IM5V Panel REVIEWED �
CODE COMPLIANCE
f r 26ga (min) 24" wide 5V pand-ppL1
Florida Product Approval Number 3l ZZ(
Compliance statement:)' This.product as described has demonstrated compliance with
Florida--Building Code 2020, Section 1504.3.2, as required by Rule
61 G20-3, method 1 D
Manufacturer: Integrity Metals, LLC 12640 Piper Dr, Ste. B, Vero Beach, FL
32960 i 772-584-2654 1 www.intregritymetaisfl`com
Product: IM5V is an exposed'fastener 5V style panel with a 24" coverage,
and nominal rib height of 7/16."
Material: This product is manufactured from 26ga:(Min)steel with corrosion
resistance per FBC 1507.4.3:.
Fastener:-, #10 x 1-1/2"fastener with sealing washer, compliant:with FBC
1506.6. Larger diameter and longer-length fasteners are
acceptable. Stainless steel fasteners.may be used.
Substrate/Deck: Minimum 15/32"thick plywood:
Underlayment: Comply with F13C:1507A 1 where-applicable.
Slope: Comply with-FBC 1507 4 2 whereapplicable.
Tech nical'Documentation: This product-has beentested to the UL 580-06%and UL 1897-04
(revised 2008)standard by Intertek Testing (TST-1527), report
17226 03=450-44 R0. This test.report is owned by Quality Metal
Roof Fabricators, who has given written authorization for•Integrity.
Metals to use.this report.
Max.Allowable Loads - = Method A: 116psf I Install fasteners in 12-12" pattern (one fastener•
per rib), at 12" o.c. max.
Installation Requirements: Factor of.Safety of 2.0 applied to calculate...allowable loads.
Evaluated By_: i DaVUEn9 'PE
Timberlake Cove,;LLC
33244 Uriv. Ave#206=Gainesville FL 32607-
PE Lic. No: 81377
CA Lic. No: 33344
icEry'
�� www.timberiakecove.com
t No.813
ATE OF
��51 '•.�ORIOP,.•'• � �
ONALL NG\``•
www.integrityMetalsFI.com Page 1
INTEGRITY 2604 Piper St Ste B
METALS Vero Beach FL 32609
METAL ROOFING MADE HERE (772) 584-2654
Panel Accessories: The manufacturer does not require the use of closures,
sealants, butyl, or other similar accessories between bottom
edge of panel and drip edge, or in other locations. The use
of closures and sealants may be advisable in some cases,
however that decision is the discretion of the project owner
and the installer.
Certification,of Indep endence David Eng, PE and Timberlake Cove, LLC do not have, nor_
will acquire a financial interest in any company
manufacturing or distributing products under this evaluation.
The same entities do not have, nor will acquire, a financial.
interest in any other entity involved in the approval process
of the_product.
Exclusions & Limitations: Design of deck.and roof structure (to include attachment of
plywood or wood plank) shall be completed by others. Fire`
classification and shear diaphragm design are outside the
scope of this evaluation.
This report is limited-to compliance with structural wind load`
3 „ requirements of FBC 1504.3.2, as required by Rule 61G20-
3. Neither Timberlake Cove nor the.manufacturer shall be
responsible-for any conclusions, interpretations, or designs
`made by others based on this evaluationreport. This report
is.limited solely.to.documenting compliance with Rule
61.G20-3, and:makes no express or implied warranty
regarding performance of this product.
Design Process: The load ta6les,in this report provides one prescriptive
option for the fastening requirement for the applicable wind
loads for roofs within the parameters described. For roofs
outside of,the listed:parameters, design wind loads shall be ,
<�determined as required:by FBC 1609, ASCE 7, or,other .
design code in force, using allowable stress. These load
tables are,based on ASCE 7-16. Use of these tables
s
assumes that the structure is:
■ Enclosed and conforms to wind-borne debris provisions
and is a regular shaped building
■ Is,not subject to across-wind loading,,_vortex shedding, or
� _instability, nordoes it have-a site,Iocation`for wlirph
3 I T S 1 % i S'
channeling or buffeting warrant consideration
` En neerin` anal, sis ma begeom completed b other licensed
f g_ 9 Y. Y r p Y
engineers for project specific approval by local authorities
having jurisdiction.
