floors 0 0 0 Infiltration 0.6 640 5.0 Ducts 1413 11.0 Ventilation 607 4.7 Internal gains 3290 25.6 Blower 0 0 Adjustments 0 Total 128321 100.0 Latent Cooling Load =4182 Btuh Overall U-value = 0.226 Btuh/fF-'F n Data entries checked. Glazing �Ull iya Gains -Fld- 2020-Deo-0716:21:37 AL. Right-Sute@Universal 2021 21.0.02 RSU29066 Page 1 ...ghtsoitHVAQ8217 Maidencane Place PSL Prop.np Calc= MJ8 Front Door faces: N -�- wrightsoft® Component Constructions House Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: vicldlyve@aircalcs.com For: Location: St Lucie Co Intl, FL, US Elevation: 26 ft Latitude: 28ON Outdoor. Dry bulb (°F) Daily range (7) Wet bulb (T) Wind speed (mph) Zeitz Residence, Air Conditioning Unlimited 8217 Maidencane Place, Port St. Lucie, FL 34952 Indoor: Indoor temperature (7) Design TD (T) Relative humidity (%) Heating Cooling Moisture difference (grAb) 41 90 Infiltration: - 15 (L ) Method - 77 Shielding / stories 15.0 7.5 Pressure /AVF Construction descriptions j Walls Blk Wall, Stucco Ext, R-4.1 Ext Bd in[, 8" Thk, 1/2" Gyp Bd Int Fnsh Partitions Frm Wall, 1/2" Gyp Bd Ext, R-11 Cav Ins, 1/2" Gyp Bd It Fnsh, 2N4", 16" OC Stud Or Area U value ft' BtuhW--°F ne 328 0.109 se 95 0.109 sw 313 0.109 nw 197 0.109 all 933 0.109 Windows Impact, Clear Lowe: Impact, Clear Lowe; NFRC ratedl(SHGC=0'.24); ne 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green sw grass (0.23); 1 ft overhang (5.2 ft window ht, 1 ft sep.); 6.8 ft head ht nw Impact, Clear Lowe: Impact, Clear Lowe; NFRC rated (SHGC=0.24); all se foreground = green grass (0.23); 6 ft overhang (6.7 ft Wndow ht, 1 ft sep.); 6.8 ft head ht Impact, Clear Lowe: Impact, Clear Lowe; NFRC ratedl(SHGC=0.24); nw 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (3.17 ft window ht, 1 ft sep.); 6.8 ft head ht Impact, Clear Lowe: Impact, Clear Lowe; NFRC rated, (SHGC=0.21); nw foreground = green grass (0.23); 1 ft overhang (6.7 ft window ht, 1 ft sep.); 6.8 ft head ht Job: 1390 Date: 12/4/2020 By. Chris Bateman Heating Cooling 70 75 29 15 30 50 2.4 56.9 Blower door 3 (partial) / 1 50 Pa / 1247 crm Insul R Htg HTM Loss Clg HTM Gain ftV F/Btuh Btuht t' Btuh BtuhV Btuh 5.1 3.15 1035 2.02 662 5.1 3.15 298 2.02 190 5.1 3.15 986 2.02 630 5.1 3.15 622 2.02 398 5.1 3.15 2940 2.02 1881 128 0.101 11.0 2.94 376, 1.46 187 16 0.580 0 16.8 262 22.6 353 31 0.580 0 16.8 525 21.8 681 16 0.580 0 16.8 262 22.6 353 62 0.580 0 16.8 1050 22.2 1387 13 0.490 0 14.2 190 14.6 195 10 0.580 0 16.8 160 22.6 215 34 0.650 0 18.8 631 26.4 884 Doors Fbrgls Door se 20 0.127 7.0 3.69 74 3.73 75 Ceilings Attic, Shngl Roof, R-20 Roof Deck Ins, 1/2" Gyp Bd Int Fnsh 1336 0.405 21.0 1.59 2120 1.22 1633 Floors On Grade Depth, Tile Flr Fnsh 150 0.989 0 28.7 4302 0 0 2020-Deo-0716:21:38 WrightsOftg RightStite®Universal 2021 21.0.02 RSU29066 Page 1 ACCA► ...ghtsoft HVAC18217 Maidenrane Place PSL Prop.rp Calc= MJS Front Dcorfaces: N wrightsoft- 2020-Dec-0716:21:38 �� �NITet•/BUWhelbNmyCempay Right-Sdte@ UHvers42021 21.0.02 RSU29066 Page 2 ACM ...ghtsoftHVAC18217 Maidencane Place PSL Prop.rip Cal.