HomeMy WebLinkAboutAPPROVED, Merged Current - Extreme-Cover Sheets FL20378.2 Standing Seam2/13/2018 Florida Building Code Online
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqua%2flMZ8n5CNV4ZYkew5Zoa%2fE%2fovztqlbhDVU2dJO4TAA%3d%3d 1/4
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search
Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #FL20378-R1
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer Extreme Metal Fabricators, LLC
Address/Phone/Email 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 flvalidation@yahoo.com
Authorized Signature Richard McKuhen flvalidation@yahoo.com
Technical Representative Richard McKuhen
Address/Phone/Email 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 richard@emfab.net
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the
Evaluation Report
LOCKE BOWDEN
Florida License PE-49704
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By Zachary R. Priest, P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence FL20378_R1_COI_FL 20378.1 NAILSTRIP 1.0_.032 ALUM_sss.pdf
Referenced Standard and Year (of Standard)Standard Year
TAS 125 2003
UL 1897 2012
UL 580 2006
Equivalence of Product Standards Certified By
Sections from the Code
2/13/2018 Florida Building Code Online
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqua%2flMZ8n5CNV4ZYkew5Zoa%2fE%2fovztqlbhDVU2dJO4TAA%3d%3d 2/4
Product Approval Method Method 1 Option D
Date Submitted 08/18/2017
Date Validated 12/18/2017
Date Pending FBC Approval 10/17/2017
Date Approved 12/19/2017
Summary of Products
FL #Model, Number or Name Description
20378.1 01 - "1" Nailstrip"0.032” Aluminum Standing Seam roof panel, 12” wide,
mechanically attached to 15/32" plywood or Wood Deck with
fasteners.
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-Table A Other: Refer to evaluation report for Limitations and
Conditions of Use. Refer to manufacturer’s installation
instructions.
Installation Instructions FL20378_R1_II_FL 20378.1 NAILSTRIP 1.0_.032
ALUM_sss.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL20378_R1_AE_FL 20378.1 NAILSTRIP 1.0_.032
ALUM_sss.pdf Created by Independent Third Party: Yes
20378.2 02 - "1" Nailstrip"26-gauge Steel Standing Seam roof panel, 16” wide,
mechanically attached to 15/32" plywood or Wood Deck with
fasteners and adhesive.
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-Table A Other: Refer to evaluation report for Limitations and
Conditions of Use. Refer to manufacturer’s installation
instructions.
Installation Instructions FL20378_R1_II_FL 20378.2 Extreme Metal Fabricators_ 26GA
NAIL STRIP 1.0.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL20378_R1_AE_FL 20378.2 Extreme Metal Fabricators_
26GA NAIL STRIP 1.0.pdf Created by Independent Third Party: Yes
20378.3 03 - "1.75 Snap Lock"0.032” Aluminum Standing Seam roof panel, 18” wide,
mechanically attached to 15/32" plywood or Wood Deck with
panel clips and fasteners.
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-Table A Other: Refer to evaluation report for Limitations and
Conditions of Use. Refer to manufacturer’s installation
instructions.
Installation Instructions FL20378_R1_II_FL 20378.3 SNAP LOCK ALUM 1.75-ssr.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL20378_R1_AE_FL 20378.3 SNAP LOCK ALUM 1.75-ssr.pdf Created by Independent Third Party: Yes
20378.4 04 - "1.75" Snap Lock"24-gauge Steel Standing Seam roof panel, 18” wide,
mechanically attached to 15/32" plywood or Wood Deck with
panel clips and fasteners.
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-Table A Other: Refer to evaluation report for Limitations and
Conditions of Use. Refer to manufacturer’s installation
instructions.
Installation Instructions FL20378_R1_II_FL 20378.4_1.75 SNAP LOCK 24GA-ssr.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL20378_R1_AE_FL 20378.4_1.75 SNAP LOCK 24GA-ssr.pdf Created by Independent Third Party: Yes
20378.5 05 - "Rib Panel"29-gauge Steel exposed fastener roof panel, 36” wide,
mechanically attached to 15/32" plywood or Wood Deck with
fasteners.
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-Table A Other: Refer to evaluation report for Limitations and
Conditions of Use. Refer to manufacturer’s installation
instructions.
Installation Instructions FL20378_R1_II_FL 20378.5 RIB 29GA_ssr.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL20378_R1_AE_FL 20378.5 RIB 29GA_ssr.pdf Created by Independent Third Party: Yes
2/13/2018 Florida Building Code Online
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqua%2flMZ8n5CNV4ZYkew5Zoa%2fE%2fovztqlbhDVU2dJO4TAA%3d%3d 3/4
20378.6 06 - "5V Crimp"26-gauge Steel exposed fastener roof panel, 24” wide,
mechanically attached to 15/32" Plywood or Wood Deck
w/fasteners.
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-Table A Other: Refer to evaluation report for Method 1 and Method 2
fastening. Limitations and Conditions of Use. Refer to
manufacturer’s installation instructions.
Installation Instructions FL20378_R1_II_FL 20378.6_5V Crimp_sss.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL20378_R1_AE_FL 20378.6_5V Crimp_sss.pdf Created by Independent Third Party: Yes
20378.7 07 - "1.5 Standing Seam"24-gauge Steel Standing Seam roof panel, 16” wide,
mechanically attached to 15/32" plywood or Wood Deck with
panel clips, fasteners and adhesive
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-Table A Other: Refer to evaluation report for Limitations and
Conditions of Use. Refer to manufacturer’s installation
instructions.
