Loading...
HomeMy WebLinkAboutENERGY CALC (3)•ill G'1 1 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: RESENDIZ RESIDENCE Builder Name: Street: 4413 PRESSLER LANE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: ARTEMIO RESENDIZ Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2701.6 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Ext Insul, Exterior R=4.1 2300.20 ft2 b. Frame - Wood, Adjacent R=13.0 401.33 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 10. Ceiling Types (2406.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 2406.00 ft2 6. Conditioned floor area above grade (ft2) 2406 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(296.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Garage 6 200 a. U-Factor: Sgl, U=0.29 246.00 ft2 SHGC: SHGC=0.18 b. U-Factor: Sg1, U=0.30 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.18 a. Central Unit 46.5 SEER:16.00 c. U-Factor: Sg1, U=0.26 10.00 ft2 SHGC: SHGC=0.20 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 34.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 6.399 ft. Area Weighted Average SHGC: 0.181 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (2406.0 sqft.).) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 2406.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= f? 15. Credits None Total Proposed Modified Loads: 72.79 Glass/Floor Area: 0.123 PASS Total Baseline Loads: 81.54 I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Review of the plans and specifications covered by this a Code. calculation indicates compliance wt Q27this with the Florida Energy Code. PREPAID Y Before construction is completed DATE: - 3 0 building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes.' with the Florida Energy Code.- OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 3/31/2021 3:38 PM EnergyGaugeA® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: RESENDIZ RESIDENCE Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2406 Lot # Owner Name: ARTEMIO RESENDIZ Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 4413 PRESSLER LANE Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Detached FL, New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO BEACH MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2406 22375.8 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 M TOILET 24 223.2 No 0 1 Yes Yes Yes 2 M BATH 174 1618.2 No 0 1 Yes Yes Yes 3 MASTER BEDROO 260 2418 No 0 1 1 Yes Yes Yes 4 M W IC 168 1562.4 No 0 1 Yes Yes Yes 5 UTILITY 84 781.2 No 0 1 No Yes Yes 6 M HALL 40 372 No 0 1 No Yes Yes 7 DINING 126 1171.8 No 0 1 Yes Yes Yes 8 KITCHEN 252 2343.6 Yes 0 1 No Yes Yes 9 PANTRY 98 911.4 No 0 1 Yes Yes Yes 10 FOYER 81 753.3 No 0 1 Yes Yes Yes 11 CLST 4 20 186 No 0 1 No Yes Yes 12 BEDROOM 4 176 1636.8 No 0 1 1 Yes Yes Yes 13 LIVING ROOM 323 3003.9 No 0 1 Yes Yes Yes 14 HALLWAY 72 669.6 No 0 1 Yes Yes Yes 15 BEDROOM 3 