Loading...
HomeMy WebLinkAboutNotice of Acceptance , CONTRACTOR COPY RECEIVED MIAMI•DADE APR 0.9 2021 MIAMI-DADE COUNTY e mm f�*rmltti�,)g NpartmeXRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING,ENVIRONMENT,AND REGULATORVt. Lucie-Ounrt/ 11805 SW 26 Street,Room 208 AFFAIRS(PERA) BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy Florida Shutters,Inc. 1055 Commerce Avenue Vero Beach,FL 32960 �)16q —0.2 7' U�7 SCOPE: ®Ei C1 G tl C . This NOA is being issued under the applicable rules and regulations govemmg the use" of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product,Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: • "Impact"Aluminum Binged Colonial Shutter , APPROVAL DOCUMENT: Drawing No.20-28463,titled"Impact Aluminum Colonial Shutter",sheets 1 through 8 of 8,prepared by Engineering Express,last revision dated October 19,2020,signed and sealed by Frank L.Bennardo,P.E.,on October 19,2020,bearing the Miami-Dade County Product Control Revision stamp with the Notice of Acceptance number and the expiration date by the Miami-Dade County Product Control Section. MISSILE IMPACT]RATING: Large and Small Missile Impact Resistant LABELING:Each unit shall bear a permanent label with the manufacturer's name or logo,city,state,the following statement: "Miami-Dade County Product Control Approved",and NOA number,per TAS-201,TAS- 202,and TAS-203,unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA#19-1218.01 and consists of this page 1,evidence submitted pages E-1,E-2,E-3,E-4& E-5 as well as a proval document mentioned.above. The submitted documentation was reviewed by Relmy A.Makar,P.E.,M.S: — - -- — --— -- - - ---------- NOANo:20=II02.0-G------- —-— ------ - --�•-- ------------------ Expiration Date: 03 l o L�l Z f Approval Date: Page 1 Irr Florida Shatters,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#00-0411.09 A. DRAWINGS 1. Drawing No. IOOOA, titled "Impact Colonial Shutter ",prepared by W W. Schaefer Engineering& Consulting, P.A., dated January 10, 2001, sheets I through 7 of 7, signed and sealed by Warren W. Schaefer, P.E. B. TESTS 1. Test Report on: 1)Large Missile Impact Test,per PA-201 2) Cyclic Wind Pressure Test,per PA-203 and 3) Uniform Static Air Pressure test per PA-202, of colonial shutters, prepared by Hurricane Test Laboratory Inc., Report No. 0205-1201-99, dated March 23, 2000, signed and sealed by Vinu J.Abraham, P.E. C. CALCULATIONS 1. Anchor analysis and calculations dated 12124199, Pages I to 15,prepared by W. W. Schaefer Engineering& Consulting, P.A., signed and sealed by Warren W. Schaefer, P.E. D. MATERIAL CERTIFICATION 1. Certified Tensile Test Report No. DAM-142,prepared by QC Metallurgical Inc., dated 0310212000,per ASTME8-93, signed and sealed by Frank Grate, P.E. 2. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#04-0130.02 A. DRAWINGS 1. Drawing No. IOOOA, titled "Impact Colonial Shutters", sheets 1 through 7 of 7, prepared by W W. Schaefer Engineering& Consulting, P.A., dated January 10, 2001, signed and sealed by Warren W. Schaefer, P.E. on March 18,.2004. B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. By Miami-Dade County Building Code Compliance Office. E. MATERIAL CERTIFICATIONS 1. None. He1my_AsMakar:XXi M.S_: . - Product Control Section Supervisor -NOA No.