FL29444.4 www.IntegrityMetaisFI.com Page 2
INTEGRITY 2604 Piper St Ste B
METALS Vero Beach FL 32609
METAL ROOFING MADE HERE (772) 584-2654
Design Load Tables:
rl
2 3
Select the appropriate load table that applies to the a
structure in question. 1 2
Determine the design wind speed for the project
location. - 2 3 —aP,2 3 TTUse the attachment method indicated for that windspeed`within each roof zone. 1 2
NOTE:ASCE 7-16 and FBC 2020 adopt a 7-zone a 3 2 3
concept. For the load tables below,the worst case {��a HIP ROOF GABLE ROOF I a�-
was taken for each zone and reported using the
standard zones 1-2-3:
.. LESS THAN EAST NOQ OF LEAST
EAIWENSI HORIZONTAL
DWENSION ER IS SMALLER.BUT NOT
Zone 1 includes zones 1 and 1' OR ASDANEAINEDB DESIGN
O OTMER ALDIMENSICODE OR?FT(0.96)
OR AS OETEWAINED BY DESIGN OR OTNERAPPLICABIEOODE.
Zone 2 includes zones 2e, 2r, and 2n ROOF ZONES FOR GENERIC BUILDING
Zone 3 includes zones 3e and 3r
Combining these zones creates a clear, simple scheme, at the expense of some design efficiency.
Contact the manufacturer for further information, or consult a licensed design professional.
FASTENER PATTERN AT 12" O.C. Method A: Install fasteners in 9-
12=12" pattern (one fastener per '
,r 'r rib), at 12" o.c. max
NR: Consult a design
professional to assess the
#10 X 1-12"WOOD SCREW W1 proposed installation
SEALING WASHER
Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria:
Are located in Exposure B area Are located in B,C,or D exposure area
Have either a flat roof,or gable/hip roof with max slope of 451 'Have either a flat roof,or gable/hip roof with max slope of 45°
Have a mean roof height of 30 feet or less Have a mean roof height of 30 feet or less
FL29444A 26 a IM5V on 15/32" pl ood FL29444A 26 a IM5V on 15/32" I ood
Wind 120 130 140 150 160 170 180 190 200 Wind 120 130 140 150 160 170 180 190 200
Zone 1: A A A A A A A -A A Zone 1:: 'A A A A A A A
Zone 2: A A A A A A A A Zone 2:' A A A A
Zone 3: A A A A A A A Zone 3: A A A
Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria:
Are located in Exposure B area Are located in B,C,or D exposure area
Have either a flat roof less than 7°,hip roof with Have either a flat roof less than 7°,hip roof with
max slope of 45°,or gable roof with slope between 20°and 45, max slope of 450,or gable roof with slope between 20`and 45°
Have a mean roof height of 30 feet or less Have a mean roof height of 30 feet or less
FL29444A 26 a IM5V on 15/32" plywoodd FL29444A 26 a IM5V on 15/32" plyWood
Wind 120 130 140 150 160 170 180 190 200 Wind 120 130 140 150 160 170 180 190 200
Zone 1: A A A A' A A A A A Zone 1: A A A A A A A A
Zone 2: A A A A A A A A A Zone 2: A A A A A
Zone 3: A A A A A A A A Im Zone 3: A A A
FL29444.4 www.IntegrityMetaisFI.com Page 3
File ronv
REVIEEu FOP,
CODE COMPLIANCE NEMO I etc.
ST. L CIE COUNTY Certificate of Authorization#32455
` OG / 1�, / 353 Christian Street, Unit#13
3 Z ' Oxford,CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
REPORTEVALUATION
Soprema, Inc. Evaluation Report S18010.06.09-1119
1640 rue Haggerty FL2569-1121
Drummondville, QuebecJ2C 5P8 Canada Date of Issuance:06/15/2009
(819)478-2400 Revision 19: 12/16/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 7th Edition(2020)Florida Building Code sections noted herein.
DESCRIPTION: Soprema Roof-Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.1.1.
CONTINUED COMPLIANCE:This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance or production facility location(s)changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEW ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEW ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT:The Florida Product Approval Number (FL#) preceded by the words "NEMO I etc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer
or its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 9.