169 1571.7 No 0 1 1 Yes Yes Yes 16 CLST 3 26 241.8 No 0 1 Yes Yes Yes 17 BATH 2 56 520.8 No 0 1 Yes Yes Yes 18 SINKS 2 48 446.4 No 0 1 No Yes Yes 19 BEDROOM 2 191 1776.3 No 0 1 1 Yes Yes Yes 20 CLST 2 18 167.4 No 0 1 Yes Yes Yes 3/31/2021 3:38 PM EnergyGaugeA® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation M TOILET loft 0 24 ft2 ---- 1 0 0 2 Slab -On -Grade Edge Insulation M BATH 19 ft 0 174 ft2 ___- 1 0 0 3 Slab -On -Grade Edge Insulation MASTER BEDRO 28 ft 0 260 ft2 ____ 1 0 0 4 Slab -On -Grade Edge Insulation M W IC 12 ft 0 168 ft2 ____ 1 0 0 5 Slab -On -Grade Edge Insulation UTILITY 1 ft 0 84 ft2 ____ 1 0 0 6 Slab -On -Grade Edge Insulation M HALL 1 ft 0 40 ft2 ____ 1 0 0 7 Slab -On -Grade Edge Insulation DINING 22 ft 0 126 ft2 ____ 1 0 0 8 Slab -On -Grade Edge Insulation KITCHEN 1 ft 0 252 ft2 ____ 1 0 0 9 Slab -On -Grade Edge Insulation PANTRY 14 ft 0 98 ft2 ____ 1 0 0 10SIab-On-Grade Edge Insulation FOYER 9 ft 0 81 ft2 ___- 1 0 0 11SIab-On-Grade Edge Insulation CLST 4 1 ft 0 20 ft2 ____ 1 0 0 12SIab-On-Grade Edge Insulation BEDROOM 4 28 ft 0 176 ft2 ____ 1 0 0 13SIab-On-Grade Edge Insulation LIVING ROOM 19 ft 0 323 ft2 ____ 1 0 0 14SIab-On-Grade Edge Insulation HALLWAY 1 ft 0 72 ft2 ____ 1 0 0 15SIab-On-Grade Edge Insulation BEDROOM 3 26 ft 0 169 ft2 ____ 1 0 0 16SIab-On-Grade Edge Insulation CLST 3 2 ft 0 26 ft2 ____ 1 0 0 17SIab-On-Grade Edge Insulation BATH 2 8 ft 0 56 ft2 ___- 1 0 0 18SIab-On-Grade Edge Insulation SINKS 2 1 ft 0 48 ft2 ___- 1 0 0 19SIab-On-Grade Edge Insulation BEDROOM 2 32.3 ft 0 191 ft2 ____ 1 0 0 20SIab-On-Grade Edge Insulation CLST 2 11 ft 0 18 ft2 ____ 1 0 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 2691 ft2 0 ft2 Light N 0.6 No 0.9 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 2406 ft2 N N 3/31/2021 3:38 PM EnergyGaugeA® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7 FORM R405-2017 INPUT 5UMMAKY GNEGKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) M TOILET 30 Blown 24 ft2 0.1 Wood 2 Under Attic (Vented) M BATH 30 Blown 174 ft2 0.1 Wood 3 Under Attic (Vented) MASTER BEDRO 30 Blown 260 ft2 0.1 Wood 4 Under Attic (Vented) M W IC 30 Blown 168 ft2 0.1 Wood 5 Under Attic (Vented) UTILITY 30 Blown 84 ft2 0.1 Wood 6 Under Attic (Vented) M HALL 30 Blown 40 ft2 0.1 Wood 7 Under Attic (Vented) DINING 30 Blown 126 ft2 0.1 Wood 8 Under Attic (Vented) KITCHEN 30 Blown 252 ft2 0.1 Wood 9 Under Attic (Vented) PANTRY 30 Blown 98 ft2 0.1 Wood 10 Under Attic (Vented) FOYER 30 Blown 81 ft2 0.1 Wood 11 Under Attic (Vented) CLST 4 30 Blown 20 ft2 0.1 Wood 12 Under Attic (Vented) BEDROOM 4 30 Blown 176 ft2 0.1 Wood 13 Under Attic (Vented) LIVING ROOM 30 Blown 323 ft2 0.1 Wood 14 Under Attic (Vented) HALLWAY 30 Blown 72 ft2 0.1 Wood 15 Under Attic (Vented) BEDROOM 3 30 Blown 169 ft2 0.1 Wood 16 Under Attic (Vented) CLST 3 30 Blown 26 ft2 0.1 Wood 17 Under Attic (Vented) BATH 2 30 Blown 56 ft2 