= MA Front Doorfaces: N 390 Project Summary Job: 12/4 wri htsoft® Date: Chris Bat 9 House f By. Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: For: Notes: Zeitz RE 8217 M 3 Email:vicWlynne@aircalcs.com •OMI F11USTIff ence, Air Conditioning Unlimited :ncane Place, Port St. Lucie, FL 34952 Weather: St Lucie Cc Inti, FL, US Winter Design Conditi Inns Summer Design Conditions Outside db 41 OF OF Outside db 90 75 OF OF Inside db 70 Design TD 29 OF Inside db Design TD 15 -OF Daily range L Relative humidity 50 % Moisture difference 57 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 13994 Btuh Structure 10811 1413 Btuh Btuh Ducts 2112 Btuh Central vent (36 cfm). 1143 Btuh Ducts Central vent (36 cfm) 607 Btuh Outside air Humidification 0 Btuh Outside air Blower 0 Btuh Piping 0 Btuh Equipment load 17249 Btuh Use manufacturer's data n Rate/swingg multipplier Equipmentsensibleload 0.95 12241 Btuh Infiltration Method Blower door Latent Cooling Equipment Load Sizing Shielding / stories 3 (partial) / 1 S 1247 Structure 2062 Btuh Pressure /AVF 50 Pa cfm Ducts 734 Btuh Central vent (36 cfm) 1386 Btuh Heatingg Cooling Area (ftz) 1336 1336 Outside air Equipment latent load 4182 Btuh Volume (f?) 10688 10688 Air changes/hour 0.38 0.21 Equipment Total Load (Sen+Lat) 16424 Btuh Equiv AVF (cfm) 67 38 Req. total capacity at 0.70 SHR 1.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Goodman Mfg. Trade Trade GOODMAN Model Cond GSX16S181A AHRI ref Coil ASPT251314A AHRI ref 201786256 Efficiency 100 EFF Efficiency 13.0 EER,16 SEER Heating input 5.3 kW Heating output 18083 Btuh Sensible cooling Latentcooling 12600 5400 Btuh Btuh Temperature rise 27 OF Actual airflow 600 cfm Total cooling Actual airflow 18000 600 Btuh cfrn Airflowfactor .037 cfm/Btuh Airflowfactor 0.049 0.70 cfm/Btuh in H2O Static pressure 0.70 in H2O Static pressure Space thermostat Load sensible heat ratio 0.75 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. 