Installation Instructions FL20378_R1_II_FL 20378.7 JM STANDING SEAM_ssr.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL20378_R1_AE_FL 20378.7 JM STANDING SEAM_ssr.pdf Created by Independent Third Party: Yes
20378.8 08 - "Nordman Tile"24-gauge Steel metal roof tile panel mechanically attached to
15/32" plywood or Wood Deck with fasteners
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-Table A Other: Refer to evaluation report for Limitations and
Conditions of Use. Refer to manufacturer’s installation
instructions.
Installation Instructions FL20378_R1_II_FL 20378.8_NORDMAN TILE 24GA_ssr.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL20378_R1_AE_FL 20378.8_NORDMAN TILE 24GA_ssr.pdf Created by Independent Third Party: Yes
20378.9 09 - "Nordman Tile"24-gauge Steel metal roof tile panel mechanically attached to
Steel Deck with fasteners
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-Table A Other: Refer to evaluation report for Limitations and
Conditions of Use. Refer to manufacturer’s installation
instructions.
Installation Instructions FL20378_R1_II_FL 20378.9 Nordman Tile Details-ssr.pdf Verified By: James L. Buckner, P.E. @ CBUCK Engineering P.E.
#31242 Created by Independent Third Party: Yes Evaluation Reports FL20378_R1_AE_FL 20378.9 Nordman Tile Details-ssr.pdf Created by Independent Third Party: Yes
20378.10 10 - "Nordman Tile"0.032" Aluminum metal roof tile panel mechanically attached
to 15/32" plywood or Wood Deck with fasteners.
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-Table A Other: Refer to evaluation report for Limitations and
Conditions of Use. Refer to manufacturer’s installation
instructions.
Installation Instructions FL20378_R1_II_FL 20378.10 NORD TILT .032 ALUM-ssr.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL20378_R1_AE_FL 20378.10 NORD TILT .032 ALUM-ssr.pdf Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S.,
please click here .
Product Approval Accepts:
Product Report Manufacturer: Extreme Metal Fabricators, LLC.
2160 SW Poma Drive
Palm City, FL 34990
772 872-8034
Compliant with Florida Building Code 2017 (6th ed.)
Compliant with Florida Product Approval Rule # 61G20-3
Compliant: Keystone Certifications
Product: 1" Nailstrip 26GA Steel Standing Seam Roof Panel FBC Sec. 1507.4.2
Yield strength: 40ksi: Attached to Wood Deck with screws.
16" Coverage
Corrosion Resistant Compliant: FBC Sec. 1507.4.3
Fastener for Method 1 Attachment # 10 x 1" Pancake Head wood screw to penetrate
3/16" thru 15/32" min. plywood deck
Seam Adhesive: Bostik Chem Chalk 915, one component, polyurethane adhesive
along male flange the full length of panel.
Underlayment: To be compliant with FBC Sec. 1507
Slope: Shall be in compliance with FBC Sec. 1507. 1.1
Install Details: Table A Allowable Loads METHOD 1 main field METHOD 2 perimeter
DESIGN PRESSURE* -69.25 PSF -121.75 PSF
FASTENER SPACING-ALONG ROWS 6" o.c.6" o.c.
FASTENER SIZE: #10 #10
ADHEISIVE: NOT REQUIRED 3/8" BEAD (refer to
install details)
Certificate of Independence:
Locke Bowden, P.E. does not have, not will acquire a financial interest h�\ilf\t'!o\tifitlny,manufacturing or distributing products
under this evaluation. , '·'� Q. BOW, i 11•',, ,, ,l ,.,. " • • t " . . l, �.Locke Bowden, P.E. is not owned, operated, or controlled by any ��an�i''ta.'l!!�c."tw er, �distributing products under this '� ' ... - � report. ��'-' � _-· �� 7�:A ·.,��!: ,. v, 'J 9r7>/, •. �pV�
� • "),( • p' � -l· " • .. -, �-•. ..-·· Or .t:;; 7;7 ,:,--O o ';J1 1 C:. 9�-"': r ')':> • 0 •c� • a,;., 0, • ,, FLO .\ , � cu :�,-,.,,. 'J'� ..• :, , .... <� -� ..;-· 11, � ') ..i ION P.. \.. �,-:,..,
f(:1::1!: \,\\\\
Reference Data: HURRICANE TEST LABORATORY, L.L.C. #TST ID: 1527
Report #:0223-0313-02 TAS125-03(UL 580-06/UL 1897-041)
Report#: 0223-1015-06 TAS125-03(UL 580-06/UL 1897-041)
EQUIVALENCY: UL 1897-04 IS EQUIVALENT TO UL 1897-12 TEST STANDARD * DESIGN PRESSURE MARGIN OF SAFETY 2:1
FL 20378.2 1.0 Nail Strip (26GA Steel), 16" Wide Roof Panel - Details
Limitations:
1.Underlayment to be compliance with current Florida Building Code (FBC)2017 6th ed..
2.Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer’s installation reference.
3.Products are compliant for State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D
4.Engineering analysis for “project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
5.Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6.Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural
Loading.
7.This report does not imply warranty, installation, recommended product use outside of this report.