Prepared by:
A,�.a�
Robert J.M.Nieminen,P.E. The facsimile seal appearing was authorized by Robert
Florida Registration No.59166+Florida DCA ANE1983 �s i_"i+�;r` Nieminen,P.E.on 12/16/2020.This does not serve as
" an electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEW ETC,LLC does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
©2019 NEMO ETC,LLC
` r
(NNEMOJetc.
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Soprema Roof Underlayments,as produced by Soprema,have demonstrated compliance
with the following sections of the 7t'Edition(2020)Florida Building Code through testing in accordance with the
following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use
set forth herein.
2. STANDARDS:
Section Property Standard Year
1504.3.1 Wind resistance FM 4474 2011
1504.3.1 Wind resistance UL 1897 2015
1507.1.1,1507.2.4,1507.2.9.2 Material standard ASTM D1970 2015
/R905.1.1,R905.2.8.2
1507.3.3/R905.3.3 Material standard FRSA/TRI,Sixth Edition 2018
1507.11.2/R905.11.2 Material standard ASTM D6163 2015
TAS 110 Accelerated Weathering ASTM D4798 2011
3. REFERENCES:
Entity Examination Reference Date
ERD(TST6049) Wind Resistance 2778.07.05 07/15/2005
ERD(TST6049) ASTM D1970/TAS 110(QC) S31370.03.10-1-R1 04/07/2010
ERD(TST6049) FRSA/TRI 04-12(OH) S11150.05.09-R2 10/05/2010
ERD(TST6049) ASTM D1970(OH) S37210.11.11 11/09/2011
ERD(TST6049) ASTM D1970(MS) 537210.12.11 12/01/2011
ERD(TST6049) ASTM D1970(MS) 540540.02.13-1 02/19/2013
ERD(TST6049) FRSA/TRI 04-12(MS) S43530.02.14-1-R1 02/21/2014
ERD(TST6049) ASTM D1970(BC) S44870.04.14-2 04/02/2014
ERD(TST6049) ASTM D1970(QC) S44870.04.14-3 04/02/2014
ERD(TST6049) ASTM D1970(OH) S44870.04.14-1 04/10/2014
ERD(TST6049) ASTM D1970(MS) S44870.04.14-4 04/10/2014
ERD(TST6049) ASTM D1970(OH) S40540.10.14 10/31/2014
ERD(TST6049) Tensile Adhesion/Long Term Aging SOPC-SC7645.02.15 02/13/2015
ERD(T5T6049) Accelerated Weathering SOPC-SC8520.04.14 04/27/2015
ERD(TST6049) Wind Resistance SOPC-SC14045.05.17-RI 06/07/2017
M-D(CER1592) HVHZ Compliance 18-0329.03 06/28/2018
ICC-ES(EVL2396) 2015 IBC Compliance ESR-1524 03/01/2017
NEMO(TST6049) ASTM D1970/TAS 110(QC) SOPC-SC8970.08.15-RI 04/25/2018
NEMO(TST6049) Wind Resistance 4-SOPC-18-003.08.18 08/27/2018
NEMO(TST6049) ASTM D4798/D1970(OH&MS) 4S-SOPC-18-002.05.19.A 05/31/2019
NEMO(TST6049) Tensile Adhesion/Long Term Aging 4p-DOW-I9-SSLAP-01.A.R2 02/10/2020
MEMO(TST6049) Peel adhesion(existing underlayments) 4j-SOPC-I9-SSUDL-04.A 03/12/2020
NEMO(TST6049) Peel adhesion(existing underlayments) 4j-SOPC-20-SSUDL-01 12/16/2020
PRI(TST5878) ASTM D1970(MS) SOP-064-02-01 12/03/2013
Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015
UL,LLC(QUA9625) Quality Control MLA File No.R16814 12/10/2015
UL,LLC(QUA9625) Quality Control MLA File No.R27605 05/08/2019
UL,LLC(QUA9625) Quality Control Service Confirmation 06/29/2020
UL,LLC(QUA9625) Quality Control Florida BCIS Current
NEMO ETC,LLC Evaluation Report S18010.06.09-1119
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-R21
Soprema Roof Underlayments Revision 19:12/15/2020
Page 2 of 9
NEMO etc.