-20=Y102:0- �------- ------ Expiration Date: Approval Date: E-1 1 i Florida Shutters,Inc. NOTICE DF ACCEPTANCE: EVIDENCE SUBMITTED 3. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#09-0121.12 A. DRAWINGS 1. Drawing No. 08-FSH-0001, titled "Impact Aluminum Colonial Shutter '. sheets 1 through 7 of 7,prepared by Engineering Express, dated November 21, 2008, signed and sealed by Frank L. Bennardo, P.E., on March 10, 2009. B. TESTS 1. None . C. CALCULATIONS 1. Anchor analysis and calculations dated 0212012009, Pages 1 through 21 of 21, prepared by Engineering Express, signed and sealed by Frank L. Bennardo, P.E., on 0212012009. D. QUALITY ASSURANCE 1. By Miami-Dade County Building Code Compliance Office. E. MATERIAL CERTIFICATIONS 1. None. 4. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL# 10-0209.14 A. DRAWINGS 1. None. B. TESTS 1. Test Report on: 1)Large Missile Impact Test,per PA-201 2) Cyclic Wind Pressure Test,per PA-203 and 3) Uniform Static Air Pressure test per PA-202, of colonial shutters, prepared by Hurricane Test Laboratory Inc., Report No. 0218-0203-09, dated July 01, 2009, signed and sealed by Vinu J. Abraham, P.E. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. By Miami-Dade County Building Code Compliance Office. E. MATERIAL CERTIFICATIONS 1. None. _ Helmy A.Makar,P.E.,M.S. Product Control Section Supervisor - - -— -- -- ---------- ----- - - --- ------- --..- - - - ..-NOA No.20=1102:06------- - -- Expiration Date: Approval Date: E-2 Florida Shutters,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 5. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL# 11-1128.06 A. - DRAWINGS 1. Drawing No. 08-FSH-0001, titled "Impact Aluminum Colonial Shutter ". sheets 1 through 8 of 8,prepared by Engineering Express, dated October 10, 2011, signed and sealed by Frank L. Bennardo, P.E., on October 11, 2011. B. TESTS 1. 1. Test Report on: ])Large Missile Impact Test,per PA-201 2) Cyclic Wind Pressure Test,per PA-203 and 3) Uniform Static Air Pressure test per PA-202, of colonial shutters, prepared by Hurricane Test Laboratory Inc., Report No. 02.18-0203-09, dated July 01, 2009, signed and sealed by Vinu J. Abraham, P.E. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. By Miami-Dade County Department of Permitting, Environment, and Regulatory Affairs (PERA). E. MATERIAL CERTIFICATIONS 1. None. 6. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL# 14-1120.10 A. DRAWINGS 1. None. B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. By Miami-Dade County Department of Regulatory and Economic Resources. E. MATERIAL CERTIFICATIONS 1. None. _Helmy A.,Makar,,.P.E.,,M.S., Product Control Section Supervisor ------.----------- --NOA-No-20=1102:0 ---- ------ - - Expiration Date: Approval Date: E-3 Florida Shutters,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 7. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#15-0316.10 A. DRAWINGS 1. Drawing No. 14-1960, titled "Impact Aluminum Colonial Shutter ", sheets 1 through 8 of 8,prepared by Engineering Express, last revision dated October 28, 2014, signed and sealed by Frank L. Bennardo, P.E., on October 28, 2014. B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. By Miami-Dade County Department of Regulatory and Economic Resources. E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS 1. Florida Building Code, 2014 Edition, compliance letter, dated.03106/2015, issued by Engineering Express, signed and sealed by Frank L. Bennardo, P.E. 8. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#18-0110.01 A. DRAWINGS 1. Drawing No. 14-1960, titled "Impact Aluminum Colonial Shutter '; sheets 1 through 8 of 8,prepared by Engineering Express, last revision dated Dec. 28, 2017, signed and sealed by Frank L. Bennardo, P.E., on December 29, 2017. B. TESTS 1. None. C. CALCULATIONS 1. Anchor analysis and calculations dated 01103118, Pages 1 through 19 of 19,prepared by Engineering Express, signed and sealed by Frank L. Bennardo, P.E. D. QUALITY ASSURANCE 1. By Miami-Dade County Department of Regulatory and Economic Resources. E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS 1. FBC, 2017 Edition, compliance letter, dated 12129117, issued by Engineering Express, signed and sealed by Frank L:Bennardo, P.E. Helmv A.Makar,P.E.,ns. Product Control Section Supervisor - - - -- ----- -- ----- -- --- -—- ---- ---- ---------— —- - --- - --N0:4 No:204102:06- ---- --- -- Expiration Date: Approval Date: E-4 Florida Shutters,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 9. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL# 19-1218.01 A. DRAWINGS 1. None. B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. By Miami-Dade County Department of Regulatory and Economic Resources. E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS 1. FBC, 2017 Edition, compliance letter, dated 12106119, issued by Engineering Express, signed and sealed by FrankL. Bennardo, P.E. 10. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. 20-28463, titled "Impact Aluminum Colonial Shutter", sheets I through 8 of 8,prepared by Engineering Express, last revision dated October 19, 2020, signed and sealed by FrankL. Bennardo, P.E., on October 19, 2020. B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY-ASSURANCE 1. By Miami-Dade County Department of Regulatory and Economic Resources. E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS 1. FBC, 2020 Edition, compliance letter, dated 10119120, issued by Engineering Express, signed and sealed by FrankL. Bennardo, P.E., on 10120120. Helmy A.Makar,P.E. M.S. Product Control Section Supervisor ---- ---- ----- -- --- - -- ----- -- - - --- --- ---- --- -- -----N0A-No.-20=1102:06------ -- ---- -- Expiration Date: Approval Date: E-5 I - i ' i LLLll lull/// - IMPACT ALUMINUM COLONIAL SHUTTER6549,.70F'af,,� FOR USE WITHIN AND OUTSIDE THE HIGH VELOCITY HURRICANE ZONE (HVHZ) - i�IIy!yt9�22* 112'MAX. 56'MAX. SHUTTER WIDTH SHUTTER WIDTH •� •, E I 28'MAX. 28'MAX. a• •C 28'MAX. 28'MAX. 28'MAX. 28'MAX. PANEL WIDTH PANEL WIDTH 1TI PANELWIDTHT1I PANEL WIDTH PANELWIDTHt PANEL WIDTH ���R�Cs •.n�Rl U. 1 I I 1 —t- 11 I 3 �// `�0{jCLLytD'J.I•�� vmi Ltj J, •18 I IB � Z Q- 0 T/0 1�5 ��W 2 7 8 1 zQw =m q Egl 7 �8 10 19 g 0 a zx 02 ca 2•TYP. 1 n 19 2'7YP. WW oN��Ww u 1w- E Sm- g t -- 3 In w S ow m ^ i d CI O < -L J Z i a l i J w i w a SIMILAR E LI Z loll JQ V w N O n 1 6J 3 w p =� UW 1 � LTN E fI Es =iug OO ` r3 (OP'nONAL) OV� Q >(OPTIONAL 3 =/1/8'MAX.GAP BETWEEN ANY PANEL(TYP.) 0 i UAD PANEL SHUTTER u- FA N.T.S. EXTERIOR Z DOUBLE PANEL SHUTTER g GENERAL NOTES 1 1 N.T.S. EXTERIOR ELEV 1. THE SYSTEM DESCRIBED HEREIN HAS BEEN DESIGNED AND TESTED IN ACCORDANCE WITH THE FLORIDA BUILDING SYSTEM NOTES to a CODE SEVENTH EDITION(2020),FOR USE WITHIN AND OUTSIDE THE HIGH VELOCITY HURRICANE ZONE,PER TAS 201/202 1. SINGLE&TRIPLE PANEL SHUTTERS ARE ALSO APPROVED CONFIGURATIONS. SINGLE PANEL SHUTTERS SHALL y /22. NO 33-1/3%INCREASE IN ALLOWABLE STRESS HAS BEEN USED IN THE DESIGN OF THIS SYSTEM.WIND LOAD COMPLY WITH THE DOUBLE PANEL SHUTTER REQUIREMENTS&THE TRIPLE PANEL SHUTTERS SHALL COMPLY WITH THE m b D DURATION FACTOR Cd=1.6 HAS BEEN USED FOR WOOD ANCHOR DESIGN. K b ? 3. POSITIVE!AND NEGATIVE DESIGN PRESSURES CALCULATED FOR USE WITH THIS SYSTEM SHALL BE DETERMINED BY QUAD PANEL SHUTTER REQUIREMENTS. OTHERS ON A JOB-SPECIFIC BASIS IN ACCORDANCE WITH THE GOVERNING CODE. 2. THE NUMBER OF STORM BARS REQUIRED FOR USE WITH THIS SYSTEM VARIES,DEPENDING ON REQUIRED SIZES HIM 4. THE SYSTEM DETAILED HEREIN IS GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SPECIFIC SITE. FOR SITE AND DESIGN PRESSURES.SEE ELEVATIONS AND DESIGN SCHEDULES HEREIN FOR MINIMUM STORM BAR o s)S!z m u CONDITIONS DIFFERENT FROM THE CONDITIONS DETAILED HEREIN,A LICENSED ENGINEER OR REGISTERED ARCHITECT REQUIREMENTS AND LIMITATIONS. E SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE IN CONJUNCTION WITH THIS DOCUMENT. n� •�1 $ LOADS PE�MIT HOLDER SHALL VERIFY THE ADEQUACY OF THE EXISTING STRUCTURE TO WITHSTAND SUPERIMPOSED 6. ALL EXTRUSIONS SHALL BE 6063-TS ALUMINUM ALLOY,UNLESS NOTED OTHERWISE. MAXIMUM ALLOWABLE -80,0 PSF '6 il 7. SHUTTERkMIDTH SHALL BE RESTRICTED BY THE MAXIMUM DIMENSIONS SHOWN HEREIN.MAX SHUTTER HEIGHT MAY EXCEED 96'(UP(TO 144"MAX)PROVIDED THATTHE MINIMUM STORM BAR SPACING INDICTATED HEREIN IS NOT EXCEEDED DESIGN PRESSURES: +80 a� .0 PSF AND THE OPTIONAL'TONGUE AND GROOVE BLADE'IS NOT UTILIZED(PART*32). a `a iz S. EACH SHUTTER ASSEMBLY SHALL BE PERMANENTLY LABELED ON THE BOTTOM,PLACED ON THE BACK OF THE REFERENCE DESIGN SCHEDULES HEREIN FOR ADDITIONAL EGPrRKrOFTmEEDuwEnnEa SHUTTER WITH A MINIMUM OF THE FOLLOWING INFORMATION: i FLORIDA SHUTTERS,INC. LIMITATIONS TO ALLOWABLE DESIGN PRESSURES,AS DETERMINED 20-28463 ' VER0'8EACH,FLORIDA BY SHUTTER SPAN,STORM BAR CONFIGURATIONS,AND ANCHORAGE. TASSGLH 3 i MIAMI-DADE NOA NUMBER PAGEDESCRPON: 9. ALL BOLTS&WASHERS SHALL BE ZINC COATED STEEL,GALVANIZED STEEL,OR STAINLESS STEEL WITH A MINIMUM VISIT ECALC.10128463 TENSILE YIELD STRENGTH OF 60 KSI.ALL 3/16.0 OR 1/4.0 POP RIVETS SHALL BE 5052 ALUMINUM ALLOY OR STRONGER. w w 10.ALL STEEL IN CONTACT WITH ALUMINUM SHALL BE PAINTED OR PLATED AS PRESCRIBED IN THE ABOVE-NOTED FOR SITE SPECIRO DEVIATIONS BUILDING CODE, 6NORENFORVATIONABOt"I"S DOCUNENT 11.THIS ENGINEERING IS FOR THE EXCLUSIVE USE OF ITS OWNER,FLORIDA SHUTTERS,INC.IF THIS HAS BEEN ORSCANTIDSORCODE J7 r SUBMITTED BY ANOTHER COMPANY IT MUST HAVE A NOTARIZED LETTER OF AUTHORIZATION. TRSITENGINEERWGEXPRESS.COWSTORE LLJII P FORAOm1101ULPL %RVOM RESOURCES i ffi I i I ' I F• ..65 9 LA/980 MINIMUM ANCHOR a -4 SPACING PER ANCHOR j�°A65 a i = SCHEDULE _* lO/ 9,nn I- -.