Loading...
HomeMy WebLinkAboutAPPROVED Energy Calcs Revised (1)FORM R405-2020 FLORIDA ENERGY EFFICIENCY CO E FOR BUILDING CONSTRUCTION Florida Department of Business and Professiona Regulation - Residential Performance Method Project Name: RJM DELACH 2786 Builder Name: RJM CUSTOM HOMES INC Street: 9640 FAIRWOOD COURT Permit Office: PORT ST LUCIE City, State, Zip: PORT ST LUCIE . FL, Permit Number: Owner: _ Jurisdiction: _._60 000 Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type$2530.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul. Exterior R=4.1 2250.00 ft' b. Frame -Wood, Adjacent R=11.0 280.00 ft' 3. Number of units, if multiple family 1 c. NIA R= ft' 4. Number of Bedrooms 3 d. NIA R= ft' 5. is this a worst case? Yes 11. Ceiling Types (2786.0 sgft.) Insulation Area a. Roof Deck (Unvented) R=20.0 2786.00 ft' 6. Conditioned floor area above grade (ft') 2786 b. N/A R= ft' Conditioned floor area below grade (W) 0 c. NIA R= ft' 7. Windows(400.3 sqft.) Description Area 12. Ducts R ft' a. Sup: Attic, Ret: Attic, AH: Main 6 157.2 a. U-Factor: Sgl, U=0.52 400.25 ft' SHGC: SHGC=0.30 b. U-Factor: NIA ft' 13. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 46.5 SEER:14.50 c. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 8.506 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.300 a. Electric Heat Pump 46.5 HSPF:8.20 8. Skylights Area c. U-Factor:(AVG) NIA ft2 15. Hot water systems SHGC(AVG). NIA a. Electric Cap: 50 gallons 9. Floor Types (2786.0 sqft.) Insulation Area EF: 0.920 a. Slab -On -Grade Edge Insulation R=0.0 2786.00 ft' b. Conservation features b. N/A R= ft' None c. N/A R= ft' 16. Credits Pstat Total Proposed ModifiedLoads: Glass/Floor Area: 0.144 82.28 PASS Total Baseline Lo ds: 82.46 I hereby certify that the plans and specifications covered by Review of the plans and S14E Sz, this calculation are in compliance ith the FI 'da Ene y specifications covered by this v = Q Code. calculation indicates compliance -- with the Florida Energy Code. E•. ru,rr,; 1€''.;;.„ p �� PREPARED BY: Before construction is completed' DATE: -_ 2- this building will be inspected for 1- mpliance with Section 553.908 I hereby certify that this building, as desig ' is in compliance lorida Statutes. with the Florida Energy Code, CODS OWNER/AGENT: BUILDING OFFICIAL: DATE: ATE: _ - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed In accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4,1.1 and this project requires an envelope leakage test report with envelope leakage no greater tha 17.00 ACH50 (R402.4.1.2). 3/16/2021 1:41 PM EnergyGauge© USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: RJM DELACH 2786 Bedrooms: 3 User Conditioned Area: 2786 Total Stories: 1 1 Worst Case: Yes RJM CUSTOM HOMES INC Rotate Angle: 90 PORT ST LUCIE Cross Ventilation: 601000 Whole House Fan: Detached New (From Plans) Address Type: Street Address Lot # Block/Subdivision: PlatBook: Street: 9640 FAIRWOOD COU County: St. Lucie City, State, Zip: PORT ST LUCIE , FL, CLIMATE J Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Block1 2786 25074 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2786 25074 