41- wrightsoit- 2020-Deo-0716:21:38 At_•- - ...... -- , Right-SuteOUniversal 2021 21.0.02 RSU29066 Page 1 AC+L.P► ...ghtsoftHVAQ8217 Maidencane Place PSL Prop.np Calc= MA Front Door faces: N -I l- wrightsoft Right-J® Worksheet Job: 1390 House Date: 1214/2020 By. Chris Bateman Air Calcs, LLC 7550 Hidden HammockLR Vero Beach, FL32966 Phone:772.800.8413 Email: violdlynm@aircalcs.com 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area House 150.0 It 8.0 ft 1336.0 ft2 Bed 26.0 It 8.0 It heat1cool 1.0 x 159.3 It 159.3 112 Ty Construction number U-value (BtuW--°F) Or HTM (Btuhflt2) Area (ft2) or perimeter (ft) Load (Btuh) Area (f2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 V}/ I-G Blk Wall, Stuom Ext Impad,Clear Low-e Blk Wall, Stu000 Ext Impact, Clear Lowe Fbrgls Door Blk Wall, Stucoo Ext Impact, Clear Low-e BlVhk Wall, Stuoce Ext ImpacLClear Lowe Impact, Clear Lowe Impact, Clear Lowe Frm Wall, la' Gyp B Attic, Shngl Roof, R On Grade Depth, Tile 0.109 0.580 0.109 0.490 0.127 0.109 0.580 0.109 0.580 0.580 0.650 0.101 OA05 0.989 ne ne se se se sw sw nw nw nw nw 3.15 16.82 3.15 14.21 3.69 3.15 16.82 3.15 16.82 16.82 1 18.85 2.94 1.59 28.68 I 2.02 22.64 2.02 14.58 3.73 2.02 21.82 2.02 22.64 22.64 26.40 1.46 1.22 0.00 344 16 128 13 20 344 31 256 10 16 34 128 1336 1336 328 0 95 13 20 313 4 197 0 0 0 128 1336 150 1035 262 298 190 74 986 525. 622 160 262 631 376 2120 4302 662 353 190 195 75 630 681 398 215 353 884 187 1633 0 112 16 0 0 0 0 0 0 0 0 0 96 159 159 96 0 0 0 0 0 0 0 0 0 0 96 159 26 304 262 0 0 0 0 0 0 0 0 0 282 253 746 194 353 0 0 0 0 0 0 0 0 0 140 195 0 �DD V�! t-G ���jjj P C F 6 c) AED excursion 424 -16 Envelope loss/gain 11843 6881 1847 866 12 a) Infiltration b) Room ventilation 2151 0 640 0 225 0 67 0 13 Internal gains: Owipants@ 1 230 Appliancesnother 3 690 2600 0 0 250 Subtotal (lines 6 to 13) I 13994 10811 2071 1183 14 15 Less external load Less transfer Redistribution Subtotal Dud loads 15% 13% 0 0 0 13994 2112 0 0 0 10811 1413 15% 13% 0 0 196 2267 342 0 0 77 1260 165 Total room load Air required (cfm) 16106 1 600 12225 600 2610 97 1425 70 Calculations approved bVACCAto meet all requirements of Manual J 8th Ed. wr7gF�tsoft 2020-Dec-0716:21:38 Right-Sate®Universal 2021 21.0.02 RSU29066 Page 1 ghtsoftHVAC18217 Maidencane Place PSL Prop.np Calc= MJ8 FrontDoorfaces: N + wrightsoft, Right-J® Worksheet House Air Caics, LLC 755n Hidden Hammock Ln. Vero Beach, FL32966 Phone: 772.800.84,13 Email: vicldlynre@aircalcs.com Job: 1390 Date: 12/412020 By. Chris Bateman 1 Room name Bath Master Bath 2 E)posed wall 6.0 It 8.0 ft heaticooi 6.0 It 8.0 ft heaU000l 3 4 Room height Room dimensions x 6.0 ft x 6.0 ft 5 Room area 211.0 66.0 ft 660 ft211.0 Ty Construction U-value Or HTM Area (ft2) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat I Cool 6 V}! Blk Wall, Stucco Fed 0.109 ne 3.15 2.02 48 48 151 97 48 48 0 151 0 97 0 Impacf Clear Lowe 0.580 ne 16.82 22.64 0 0 0 0 0 0 0 0 VL Blk Wall, Stucco F)d 0.109 se 3.15 2.02 0 0 0 0 0 0 0 0 I-G Impact, Clear Lowe 0.490 se 114.21 14.58 0 0 0 0 0 0 0 0 0 11 D Fbrgls Door 0.127 se 1 3.69 3.73 