0.1 Wood 18 Under Attic (Vented) SINKS 2 30 Blown 48 ft2 0.1 Wood 19 Under Attic (Vented) BEDROOM 2 30 Blown 191 ft2 0.1 Wood 20 Under Attic (Vented) CLST 2 30 Blown 18 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space o 1 S Exterior Concrete Block - Ext InsulM TOILET 4.1 6 0 9 4 56.0 ft2 0 0 0.6 0 2 W Exterior Concrete Block - Ext InsulM TOILET 4.1 4 0 9 4 37.3 ft2 0 0 0.6 0 3 S Exterior Concrete Block - Ext Insul M BATH 4.1 12 0 9 4 112.0 ft2 0 0 0.6 0 4 W Exterior Concrete Block - Ext Insul M BATH 4.1 7 0 9 4 65.3 ft2 0 0 0.6 0 5 N Exterior Concrete Block - Ext InsLKIASTER BE 4.1 14 0 10 4 144.7 ft2 0 0 0.6 0 6 W Exterior Concrete Block - Ext InsMASTER BE 4.1 14 0 10 4 144.7 ft2 0 0 0.6 0 7 S Exterior Concrete Block- Ext Insul M W IC 4.1 12 0 9 4 112.0 ft2 0 0 0.6 0 8 E Garage Frame - Wood M W IC 13 14 0 9 4 130.7 ft2 0 0.1 0.6 0 9 E Garage Frame - Wood UTILITY 13 7 0 9 4 65.3 ft2 0 0.1 0.6 0 10 E Garage Frame - Wood M HALL 13 4 0 9 4 37.3 ft2 0 0.1 0.6 0 11 N Exterior Concrete Block - Ext Insul DINING 4.1 8 0 9 4 74.7 ft2 0 0 0.6 0 12 W Exterior Concrete Block - Ext Insul DINING 4.1 14 0 9 4 130.7 ft2 0 0 0.6 0 13 S Garage Frame - Wood KITCHEN 13 11 0 9 4 102.7 ft2 0 0.1 0.6 0 14 E Exterior Concrete Block - Ext Insul PANTRY 4.1 14 0 9 4 130.7 ft2 0 0 0.6 0 15 S Garage Frame - Wood PANTRY 13 7 0 9 4 65.3 ft2 0 0.1 0.6 0 16 E Exterior Concrete Block - Ext Insul FOYER 4.1 9 0 9 4 84.0 ft2 0 0 0.6 0 17 N Exterior Concrete Block - Ext InstBEDROOM 4 4.1 9 0 9 4 84.0 ft2 0 0 0.6 0 18 E Exterior Concrete Block - Ext InstBEDROOM 4 4.1 14 0 9 4 130.7 ft2 0 0 0.6 0 19 S Exterior Concrete Block - Ext InstBEDROOM 4 4.1 5 0 9 4 46.7 ft2 0 0 0.6 0 20 W Exterior Concrete Block - Ext InsLklIVING ROO 4.1 19 0 10 4 196.3 ft2 0 0 0.6 0 3/31/2021 3:38 PM EnergyGaugeA® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Belowo nrntIn Space 21 S Exterior Concrete Block - Ext InsulHALLWAY 4.1 1 0 9 4 9.3 ft2 0 0 0.6 0 22 N Exterior Concrete Block - Ext InstBEDROOM 3 4.1 13 0 9 4 121.3 ft2 0 0 0.6 0 23 E Exterior Concrete Block - Ext InstBEDROOM 3 4.1 13 0 9 4 121.3 ft2 0 0 0.6 0 24 N Exterior Concrete Block - Ext Insul CLST 3 4.1 2 0 9 4 18.7 ft2 0 0 0.6 0 25 N Exterior Concrete Block - Ext Insul BATH 2 4.1 8 0 9 4 74.7 ft2 0 0 0.6 0 26 N Exterior Concrete Block - Ext InstBEDROOM 2 4.1 13 4 9 4 124.4 ft2 0 0 0.6 0 27 S Exterior Concrete Block - Ext InstBEDROOM 2 4.1 4 0 9 4 37.3 ft2 0 0 0.6 0 28 W Exterior Concrete Block - Ext InstBEDROOM 2 4.1 15 1 9 4 140.8 ft2 0 0 0.6 0 29 S Exterior Concrete Block - Ext Insul CLST 2 4.1 9 0 9 4 84.0 ft2 0 0 0.6 0 30 W Exterior Concrete Block - Ext Insul CLST 2 4.1 2 0 9 4 18.7 ft2 0 0 0.6 0 WINDOWS Orientation shown is the entered, Proposed orientation. V # Ornt Wall ID Frame Panes 1 S 3 Vinyl Low-E Single 2 W 4 Vinyl Low-E Single 3 W 6 Vinyl Low-E Single 4 W 12 Vinyl Low-E Single 5 E 14 Vinyl Low-E Single 6 E 16 Vinyl