Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
8199 Blackbead Ct
All APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: Permit Number: no L=0 ' - P Ell A, Building Permit Application Planning and Development Services Building and Code Regulation Division Commercial Residential X 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 PERMIT APPLICATION FOR: AC CHANGE OUT PROPOSED IMPROVEMENT LOCATION: Address: 8199 BLACKBEAD CT Property Tax ID #: 2423-701-0018-000-5 Lot No.1 Site Plan Name: Block No. 1 Project Name: THADDEUS CHERWIN DETAILED DESCRIPTION OF WORK: AC CHANGE OUT 3 TON / 8KW / 14 SEER New Electrical Meter Second Electrical Meter CONSTRUCTION INFORMATION: Additional work to be performed under this permit— check all that apply: KMechanical _ Gas Tank —Gas Piping _ Shutters _ Windows/Doors Pond Electric _ Plumbing _ Sprinklers _ Generator Roof Pitch Total Sq. Ft of Construction: Sq. Ft. of First Floor: Cost of Construction: $ 4954.50 4 Utilities: —Sewer _ Septic Building Height: OWNER/LESSEE: CONTRACTOR: Name THADDEUS CHERWIN Name: MICHAEL FORGIONE Address:8199 BLACKBEAD CT Company UNIVERSAL AIR & HEAT City: PORT ST LUCIE State: Address: 5460 W STATE RD 84 # 12 Zip Code: 34952 Fax: City: DAVIE State: FL Phone No.917-902-5711 Zip Code: 33314 Fax: 954-318-0584 E-Mail: Phone No 954-581-7110 Fill in fee simple Title Holder on next page ( if different E-Mail Permitting@Uahac.com from the Owner listed above) State or County License CAC058142 If value of construction is 2500 or more, a RECORDED Notice of Commencement is required. If value of HAVC is $7,500 or more, a RECORDED Notice of Commencement is required. SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION: DESIGNER/ENGINEER: Not Applicable Name:_ Address: City: Zip: Phone FEE SIMPLE TITLE HOLDER: Name: Address: City: Zip: Phone:_ State, MORTGAGE COMPANY: Name: Address: City: Zip: Phone:_ Not Applicable State: _ Not Applicable BONDING COMPANY: Not Applicable Name: Address: City: Zip:. Phone OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated. I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie. County makes no representation that is granting a permit wili authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in paying twice for improvements to your property. A Notice of Commencement must be recorded in the public records of St. Lucie County and posted on the jobsite before the first inspection. If you inte d to obtain financing, consult with lender or an attorne► €are commencing work or recording vouc Not4 d of Commencement. Signature of ctor as AVent for Owner I Signature STATE OF FLORIDA STATE OF FLORIDA COUNTY OF �ax_�� COUNTY OF �►� Sworn to (or affirmed) and subscribed before me of Physical Presence or Online Notarization this day of___ 2QJa by Name of person making statement. Personally Known rY OR Produced Identification Type of Identification Produced (Signature of Notary Public- S to 4iPkrrid44tary Pubhc State of -I _ .S 'ie PagUra Commission Na. — �(S oMrnissian 22 15[ ersL �res 02/0212022 REVIEWS FRONT ZONING SUPERVISOR COUNTER REVIEW REVIEW DATE RECEIVED DATE COMPLETED nse Holder Sworn to (or affirmed) and subscribed before me of 7C Physical Presence or Online Notarization this a. day of 4�, ? 2-= by � a-1 Name of person making statement. Personally Known 01�, OR Produced Identification Type of Identification Produced re of Notary ission No. PLANS VEGETATION REVIEW REVIEW State of Florida anPWsya Expires. xp es Q GZ'2fl2G 150367 SEA TURTLE MANGROVE REVIEW I REVIEW Michelle Franklin, CFA -- Saint Lucie County Property Appraiser -- All rights reserved. Property Identification Site Address: 8199 BLACKBEAD CT S ec/Town/Range: 25/36S/40E Parcel ID: 3425-701-0018-000-5 Jurisdiction: Saint Lucie County Ownership Thaddeus T Cher -win 8199 Blackhead CT Port St Lucie, FL 34952 Legal Description SAVANNA CLUB -PLAT ONE- BLK 1 LOTI (OR 3256-2138) Current Values Just/Market Value: $84,000 Assessed Value: $67,806 Exemptions: $43,306 Taxable Value: $24,500 Property taxes are subject to change upon change of ownership. • Past taxes are not a reliable projection of future taxes. • The sale of a property will prompt the remnral of all exemptions, assessment caps, and special classifications. Taxes