0 0 0 0 0 0 yJ Blk Wall, Stucco F)d 0.109 sw 1 3.15 2.02 0 0 0 0 0 0 0 0 0 0 0 T-G Impact, Clear Lowe 0.580 sw 16.82 21.82 0 0 0 0 0 0 0 0 W, Blk Wall, Stucco F)d 0.109 nw 1 3.15 2.02 0 0 0 0 0 �- G Impact, Clear Lowe 0.580 nw 16.82 22.64 0 0 0 0 0 0 0 0 0 ImpaMClear Lowe 0.580 nw '16.82 22.64 0 0 0 0 0 0 Impact Clear Lowe 0.650 nw 18.85 26.40 0 0 0 0 0 0 0 0 0 0 0 P C Frm Wall,1l2" Gyp B Attic, Shngi Roof, R 0.101 0.405 2.94 1.59 1.46 1.22 0 66 0 66 0 105 0 81 66 66 105 81 F On Grade Depth, Tile 0.989 - 28.68 I I I 0.00 66 6 172 0 66 6 172 0 6 c) AED exairsion -3 -3 Envelope losstgain 428 174 428 174 12 a) Infiltration 96 29 96 0 29 0 b) Room ventilation 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 0 Appliances/other 0 Subtotal (lines 6 to 13) 524 203 524 203 Less external load 0 0 0 0 0 0 Less transfer 0 64 0 25 0 0 Redistribution 588 228 524 203 14 15 Subtotal Ductloads 15% 13% 89 30 15% 13% 79 27 Total room load 677 258 603 22 230 11 Air required (dm) 25 131 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. i�.F- wrigF�tsoft 2020-Dec-0716:21:38 RightSute®Universal 202121.0.02RSU29066 Page ghtsoft HVAQ8217 Maidencane Place PSL Prop.rkp 'Cale = MJ8 Front Door toes: N - - wrightsofts Right-J® Worksheet Job: 1390 House Date: 12/412020 By. Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email:,AcWlyrre@aircalcs.com 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area Master Bed 31.0 It 8.0 ft heaV000l 1.0 x 242.0 It 242.0 ft' WIC 0 It 8.0 ft heaUmol 5.5 x 8.0 ft 44.0 ft' Ty Construction number U-value (Btuhllt= °F) Or HTM (BtLlw) Area (ft') or perimeter (ft) Load (Btuh) Area (ft') or perimeter (ft) Load (Btuh) Heat Cool Gross NIPIS Heat Cool Gross N/P/S Heat Cool 6 11 ViJ L--G Blk Wall, Stucco F)d Impad,Clear Low-e Blk Wall, Stucoo Ext Impact, Clear Lowe FbrglsDoor Blk Wall, Stucco Ext Impact, Clear Lowe Blk Wall, Stucco Ext mpact, Clear Lowe pact, mpact, ClearLow•e im Impad,Clear Lowe Frm Wall, 1C1" Gyp B Attic, Shngl Roof R On Grade Depth, Tile 0.109 0.580 0.109 0.490 0.127 0.109 0.580 0.109 0,580 0.580 0.650 0.101 0.405 0.989 ne ne se se se sw sw nw nw nw nw ' 3.15 16.82 3.15 14.21 3.69 3.15 16.82 3.15 16.82 16.82 18.85 2.94 1.59 28.68 I i 2.02 22.64 2.02 14.58 3.73 2.02 21.82 2.02 22.64 22.64 26.40 1.46 122 0.00 136 0 0 0 0 0 0 112 0 16 0 0 242 242 136 0 0 0 0 0 0 96 0 0 0 0 242 31 429 0 0 0 0 0 0 304 0 262 0 0 384 889 274 0 0 0 0 0 0 194 0 353 0 0 296 0 0 0 0 0 0 0 0 0 0 0 0 0 44 44 0 0 0 0 0 0 0 0 0 0 0 0 44 0 0 0 0 0 0 0 0 0 0 0 0 0 70 0 0 0 0 0 0 0 0 0 0 0 0 0 54 0 G D V�1 --G WW I- G P C F 6 c) AED excursion 1 109 1 Envelope loss/gain 2268 1227 70 53 12 a) Infiltration b) Room ventilation 1 498 0 148 0 0 0 0 0 13 Internal gains: Occupants @ 1 230 Appliancestother 0 0 1 250 0 0 0 Subtotal (lines 6 to 13) 2765 1625 70 53 14 15 Less external load Less transfer Redistribution Subtotal Dud loads 15% 13% 0 0 0 2765 417 0 0 0 1625 212 15% 13%1 0 0 76 146 22 0 0 29 82 11 Total room load Air required (dm) 3183 1191 1838 901 1 168 1 6 92 5 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -rk- wrigF�tsoTt� 2020-Deo-0716:21:38 ACA ^� "" ^`- ^ Right -Suite® Universal 2021 21.0.02 RSU29066 Page 3 ghtsoftHVACl8217MaidencanePlace PSLProp.np Calc=MJ8 Front Door faces: N * wrightsoft' Right-J® Worksheet House Air Calcs, LL'C 79;en Hielfien Hammock Ln. Vero Beach. FL32966 Phone: 772.800.8413 Eniail:%dcldlynre@aircaics.com Job: 1390 Date: 12/4/2020 By. Chris Bateman 1 Room name IGtchen Nook Hall 2 Exposed wall 31.0 ft 8.0 It heatl000l 6.5 ft 8.0 ft heaUcool . 3 4 Room height Room dimensions 18.0 x 13.0 ft 1.0 x 78.5 ft 5 Room area 234.0 ft' 78.5 ft' Ty Construction U-value Or HTM Area (M Load Area (ftl) (ft) Load (Btuh) number (Btuh/t? °F) (Btuhlft2) or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross NIPS Heat Cool 6\ fBlk Wall, Stucco Ext 0.109 ne 3.15 2.02 0 0 0 0 0 0 0 0 0 0 0 0 Impact Clear Lowe 0.580 ne 16.82 22.64 0 0 0 0 0 0 0 0 _ Blk Wall, Stucoo Ext 0.109 se 3.15 2.02 0 0 0 0 0 0 0 Impact, Clear Lowe OA90 se 1421 14.58 0 0 0 0 0 0 0 0 0 LL��pp 11 Fbrgis Door Blk Wall, Stucco Ext 0.127 0.109 se sw 3.69 3.15 3.73 2.02 0 104 0 88 0 279 0 178 20 20 63 40 V�1 I G Impact Clear Lowe 0.580 sw 16.82 21.82 16 2 262 340 0 0 0 0 0 0 0 V�/ I---G Blk Wall, Stuan Ext 0.109 nw 3.15 2.02 144 101 0 318 160 204 215 0 0 0 0 0 Impact, Clear Lowe 0.580 nw 16.82 22.64 10 0 0 0 0 Impact, Clear Lowe 0,580 nw 16.82 22.64 0 0 0 0 0 0 lI--�G Impact, Clear Lowe 0.650 nw 18.85 26AO 34 0 631 884 0 0 32 0 32 94 47 P C Frm Wall,10 Gyp B Attic, Shngl Roof, R 0.101 OA05 2.94 1.59 1.46 1.22 0 234 0 234 0 371 286 79 79 125 96 F On Grade Depth, Tile 6.989 28.68 i i I 0.00 234 31 889 0 79 7 186 0 6 c) AED excursion 308 1-3 Envelope loss/gain 2911 2416 ; 468 180 12 a) Infiltration 498 148 40 0 12 0 b) Room ventilation 0 0 13 Internal gains: Occupants@ 230 2 460 0 0 0 Appliances/other 12001 Subtotal (lines 6 to 13) 3408 4224 508 192 Less external load 0 0 0 0 0 0 Less transfer 0 0 0 0 -508 -192 Redistribution 3408 4224 0 0 14 15 Subtotal Ducloads 15% 13% 514 552 15% 13% 0 0 Total room load -7 3923 146 4776 234,0 0 0 0 A r required (dm) Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrigF�tsoTt� 2020-Deo-0716:21:38 P. Right -Suite@ Universal 2021 21.0.02 RSU29066 Page 4 ..ghtsoft HVAQ8217 Maidencane Place PSL Prop.rp �Calc= MJ8 Front Door faces: N -�- wrightsoft9 Right-J® Worksheet Job: 1390 House Date: 12/4/2020 