Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutAPPROVED FL2569-R20 Resisto LB1236 ib a
� tt
ss
BCIS Home - Log In User Registration ( Hot Topics Submit Surcharge Stats&Facts Publications i Contact Us ( BCIS Site Map 4 Links'` Search
Product Approval
USER:Public User
Product Approval Menu>Product or Application Search>AUplication LisYList>Application Detail
FL# FL2569-R20
Application Type vision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer Soprema,Inc.(Canada)
Address/Phone/Email 1640 rue Haggarty
Drummondville, NON-US 00000
(819)478-2400
memathieu@soprema.ca
Authorized Signature Marc-Etienne Mathieu
memathieu@soprema.ca
Technical Representative Marc-Etienne Mathieu
Address/Phone/Email 1688 Jean-Berchmans-Michaud
Drummondville, NON-US 00000
(819)478-2400 Ext3327
memathieu@soprema.ca
Quality Assurance Representative lean-Francois Cote, Ph.D.
Address/Phone/Email 1640 rue Haggarty
Drummondville
(888)811-3145
jfcote@soprema.ca
Category Roofing
Subcategory (�Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
si ? Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J. M. Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 04/10/2023
Validated By John W. Knezevich, PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL2569 R20 COI 2020 01 COI NIEMINEN.p-df
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2015
ASTM D4798 2011
ASTM D6163 2015
FM 4474 2011
FRSA/TRI Sixth Edition 2018
UL1897 2012
Equivalence of Product Standards
Certified By
Sections from'the Code
Product Approval Method Method 1 Option D
Date Submitted 09/19/2020
Date Validated 09/22/2020
Date Pending FBC Approval 09/29/2020
Date Approved 12/15/2020
Date Revised 12/16/2020
Summary of Products
F..# Model,Plumber or Dame _..__....... .......Description._........._._.................._.......
__...__
2569.1 Soprema Roof Underlayments Self adhering roof underiayments W Y - _ -y✓ _.._ _...._...;_.......... .._........................................ ..... . ........
Limits of Use Installation Instructions E
Approved for use in HVHZ: No FL2569 R20 II 2020 09 17 FINAL ER FL2569-R20.pdf l
i
Approved for use outside HVHZ:Yes Verified By: Robert Nieminen, P.E. PE-59166
Impact Resistant: N/A Created by Independent Third Party:Yes
Design Pressure: +N/A/-150 Evaluation Reports
Other: 1.)Refer to ER Section 5 for Limits of Use. 2.)The FL2569 R20 AE 2020 09 17 FINAL ER FL2569-R20.pdf
design pressure noted herein pertains to underlayment systems Created by Independent Third Party:Yes
used beneath adhesive-set tile systems. Refer to ER Section `
5.6.4 for details. !
Ltacic d�Fx€
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Lopyri 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
' FOR zuFzck
,. redtt Cara'
FIVIE etc.
Certificate of Authorization#32455
353 Christian Street,Unit#13
Oxford,CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
Soprema,Inc. Evaluation Report S18010.06.09-1118
1640 rue Haggerty FL2569-1120
Drummondville,Quebec J2C 5138 Canada Date of Issuance:06/15/2009
(819)478-2400 Revision 18:09/17/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 71h Edition(2020)Florida Building Code sections noted herein.
DESCRIPTION: Soprema Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.1.1.
CONTINUED COMPLIANCE:This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance or production facility location(s)changes,or Code provisions that relate to the product(s)change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT:The Florida Product Approval Number (FL#) preceded by the words "NEMO I etc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer
or its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by: «t -
sP� G i fi
uf...r.-wall,fir ,r y
Robert J.M. Nieminen,P.E. J- ,
�,:, atO�r The facsimile seal appearing was authorized by Robert
�,;���;i,ti. ;r... Nieminen,P.E.on 09/17/2020.This does not serve as
Florida Registration No.59166,Florida DCA ANE1983 = ,;,;; an electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEW ETC,LLC does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEW ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
©2019 NEMO ETC,LLC
ONEMO etc.