for this parcel: SLC Tax Collectoes Office 12 Download TRIM for this parcel: Download PDF 12 Use Type: 0200 Account #: 115028 Map ID: 34/25S Zoning: Planned Un Total Areas Finished/Under Air (SF): 1,222 Gross Sketched Area (SF): 2,001 Land Size (acres): 0.2 Land Size (SF): 8,515 Building Design Wind Speed Occupancy Category I II III & IV Speed 140 160 170 Sources/links: All information is believed to be correct at this time, but is subject to change and is provided without any warranty. © Copyright 2021 Saint Lucie County Property Appraiser. All rights reserved. State License # UNIVERSAL \— AIR & HEAT— Brand: Goodman VGCAL.C'%e- I;PC, t�-A Hours for lead installer 1 Digital Thermostat Thaddeus Cherwin 8199 Blackbead Ct Port St. Lucie, FL 34952 1 Strap, Tape, Mesh, Mastic Supply & Return Connections To Ensure No Air Leaks 1 Mediclean Microbial Treatment (Value $399.00 Per HVAC Zone) 1 Sheet Metal Dog House Covering Supply & Return Ducts 2 Locking Caps For Freon Valves 4 Hurricane Tie Downs ( up to code ) 4 Vibration Isolator Pads Under The Package Unit Hooked Up To Property owners Existing T-stat, Electrical, stand, slab & Duct Work ( unless otherwise noted for replacement on this invoice/estimate) ( If unit is located on the roof the Property owner will be Responsible To Hire Roofer if needed ) 1 Year Labor Warranty 10 year factory parts in unit warranty 1 Concrete Slab Clean Up Job site & Legal Disposal Of Old HVAC Equipment Properly Level Unit Sealed Equipment Connections Sub Cooled/Superheat Refrigerant Charging * Any Electrical Upgrades Are The Property Owners Responsibility *50% Deposit Is Due Upon Arrival Of Installation And Balance is Due as payment in full Upon Ac startup * * Price Is Only Valid For 30 Days * 1 Mechanical permits are not induced in this price and must be paid separately. We do not mark up the cost of the city permit fee. This fee can be paid directly to the city. Customer Technician Thaddeus Cherwin Ref #: 207122 Customer Order 207122 SUB -TOTAL $4,954.50 INSTANT REBATE $346.82 - UTILITY REBATE - MANUFACTURE REBATE - DEPOSIT TRIP CHARGE TOTAL AMOUNT DUE $4,607.68 217 �Nl" Customer Order State License # Thaddeus Cherwin 207122 _ERSAL Southeast Florida Port Blackhead 3 A 1 R & HEAT — Port St. Lucie, FL 34952 •+I��—.--� 1 Invoice We Propose To Furnish And Install A New 3 Ton 14 SEER Goodman. Options: Choose from one of 10 payment options. Option #1 Cash,Check or Credit Card Price Before Rebates: $4,954.50 - Instant Rebate $693.63 Total Cost $4,260.87. Cash, Check or Credit Card Option #2 Wells Fargo Financing Price Before Rebates: $4,954.50 - Instant Rebate $594.54 Total Cost $4,359.96. 0% Interest if paid in full within 6 months Option #3 Synchrony Financing Price Before Rebates: $4,954.50 - Instant Rebate $545.00 Total Cost $4,409.50. 0% APR for 25 months with equal payments of about $176.38 with approved credit and terms. Option #4 Synchrony Financing Price Before Rebates: $4,954.50 - Instant Rebate $445.91 Total Cost $4,508.59. 0% APR for 36 months with equal payments of about $125.24 with approved credit and terms. Option #5 Synchrony Financing Price Before Rebates: $4,954.50 - Instant Rebate $346.82 Total Cost $4,607.68. 0% APR for 48 months with equal payments of about $95.99 with approved credit and terms. Option #6 Synchrony Financing Price Before Rebates: $4,954.50 - Instant Rebate $242.77 Total Cost $4,711.73. 0% APR for 60 months with equal payments of about $78.53 with approved credit and terms. Option #7 Wells Fargo Financing Price Before Rebates: $4,954.50 Total Cost $4,954.50. 0% APR for 60 months with equal payments of about $82.58 with approved credit and terms. Option #8 Ygrene Financing Price Before Rebates: $4,954.50 - Instant Rebate $606.93 Total Cost $4,347.57. 7.49% APR for 120 months with equal payments of about $62.64 with approved credit and terms. This Option will be added to the yearly county property tax bill of about $751.68 per year. Option #9 Okinus Financing Price Before Rebates: $4,954.50 - Instant Rebate $495.45 Total Cost $4,459.05. Read Okinus Credit Solutions agreement for details. Text Okinus 6444 to 484848 and you'll receive an online application link to apply now. Option #10 Synchrony Financing Price Before Rebates: $4,954.50 - Instant Rebate $346.82 Total Cost $4,607.68. 