By. Chris Bateman Air Calcs, LL'C 7550 Hidden Hammock Ln. Vero Beach, FL32966 Phone:772.800.8413 Email: vialynne@alrcalcs.com 1 Room name Cist Great Room 2 Exposed wall 2.5 ft 41.0 ft 8.0 ft heat/ocol 8.0 ft heaV000l 3 Room height 4 Room dimensions 2.5 x 3.5 ft 1.0 x 431.3 ft 5 Room area 8.8 ft 431.3 ft' Ty Conshvcion number U-value (Btuhlit=--OF) Or HTM (Btuh&2) Area (ftz) or perimeter (ft) Load Area (ft?) (Btuh) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 \tL- Blk Wall, Stucco Ext 0.109 ne 3.15 2.02 0 0 0 0 0 0 0 0 0 0 0 0 G Impact Clear Low-e 0.580 0.109 ne 1 16.82 1 3.15 22.64 2.02 0 20 0 20 0 63 0 40 108 75 235 150 Blk Wall, Stucco Ext se 0 0 0 0 13 13 190 195 Impact, Clear Lower OA90 se 14.21 14.58 0 0 0 20 20 74 75 11 DD Fbrgls Door 0.127 se 3.69 3.73 0 0 0 0 0 220 204 644 412 yJ Elk Wall, Stucco Ext 0.109 sw 3.15 2.02 0 0 0 16 2 262 340 I - G Impact Clear Low-e 0.580 sw 16.82 21.82 0 0 0 0 0 0 VVV���111 Elk Wall, Stucco E)d 0.109 nw 3.15 2.02 0 0 0 0 0 0 Impact Clear Lomi-e 0.580 nw 16.82 22.64 0 0 0 0 0 0 0 0 ImpacttClear Low-e 0.580 nw 16.82 22.64 0 0 0 0 0 0 Impact, Clear Lowe 0.650 nw 18.85 26.40 0 0 0 0 0 0 0 0 0 0 0 P Frm Wall, 1 /2" Gyp B 0.101 2.94 1 A6 0 9 0 9 0 14 0 11 431 431 684 527 C Attiq Shngl Roof, R 0.405 1.59 1.22 3 72 0 431 41 1176 0 F On Grade Depth, Tile 0.989 28.68 0.00 9 6 c) AED excursion -11 1 33 Envelope loss/gain 149 50 3266 1733 12 a) Infiltration 40 12 658 0 196 0 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 900 Applianoestother 0 Subtotal (lines 6 to 13) 189 62 3924 3059 Less edernalload 0 0 0 0 0 0 Less transfer 0 -189 0 -62 371 131 Redistribution 0 0 4295 3190 14 Subtotal 15% 13% 0 0 15% 13% 648 417 15 Dudloads Total room load 0 01 0 0 4943 1 184 3607 177 Air required (dm) Calculations approved bVACCAto meet all requirements of Manual J 8th Ed. -*- wrigtitsoft" 2020-Deo-0716:21:38 Aft , , RigMSute®Uruversal 2021 21.0.02 RSU29066 Page 5 ghtsoft HVAC18217 Maidencane Place PSL Prop.rp Calc = MJ8 Frort Door faces: N + wrightsoft Right-J® Worksheet House Air Caics, LLC 76Rn ui,ir1=n I--nrk I n VPrn APnrh. FL32966 Phone: 772.800.8413 Email: vicldlWne@aircalcs.com Job: 1390 Date: 12/4/2020 By. Chris Bateman 1 Room name CISI2 2 Exposed wall 0 ft 8.0 It heaUcool 3 Room height 2.5 x 2.5 ft 4 Room dimensions 6.3 ft2 5 Room area Ty Construction number U-value (13tuh/ft2--°F) Or HTM Area (ft2) Load Area (BtuhiW) or perimeter (ft) (Btuh) or perimeter Load Heat Cool Gross N!P/S Heat Cool Gross NIPS Heat Cool 6 yJ Blk Wall, Stucco Ext 0.109 ne 3.15 2.02 0 0 0 0 0 0 —G Impact, ClearLowLe 0.580 ne 16.82 22.64 0 0 0 V Blk Wall, Stucco Ext 0.109 se 3.15 2.02 0 0 0 I _G Impact, Clear Low-e 0.490 se 14.21 14.58 0 0 0 0 0 