-._.; 1/2' 1 3/8'MIN. �•'•. sTA p E 4 x:,:•I, IN. 5 }, 16 SSIO;AlP+n"a if` ffai t3( H ANCHORS PER T > aw i ANCHOR SCHEDULE EDGE I 1 I I W I conLL^ 20 DISTANCE N I I 23 Z(T 0U 3 i&6K aw 2 I I 3/8'MIN. z<l o<hm—a ig 3 I I nP. W ti WI O 3- u Lu HINGE ANCHORS N K a g w II F PER ANCHOR I e I j 1 SCHEDULE I II O v w 3 •WALL CLIPS N I I I ~ p a LOCATED BETWEEN 5 B '" o HINGES,SPACED I II z AT 30'O.C.MAX. B 1 21 3 71 a 9 10 2 U 1 (2)t8 SMS PER CLIP z g 2 WALL CLIP DETAIL o a OPEN SHUTTER POSITION I"TO 1-1/a• m a L C a 6'=1'-0' HORIZ.SECTION Lu O 1, la Z �2�SIDE HINGE DETAIL 0 0 EXTERIOR ELEV. S u e to - i �-_ d__-r___ _ - 3'MINIMUM =0 z z o a SEPARATION FROM w 0 0'R f w 19 S EXISTING GLAZING G Q h ae" <o o> o 3 EDGE 2 6 28 1 L DISTANCE a--a Q Z n i ANCHORS MAX, 2 f ePER ANCHOfa R �� 0 i SCHEDULE I LPL LF, 8 1 1 .• w� _ _ 1 � EXISTING GLAZING w. I II II ii I k'�a s a 2'x2'xl/B'OR 2'x3'xl/8' I II II I o a S ALUMINUM ANGLE,3' I III I 6 Egg V rt ' LONG.ANGLES LOCATED 27 I I III d�. I 2 BETWEEN HINGES,SPACED 1 AT 30'O.C.MAX. 2 i i i i I 2 n;t:�&$u i 20 2 1/4'-20 STAINLESS I I 4 STEEL BOLT W/ a /... RIVNUT. � ••• � ALT. WALL CLIP DETAIL �- �'" OPEN SHUTTER POSITION 6 2 III xPI'IMEHGERMEVIRM 24 �'�` 212 6'-110' HORIZ.SECTION .: 1 20-28463 11 1E—? PAGE OESCRIPTI°Nt (NOTE:WALL HINGE NOT SHOWN FOR CLARITY.) NOTE:ONLY ONE STORM BAR SHOWN FOR CLARITY ALT. VERTICAL SECTION a FRAME CORNER DETAIL 1 .TYPICAL VERTICAL SECTION lA WITH HOLLOW BLADE �1 6'=1'-0' ORTHOGRAPHIC i 2 16'=10=0' VERT.SECTION Z 6'=1'-0' VERT.SECTION Z E \/ I I I I I i NpeN ' WOOD ANCHORS<PER ' TcalANCHOR SCHEDUEXISTING EXTERIOR CENTERED IN NO4 EDGESPACING yyy WALL FINISH BY OTHERS EDGE 2X MIN.WOODT i I n. DISTANCE I ��NG EXTERI00. 28-MAX.PANEL WIDTH,TYP. DISTANCE EMBED. ��� WALL FINISH BY OTHERS E)OSTING 3'MINIMUM .Q e r-'4 GLAZING SEPARATION FROM 1/8'MAX.A EXISTING GLAZING. 1 1 z 1 z 3 2 1 '.��' s%'•••�'I..� � �. UJr�d y' c (17 . .. 3 0 NCL N !ANCHORS o g s ANCHORS z L � V¢ ?w PER AN OR Q PER ANCHOR I� eQ W Yg}�_ SCHEDULE 7_ (I¢ry 0 I i3 W g 1 2 18 IB 2 18 18 2 16 9 B 'I1IUIlw��I/('L�� uu�w w„ 23 1 1 o 3/4-MIN. w m 23 TYPICAL :O ILI p d 9 SHUTTER WIDTH 5 "' TYPICAL HORIZONTAL SECTION y I 3 4-=1'-0' HORIZ.SECTION I EDGE EDGE EXISTING EXTERIOR U {wCu DISTANCE 2 3 DINCE 3' WALL FINISH BY OTHERS 3/4'MAX. 7 8 10 i-4 S u ' z 2g ANCHORS PER = STORM; • STORM BANCHORSCHEDULE 20 N w�zrnu 4- 4- I 7 6 10 3 4' WQLL N 9 ry u�` 0O 0.- ZoSHUTTER O m z I • SHUTTER2 3 EMBED. 19 2 u ?o a o SHUTTER BEYONDFORT SLOTTED HOLE FORTHRUBOLTS 3/fil 0 HOLES NOTE:CONNECTION OF STORM BAR TO SHUTTER 0 f 8 ANCHOR�SPACING 2. FRAMES IS NOT R J e PER ANCHOR SCHEDULE 4. ITYPIMCAL EQUIRED AT SINGLE BAR SHUTTERS. i STORM BAR STORM BAR STORM BAR STORM BAR TO FRAME �1 CONNECTION TYPE 'A' s CONNECTION TYPE 'B' 4 CONNECTION SECTION 0 CONNECTION DETAIL 1 3 2--lI-0- EXTERIOR ELEV 3 2-=1'-0' EXTERIOR ELEV 3 2'-1'-0' VERT SECTION 3 6'=1'-0' VERT SECTIONEDGE • � i ocaSSa��� e eDISTANCE 0 3S/16.0 SLOTTED OR �nBR /8. ROUND HOLES g I x t I.'s 9 STORM BAR I ANCHORS 7 8 10 ANCHORS cyo$ PER ANCHOR PER ANCHOR SCHEDULE SCHEDULE PER ANCHOR 3 EMBED. EMBED. i3 SHUTTER • 3 R R YY coprF NT EGPEDINa ESPF55 3/4 38 EXISTING EXTERIOR EXISTING EXTERIOR 20-28463 ANCHOR SPACING WALL FINISH BY OTHERS WALL FINISH BY OTHERS SCALE: - PERANCHOR SPACING SCHEDULE SHUTTER BEYOND SHUTTER BEYOND PAGE DESCRIPTION: STORM BAR STORM BAR ALT. STORM BAR 6 CONNECTION TYPE 'C' CONNECTION SECTION s CONNECTION SECTION s i C i 3 2-.11-0' EXTERIOR ELEV 3 2'=1'-0- VERT SECT70N 3 2' 1'-0' VERT SECTION I I I - _ I 1 I I - `j5511111111�� FRPW65a9 9_0 O ' haw i g 3 �' ?