9.99% APR for 132 months with equal payments of about $57.66 with approved credit and terms. Customer Technician 214 Thaddeus Cherwin Ref #: 207122 �.�� State License # UNiYERSAL AIR& HEAT — • MAKE ALL CHECKS PAYABLE TO UNIVERSAL AIR & HEAT Thaddeus Cherwin 8199 Blackbead Ct Port St. Lucie, FL 34952 Customer Order 207122 • All Services performed under the warranty policy will be provided by Universal Air & Heat during normal Business Hours, Monday to Saturday. Business hours being 8:00 to 5:00 p.m., Monday through Friday 8:00 am to 5:00 p.m. Saturday. Warranty does not cover or include routine maintenance such as changing/cleaning filters, breaker tripping or replacing fuses. • It shall be at the discretion of Universal Air & Heat and its Technician to repair or replace defective parts, units or materials whenever is necessary. Any Nuisance calls beyond the scope of this agreement will be charged at our normal service rate and/or emergency rates. • Any alteration or deviation from the proposed specifications or conditions involving extra cost of materials or labor will only be executed upon the written order for the same and will become an extra charge over the sum mentioned in this contract. The terms and conditions set forth in this agreement are the only agreement between the parties, any inconsistent term or condition is not part of this agreement unless it is in writing and sighed by the customer and Universal Air & Heat. Title to the equipment and other materials will remain with Universal Air & Heat until all sums due us have been paid in full. • All balances not paid within 30 days of the bill date will be subject to a monthly service charge in the amount of 1.50% of the outstanding balance. Customer is responsible for all cost of collection, including reasonable attorney's fees in the event of non - payment. In the event that any person/customer files suit against Universal Air & Heat if such case is found in favor of Universal Air & Heat customer will pay all cost including reasonable attorney's fees. • Customers acknowledges and understands that the cleaning of A/C ducts and registers may present a danger to any persons or animals in the job site due to the release of potentially dangerous airborne particles (including mold and dust). Customer is solely responsible to provide for the safety of all persons, pets and things at the job site. Customer is solely responsible for any harm suffered by any person therein. Customer agrees to hold Universal Air & Heat harmless and indemnify Universal Air & Heat for any damages related to the cleaning, removal or replacement of ducts, registers or other equipment. Universal warrants existing drain line hookups for 30 days with new equipment installed or serviced. Universal Air & Heat will use nitrogen to blow out drain lines and assumes no responsibility for water damage of any kind. Update 7/2/2016 Customer acknowledges, understands and is fully aware that new high efficiency HVAC 14 seer and above system's will require more frequent regular maintenance to any new or existing drain line and such maintenance is not included in this contract unless otherwise expressed in writing and agreed to by customer as well as a representative of Universal Air & Heat. Universal Air & Heat recommends flushing new or existing drain lines once every four months in efforts to achieve optimal performance and reduce the possibility of an accidental water loss occurring. Universal Air & Heat is not responsible for any water damage, wall painting, framing, and wall covering, equipment delay or any other inconvenience other than that of mechanical failure. Universal Air & Heat agrees to use reasonable efforts to run duct work within existing walls, ceilings and soffits. Customer acknowledges that the work performed may require the construction of soffits or other enclosures to conceal ductwork or other equipment and customer shall pay for all cost associated with the construction of same. • Universal Air & Heat has the right stop all work if payments as set forth herein are not made upon the due date. Once any equipment/materials have been delivered at the job site, it is