4. PRODUCT DESCRIPTION:
Product Material Piant(s) Description
Standard
4.1 Lastobond TU HT ASTM D1970 and Gulfport,MS self-adhering,non-woven polyester fabric
FRSA/TRI 09-18 surfaced,SBS modified bitumen roof
underlayment
4.2 Tri-Built S/A HT TU ASTM D1970 and Gulfport,MS self-adhering,non-woven polyester fabric
Underlayment FRSA/TRI 09-18 surfaced,SBS modified bitumen roof
underlayment
4.3 Lastobond Shield ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS
modified bitumen roof underlayment available in
two widths;36 and 45 inch
4.4 RESISTO SA SMOOTH PLY ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS
40 modified bitumen roof underlayment
4.5 Lastobond Shield HT ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,high
temperature,SBS modified bitumen roof
underlayment
4.6 Lastobond Pro HT-N ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS
modified bitumen roof underlayment available in
two widths;36 and 45 inch
4.7 Lastobond Pro HT-S ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,high
temperature,SBS modified bitumen roof
underlayment
4.8 EnviroShield ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,high
temperature,SBS modified bitumen roof
underlayment
4.9 Lastobond 195 ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,sand-
Wadsworth,OH surfaced,SBS modified bitumen roof
underlayment
4.10 Lastobond Eaves ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,sand-
Protection Sheet Wadsworth,OH surfaced,SBS modified bitumen roof
underlayment
4.11 Lastobond Eco ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
4.12 Lastobond Smooth Seal ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film-
HT Wadsworth,OH surfaced,SBS modified bitumen roof
underlayment
4.13 Tri-Built Smooth HT S/A ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film-
Underlayment Wadsworth,OH surfaced,SBS modified bitumen roof
underlayment
4.14 PrimeSource Grip-Rite ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film-
Smooth Seal HT Wadsworth,OH surfaced,SBS modified bitumen roof
underlayment
4.15 RESISTO LB1236 ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
4.16 TRI-BUILT Sand-R SA ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
Shingle Underlayment Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
NEMO ETC,LLC Evaluation Report S18030.06.09-1119
Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION F1.2569-1121
Soprema Roof Underlayments Revision 19:12/15/2020
Page 3 of 9
L ,y
MEMO etc.
Product Material Plant(s) Description
Standard
4.17 PrimeSource Grip-Rite ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
Eave&Valley Protector Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
4.18 SRS TopShield ICE& ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
WATER DEFENDER Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
4.19 RESISTO LB1244 ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
4.20 Colphene FR GR ASTM D6163 Gulfport,MS self-adhering,fiberglass reinforced,granule-
Wadsworth,OH surfaced,SBS modified bitumen roof
underlayment
S. WITATIONS:
5.1 This is a building code evaluation. Neither NEIVIO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer
of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami-
Dade Counties).
5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for'requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.5 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
FBC Section: 1507.2 1507.3 1507.4&1507.5 1507.7 1507.8&2507.9
Clay and Concrete Tile Metal Slate or
Asphalt Wood Shakes or
Underlayment Mechanical Adhesive- Slate-Type
Shingles Attach Set Panels Shingles Shingles
Shingles
Lastobond TU HT,Tri-Built S/A HT TU Yes Yes
Underlayment Yes Yes See5.6.1 Yes Yes Yes Qoint strips,1507.1.1.3/
R905.1.1.3)
Lastobond Shield,Pro HT-N,RESISTO SA Yes
SMOOTH PLY40 Yes No No No No Yes Qoint strips,1507.1.1.3/
R905.1.1.3)
Yes
Lastobond Shield HT,Pro HT-S Yes No No Yes Yes Yes (joint strips,1507.1.1.3/
R905.1.1.3)
Yes
Enviro5hield Yes No No Yes Yes Yes aoint strips,1507.1.1.3/
R905.1.1.3)
Lastobond Eaves Protection Sheet, Yes
Lastobond195 Yes No No No No Yes aoint strips
,1507.1.1.3/
R905.1.1.3)
NEMO ETC,LLC Evaluation Report S18010.06.09-1119
Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-1121
Soprema Roof Underlayments Revision 19:12/15/2020
Page 4 of 9
ONEMOjetc.