�IoLmw 6 ! =O Wui �IrcryOSuw O J Ww aC � i m0 u31•i a�'u $G In tY`u�m 1 ow �Q d L9 t Z g � � I 3 � ` U I z rr N ww �a Lu � J W S m N O a LL W LL n O O a ! ALT. VERTICAL SECTION =f Zo a i WITH TONGUE AND GROOVE BLADE U) o w VERT.SECTION `y O Ef i3 I WOOD ANCHORS PER E ANCHOR SCHEDULE EXISTING EXTERIOR G SPACING EDGE - CENTERED IN NOMIMAL YY DISTANCE WALL FINISH BY OTHERS EDGE 2X MIN.WOOD EXISTING EXTERIOR DISTANCE WALL FINISH BY OTHERS Q EMBED. o c S a a R EXISTING 3'MINIMUM �a$?a gj .-1_ GLAZING SEPARATION FROM ** 6w S y Aw, EXISTING GLAZING Xud h go c m Bqq _RI � � ANHORS ANCH ORS ig PER ANHOR . SCHEDULE -- SCHEDULE ANCHOR =��Y N 6pR ' PER � 2 lNOTE MAX SHUTrER HEIGHT WITH 3 2 5 6 �LkRR I AND GROOVE BE OPTION SHOWN HEREIN 1 copfFJGFRDICPEEAPRo F.+�RE55 Z3 SHALL NOT EXCEED 96'OVERALL. 20-28463 I 3 TYP3CAL - S -SHUTTER WIDTH pAGE OESCGIETION: ALT. HORIZONTAL SECTION 2 WITH TONGUE AND GROOVE BLADES I �� c I 4 4'=1'-0' HORIZ.SECTION 5 i i i i I 1 -- 1t11u t i 4.330•MAX. \\ V•�I••• IV',q.Q'�i .I 1,370•HAX, 0,930• 3,820'MAX, \ �'t 7!/N(�•F '.0 0.535• 7.675•MAX (2.750•MIN.) Z9/cam-�,v�� •}C k� �1•s'� 2,111 2.000• I (2.750'MIN.) LENGiN 2 0.120• =u.• NO. , W='.l 0250 O,OSi• 0.145• n A 1.625• �y .Z• oN OF Z� --3.126•-� �I .375• 4'.... 00-39 11, q ~ 'T x0, •�� N'. 0.062• wcn 0.0 50'• r1 G0.390` •FRAME CAP Z-BLADE HOLLOW BLADE 0.630• Illw 'fTK , LRAME 606376ALUH. O 606776ALUM. 4 6063T6ALUH. WALL HINGE 1 WALL_ HINGE 2 1 606376A1UH. JrA 60OV-1SALUM: Jr6 600VISALUM. Z.1�,' ay`O �`ali wW IN�..AWu U"1 w jl6Z it � f-aaoD••----f-•�- �---3.GDG•--� t----s.aoo•---•f-�-T{• pyj�/(,4Jjp 2,820• 1 I 7 ILfo3rT o w R �0,190• 0.690• ,o LENGTH v AS REQ'D o LENGTH v AS RWD o o 0.125• ti O • 1 �I0.125• I LENGTH 1- o _o o �j LENLENGTHv B• '� t 2.00(1•-�T0.093• 0.125 � 0.125' 0.125' gI�� 2s00• FRAME LENGTH v AS REV •--Il }1.DDD• Z j FLAT WALL HINGE CORNER KEY O STORM BAR'A` 8 10 STORM BARB' STORM BAR'C' 11 HURRICANE CLIP w �A 5C 6005-,S ALUM. 6 6063TS AWN, 6061 T60R 6005.75 ALUH, 606176 OR6O05-TS ALUM. 60614GOR6005•TSALUM. 6063 TS ALUM. ewe �u 1 I HO.375•DIA. I�--I{ 750• 1' • +£ + '.II A 1o.zsD .L_ -1-.is � 4.050o ='aat Ywaj 3.000 4.00' 300• .25' 0.H12 ALU En LENGTH v 2'?12A LENGTH.2.6 13A P.C I11a 4•9120 4'013B 0.as0• e L • -ea0• � N LENGTH 6 t STORM BA 1,BOB• TONGUE AND 6063•73ALUMINUMT:oo o" OJ i STORM BAR T RM R IL GD 1 CONNECTION ANGLE ( CONNECTION ANGLE @ HINGE PIN PANEL HINGE 32 GROOVE BLADE WALL CLIP L J. 6063-13AWN. 13 38 6063TSAWM. �'6 6063-TSALUH. �•� 6063-TSALUM. 60634SALUN. 33 NYLON OR6063TSALUM. 1 y W§ q $ II BRLOPMATERIAL9 c g j H0. DESCRIPTION INOTES I NO.laESCRIPMOH IROTES T1 tl .i 1 SHUTTERFRAAE 60R.76ALUMINU14 1 17 IsHurmAPAHELNINCE 0063rt6ALVMIHUM.c LONG ptAHOHINGE d441=2a � �I 2 FRAMECAP 0003-TCALUMINUM I 11 lusWTHICKALUUINUM HURRICANE SHEET 13003.%14nUMINUIA.CUTTDFPMAUESME -_ x z=tiR yEqrgt ' I - 3 Z-BIADE 6063.TGALUUINUM 11ll1N 19 11VIVIRUBOLTORTHREADED Rao PGNU7 HOTREO9ATSINOLEBARSHUTTERS 4 HOLLOWBLAOE 6043.TOALUMINULI I SD Iv4rmoLLY=KNvrORGC5V6RWNUT FORHURRICANECUPBDLTSKSTOiU1BARTHRUBOLIS _ i FA WALL141--"PET - 6a05.75ALUWNUI4.USEOHiiH SUiGIEPAHEL9 21 IWIVSMALUDINUAl POP RIMS POSRIONSATFRAIMECORNERSL6•LWCO.C. Q' SB WALLHINOETYPE2 600ST6ILLUMINUM,USEO HIIHDOUBLE MINGEDPANELS 22 IG.M.SSSMSSCREWS 9PERPWI0NINCE PERT .ODUI:tRL•V1SED (( tai aC FIATWALLNRiOE 600s.T6KUWNUM,FA51Et SHVTiERFRAME 23 06s516•SSSMSSCREWS 4 PER WALLLHINCEUITO SHUTTER FRAME COnplyinguiLll the F10rid3 �(R#d •` $ e 21a'AAOV FRIWE CORNER KEY 6N4 T5ALUAONOM.