the residential/Commercial property owner's or the General Contractor's responsibility to care for them. • Universal Air & Heat can and has the option to pick up any parts, equipment, units, etc., if payments as set forth herein are not made upon the due date from any and all properties, where such equipment, air conditioning units, and parts exist. • Any & All parts, equipment, supplies, etc., that have not been paid for shall remain the property of Universal Air & Heat until the balance is paid in full. • Upon acceptance this proposal sets forth the entire agreement of job between both parties. Warranty: • We warrant new air conditioning equipment for a period of one year ( unless otherwise stated in the description above and signed by a rep from Universal Air & heat) from the date of installation that material and labor furnished by us will be free from defects. • Universal Air & Heat warrants that for 30 days from the date of any repair, all products will be free from defects in materials workmanship — except the air conditioner system compressor which is also warranted for 1 or 5 or 10 years on the part only subject to brands and models of the manufacturer. Copies of warranties are provided upon installation of new air conditioning equipment. • Under this warrant, Universal Air & Heat has the first option to repair the equipment or provide replacement parts. • THE LIABILITIES SET FORTH ABOVE ARE IN LIEU OF ALL OTHER WARRANTIES AND LIABILITIES. EXPRESSED OR IMPLIED, IN LAW OR IN FACT, INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY FOR PARTICULAR USE. Thaddeus Cherwin Ref #: 207122 This combination qualifies for a Federal Energy Efficiency Tax Credit when placed in service between 1/1/2015 and 12/31/2020. Certificate of Product Ratin AHRI Certified Reference Number: 200945843 Date : 04-02-2021 Model Status : Active Old AHRI Reference Number: 6892357 AHRI Type : SP-A (Single -Package Air -Conditioner, Air -Cooled) Series: GPC14 Outdoor Unit Brand Name: GOODMAN Outdoor Unit Model Number (Condenser or Single Package) : GPC14361-141 D* Region : All (AK, AL, AR, AZ, CA, CO, CT, DC, DE, FL, GA, HI, ID, IL, IA, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, RI, SC, SD, TN, TX, UT, VA, VT, WA, WV, WI, WY, U.S. Territories) Region Note. Central air conditioners manufactured prior to January 1, 2015 are eligible to be installed in all regions until June 30, 2016. Beginning July 1, 2016 central air conditioners can only be installed in region(s) for which they meet the regional efficiency requirement. The manufacturer of this GOODMAN product is responsible for the rating of this system combination. Rated as follows in accordance with the latest edition of AHRI 210/240 with Addendum 1, Performance Rating of Unitary Air -Conditioning & Air -Source Heat Pump Equipment and subject to rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (A2) - Single or High Stage (95F), btuh : 35600 SEER: 14.00 EER (A2) - Single or High Stage (95F) : 12.00 t"Active" Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale; OR new models that are being marketed but are not yet being produced "Production Stopped" Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still selling or offering for sale. Ratings that are accompanied by WAS indicate an involuntary re -rate. The new published ratino is shown_ along with the previous (i.e. WAS) rating, DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahrldlrectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for Individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; Am entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. AIR-CONDITIONING, HEATING, CERTIFICATE VERIFICATION & REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at www.ahridirectory.org, click on "Verify Certificate" link we make life better - and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above, and the Certificate No., which is listed at bottom right. 