HomeMy WebLinkAboutDrawingJ ^0
REEVEW ED
RECEIVED
APR 08 2021 � 'a LUCE
po_rmittir9 Department Hocc
51c. Lucie County o(4
F1kl, COPY--
1
vzl WA&*I
REPLACE DOORS IN 1 OPENING ONLY.
NEW DOORS TO BE IMPACT RESISTANT -
HURRICANE SHUTTERS NOT REQUIRED.
OPENING
PRODUCT
DESIGN
OPENING
SQ.
WIND
PRESSURES
APPROVAL
PRESSURES
COMMENTS
NO. WIDTH. HGT.
FTG.
ZONE
POS. NEG.
(N.O.A. #)
POS. NEG.
1 74 96
49.33
4
41.2 1 -45.0
FL17347.8
45.0 1 -45.0
FRONT ENTRY - LSMI
REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS.
NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS.
ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH MINIMUM 1/4" TAPCON SCREWS INTO CONCRETE
WITH A MINIMUM 1 1/4" PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS.
LESS THAN 30% OF STRUCTURE'S VALUE. NOT A RENOVATED BUILDING. EXEMPT FROM 2020 ENERGY CONSERVATION CODE.
SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES
DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES
MEAN ROOF HEIGHT = 13 FT 1 IN
COLVIN RESIDENCE
85 AQUA RA DRIVE
JENSEN BEACH, FLORIDA
DOOR REPLACEMENT PLAN