Date: March 31st, 2021
IASCE 7 Components & Cladding Wall Pressure Calculator
Prepared For:
7030 SW 16TH COURT
PEMBROKE PINES FL ( _
Project: COLVIN RESIDENCE \
Project Address:
85 AQUA RA DRIVE
JENSEN BEACH Florida Box for Engineer Seal Only-Original Rqd for Permit&Use
Frank Bennardo,PE FL46549 or Richard Neet,PE FL86488
The following has been considered in determining allowable stress design (ASD)wall opening pressures for the above-
referenced location.
ASCE:ASCE 7-16(7TH EDN FLORIDA BUILDING CODE,2020 FBC,
YFAN AOGT
2018 IBC)
Wind Velocity: 170 MPH
Exposure Category: D =❑ s "�`"'
Kd: 0.85 s O 5 ® s e ® s
Kzt: 1
Minimum Building Dimension: 170FT �a>k ELEVATION ka k 1
Mean Roof Height: 14FT LEASTHORIZO EN SION NTAL a ��DIYENS DN
DIM
Unit Elevation: FT s s
ROOF SLOPE: SLOPED (>=100) s ® °
®°
Number Of Openings: 1 WIN� ROOF m°
Shutter: NO FLOWS "EIGHT ®°
Mark: 1 5 4 INST ®°
Height Of Opening: 96 IN PLAN VIEW JEL-,FI..Ng p g� COMPLEX5,s —
Width Of Opening: 74 IN CORNERS
BUILDINGS>GO'ROOF HEIGHT
Zone:4 °50%OF LEAST HOMONTAL DIMENSION OR40%OF MEAN ROOF HEIGHT(MRH).WHICHEVER IS LESS
BUT NOT<G%OF LEASTHORRONTAL DIMENSION OR SFT."USE CORNEREONE S[FAT ALL IN QUESTION.
SHUTTER OPTION FORCES OUTPUTTO HEIGHT-NEIGHT/S.
Based on the above,the following ASD design pressures apply for the
opening marks which shall correspond with contractor-supplied building
y S r -
la out: CO L
a: 5.6 FT
Mark: 1
Wall Positve Pressure:41.2PSF Pali con.-
Wall Negative Pressure:-45PSF
Design pressure results are in accordance with the Building&ASCE 7 codes listed above for an ENCLOSED structure only
(Gcpi=+-0.18). Results are based on contractor-supplied data and are not field verified by this office. Input shall be verified
by others prior to permit&use. Selection of all components&their respective approvals shall be by others and are to be
within the ASD design pressure limitations stated herein. Results only valid with original or verifiable digital seal by a
licensed PE of this firm. For more information on any of the terms listed herein, or to use a design tool to evaluate your
openings,visit EngineeringExpress.com/Wind.