Yes 8 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 214 ft 0 2786 ft2 ___ 0 0 1 ROOF v # Type . — Roof Gable Roof na sArea Color Rad Barr Solar SA Emitt Emitt Deck Pitch Absoc Tested Tested Insul. (deg) 1 Hip Metal 3018 0 ft' Medium ATTIC N 0.96 No 0.9 No 20 22.62 J # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Partial cathedral cei Unvented 0 2786 ft2 N Y CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) Main 0 Blown 2786 ft2 0.11 Wood 3/16/2021 1:41 PM EnergyGaugeO USA 7.0.00 - FlaRes2020 FOC 7th Edition (2020) Compliant Software Page 2 of 5 FORM R405-2020 INPUT SUMMARY GHE KLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ 1 N=>E Exterior Concrete Block - Int Insul Main 4.1 66 10 660.0 ft2 0.15 0 _ 2 E=>S Exterior Concrete Block - Int Insul Main 4.1 58 10 580.0 ft2 0 0.15 0 - 3 S=>W Exterior Concrete Block - Int Insul Main 4.1 42 10 420.0 112 0 0.15 0 4 W=>N Exterior Concrete Block - Int Insul Main 4.1 59 10 590.0 ft2 0 0.15 0 - 5 E=>S Garage Frame - Wood Main 11 2 10 20.0 ft2 0.11 0.15 0 6 N=>E Garage Frame - Wood Main 11 23 10 230.0 ft2 0.11 0.15 0 7 W=>N Garage Frame - Wood Main 11 3 10 30.0 ft2 0.11 0.15 0 ,f # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>E Wood Main None .46 2 8 8 21.3 ft2 WINDOWS shown is the entered orientation / # Ornt Wall ID Frame Panes 1 E=>S 2 Metal Single (Tinted) 2 N=>E 1 Metal Single (Tinted) T 3 N=>E 1 Metal Single (Tinted) r 4 E=>S 2 Metal Single (Tinted) _ 5 N=>E 1 Metal Single (Tinted) 6 N=>E 1 Metal Single (Tinted) _ 7 E=>S 2 Metal Single (Tinted) _ 8 E=>S 2 Metal Single (Tinted) _ 9 E=>S 2 Metal Single (Tinted) _ 10 E=>S 2 Metal Single (Tinted) _ 11 S=>W 3 Metal Single (Tinted) _ 12 S=>W 3 Metal Single (Tinted) - 13 S=>W 3 Metal Single (Tinted) _ 14 S=>W 3 Metal Single (Tinted) _ 15 S=>W 3 Metal Single (Tinted) _ 16 W=>N 4 Metal Single (Tinted) _ 17 W=>N 4 Metal Single (Tnted) _ 18 W=>N 4 Metal Single (Tinted) # Floor Area Ceiling Ar 1 480 ft2 480 ft2 :hanged to Worst Case. Overhang NFRC U-Factor 5 AGC Imp Area Depth Separation Int Shade Screeni, Yes 0.52 D.3 N 24.0 ft2 2 ft 0 in 1 ft 0 in None None Yes 0.52 D.3 N 15.0 ft2 2 ft 0 in 1 ft 0 in None None Yes 0.52 0.3 N 15.0 ft2 2 ft 0 in 1 ft0 in None None Yes 0.52 0.3 N 48.0 112 30 ft 0 in 0 ft 6 in None None Yes 0.52 0.3 N 64.0 ft2 11 ft 0 in 0 ft 6 in None None Yes 0.52 I0.3 N 48.0 ft2 11 ft 0 in 0 ft 6 in None None Yes 0.52 0.3 N 15.0 ft2 2 ft 0 in 1 ft 6 in None None Yes 0.52 0.3 N 15.0 ft2 2 ft 0 in 1 ft6 in None None Yes 0.52 0.3 N 6.0 ft2 2 ft 0 in 1 ft 6 in None None Yes 0.52 0.3 N 12.0 ft2 2 ft 0 in 1 ft 6 in None None Yes 0.52 10.3 N 9.0 ft2 2 ft 0 in 1 ft 6 in None None Yes 0.52 p.3 N 15.0 ft2 2 ft 0 in 1 ft 6 in None None Yes 0.52 0.3 N 48.0 ft2 6 ft 0 in 3 ft 0 in None None Yes 0.52 0.3 N 15.0 ft2 6 ft 0 in 0 ft 6 in None None Yes 0.52 0.3 N 15.0 ft2 2 ft 0 in 1 ft 6 in None None Yes 0.52 0.3 N 15.0 ft2 2 ft 0 in 1 ft 6 in None None Yes 0.52 0.3 N 15.0 ft' 2 ft 0 in 1 ft 6 in None None Yes 0.52 0.3 N 6.3 ft2 2 ft 0 in 1 ft 6 in None None GARAGE ea Exposed WMll Perimeter Avg. Wall Height Exposed Wall Insulation 64 fit 9 ft 1 3/16/2021 1:41 