ROOFING COMPONENT EVALUATION:
d•
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Roof Underlayments,as produced by Soprema,have demonstrated compliance with the
following sections of the 7t"Edition(2020)Florida Building Code through testing in accordance with the following
Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth
herein.
Seeti�rt `' �"ro es^� `Standard �1(ear �'
1504.3.1 Wind resistance FM 4474 2011
1504.3.1 Wind resistance UL 1897 2012
1507.1.1,1507.2.4,1507.2.9.2 Material standard ASTM D1970 2015
/R905.1.1,R905.2.8.2 .
1507.3.3/R905.3.3 Material standard FRSA/TRI,Sixth Edition 2018
1507.11.2/R905.11.2 Material standard ASTM D6163 2015
TAS 110 Accelerated Weathering ASTM D4798 2011
ERD(TST6049) Wind Resistance 2778.07.05 07/15/2005
ERD(TST6049) ASTM D1970/TAS 110(QC) S31370.03.10-1-R1 04/07/2010
ERD(TST6049) FRSA/TRI 04-12(OH) S11150.05.09-R2 10/05/2010
ERD(TST6049) ASTM D1970(OH) S37210.11.11 11/09/2011
ERD(TST6049) ASTM D1970(MS) 537210.12.11 12/01/2011
ERD(TST6049) ASTM D1970(MS) S40540.02.13-1 02/19/2013
ERD(TST6049) FRSA/TRI 04-12(MS) 543530.02.14-1-R1 02/21/2014
ERD(TST6049) ASTM D1970(BC) S44870.04.14-2 04/02/2014
ERD(TST6049) ASTM D1970(QC) S44870.04.14-3 04/02/2014
ERD(TST6049) ASTM D1970(OH) S44870.04.14-1 04/10/2014
ERD(TST6049) ASTM D1970(MS) S44870.04.14-4 04/10/2014
ERD(TST6049) ASTM D1970(OH) S40540.10.14 10/31/2014
ERD(TST6049) Tensile Adhesion/Long Term Aging SOPC-SC7645.02.15 02/13/2015
ERD(TST6049) Accelerated Weathering SOPC-SC8520.04.14 04/27/2015
ERD(TST6049) Wind Resistance SOPC-SC14045.05.17-R1 06/07/2017
M-D(CER1592) HVHZ Compliance 18-0329.03 06/28/2018
ICC-ES(EVL2396) 2015 IBC Compliance ESR-1524 03/01/2017
NEMO(TST6049) ASTM D1970/TAS 110(QC) SOPC-SC8970.08.15-RI 04/25/2018
MEMO(TST6049) Wind Resistance 4-SOPC-18-003.08.18 08/27/2018
NEMO(TST6049) ASTM D4798/D1970(OH&MS) 4S-SOPC-18-002.05.19.A 05/31/2019
NEMO(TST6049) Tensile Adhesion/Long Term Aging 4p-DOW-I9-SSLAP-01.A.R2 02/10/2020
NEMO(TST6049) Peel adhesion(existing underlayments) 4j-SOPC-I9-SSUDL-04.A 03/12/2020
PRI(TST5878) ASTM D1970(MS) SOP-064-02-01 12/03/2013
Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015
UL,LLC(QUA9625) Quality Control MLA File No.R27605 05/08/2019
UL,LLC(QUA9625) Quality Control Service Confirmation 06/29/2020
MEMO ETC,LLC Evaluation Report S18010.06.09-R18
Certificate of Authorization#32455 7"'EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-R20
Soprema Roof Underlayments Revision 18:09/17/2020
Page 2 of 8
IVEnn®'etc.