TABLE 1: ROOF COVER OPTIONS
FBC Section: 1507.2 1507.3 1507.4&1507.5 1507.7 1507.8&1507.9
Clay and Concrete Tile Metal Slate or
Asphalt Slate-Type Wood Shakes or
Underlayment Shingles Mechanical Adhesive- panels Shingles Shingles
Attach Set Shingles
Lastobond ECO,RESISTO LB1236,TRI-
BUILT Sand-R SA Shingle Underlayment, Yes
Grip-Rite Eave&Valley Protector, Yes No No No No Yes (joint strips,1507.1.1.3/
TopShield ICE&WATER DEFENDER, R905.1.1.3)
RESISTO LB1244
Lastob oth Seal H Tri-Built Yes
mooth-HT derlaymen, p-Rite Yes No No Yes Yes Yes Qoint strips,1507.1.1.3/
RI e96th aJ l HT R905.1.1.3)
Yes
Colphene FR GR Yes Yes No No No Yes (joint strips,1507.1.1.3/
R905.1.1.3)
5.6.1 Adhesive-set tile is limited to use of the following Approved underlayment/tile-adhesive combinations.
TABLE 1A:ALLOWABLE TILE ADHESIVE/UNDERLAYMENT COMBINATlONS1
'Underlayment Adhesive Florida Product Approval .
Lastobond TU HT,Tri-Built S/A Dupont"Tile Bond"Roof Tile Adhesive" FL22525
HT TU Underlayment ICP Adhesives and Sealants"Polyset®AH-160" FL6332
5.7 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Underlayment Application
Substrates(designed to meet wind loads for project)
. , ,
Type Primer Material(s)
Lastobond Shield,Lastobond Pro (Optional)ASTM plywood,OSB or Southern Yellow Pine
HT-N,RESISTO SA SMOOTH PLY Deck/ D41,Elastocol Stick, (SYP)
40,Lastobond Shield HT, sheathing Elastocol Stick Zero
Lastobond Pro HT-S, ASTM D41 structural concrete
EnviroShield,Lastobond TU HT,
Tri-Built S/A HT TU Insulation (Optional)Elastocol Dens Deck Prime or SECUROCK Gypsum-
Stick Zero Fiber Roof Board
Underlayment,Lastobond Eaves
Protection Sheet,Lastobond 195, self-
Lastobond ECO,RESISTO LB1236, adhering
TRI-BUILT Sand-R SA Shingle
Underlayment,Grip-Rite Eave&
Valley Protector,TopShield ICE& Base Sheet (Optional)Elastocol ASTM D226,Type II felt or Modified Sopra-
WATER DEFENDER,RESISTO Stick Zero G
LB1244,Lastobond Smooth Seal
HT,Tri-Built Smooth HT S/A
Underlayment or Grip-Rite
Smooth Seal HT
Deck/ (Optional)ASTM plywood
D41
sheathing
ASTM D41 structural concrete
FR GR Col hene self-
p adhering Insulation (Optional)Elastocol Dens Deck Prime or SECUROCK Gypsum-
Stick Zero Fiber Roof Board
Base Sheet (Optional)Elastocol ASTM D226,Type II felt or Modified Sopra-
Stick Zero G
1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product ApprovalforOverturning Moment Resistance Performance.
NEMO ETC,LLC Evaluation Report 518010.06.09-1119
Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-1121
Soprema Roof Underlayments Revision 19:12/15/2020
Page 5 of 9
t `
NNEMOletc.
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Underlayment Application Substrates(designed to meet wind loads for project)
Type Primer Material(s)
Lastobond TU HT,Tri-Built S/A HT
TU Underlayment,RESISTO
LB1236,TRI-BUILT Sand-R SA self- Existing RESISTO EXTERIOR Existing sand-surfaced,glass-fiber surfaced,
Shingle Underlayment,Grip-Rite adhering substrate PRIMER mineral-surfaced or film-surfaced roof
Eave&Valley Protector or underlayment*
TopShield ICE&WATER
DEFENDER
*Final acceptance of any existing substrate in a reroof(tear-off)installation is at the discretion of the installer and the Authority
Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive Lastobond TU HT,Tri-Built S/A HT
TU Underlayment,RESISTO LB1236,TRI-BUILT Sand-R SA Shingle Underlayment,Grip-Rite Eave&Valley Protector or TopShield ICE&
WATER DEFENDER self-adhering underlayments,contact RESISTO technical support.