02021 Air -Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 132618546244468254 IZIO ENGINEERING Q '-'EXPRESS 12 Ct,.E.R.T. (Engineering Express Product Evaluation Report) 160 SW 12TH AvE SUITE 106, DEERFIELD BEACH, FL 33442 (954) 354-0660 i ENGINEERINGEXPRESS'.COM Technical Evaluation Report DIVISION: 23 08 00—COMMISSIONING OF HVAC THIS DOCUMENT CONTAINS (5) PAGES: THE FIRST PAGE MUST BEAR AN ORIGINAL SIGNATURE & SEAL OF THE CERTIFYING PE TO BE VALID FOR USE (issued February 1, 2018 Subject to Renew August 1, 2019) (or next code cycle change) REPORT HOLDER: GOODMAN COMPANY, L.P. 5151 SAN FELIPE STREET HOUSTON, TX 77056, USA 4=0 877-254-4729 1 GOODMANMFG.COM SCOPE OF EVALUATION (compliance with the following codes): THIS IS A STRUCTURAL (WIND) PERFORMANCE EVALUATION ONLY. - NO- ELECTRICAL OR TEMPERATURE PERFORMANCE RATINGS OR CERTIFICATIONS ARE OFFERED OR IMPLIED HEREIN. This Product Evaluation Report is being issued in accordance with the requirements of the Florida Building Code Sixth Edition (2017) per FBC Section 104.11.1, FMC 301.15, FBC Building Ch. 16, ASCE-7-10, FBC Existing Building sections 707.1, 707.2, FBC Building 1522.2, and FBC Residential M1202.1, M1301.1, FS 471.025, including Broward County Administrative Provisions 107.3.4. The product noted on this report has been tested and/or evaluated as summarized herein. IN ACCORDANCE WITH THESE CODES EACH OF THESE REPORTS MUST BEAR THE ORIGINAL SIGNATURE & RAISED SEAL OF THE EVALUATING ENGINEER. SUBSTANTIATING DATA: • Product Evaluation Documents Substantiating documentation has been submitted to provide this TER and is summarized in the sections below. • Structural Engineering Calculations Structural engineering calculations have been prepared which evaluate the product based on comparative and/or rational analysis to qualify the following design criteria: • Maximum allowable unit panel wind pressure connection integrity • Maximum allowable uplift, sliding, & overturning moment for ground and roof applications Calculation summary is included in this TER and appears below. NOTE: No 33% increase in allowable stress has been used in the design of this product. Microsoft Excel was used to carry out the calculations present in this report. INSTALLATION: The product(s) listed above shall be installed in strict compliance with this TER & manufacturer -provided model specifications. The product components shall be of the material specified in the manufacturer -provided product specifications. All screws must be installed in accordance with the applicable provisions & anchor manufacturer's published installation instructions. LIMITATIONS & CONDITIONS OF USE: Use of this product shall be in strict accordance with this TER as noted herein. See final page for complete limitations and conditions of use. OPTIONS: This evaluation is valid for all GOODMAN models present in the table located on the final page. 'INISH: aked enamel. TER-16-3147.3 Edition (2017) NOTE: GRAPHICAL DEPICTIONS IN THIS REPORT ARE FOR ILLUSTRATIVE PURPOSES ONLY AND MAY DIFFER IN APPEARANCE UNIT CASING MATERIAL: 24ga FS galvanized sheet steel ASTM A653 CS cold rolled steels For side covers_ 20ga EDDS galvanized sheet steel ASTM A653 cold rolled steel for bottom base pan. 20ge EDDS galvanized sheet steel ASTM A653 cold rolled steel for top panel. Removable top & side covers secured with 910-16 sheet metal screws. Knockouts provided for utility & control connections. INSTALLATION: Shall follow manufacturer specifications as well as the information provided herein. STRUCTURAL PERFORMANCE: Models referenced herein are subject to the following design limitations: ASCE-710 Exposure Categories C & D Up to and Including 175mph (Vult) for up See page 2. HVHZ°'" Up to and including 170mph (Vult) for up to See page 2. HVHZ"" Up to 200mph (Vult) for up to 56' MRH". Non-HVHZ' Exp. C Ground or Roof Application per installation instructions "Mean Roof Height `"High Velocity Hurricane zone Maximum Rated Wind Pressure: 193psf Lateral 93psf Uplift (less Dead Load) Site- specific wind analysis may produce alternate limitations provided N+C.7a W C W I IUL eAGeeQeD. ORIGINAL SIGNATURE AND RAISED SEAL OR DIGITAL SEAL REQUIREDITO BE VALID PER CODE: Frank L. Bennardo, P.E., S ENGINEERING EXPRESS® ❑ Signed by If Checked: Gordon DiBattisto, PE FL PE #0046549 FLCA #af9$85 FL PE #82328 NOTICIE.