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FOC 7th Edition (2020) Compliant Software Page 3 of 5 FORM R405-2020 IMP[ IT Al IL41MAPV ['_1-t;=rV1 ICT 0=Dr10r INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .0004 2925.3 100.49 301.3 .1324 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None _ Singl HSPF:8.2 46.5 kBtu/hr 1 _ sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow S_HR Block Ducts 1 Central Unit! None Singl SEER: 14.5 46.6 kStulhr 1395 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.92 50 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name System Model Collector Storage Collector Model # Area Volume FEF None None � ft: DUCTS / -- Supply --- V # Location R-Value Area --- Return --- Air CFM 25 CFM25 Location Area Leakage Type Handier TOT OUT ON RLF HVAC # Heat Cool 1 Attic 6 157.2 ft Attic 49.3 ftz De ault Leakage Main (Default) (Default) 1 1 TEMPERATURES Programabie Thermostat: Y Conlin j Jan Feb jj jj Mar Heating [XJan Feb (X] Mar [[ Jan Feb [X Mar Ceiling Fans: A r May [X Jun X Julrj Au Se Oct j Nov Pr May [ Jun 4 Jul Au�XjSep Oct X) Nov [x) A r Ma [ Jun [ Jul Aug Se [X Oct (Xj Nov Dec f X DeVenting [ Dec 3/16/2021 1:41 PM EnergyGauge4D USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST RFPnRT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 8 10 11 12 Cooling (WD) AM 78 78 78 78 8 78 78 78 80 80 80 80 PM 80 60 78 78 8 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 8 78 78 78 78 78 78 78 PM 78 78 78 78 8 78 78 78 78 78 78 78 Heating (1ND) PM 68 68 68 8 68 68 68 68 68 68 68 68 68 68 66 56 Heating (WEH) AM 66 66 66 66 6 68 68 68 68 68 68 68 PM 68 68 68 68 8 68 68 68 68 68 66 66 MECHANICAL I ENTILATION Type T Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System Hone 0 0 1 - Electric Heat Pump 0% 1 - Central Unit MASS Mass Type Area Thick ess Furniture Fraction Space Default(8 Ibsls .ft. 0 ft2 0 0.3 Main 3/16/2021 1:41 PM EnergyGouge@) USA 7.0.00 - FlaRes2020 F�,C 7th Edition (2020) Compliant Software Page 5 of 5 FORM R405-2020 ,: � -,-, L-A : bJ RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative (Performance) Method Applications for compliance with the 2020 Florida Bu /ding Code, Energy Conservation via the Residential Simulated Performance Alternative shall t clude: This checklist Form R405-2020 report Cjr Input summary checklist that can be used for field verification (usually four pages/may be greater) Energy Performance Level (EPL) Display Card (cne page) �HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7 Mandatory Requirements (five pages) Required prior to CO: ❑ Air Barrier and Insulation Inspection Component Criteria checklist (Table R402.4.1.1 - one page) ❑ A completed 2020 Envelope Leakage Test Report (usually one page); exception in R402.4 allows dwelling units of R-2 Occupancies and multiple attached single family dwellings to comply with Section C402.5 ❑ If Form R405 duct leakage type indicates anyMing other than "default leakage" then a completed 2020 Duct Leakage Test Report - Performanc Method (usually one page) 3/16/2021 1:41:35 PM EnergyGaugeB USA T0.00 - FlaRes202O FOC 7th Edition (2020) Compliant Software Page 1 of 1