Low-E Single 7 E 18 Vinyl Low-E Single 8 W 20 Vinyl Low-E Single 9 W 20 Vinyl Low-E Single 10 E 23 Vinyl Low-E Single 11 N 25 Vinyl Low-E Single 12 W 28 Vinyl Low-E Single 0 e # Scope 1 W holehouse Floor Area 600 ft2 Method Proposed ACH(50) NFRC tiling Area 600 ft2 SLA .000413 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes U-Factor SHGC Imp 0.29 0.18 N 0.29 0.18 N 0.29 0.18 N 0.3 0.18 N 0.26 0.2 N 0.29 0.18 N 0.29 0.18 N 0.29 0.18 N 0.29 0.18 N 0.29 0.18 N 0.26 0.2 N 0.29 0.18 N GARAGE Exposed Wall Perimeter 11 ft INFILTRATION Overhang Area Depth Separation 12.0ft2 2ftOin 1ft4in 12.0ft2 2ft0in 1ft4in 30.0 ft2 2 ft 0 in 1 ft 4 in 40.0 ft2 2 ft 0 in 1 ft 4 in 4.0 ft2 2 ft 0 in 1 ft 4 in 48.0ft2 2ft0in 1ft4in 18.0ft2 2ft0in 1ft4in 45.0ft2 16ft0in 1ft4in 48.0 ft2 16 ft 0 in 1 ft 4 in 18.0ft2 2ft0in 1ft4in 6.0ft2 2ft0in 1ft4in 15.0ft2 2ft0in 1ft4in Int Shade Screening None None None None None None None None Drapes/blinds Exterior 5 None None None None None None None None None None None None None None Wall Height Exposed Wall Insulation 9 ft 13 CFM 50 ELA EgLA ACH ACH 50 2610.5 143.22 268.88 .1342 7 3/31/2021 3:38 PM EnergyGaugeA® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 16 46.5 kBtu/hr 1395 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS ---- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 200 ft2 Attic 20 ft2 Default Leakage Garage (Default) c(Default) c 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling Jan Feb Jan Feb H H Mar Mar Apr j May Jun rj Jul rjJun Aug rj �XjSep Nov �A Oct Nov Dec Dec VentinHeating Jan Feb l Mar Apr May Jun Jul Aug Sep Oct lOct xJ Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (W D) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (W D) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 BEDROOM 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 HALL 3/31/2021 3:38 PM EnergyGaugeA® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. ftz ft 0.3 CLST 5 Default(8 Ibs/sq.ft. ftz ft 0.3 HALL 3 Default(8 Ibs/sq.ft. ftz ft 0.3 BEDROOM 5 Default(8 Ibs/sq.ft. ftz ft 0.3 BATH 3 Default(8 Ibs/sq.ft. ftz ft 0.3 HALL 4 Default(8 Ibs/sq.ft. ftz ft 0.3 FAMILY ROOM Default(8 Ibs/sq.ft. ftz ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ftz ft 0.3 LAUNDRY Default(8 Ibs/sq.ft. ftz ft 0.3 OFFICE Default(8 Ibs/sq.ft. ftz ft 0.3 FOYER Default(8 Ibs/sq.ft. ftz ft 0.3 DINING Default(8 Ibs/sq.ft. ftz ft 0.3 MASTER BEDROO Default(8 Ibs/sq.ft. ftz ft 0.3 M W IC 1 Default(8 Ibs/sq.ft. ftz ft 0.3 M W IC 2 Default(8 Ibs/sq.ft. ftz ft 0.3 LIVING ROOM Default(8 Ibs/sq.ft. ftz ft 0.3 M TOILET Default(8 Ibs/sq.ft. ftz ft 0.3 M BATH 3/31/2021 3:38 PM EnergyGaugeA® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7 This document was created with Win2PDF available at http://www.win2pdf.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only. This page will not be added after purchasing Win2PDF.