Loading...
HomeMy WebLinkAboutAPPROVED Delach Energy CalcsFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION } Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: RJM DELACH 2786 Builder Name. RJM CUSTOM HOMES INC Street: 9640 FAIRWOOD COURT Permit Office: PORT ST LUCIE City, State, Zip: PORT ST LUCIE , FL, Permit Number: Owner. Jurisdiction: 601000 Design Location: FL, West Palm Beach County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) i 10. Wall typeV530,0 sgft.) Insulation Area a, Concrete Block - Int Insul, Exterior R=4.1 2250,00 ft2 2. Single family or multiple family Detached b. Frame - Wood, Adjacent R=11.0 280,00 fP 3. Number of units, if multiple family 1 c, N/A R= ft2 4. Number of Bedrooms 3 d. NIA ` R= ft2 11. Ceiling Types (2786.0 sgfL) Insulation Area 5. Is this a worst case? Yes a. Roof Deck (Unvented) R=20.0 2786.00 ft2 6. Conditioned floor area above grade (ft2) 2786 b. NIA R= ft2 ft2 Conditioned floor area below grade (ft2) 0 c. NIA R= R ft 2 7. Windows(400.3 sqft.) Description Area 12.; a.. SSup:upAttic, Ret: Attic, AH: Main 6 157.2 a. U-Factor: Sgl, U=0.52 400.25 ft2 SHGC: SHGC=0.30 b. U-Factor. NIA ft2 13, Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 46.5 SEER:14.50 c. U-Factor NIA ft2 SHGC: Area Weighted Average Overhang Depth: 8.506 ft. 14. Heating systems a. Electric Heat Pump kBtuthr Efficiency 46.5 HSPF:8.20 Area Weighted Average SHGC: 0.300 8, Skylights Area c. U-Factor.(AVG) WA ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (2786.0 sgft.) Insulation Area EF.0.920 a. Slab -On -Grade Edge Insulation R=0.0 2786.00 ft2 b. Conservation features b. N/A R= ft2 None c. NIA R= ft2 16. Credits Pstat Area: 0.144 Total Proposed Modified Loads: 92.31 PASS Glass/Floor Total Baseline Loads: 0,32 I hereby certify that the plans and specifications covered by Review of the plans and O� v14E S7AZ+� this calculation are in compliance wit the Florida Energy specifications covered by this indicates �+ ,ter 5 ` QA ''.•�`�� Code. calculation compliancelit with the Florida Energy Code. �„ Hrrr y% � :_" ,;:.� ,�tz PREPARED BY: DATE: _�� Before construction is completed this building will be inspected for compliance with Section 553.908 f h 0 I hereby certify that this buildln as designed, is in compliance Florida Statutes. mob with the Florida Energy Code. we T4�' OWNER/AGENTS BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403,3.2.1. ' - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 2/4/2021 11:01 AM EnergyGauge@ USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 5 FORM R405-2020 INPUT SUMMARY r.WI:^KI IAT RFPnPT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: RJM DELACH 2786 User 1 RJM CUSTOM HOMES INC PORT ST LUCIE 601000 Detached New (From Plans) Bedrooms: 3 Conditioned Area: 2786 Total Stories: 1 Worst Case: Yes Rotate Angle: 90 Cross Ventilation: Whole )louse Fan: Address Type: Street Address Lot # Block/Subdivision: PlatBook: Street: 9640 FAIRW000 COU County: St. Lucie City, State, Zip: PORT ST LUCIE , FL, CLIMATE / V Design Location TMY Site Design Temp 97.5 % 2.§ % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range Ft_, West Palm Beach FL WEST_PALM_BEAC 44 90 70 75 316 60 Medium BLOCKS I Number Name Area Volume 1 Biockl 2786 25074 SPACES Number Name Area Volume Kitchen Occupanto Bedrooms Inf l 10 Finished Cooled Heated 1 Main 2786 25074 Yes 8 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value '', Area Tile Wood Carpet 1 Slab -On -Grade Edge InsulaUo Main 214 ft 0 2786 ft2 --_ 0 0 1 ROOF I �! # Type Materials Roof Gable Roof Area Area Color Rad Barr Solar SA Emitt Emitt Deck Pitch Absor. Tested Tested insul. (deg) 1 Hip Composition shingles 3018 ft2 0 ft2 Medium N 0.96 No 0.9 No 20 22.62 ATTIC J Type Ventilation Vent Ratio (1 In) Area RBS IRCC 1 Partial cathedral cei Unvented 0 2786 112 N Y CEILING # Ceiling Type Space R-Value in$ Type Area Framing Frac Truss Type 1 Under Attic (Unvented) Main 0 Blown 2786 ft2 0.11 Wood 2/4/2021 11:01 AM EnergyGaugeV USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 5 GnRne 0Anr%-,)nnn INPIIT _ I IMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below tt rnt TA tAlaitIyn Space _ o 1 N=>E Exterior Concrete Block - Int Insul Main 4.1 66 10 660.0 ft' 0 0.15 0 2 E=>S Exterior Concrete Block - Int Insul Main 4.1 58 to 580.0 ft2 0 0.15 0 - 3 S=>W Exterior Concrete Black - Int Insul Main 4.1 42 10 420.0 ft2 0 0.15 0 4 W=>N Exterior Concrete Block - Int Insul Main 4.1 59 10 590.0 ft' 0 0.15 0 _ 5 E=>S Garage Frame - Wood Main 11 2 10 20.0 ft' 0.11 0.15 0 -6 N=>E Garage Frame - Wood Main 11 23 10 230.0 ft2 o.11 0.15 0 _ 7 W=>N Garage Frame - Wood Main 11 3 10 30.0 ft2 0.11 0.15 0 DOORS # Ornt Door Type Space Storms ; U-Value Width Area Ft In FHeightin 1 N=>E Wood Main None '' .46 2 8 8 21.3 ft2 WINDOWS Orientation shown Is the entered orientation => changed to Worst Case_ Wall Overhang # Omt 10 Frame Panes NFRC U-Factor SHGC imp Area Depth Separation Int Shade Screening 1 E=>S 2 Metal Single (Tinted) Yes 0.52 0.3 N 24.0 ft2 2 ft 0 in 1 ft 0 in None None 2 N=>E 1 Metal Single (Tinted) Yes 0.52 0.3 N ' 15.0 ft2 2 ft 0 in 1 ft 0 in None None 3 N-E 1 Metal Single (Tinted) Yes 0.52 0.3 N ? 15.0 ft2 2 ft 0 in 1 ft 0 in None None 4 E=>S 2 Metal Single (Tinted) Yes 0.52 0.3 N 48.0 ft2 30 ft 0 in 0 ft 6 in None None 5 N=>E 1 Metal Single (Tinted) Yes 0.52 0.3 N '', 64.0 ft2 11 ft 0 in 0 ft 6 in None None 6 N=>E 1 Metal Single (Tinted) Yes 0.52 0.3 N ',= 48.0 ft' 11 ft 0 in 0 It 6 in None None 7 E=>S 2 Metal Single (tinted) Yes 0.52 0.3 N 15.0 ft2 2 ft 0 in 1 ft 6 in None None 8 E=>S 2 Metal Single (Tinted) Yes 0.52 0.3 N 15.0 ft2 2 It 0 in 1 ft 6 in None None 9 E=>S 2 Metal Single (Tinted) Yes 0.52 0.3 N '' 6.0 ft2 2 It 0 in 1 ft 6 in None None 10 E=>S 2 Metal Single (Tinted) Yes 0.52 0.3 N ` 12.0 ft2 2 ft 0 in 1 ft 6 in None None 11 S=>W 3 Metal Single (Tinted) Yes 0.52 0.3 N 9.0 ft2 2 ft 0 in 1 ft 6 in None None 12 S=>W 3 Metal Single (Tinted) Yes 0.62 0.3 N ';, 15.0 ft2 2 ft 0 in 1 ft 6 in None None 13 S=>W 3 Metal Single (Tinted) Yes 0.52 0.3 N 48.0 fV 6 It 0 in 3 It 0 in None None 14 S=>W 3 Metal Single (Tinted) Yes 0.52 0.3 N 15.0 112 6 ft 0 in 0 It 6 in None None 15 S=>W 3 Metal Single (Tinted) Yes 0.52 0.3 N 15.0 ft' 2 ft 0 in 1 It 6 In None None 16 W=>N 4 Metal Single (Tinted) Yes 0.52 o.3 N 15.0 ft' 2 ft 0 in 1 ft 6 in None None 17 W=>N 4 Metal Single (Tinted) Yes 0.52 0.3 N 15.0 ft' 2 ft 0 in 1 ft 6 in None None 18 W=>N 4 Metal Single (tinted) Yes 0.52 0.3 N' 6.3 ft2 2 ft 0 in 1 ft 6 in None None GARAGE # Floor Area Ceiling Area Exposed Wail Perimeter Avg. Wall Height Exposed Wall Insulation 1 480 ft' 480 ft2 64 ft 9 It 1 2/4/2021 11:01 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5 FORM R405-2020 INPLIT RtIMMARY rHFrKI ICT''QCDnOT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .0004 2925.3 160.49 301.3 .1551 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None Singi HSPF:8.2 46.5 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ None Singi SEER: 14.546.5 kBtu/hr, 1395 cfm 0.75 1 sys#1 HOT WATER SYSTEM! # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.92 50 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEG Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None fts DUCTS / --- Supply ---- V # Location R-Value Area -- - Return — Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 157.2 ft Attic 49.3 ft$ Default Leaka a Main (Default) (Default) 9 1 TEMPERATURES' Programable Thermostat: Y Cooling [X� Jan Feb X Mar Heating Jan Feb ;Mar Venting Jan Feb lx7 Mar Ceiling Fans: A r Ma Jun [X ul X Au Se Apr J MaY ri Jun [ul AuSep W Apr J may Jun ( JJJJJJui Aug Se Oct v Oct Nov Oct HNo Nov Dec (X Dec [ Dec 2/4/2021 11:01 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5 1 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 58 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 fib 68 68 68 68 68 68 68 66 66 MECHANICAL VENTILATION Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System None 0 0 0 1 - Electric Heat Pump 0% 1 - Central Unit MASS Mass Type Area Thickness Furniture Fraction Space Default 8 lbs/s ,ft, 0 ft2 0 ft I 0.3 Main 2/4/2021 11:01 AM EnergyGauge(D USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 5