=IIATEACHFMNECORNFR 74 iNYI• ELBOITORVNNO BOLT 4 PER IKIRRICANE CLIP INTO SHUTTER RNNUTS WId179�C S� j W;N 7 1�T41M•SWRIABAR F061•To OR4045.TSADLUNUU SSA IOEMSSP.H.SMS SECURES T.OUOEEND TO FRAM6 CAP PER BLADE ENO ^I ® e 210XU1•STORM BAR 6061•T60R6005•TSAIUMINUM 250 16•V6•SSP3LSUS HOLLOWDLADE ENOTO FRAAE CAP PER BLADE ENO 110110n DOt 2 L O R z j •�[V' D ° 9 NOTUSED 2CA RUN. U 0v mrtvlxETmveocAla 10 216711IMSTORMBAR 6061•Te OR LOOS.TSA.UMINUM 260 HOTUSEO A 1 C ucG 001f it I j 4SU I Ly,I �-V 11. Sh1T1fA•NURRUCANECUP.O•LOKO 6063.T6ALUMINUM,L..1HUTTERSCLOSEO 27 e6da/4•S9FJLSUS 2PERFRAMECORHERWO CORNER KEY 14-1960 , 17A 2lOY/N•STOAUBARENO CONNECTOR 6063.TSAlUMIHUM,TIONG 26 06%WSSRH.SU9 t PER FRAMECORNERIHTO FRAMESCREHIBOSS o�iEo `t^, YYY 1.. 123 Z7 WR-STORIAMAR ENOCONNECTOR co63.TfiA4AJwxuM,A•IOIID 29 114T0'MINBOLTYlfWING NUT 1PERSTORMBAREHDTHROUGHENOAGIESdBAR L•W2t $ �L 13A 2kPa1H•STOA48MENDCOHNECTOR 4063•TSALUWNUM,2'IONG 1. NOTUSED �yU rA�� 138 tri's1I4•STORH BAR END CONNECTOR 4003.TSALUMINUM.4•LONG 20B NOTUSED v$ p I AL 11 NOTUSEO 21 66K'J6•SSFIATHEADSMS TONGUE AND GROOVE END TO FRIWECIIP 4PER BLADE END tS HOTUSED 32 TONGUEANOORMBLADE 606i-15RU�V S n alw�lw '4�1: 16 SI�G0.XPlOflGNIIIG@PIN GD63.15AUlUllula 31 90MIGALU111RUMOR]mORWALLCUP ONEBETYYEENF�ICHWAII.HINCE 1'QC I ' n i I _ , ``111111117f!!!`! • PEOR(BEN D CENTERLINE CENTERLINE CENTERLINE CENTERLINE CENTERLINE• CENTERLINE '•? OF OF OF OF OF OF Q'• C SUPPORT SUPPORT SUPPORT SUPPORT SUPPORT SUPPORT 4 BAR SPAN BAR SPAN BAR SPAN =* _k _ A ' 0` z W %11 . UI STATo i \° x llUj1 � �3 x WlL oo� 611S= SHUTTER WIDTH L T�- Nw U �'W C7C <y u z \ Gm xtl z . �w \ W W MEL oti° �s Gmi u3�P�y� �gOLU Uj ZS ID SHUTTER WIDTH C SHUTTER WIDTH v U W �Cu R i--i S u -SINGLE BARS E U !!TL.-L. =.--.I •Se I vxi= 'a �t� E �Z R d LL)> O =6 O ~,xf1 x N IL Q LL N O + I�U O O d TWO BARS THREE BARS "_- x CENTERLINE CENTERLINE - =g 0 `O o OF OF (n O m S Z s SUPPORT SUPPORT u¢,^� J o BAR SPAN Qo> Qo TABLE 1: SINGLE STORM BAR ANCHOR SCHEDULE: ANCHOR NOTES: 9 SHUTTER DESIGN SCHEDULE WALL CLIP ANCHORS: 1. ANCHORS SHALL BE INSTALLED IN p � (2)1/4•CARBON STEEL TAPCONS(RW) Gi f THRU WOOD BUCKS OR DIRECTLY]NTO ACCORDANCE WITH MANUFACTURERS' ._I Ix MASONRY/CONCRETE WITH 1-1/4'MIN RECOMMENDATIONS. LL SHUTTER ALLOWABLE DESIGN EMBED,1-1/2'MIN SPACING,AND 1'MIN 2. TAPCONS SHALL BE MANUFACTURED PRESSURE(PSt) BY ITW. 'DEWALT PANELMATE'ANCHORS HEIGHT EDGE DISTANCE. FOR USE IN CONCRETE,HOLLOW BLOCK OR POSITIVE NEGATIVE • (1)I12 WOOD SCREWS TO G=0.55 MIN WOOD MAY BE MALE OR FEMALE. aa _ f UPT064' SOD psi eD.opsl WOOD WITH 1-1/2'MIN THREAD 3. WHERE ANCHORS FASTEN TO °' a a`:a y u: PENETRATION AND 3/4'MIN EDGE alx n 55' 76.1 psi 76.1 psi DISTANCE, NARROW FACE OF STUD FRAMING,ANCHOR c e a� a�� C 55• 71.0 psi71.0 ps SHALL BE LOCATED IN CENTER OF NOMINAL b:(MIN)WOOD STUD(i.e.3/4'EDGE @ ww b 60- eea psl 6aa psi HINGE ANCHORS: DISTANCE IS ACCEPTABLE FOR ANCHORS TO u d�K c i b Yq 51 583 psi 56.0 psi si WO CARBONSTEELRECTLY I TO THRU WOOD FRAMING). a 8r3 µ�w WOOD BUCKS OR DIRECTLY INTO � tl S SHUTTER WIDTH 66, 54 8 Dsi 46a Dsi DENSTTYERN PINE'G--�OR55 OR GREATERBE o Jsi MASONRY/CONCRETE WITH 1-1/4'M1N �i IO EMBED,2-MIN SPACING,AND 2-1/2'MIN x 51.6 psl 442 psl EDGE DISTANCE. 