5.7.1 Soprema recommends priming with Elastocol Stick,Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof
cover is not slated for installation within 24 hours.
5.7.2 Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of the
self-adhering underlayment
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON-TILE prepared roof coverings,attachment shall be in accordance with
the manufacturer's installation instructions,but—for mechanically attached underlayments or base sheets-not
less than FBC 1507.1.1 or R905.1.1.
5.8.2 For use under the roof systems, attachment shall be in accordance with the manufacturer's installation
instructions, but—for mechanically attached base sheets-not less than:
• FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A,
Table 1(for Two-Ply Asphalt Applied Hot Mop Underlayment)
or
• Section 5.8.3 herein(for other underlayment systems).
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition. The Maximum Design Pressure
is the result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing
pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct-to-Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the
critical (highest)design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
#1 Maximum Design Pressure=-45.0 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional)Elastocol Stick,Elastocol Stick Zero or RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT,Tri-Built S/A HT TU Underlayment,self-adhered.
#2 Maximum Design Pressure=-67.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: Elastocol Stick Zero
Underlayment: Lastobond TU HT,Tri-Built S/A HT TU Underlayment,self-adhered.
NEMO ETC,LLC Evaluation Report S18010.06.09-1119
Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-R21
Soprema Roof Underlayments Revision 19:12/15/2020
Page 6 of 9
ONEMOletc.
#3 Maximum Design Pressure=-120.0 psf:
Deck: Min. 15/32-inch APA-rated CDX plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: (Optional)RESISTO EXTERIOR PRIMER
Base Ply: RESISTO SA SMOOTH PLY 40,self-adhered.
Underlayment: Lastobond TU HT,Tri-Built S/A HT TU Underlayment,self-adhered.
#4 Maximum Design Pressure=-150.0 psf:
Deck: Min.15/32-inch APA-rated BCX plywood(may be installed C-side up)to meet project requirements to
satisfaction of Authority Having Jurisdiction.
Primer: (Optional)RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT,Tri-Built S/A HT TU Underlayment,self-adhered.
#5 All other direct-deck, adhered underlayment systems beneath tile roof systems carry a Maximum Design
Pressure of-45 psf.
5.8.3.2 Mechanically-Attached Base Sheet:
The maximum design pressure for the selected assembly shall meet of exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A,Table 1A or the
critical (highest)design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
Alternatively,the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1
design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones
shall employ an attachment density designed by a qualified design professional to resist the elevated pressure
criteria. Commonly used methods are ANSI/SPRI WD1,FM Loss Prevention Data Sheet 1-29,Roofing Application
Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the
limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for
enhancements.
#6 Maximum Design Pressure=-60.0 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Modified Sopra-G mechanically attached with nails(FBC 1517.5.1)and tin caps(FBC 1517.5.2)spaced 6-
inch o.c.at the 4-inch laps and 6-inch o.c.in three(3),equally spaced rows in the center of the sheet.
Underlayment: Lastobond TU HT,Tri-Built S/A HT TU Underlayment,self-adhered
5.8.4 For use over insulation or coverboard and under mechanically attached prepared roof coverings, underlayment
attachment shall be in accordance with the manufacturer's installation instructions and attachment of the
insulation or coverboard shall be in accordance with the prepared roof covering manufacturer's Product
Approval.