�roduc� �latertal 3 � ��� z
Standard Plans) r�pt�
Desc �n
4.1 Lastobond TU HT ASTM D1970 and Gulfport,MS self-adhering,non-woven polyester fabric
FRSA/TRI 09-18 surfaced,SBS modified bitumen roof
underlayment
4.2 Lastobond Shield ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS
modified bitumen roof underlayment available in
two widths;36 and 45 inch
4.3 RESISTO SA SMOOTH PLY ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS
40 modified bitumen roof underlayment
4.4 Lastobond Shield HT ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,high
temperature,SBS modified bitumen roof
underlayment
4.5 Lastobond Pro HT-N ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS
modified bitumen roof underlayment available in
two widths;36 and 45 inch
4.6 Lastobond Pro HT-S ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,high
temperature,SBS modified bitumen roof
underlayment
Drummondville,QC self-adhering,woven polyethylene surfaced,high
4.7 EnviroShield ASTM D1970
temperature,SBS modified bitumen roof
underlayment
4.8 Lastobond 195 ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,sand-
Wadsworth,OH surfaced,SBS modified bitumen roof
underlayment
4.9 Lastobond Eaves ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,sand-
Protection Sheet Wadsworth,OH surfaced,SBS modified bitumen roof
underlayment
4.10 Lastobond Eco ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
4.11 Lastobond Smooth Seal ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film-
HT Wadsworth,OH surfaced,SBS modified bitumen roof
underlayment
4.12 PrimeSource Grip-Rite ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film-
Smooth Seal HT Wadsworth,OH surfaced,SBS modified bitumen roof
underlayment
013 >RESISTO LB1236 ASTM D1970 Drummondville,QC self-adhering,glass mat reinforced,sand-
Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
4.14 PrimeSource Grip-Rite ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
Eave&Valley Protector Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
4.15 SRS TopShield ICE& ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
WATER DEFENDER Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
4.16 RESISTO LB1244 ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
NEIVlO ETC'LLC Evaluation Report S18010.06.09-R38
Certificate of Authorization#32455 7"'EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-R20
Soprema Roof Underlayments Revision 18:09/17/2020
Page 3 of 8
".. 11YE M0 etc.
7777777777777
Product iVlatrt�l t?fangs) Des�Piptron
4.17 Colphene FR GR ASTM D6163 Gulfport,MS self-adhering,fiberglass reinforced,granule-
Wadsworth,OH surfaced,SBS modified bitumen roof
underlayment
5.1 This is a building code evaluation. Neither MEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer
of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami-
Dade Counties).
5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.5 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers:
i
3
1fz AboF CpVEP,Cep t lOAIS
Clay and Conorete Tti�
ltsphaft Metal Slate or wood
unddir ayment SO�mgies x' Its6.�sJ a Slate Typ
(tsoz) Mechanical Atlheslue Paricis Shnoles Sh(ngles �hinles
Lastobond TU HT Yes Yes Yes Yes Yes
See 5.6.1 Yes Yes Yes (joint strips,1507.1.1.3 (joint strips,1507.1.1.3
/R905.1.1.3) /R905.1.1.3)
Lastobond Shield/Pr.HT-N Yes Yes
/RESISTO SA SMOOTH PLY Yes No No No No Yes (joint strips,1507.1.1.3 (joint strips,1507.1.1.3
40 /R905.1.13) /R905,1.1.3)
Lastobond Shield HT/Pro Yes Yes
HT-S Yes No No Yes Yes Yes (joint strips,1507.1.1.3 Qoint strips,1507.1.1.3
/R905.1.1.3) /R905.1.1.3)
Yes Yes
EnviroShield Yes No No Yes Yes Yes (joint strips,1507.1.1.3 (joint strips,1507.1.1.3
/R905.1.1.3) /R905.1.1.3)
Lastobond Eaves Protection Yes Yes
Sheet Lastobond 195 Yes No No No No Yes p (joint strips,1507.1.1.3
/ (joint stri s,1507.1.1.3
/R905.1.1.3) /R905.1.1.3)
Lastobond ECO /RESI�
LB1236,Grip-Rite Eave& Yes Yes
baelly Protector/TopShield Yes No No No No Yes (joint strips,1s07.1.1.3 (joint strips,1507.1.1.3
ICE&WATER DEFENDER/ /R905.1.1
RESISTO LB1244 .3) /R905.1.1.3)
Lastobond Smooth Seal HT/ Yes Yes
Grip-Rite Smooth Seal HT Yes No No Yes Yes Yes (joint strips,1507.1.1.3 (joint strips,1507.1.1.3
/R905.1.1.3) /R905.1.1.3)
Yes Yes
ColpheneFRGR Yes Yes No No No Yes joint strips,1507.1.1.3 (joint strips,1507.1.1.3
/R905.1.1.3) /R905.1.1.3)
NEMO ETC,LLC Evaluation Report S18010.06.09-R18
Certificate of Authorization#32455 7`"EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-R20
Soprema Roof Underlayments Revision 18:09/17/2020
Page 4 of 8
ONEMOletc.