6 u:67 ;p 'v� �� S. MINIMUM EMBEDMENT SHALL BE AS $48 NOTED IN ANCHOR SCHEDULE. MINIMUM i 6 S Qx m �x 7p• 47.5 Psi 40.5 psi • WOOD WITH I#12 WOOD CREWSMIN THREAD TO G-0.55 MIN g 7y 114 psi 311 psf PENETRATION,1-1/2'MIN SPACING,AND EMBEDMENT AND EDGE DISTANCE EXCLUDES QQ 3 74• 3B.0 psl 34a pN 3/4•MIN EDGE DISTANCE. FINISHES.NSTUCCO, BRICK,AND OTHER WALL ter, B„$� 3 ¢µ� NOTE: STORM BAR ANCHORS: 6. WHERE EXISTING STRUCTURE IS =p p11 €3 'xY C 1. MINIMUM SEPARATION FROM GLASS FOR ALL 1/4'-20 DEWALT CALK-IN ANCHORS TO WOOD FRAMING,EXISTING CONDITIONS e R R R 14 77 t0 f SHUTTER CONFIGURATIONS SHALL BE 3'MIN. MASONRY/CONCRETE WITH 7/B-MIN MAY VARY. FIELD VERIFYTHAT FASTENERS DOPTROff DIG9flI=EnM 2: MAXIMUM BAR SPAN AS DENOTED HEREIN SHALL NOT EMBED,2-1/2•MIN SPACING,AND 3'MIN ARE INTO ADEQUATE WOOD FRAMING sIx m BE MORE THAN 10'LONGER THAN SHUTTER WIDTH. EDGE DISTANCE. MEMBERS,NOTINTO PLYWOOD. 20-28463 3. TABLE 1 SHALL ONLY BE USED FOR SINGLE STORM • 1/4'DEWALT PANELMATES(MALE OR 7• WOOD BUCKS(BY OTHERS)SHALL BE SC u FEMALE TO MASONRY/CONCRETE WITH- TO THE EXISTING STRUCTURE.TRANSFERANCHORED PROPERLY TO LOADS -�--'— BAR SHUTTERS WITH 74'MAX HEIGHT.SINGLE ) PAGE DESCRIPTI10M sF STORM BAR SHUTTERS MAY HAVE 1,2,3,OR 4 1-1/4'MIN EMBED,2-1/2'MIN SPACING, m S. MACHINE SCREWS SHALT HAVE t7 1. w AND 3'MIN EDGE DISTANCE. PANELS' • 1/4'DEWALT PANELMATES(MALE OR MINIMUM OF OR ENGAGEMENT OF THREADS or x 4. REFERENCE STORM BAR DESIGN SCHEDULES FOR FEMALE)TO G=0.55 MIN WOOD WITH IN BASE ANCHOR AND MAY HAVE EITHER A GVERNEDADDITIONAL STORM LIMITATIONS TO DESIGN PRESSURES AS PAN HEAD,TRUSS HEAD,OR WAFER HEAD — GOVERNED BY STORM BARS AND STORM BAR MIN S MIN THREAD PENETRATION,1-1/2° (•SIDEWALK BOLT)U.N.O. FOUR BARS CONNECTIONS. MIN SPACING,AND 3/4'MIN EDGE S I i i i i ��o�oim�l Io�orou� II �� Ea9� J � 1m1Y2020-2.03M C.W C:WrenkeglEndwfftV E.anLOmdu n-Do aN mit+Uxi38/03-NDNOAW0.1218.0+Cdd da MV020FBC12038�-NOAI0.1218.01-DWG.eW W Nr"-1 m J n -Dl o9aorRDrn F�nymW /Tv1 W N..Fnz A r =C2y 0 M Y�rrOpmT (n^ �DIn C C C C C C C C C C C C C C C C C C C C C C C C C C C C N-m1 m w ,SS r 9vvvv 9 9 9 9�9 9 9 9 9 9 0 rn " N=Ocf 2002000 �yy-1-.-.-.-1�-a-.ti ti-�y-1 a pm o000000000000000000000000000 �@�S (n G ate m^I ^t�NNmNm^imm""2�H�H�NH1H W5 O o GZTZA 2 Ogaz�� 3 3 ZW co TA N ��V �N�YJ SSS g'SS SS'S er r D S Y % m A r o 3 m f 1 m En ss ���w����s�s�s$sssssss�s�s oa G) m ac d = z = Z ' U1 {o oy Fn o = n riper 8S8EBB S m C1 �77 03 1 Q rn C c A 7o r N s�sss�s�sper SEEs�s�s�os�sss rn o z r ��om�No�s��sssssssss�so �� a o � m 0 81+181+18181 $ o n o z z z v $�88,°Bk.'&'$S'$8,'$o4 L"Sr°3Sc'IB s +f Am REMARKS DRWN CNIm GATE m FR6SVE XL a +,21A18 , FLORIDA SHUTTERS, INC. ENGINE m M N MOM XL RB 1NIO'11 muFBCWSRMl RWN TSB 1012HI14 1055 COMMERCE AVENUE OO s N $2o17FBC RWN FUH 12285 VERO BEACH,FL 32960 CORPORATE OFFocF A m tri p AmmFee CCD RNN 1ate2D (772)569-2200 1605W 12th AVE,SIT1®6 '3— ra000nwonevxwunalwxt. DEERFIELD BEACH,-YL 93 i01 1Dow,m.r[umnuuwraewceu®n "IMPACT"ALUMINUM COLONIAL SHUTTER 19511 I( )7 rwFwr.Rrm,xnn..crnRm+srxrarraawt. 2 C lAl OFMWgO,vE-mouroa,emmn, MIAMI-DADE NOTICE OF ACCEPTANCE 7EANOENGINEEIUNGE7ceacSf.EE��OQ @R R0a0m4mana„WwLtroraxCaur ENGINEERINGEXPRESS.EpM�e- 0 \\ uE.olvfA�Rl®I.0 mudRaAGmRAnbl / ,V .� .1 i .\ ��II111111111\•