• IF 7HI5 PAGE pOES NOT CONTAIN ORIG NAt SIG NA RE & ENGINEER SEAL: IF THERE I S A DIGITAL SIGNATURE oN PAGE 1.THIS DOCUMENT IS PART OF A DIGITALLY SIGNED FILE, SHALL REMAIN IN DIGITAL FORMAT & PRINTED COPIES OFTHIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED. IF THERE IS NO DIG rrAL S IG NATUR E ON PAGE 1 OR THIS PAGE DOES NOT CONTAIN AN ENGINEER'S ORIGINAL SIGNATURE & SEAL, THIS DOCUMENT IS A COPY/DRAFT- . wljylrurrr w cu ro Grry,rmenng expresSw I rranx L. Bernardo PE, inc. All Rights Reserved e FRC 6" Edition (2017) defines APPROVED SOURCE (section 202) as 'An independent Person, firm or corporation, approved by the building official, who is competent and experienced in the application ?n4rleenng principles to materials, methods or systems analyses.' Engineering Express@ professionals meet the competency requirements as defined in the FBC and can seal their work. Engineering Express@ agulady engaged in canducting and providing engineering evalu*ons of sngls-element and full-scale Cuitding systems tests. 14 GOODMAN PACKAGE SYSTEMS Engineering Express° I TER-16-3147.3 SECTION 2 PRODUCT INSTALLATION 0 Roof or ground structure / substrate (concrete, steel, aluminum see schedule below) n clips. See elow for ations TIE -DOWN CABLE & CLIP SCHEDULE 00 TIE -DOWN CLIP (GROUND APPLICATION) Miami Tech CUTD 1" ASTM A653 galvanized steel 0.07" thick (FL19731.2) for all cabinets tied down at ground; fasten clip to structure using anchor from Anchor Schedule to Host Structure Table and (4) #10-16 x 3/8" SS 410 self -drilling screw to fasten clip to unit -base Mall. Install 6" from the unit corners with quantity as shown in table. Roof Roof Bottsto Screwto Cabinet Height} Height+ Tie -down Cable Cable Min. Tie -down Cable Diameter wLL(Ibs) ExC Exp D Stand per Curb per p side side Curb gage Clips per long side Tie -down Cable Tyne: (for roof applications) Ground Ground NA NA NA NA NA 15' (20') - NA NA NA NA 3 - 7x7 Galvanized cable for industrial and marine application. 4 4 H1 60' (W) 25' (35') NA NA NA 4 14 Np - Minimum edge distance 3" from the unit comers. 4 12(' (150') 0105.) 2 5/32" 520 2 14 NA - Use two tie -down cables per unit. 4 200 (250') 115' (350. 2 3/16" 740 2 4 11 ll NA NA Ground Ground NA NA NA NA NA NA 3 Note: H2, M2, 15 (20) - NA NA NA 4 4 14 NA Tie•down cable shall be wrapped around roof stand post and shall M2 60'(W) 25'(35') 2 5/32" 520 2 4 14 NA be tightened around the unit using the turnbuckle. Provide two 12U (150') 60' (85') 2 3/16" 740 2 4 11 NA cables per unit and one turnbuckle per cable. Neoprene pad shall 2W (250') 115' (W) 2 3/16" 740 2 4 ]1 NA be placed under the cable to prevent distortion to the cabinet. Ground Ground NA NA NA NA NA NA 3 Equivalent cable is permitted using the minimum WLL per height 15' (20) NA NA NA 4 4 14 NA H3, M3 60' (W) 25 (35) 2 5/32" 520 2 4 14 NA 120' (1W) 60' 185) 2 3/16" 740 2 4 11 NA 2W (250') 115' WW) 2 3/16" 740 2 4 11 NA Ground Ground NA NA NA NA NA NA 3 ANCHOR TO HOST STRUCTURE SCHEDULE 15' (20') - NA NA NA 4 4 14 NA H4, M4 60' (80') 25' (35') 2 5/32" 520 2 4 14 NA AnchorT e 120' (150') fe (85') 2 3/16" 740 2 q 11 NA Roof Roof 2W (250') 115' (15U) 2 3/16" 740 2 4 11 NA Cabinet Height Height Concrete 1/8" Min 1/8" Min A365teel Exp C Exp D 3 ksi A36Steel 6061-T6 Curb * Alum The value shown in parentheses indicates the allowable roof height Ground Ground A NA NA NA in 170mph conditions. i.e. 60' (80') indicates an allowable roof height 15 20 NA B B D of 60' for 175mph or 80' for 170mph Vult. H3 60' W 25' (35') NA g g Ip 12Y LSD' 60' (B-5') NA C C D 200 50' 115' (150') NA C C D Anchor Types to Host Structure: Ground Ground A NA NA NA H2, M1, 15' (20' - NA B B D A. —1/4" ELCO ULTRACON SS4 Anchor embedded 3" in 3,000 psi M2 60' ' 25' (35') NA B B D concrete. 2 1/2" from edge minimum. 120 150 60 85) NA C C I D B. —1/4" SAE Grade 5 screw minimum 1/2" from edges with nut and 200 250 115'( NA C C D washer OD 0.75" Grpund Ground A NA NA NA C. — 5/16" SAE Grade 5 screw, minimum 1/2" from edges with nut and 15' 20 NA B B D washer OD 0.75" H3, M3 61, 80' 25'(35') NA C C p D. — 5/16" Sheet metal screw, Grade 5. 