5.6.1 Adhesive-set tile is limited to use of the following Approved underlayment/tile-adhesive combinations.
Urtd rlayenetrte'. Adhesrue
flprrda Product Approya(
Lastobond TU HT Dupont"Tile BondTM"Roof Tile Adhesive" FL22525
ICP Adhesives and Sealants"Polyset®AH-160" FL6332
5.7 Allowable Substrates:
ZYUB5�1tATE Qlftt(SS l tR AC?1Et)r U lDi3EkYMt iVTS
,. .. f
i nder9ayrnent` Application Substrates'(desrgnee!to meet wrnd;loads for project
F ;
Pruner Mateiial(s� ..-
Lastobond Shield,Lastobond Pro (Optional)ASTM
HT-N,RESISTO SA SMOOTH PLY eck/ D41,Elastocol Stick, plywood,OSB or Southern Yellow Pine
40,Lastobond Shield HT, sheathing Elastocol Stick Zero (SYP)
Lastobond Pro HT-S, ASTM D41 structural concrete
EnviroShield,Lastobond TU HT,
Lastobond Eaves Protection Insulation (Optional)Elastocol Dens Deck Prime or SECUROCK Gypsum-
Sheet, nd 195,L a s t o b a n self- Stick Zero Fiber Roof Board
ECO ESISTO LB123 Grip-Rite adhering
Eave&Va ey Protector,
TopShield ICE&WATER Base Sheet (Optional)Elastocol ASTM D226,Type If felt or Modified Sopra-
DEFENDER,RESISTO LB1244, Stick Zero G
Lastobond Smooth Seal HT or
Grip-Rite Smooth Seal HT
Deck/ (Optional)ASTM Plywood
sheathing D41
Colphene FIR GR
self- ASTM D41 structural concrete
adhering Insulation (Optional)Elastocol Dens Deck Prime or SECUROCK Gypsum-
Stick Zero Fiber Roof Board
Base Sheet (Optional)Elastocol ASTM D226,Type II felt or Modified Sopra-
Stick Zero G
RESISTO LB1236,Grip-Rite Eave Existing sand surfaced,glass-fiber surfaced,
&Valley Protector or TopShield self- Existing RESISTO EXTERIOR
adhering substrate PRIMER mineral-surfaced or film-surfaced roof
ICE&WATER DEFENDER underlayment*
*Final acceptance of any existing substrate in a reroof(tear-off)installation is at the discretion of the installer and the Authority
Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive RESISTO LB1236,Grip-Rite Eave&
Valley Protector or TopShield ICE&WATER DEFENDER self-adhering underlayments,contact RESISTO technical support.
5.7.1 Soprema recommends priming with Elastocol Stick,Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof
cover is not slated for installation within 24 hours.