5.9 Exposure Limitations:
TABLE 3: EXPOSURE LIMITATIONS
Underlayment Prepared Roof Cover Maximum
Installation Type Exposure(days)
Lastobond Eaves Protection Sheet,Lastobond 195,Lastobond Eco,RESISTO LB1236,TRI- Mechanically
BUILT Sand-R SA Shingle Underlayment,Grip-Rite Eave&Valley Protector,TopShield ICE 30
attached
&WATER DEFENDER or RESISTO LB1244
Lastobond TU HT,Tri-Built S/A HT TU Underlayment Adhesive-set tile roof 30
system
Lastobond Shield,Lastobond Pro HT-N,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT, Mechanically
Lastobond Pro HT-S,EnviroShield,Lastobond Smooth Seal HT,Tri-Built Smooth HT S/A 90
Underlayment or Grip-Rite Smooth Seal HT attached
Lastobond TU HT,Tri-Built S/A HT TU Underlayment or Colphene FR GR Mechanically 180
attached
NEMO ETC,LLC Evaluation Report 518010.06.09-1119
Certificate ofAuthorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-R21
Soprema Roof Underlayments Revision 29:12/15/2020
Page 7 of 9
NEMO�etc. -
5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct-deck tile roof assemblies,the
maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during
loading of the roof tiles.
TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECK TILE INSTALLATIONS
Underlayment Tile Profile Staging Method Maximum Slope
Flat Max.10-tile stack 6:12
Lugged Max.10-tile stack 5:12
Max.10-tile stack(bottom 2-tile stack shall be inverted,
followed by 8 tiles high on slope,as shown below) 6:12
Lastobond TU HT,Tri- - Q`
Built S/A HT TU ' I, �; W
Underlayment Lugged ~
gg
Colphene FR GR Flat Max.10-tile stack 5:12
Lugged Max.10-tile stack 6:12
6. INSTALLATION:
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation instructions
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application,and prime the substrate (if applicable).
6.2.1 Installation of RESISTO 1_61236,TRI-BUILT Sand-R SA Shingle Underlayment,Grip-Rite Eave&Valley Protector or
TopShield ICE&WATER DEFENDER self-adhering underlayment in a reroof(tear-off)application atop an existing
underlayment (per Table 2) requires priming of the existing substrate with RESISTO EXTERIOR PRIMER. Final
acceptance of any existing substrate in a reroof(tear-off) installation is at the discretion of the installer and the
Authority Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive
RESISTO 1_131236,TRI-BUILT Sand-R SA Shingle Underlayment,Grip-Rite Eave&Valley Protector or TopShield ICE
&WATER DEFENDER self-adhering underlayments,contact RESISTO technical support:
6.3 Lastobond TU HT, Tri-Built S/A HT TU Underlayment, Lastobond Shield, Lastobond Pro HT-N, RESISTO SA
SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, EnviroShield, Lastobond Eaves Protection Sheet,
Lastobond 195, Lastobond Eco, Lastobond Smooth Seal HT,Tri-Built Smooth HT S/A Underlayment, Grip-Rite
Smooth Seal HT, RESISTO 1_61236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip-Rite Eave & Valley
Protector,TopShield ICE&WATER DEFENDER,RESISTO LB1244 or Colphene FR GR:
6.3.1 Non-Tile Applications:
Shall be installed in compliance with requirements for an approved self-adhering underlayment(ASTM D1970) in
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering
to be installed,and the manufacturer's installation instructions.
When installed over a mechanically attached base sheet of FBC Approved ASTM D226,Type II felt the base sheet
shall be fastened in accordance with FBC 1507.1.1 or R905.1.1.
NEMO ETC,LLC Evaluation Report S18010.06.09-1119
Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-R21
Soprema Roof Underlayments Revision 19:12/15/2020
Page 8 of 9
ONEMOjetc.
6.3.2 Tile Applications:
Limited to Lastobond TU HT,Tri-Built S/A HTTU Underlayment or Colphene FR GR.
Shall be installed in compliance with the requirements for Self-Adhered Membrane set forth in FRSA/TRI Florida
High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition and the manufacturer's installation
instructions.
Refer to Section 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for tile staging limitations.
7. BUILDING PERM •
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
8. MANUFACTURING PLANTS:
Contact the named QA entity for manufacturing facilities covered by F.A.C.Rule 61G20-3 QA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
QUALITY9.
UL, LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com
-END OF EVALUATION REPORT-
NEW ETC,LLC Evaluation Report S18010.06.09-R19
Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-R21
Soprema Roof Underlayments Revision 19:12/15/2020
Page 9 of 9