120'2W 60 1' (85') NA 200' 250' 115- {150'} NA C C p NA. - No anchors apply. Ground Ground A C NA C NA D NA 15' 20' - NA B B D Note: H4, M4 60' >30' 25' (35') NA C C D Screw length to tie cabinet to curb shall be verified on site. 120 115or 60. (!65') NA C C D 200' 250 115' {150') NA C C D IN ALL CONDITIONS IT IS THE RESPONSIBILITY OF THE PERMIT HOLDER TO ENSURE THE HOST STRUCTURE IS CAPABLE OF WITHSTANDING THE RATED GRAVITY, LATERAL, AND UPLIFT FORCES BY SITE -SPECIFIC DESIGN. NO WARRANTY OF ANY KIND, EXPRESSED OR IMPLIED, IS OFFERED BY ENGINEERING EXPRESS AS TO THE INTEGRITY OF THE HOST STRUCTURE TO CARRY DESIGN FORCE LOADS INCURRED BY THIS UNIT. ENGINEERING EXPRESS® 160 SW 12TH AVE. SUITE 106 DEERFIELD BEACH, FL 33442 Page 2 (954) 354-0660 ENGINEERINGEXPRESS.COM Copyright©2018 Engineering Express® / GDODMAN PACKAGE SYSTEMS Engineering Express° I TER-16-3147.3 CABLE AND BOLT LAYOUT NFCIPRFNF Pan— L=I=0000 000000 oe000e 000000 Deeeeo 000000 0000q© 000000 oc��o�q c dodo 0 o a� ao oo�e� c�dog SEEANCHOR TO HDST STRUCTURE SCHEDULE TABLE TIE DOWN CABLES SEE TIE DOWN SCHEDULE PACKAGE UNIT SHELL ENCLOSURE + r TURNBUCKLE ENCLOSUREAND I BASE RAIL FASTENER 0 SEE ANCHOR TO UNIT BASE RAIL HOST STRUCTURE SCHEDULETABLE ROOFSTAND PER SEPARATE ROOF STAND ENGINEERING TIE DOWN CABLES PER SEPARATE — - - SEE -TIE -DOWN — ENGINEERING SCHEDULE TN TYPICAL ROOF MOUNT ON STAND_ SCALE: N.TS. ELEVATION VIEW NFOPRFNF PAnt 000coo ©cce�e�c L��dgp�ry e�d�ad1� O t�o�d oq CCCgdC� do�t�oz— L�L�dq© ©dco� r�c5oo �400 o b c�000 0 A STAND ATTACHMENT DETAIL SCALE: N.TS. aEC vTm TIE DOWN CABLES PACKAGE UNIT SEE TIE DOWN SCHEDULE TYPICAL TURNBUCKLE SCREW PLACEMENT ALTERNATIVE UNIT BASE RAIL SCREW PLACEMENT MACHINERY EYEBOLT SAE BASE RAIL TO GRADE 5 WITH SHOULDER CURB ANCHOR Sib'-11 x 1-W ROOFCURB PER SEPARATE ENGINEERING 2 TYPICAL ROOF MOUNT ON CURB =CALF:.-T.S. E EVAT[pN V Ex CURB MOUNT OPTION - OETAiL B I ` — — — g — — I � I I I I I ROOF STAND MOUNT ANCHOR ATTACHMENT OPTION-DETAILA TO HOST I � I I 1 CABLE ATTACHMENT TO HOST I SEE DETAILS AAND B � I l � ROOF STAND RAIL UNIT BASE RAIL I I k a VAr1ES VARIES V69 SHELL ENCLOSURE ENCLOSURE AND BASE RAIL FASTENER TIE DOWN CABLES SEE TIE DOWN SCHEDULE CURB FRAME I MACHINERY EYEBOLT SAE PER SEPARATE r GRADE 5 WITH SHOULDER ENGINEERING I �•-11 x 1-�' 8 CURB ATTACHMENT DETAIL SURE: N-T-5. SrCT M VIE WHE W J iIPROVIDE1X--SAE [ GRADE 5 WASHER I� f I ! IPRO VIDE5A§'OSAE GRADE 5NUT I Z III BED OF IOFINGEBOLT SAE GRADE 5 WITH SHOULDER %"-11 x 1--' CURB FRAME PER SEPARATE ENGINEERING SEE THICKNESS REQUIREMENTS IN REPORT — 3 BASE RAIL ATTACHING TO HOST (FIELD INSTALLATION EYE BOLT DETAIL SCALE: ALTS RAM1 NEVI ac.W: N.ra. DEO111 t5w ENGINEERING EXPRESS® 160 SW 12TM AVE. SUITE 106 DEERFIELD BEACH, FL 33442 Page 3 (954) 354-0660 ENGINEERINGEXPRESS.COM COPYrigh[©2018 Engineering Express® / Frank I Rcnn.rAn DC Inv all IX..61e D...........w GOODMAN PACKAGE SYSTEMS- Engineering Express® I TER-16-3147.3 SECTION 4 SUPPORTING CALCULATIONS & SUMMARY FORCES SUMMARY Cabinet Outside Dimensions D (in) W (in) H (in) 66.00 33.00 35.50 Weight range (Ibs) Ground or Roof Height* Ground Lateral Pressure (Psf) 40.9 Uplift Pressure (Psf) 0 Max Side Force (Ibs) 722.0 Max SideLTen Overturn (Ibs-in) x e ion s) Max Uplift Force (Ibs) 77865 120.0 0.0 H1, H2, H3 66.00 33.00 35.50 15' (20') 116.6 56.5 2059'0 47608.8 999.0 854.6 H4 66.00 33.00 35.50 350 to 405 60' (80') 151.0 73.1 2665.0 63439.7 1326.0 1105.0 66.00 33.00 3550 120 {150') 173.7 84.1 3065.0 73872.4 1542.0 1271.0 66.00 33.00 35.50 200' {250'} 192.9 93.4 3404.0 82729.5 1702.0 1471.0 51.00 47.00 42.75 Ground 409 0 619.0 1579.1 110.0 0.0 M1, M2, M3, 51.00 47.00 42.75 15' (20') 116.6 56.5 1766'0 48179.1 1108.0 940.0 M4 51.00 47.00 42.75 412 to 496 60' (80') 151.0 73.1 2287.0 65814.1 1478.0 1217.0 51.00 47.00 42.75 120 (150') 173.7 84.1 2630.0 7735.7 1722.0 1399.0 -51.00 47.00 42.75 200' (250') 192.9 93.4 2921.p._ �73Q21_ .1924.0 1554.0 PANEL INTEGRITY SUMMARY Note: Calculations performed according to the information provided by the client. Cabinets were assumed solid (0% Porosity) for shear and tension ealculatlon purposes. Screw quantities were checked to reinforce unit Panels as needed, They shall be spaced evenly throughoutthe panel bottom part, validating that the serew)oins the panel with the supporting element. Screw sires, quantities on panel, and Pane? characteristics are according to client's description. Thousand hours of ASTM 5117 are required with zero red rust far any additional straw. ENGINEERING EXPRESS® 160 SW 12TM AVE. SUITE 106 