5.7.2 Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of the
self-adhering underlayment
'Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC'LLC Evaluation Report S18010.06.09-1118
Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-1120
Soprema Roof Underlayments Revision 18:09/17/2020
Page 5 of 8
NEMQ,etc.
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON-TILE prepared roof coverings,attachment shall be in accordance with
the manufacturer's installation instructions,but—for mechanically attached underlayments or base sheets-not
less than FBC 1507.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation
instructions,but—for mechanically attached base sheets-not less than:
0 FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A,
Table 1(for Two-Ply Asphalt Applied Hot Mop Underlayment)
or
® Section 5.8.3 herein(for other underlayment systems).
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition. The Maximum Design Pressure
is the result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing
pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct-to-Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida Nigh Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition,Appendix A,Table 1A or the
critical(highest)design pressure determined in accordance with FBC 1609 or F8C Residential Chapter 3.
#1 Maximum Design Pressure=-45.0 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional)Elastocol Stick,Elastocol Stick Zero or RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT,self-adhered.
#2 Maximum Design Pressure=-67.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: Elastocol Stick Zero
Underlayment: Lastobond TU HT,self-adhered.
#3 Maximum Design Pressure=-120.0 psf:
Deck: Min. 15/32-inch APA-rated CDX plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: (Optional)RESISTO EXTERIOR PRIMER
Base Ply: RESISTO SA SMOOTH PLY 40,self-adhered.
Underlayment: Lastobond TU HT,self-adhered.
#4 Maximum Design Pressure=-150.0 psf: -
Deck: Min.15/32-inch APA-rated BCX plywood(may be installed C-side up)to meet project requirements to
satisfaction of Authority Having Jurisdiction.
Primer: (Optional)RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT,self-adhered.
#5 All other direct-deck, adhered underlayment systems beneath the roof systems carry a Maximum Design
Pressure of-45 psf.
NEMO ETC,LLC Evaluation Report 518010.06.09-R18
Certificate of Authorization#32455 7""EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-R20
Soprema Roof Underlayments Revision 18:09/17/2020
Page 6 of 8
NEMO I etc.
5.8.3.2 Mechanically-Attached Base Sheet:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A,Table 1A or the
critical (highest)design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
Alternatively,the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1
design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones
shall employ an attachment density designed by a qualified design professional to resist the elevated pressure
criteria. Commonly used methods are ANSI/SPRI WD1,FM Loss Prevention Data Sheet 1-29,Roofing Application
Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the
limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for
enhancements.
#6 Maximum Design Pressure=-60.0 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Modified Sopra-G mechanically attached with nails(FBC 1517.5.1)and tin caps(FBC 1517.5.2)spaced 6-
inch o.c.at the 4-inch laps and 6-inch o.c.in three(3),equally spaced rows in the center of the sheet.
Underlayment: Lastobond TU HT,self-adhered
5.8.4 For use over insulation or coverboard and under mechanically attached prepared roof coverings,underlayment
attachment shall be in accordance with the manufacturer's installation instructions and attachment of the
insulation or coverboard shall be in accordance with the prepared roof covering manufacturer's Product
Approval.
5.9 Exposure Limitations:
-
�dn
{e�ds_ s, c.,a e-P". - .�^. .'•,.� = `�- _..Fr � �{6.C,,,
Underlayrnent ve i u_rn Prepare {loaf
p
9nstaltatign T.Ype fxpusr days}
Lastobond Eaves Protection Sheet,Lastobond 195,Lastobond ECo,RESISTO LB1236,Grip- Mechanically 30
Rite Eave&Valley Protector,TopShield ICE&WATER DEFENDER or RESISTO LB1244 attached
Lastobond TU HT Adhesive-set tile roof 30
system
Lastobond Shield,Lastobond Pro HT-N,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT, Mechanically 90
Lastobond Pro HT-S,EnviroShield,Lastobond Smooth Seal HT or Grip-Rite Smooth Seal HT attached
Lastobond TU HT or Colphene FR GR Mechanically 180
attached
5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct-deck tile roof assemblies,the
maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during
loading of the roof tiles.