11 L—D Fbrgls Door 0.127 se 3.69 3.73 0 0 0 U�/ Blk Wall, Stucco Ext 0.109 sw 3.15 2.02 0 0 0 0 0 0 �—G Impact, Clear Lowe 0.580 sw 16.82 21.82 0 0 0 0 Blk Wall, Stucco Ext 0.109 nw 3.15 2.02 0 0 Impact, Clear Lowe 0.580 nw 16.82 22.64 0 0 0 0 0 Impact, Clear Lowe 0.580 nw 16.82 22.64 0 0 0 Impact, Clear Lowe 0.650 nw 18.85 26AO 0 0 0 0 0 0 P C Frm Wall, ll2" Gyp B Attiq Shngl Roof, R 0.101 0.405 - 2.94 1.59 1.46 0 122 6 0 6 10 8 F On Grade Depth, Tile 0.989 - 28.68 0.00 6 0 0 0 6 c) AED exarsion 0 Envelope losstgain 10 8 12 a) Infiltration 0 0 0 0 b) Roomventilation 13 Internal gains: Occupants @ 230 0 0 Appliancestother 0 Subtotal (lines 6 to 13) 10 8 Less external load 0 0 0 Less transfer 0 -10 -8 Redistribution 0 0 14 Subtotal 15 Ductloads 15% 13% 0 0 Total room load 0 0 0 0 Air required (cfm) Calculations approved byACCAto meet all requirements of Manual J 8th Ed. 2020-Deo-07 16:e 6 -TT- ^�^•••' ••••'^-^ Right-Sute®Universal 2021 21.0.02 RSU29066 Page 6 ...ghlsoft HVAC18217 Maidencane Place PSL Prop.rLp ,Calc= MJ8 Front Door faces: N Duct System Summary Job- 1390 uc �- wrightsoft® y ry Date: 1214i2020 House By. Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800. I.413 Email: vlcldlyye@aircaics.com For. Zeitz Residence, Air Conditioning Unlimited 8217 Maidencane Place, Port St. Lucie, FL 34952 Heating External static pressure 0.70 in H2O Pressure losses 0 in H2O Available static pressure 0.70 in H2O Supply / return available pressure i 0.452 / 0.248 in H2O Lowestfriction rate 0.261 in/100ft Actual airflow 600 cfm Total effective length (TEL) 268 ft Cooling 0.70 in H2O 0 in H2O 0.70 in H2O 0.452 / 0.248 in H2O 0.261 in/100ft 600 cfm Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (in) H x W (in) Duct Mat Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Bath h 677 30 15 0.280 4.0 Ox 0 MFx 36.4 125.0 st2 Bed h 2610 117 84 0.261 6.0 OXO VIFx 43.0 130.0 st2 GreatRoom h 2471 110 106 0.267 6.0 Ox 0 MFx 44.7 125.0 st3 GreatRoom-A h 2471 110 106 0.360 6.0 Ox0 MFx 25.5 100.0 SO Kitchen Nook C 2388 88 141 0.264 7.0 Ox0 MFx 46.0 125.0 st3 Kitchen Nook -A c 2388 88 141 0.271 7.0 Ox 0 VIFx 41.9 125.0 st3 Master Bath h 603 27 14 0.278 4.0 Ox 0 MFx 37.4 125.0 st2 Master Bed -A h 3183 142 108 0.263 7.0 Ox 0 MFx 46.8 125.0 st3 wic h 168 7 5 0.277 4.0 Ox 0 VIFx 38.0 125.0 st2 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (Cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st2 PeakAVF 181 118 0.261 679 7.0 .0 x 0 VinIFIX st1 st3 PeakAVF 428 496 0.263 631 12.0 0 x 0 VinIFIX st1 st1 PeakAVF 720 I720 0.261 674 14.0 0 x 0 VinIFIX - wrightsoft°° �� nNrt�aio«m�ww�eru��w�r Right-Sute®Uruver�1202121.0.02RSU29066 ...ghsoftHVAC18217MaidencanePlacePSLProp.nQ Calc=MJ8 FrontDoorfaces: N 2020-Dec-0716:21:38 Page 1 Grille Htg Clg l EL Design Ueloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (Cfm) (ft) FR (fpm) (in) (in) Opening (in) Mat Trunk rb1 Ox 0 117 84 79.1 0.313 334 &0 0x 0 VIFx rt1 rb5 Ox 0 150 114 94.8 0.261 339 9.0 0x 0 VIFx rt1 rb4 Ox 0 454 522 57.7 0.429 489 14.0 Ox 0 VIFx rt1 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfrn) (cfm) FIR (fpm) (in) (in) Material Trunk rt1 PeakAVF 720 ;720 0.261 516 16.0 0 x 0 VnIFIX Boldldalic values have been manualy overridden 2020-Deo-0716:21:38 aWra9~ � � Right-Sute®Universal202121.0.02RSU29066 Paget ...ghlsoft HVAC18217 Maidencane Place PSL Prop.np Calc= MJ8 Front Doorfaces: N Manual S Corn liance Report Job: 1390 -�d- wrightsoft® p p Date: 121412020 House By. Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone:772.800.8,413 Email: vicldlyrm@aircalcs.com Project• • For: Zeitz Residence, Air Conditioning Unlimited 8217 Maidencane Place, Port St. Lucie, FL 34952 Cooling Equipment Design Conditions Outdoor design DB: 90.4°F Sensible gain: 12832 Btuh Entering coil DB: 76.07 Outdoor design WB: 77.4°F Latent gain: 4182 Btuh Entering coil WB: 63.8°F Indoor design DB: 75.0°F Total gain: 17014 Btuh Indoor RH: 50% Estimated airflow: 600 cfm Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: SplitAC Manufacturer: Goodman Mfg. Model: GSX16S181A+ASPT25B14A Actual airflow: 600 cfm Sensible capacity: 13190 Btuh 1'03% of load Latent capacity: 4521 Btuh 108% of load Total capacity: 17711 Btuh 1'04% of load SHR: 74% Heating Equipment Design Conditions Outdoor design DB: 41.0°F Heat loss: 17249 Btuh Entering coil DB: 68.1°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Elec strip Manufacturer. Model: Actual airflow: 600 cfm Output capacity: 5.3 kW 1:05%of load Temp. rise: 50 OF Meets all requirements ofACCA Manual S. 2020-Deo-0716:21:38 �-!'� wrightsoft® , .t•,� mh ,�M1..„ �mv.� Right-Stite@ LINversal 2021 21.0.02 RSU29066 Page 1 ...ghtsoftHVAQ8217 Maldencane Place PSL Prop.rLp Calc= MA Front Door faces: N Job #: 1390 Performed by Chris Bateman for: Zeitz Residence 8217 Maidencane Place Port St. Lucie, FL 34952 Level 1 Air Calcs, LLC 7550 Hidden Hammock Ln Vero Beach, FL 32966 Phone: 772.800.8413 vickilynne@airca[cs.com Scale: 1 : 132 Page 1 RightSuite® Universal 2021 21.0.02 RSU29066 2020-Dec-0716:21:52 17 Maidencane Place PSL Prop.rup Job M 1390 Performed by Chris Bateman for: Zeitz Residence 8217 Maidencane Place PortSt Lucie, FL 34952 Level 1 Air Calcs, LLC 7550 Hidden Hammock Ln Vero Beach, FL 32966 Phone: 772.800.8413 vickilynne@aircalcs.com Scale: 1 : 94 Page 1 RightSuite® Universal 2021 21.0.02 RSU29066 2020-Dec-0716:19:05 17 Maidencane Place PSL Prop.rup