DEERFIELD BEACH, FL 33442 Page 4 (954) 354-0660 ENGINEERINGEHPRESS.COM Copyr ght ® 2018 Engineering ExpressO I Frank L. Bernardo PE, Inc. All Rights Reserved GOODMAN PACKAGE SYSTEMS Engineering Express® I TER-16-3147.3 MODEL, CABINET AND DIMENSIONS W H End Lower Goodman Model No. Cab. Goodman Model an Cab. Goodman Model No. GPG1624"`M41" M2 GPC1536H41" H1 GPH1530M41" GPG1630" M41" M2 GPC1542H41" H1 GPH1536M41" GPG1636"`M41" M2 GPC1548H41" H2 GPH1542M41" GPG1642—M41" M4 GPC15601 1 H2 GPH1548M41" GPG1648—M41" M4 GPH1424H41" H3 GPH1560M41" GPC1424Ii41(C,D,E)' H1 GPH14301-141" H3 GPH1624M41" GPC1430H41(C,0,E)' H1 GPH1436H41" H4 GPH1630M41" GPC1436H41" H1 GPH1442H41" H4 GPH1636M41" GPC1442H41" H2 GPH1448H41" H4 GPH1642M41" GPC1442H41" H1 GPH1460H41— H4 GPH1648M41" GPC1448H41" H3 GPH1624H41" H3 GPG1424;;;'M41" GPC1448H41" H2 GPH1630H41" H3 GPG1430"`M41" GPC1460H41* H3 GPH1636H41" .. H4._ 0P_G.143fi"_'M41" GPC1460HW H2 GPH16421-141" H4 GPG1442"'M41" GPC1424M41" M2 GPH1648H41" H4 GPG1448"'M41" GPC1430M41" M2 GPH1424M41" M2 GPG1460"`M41" GPC1436M41" M2 GPH1430M41" M2 GPG1524—M41" GPC1442M41" M2 GPH1436M41" M2 GPG1530—M41" GPC1448M41" M4 GPH1442M41" M2 GPG1536—M41" GPC1460M41" M4 GPH1448M41" M4 GPG1542"'M41" GPC1524H41" H1 GPH1460M41" M4 GPG1548""M41" GPC1530H41" H1 GPH1524M41" M1 GPG1560"`M41" " Goodman nomenclature for models r' r� H Cabinet H i Cab. M1 M1 M3 M3 M2 M2 M2 M4 M4 M4 Cabinet D (in) W (in) H (in) Weight (Ibs) H1 33 66 30.50 300 to 350 H2 33 66 35.50 360 to 370 H3 33 66 38.50 315 to 375 H4 34 66 35.00 375 to 405 M1 51 47 32.50 380 to 420 M2 51 47 34.75 376 to 495 M3 51 47 40.00 449 to 453 M4 51 47 42.75 475 to 496 I C Side Lower Top Side Lower I A I B C A Ill 6 End Lower E I Models GPG1424, GPG144S. GPG1536. GPG1,960. GPC1442H41". GPC1448H41", GPC1460H41 GPHI460H4I- were analyzed, any discrepancywith panel distribAnn is the manufacturers responsibility. LIMITAT?ON5 & CONDITIONS OF USE; Llse Of this product shall be in strict accordance with this TER as noted herein. The supporting host structure shall be designed to resist all superimposed loads a= deiermined by others on a site specific basis as may be required by the Authority Having Jurisdiction, Host structure conditions which are not accounted for in this product's no anchor schedule shalt 6e designed on a sit_�speCific basis by a registered Rrofessional engineer. No evaluation is offered for the host Supporting structure by use of this document; Adiusbnenl factors noted herein and the applicable Codes Mgt be considered, where applicable. Air supporting components which are permenenfly installed shall be protected against corrosion, contamination, and other such damage at all Gases. Fasteners must penetrate the supporting members such that the full length of the threaded portion Is embedded within the main member, All anchors, screws, straps, Gips, and attachment pan can be substituted for equivalent parts, as ION as the capacilfes of the equivalent parts are equal or stronger. Unit integrity is not mandatory; however, this TER certifies regardless_ This evaluation does not offer any evaluation to meet rarge rnissile impact debris requirements which lypi�lly are not required for this" of product- Al of the vwnd resisting exferior pavers, Indlvidually meet or exceed their capacity to resist the design wind toads as stated in the calculagons as required by the Florida WICUng Code Sixth Ebition (2017). flue to the indaterminala nature of these units. distortion and eeflecllon cannot be accurately evaluated, but with diaphragm action of eXtemal componenls and internal stiffeners, the base unit has the cape oily to vathsia rid these forces wi to inrrvl dual external parts being contained. yearly inspeclidns, during equipment maintenance or afie+ a named sirocco; all screws, r�binet [ampbnents, clips, anchor, bolls, straps and cables are to be verified by the AC contractor. All damaged cabinet components, loose, corroded, broken screws or anchor bot[5 shall be replaced to ensure structure] integrity for hurricane wind Forces. ENGINEERING EXPRESSM 160 SW 12TH AVE. SUITE 106 DEERFIELD BEACH, FL 33442 Page 5 (954)354-4660ENGINEERINGEXPRESS.COM CopN'igh[02018EngineeringExpressS I Frank L. Hennerdo PE, lnc. All Rights Reserved