r
y g � q E?� Z14 � �6�(1 3l� , "a. [1T I�FTt@E IlU5riiL IaAtS w3Wl
a ...y .. w
Underlaylnent ""T.i1e Profile.; Stagvlettpd ; Ntaiiutt� tgpe
Flat Max.10-tile stack 6:12
Lugged Max.10-tile stack 5:12
Max.10-tile stack(bottom 2-tile stack shall be inverted,
6:12
followed by 8 tiles high on slope,as shown below)
Lastobond TU HT 'I'
Lugged
in
NEMO ETC,LLC Evaluation Report S18010.06.09-R18
Certificate of Authorization#32455 7'H EDITION(2020)F8C NON-HVHZ EVALUATION FL2569-R20
Soprema Roof Underlayments Revision 38:09/17/2020
Page 7 of 8
MEMO I etc.
TASL 4� (!tE SLIPPAG1 ItdfT S.FpR C166 ff IISEAL TIop11S `
Undertyment Ylle,Profole;. Sta in Met#ad
g g
Colphene FR GR Flat Max,10-tile stack 5:12
Lugged Max.10-tile stack 6:12
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation instructions
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application,and prime the substrate(if applicable).
6.2.1 Installation of RESISTO LB1236, Grip-Rite Eave & Valley Protector or TopShield ICE & WATER DEFENDER self-
adhering underlayment in a reroof (tear-off) application atop an existing underlayment (per Table 2) requires
priming of the existing substrate with RESISTO EXTERIOR PRIMER. Final acceptance of any existing substrate in a
reroof(tear-off) installation is at the discretion of the installer and the Authority Having Jurisdiction. Should a
question arise as to the suitability of an existing substrate to receive RESISTO LB1236, Grip-Rite Eave &Valley
Protector or TopShield ICE&WATER DEFENDER self adhering underlayments contact RESISTO technical support
tastc3#car(�TU;E#Tjt asobori cf Shre#d,,1 asto args I�r�y #T#�I�RE51S 5AStlt0 # PlY
s # s$p olad#?reef l I S; pp eroSl ie# ,E tC�k i�i ete f'��3 Dow, 3�' $; Armq, "011, 1*
r Ct1o0i}15a9#I ,° ra lieu ## �a( # �RS#u LBx, 36 i airS�#� afoci Yj A
x WAfE#2(fEl11�SJ�# Sdfzilo[glris�F k
t✓ „.vk3 .. 1_"n rz '�a`vCr? 5 v .fl „S.k..,GRtt4.&".5? % -�, "..F. ': .✓ h N'b
6.3.1 Non-Tile Applications:
Shall be installed in compliance with requirements for an approved self-adhering underlayment(ASTM D1970)in
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering
to be installed,and the manufacturer's installation instructions.
When installed over a mechanically attached base sheet of FBC Approved ASTM D226,Type II felt the base sheet
shall be fastened in accordance with FBC 1507.1.1 or R905.1.1.
6.3.2 Tile Applications:
Limited to Lastobond TU HT or Colphene FIR GR.
Shall be installed in compliance with the requirements for Self-Adhered Membrane set forth in FRSA/TRI Florida
High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition and the manufacturer's installation
instructions.
Refer to Section 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for tile staging limitations.
Refer to7.8.2 for attachment limitations.
Refer to Table 4 for tile staging limitations.
0 p
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
Contact the named CIA entity for manufacturing facilities covered by F.A.C.Rule 61G20-3 CIA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
w
UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com
-END OF EVALUATION REPORT-
NEIVIO ETC,C,LLC Evaluation Report S18010.06.09-R18
Certificate of Authorization#32455 VH EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-R20
Soprema Roof Underlayments Revision 18:09/17/2020
Page 8 of 8