HomeMy WebLinkAbouthealth departmentSTATE OF FLORIDA DEPARTMENT OF HEALTH c titaQ ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM .y CONSTRUCTION INSPECTION AND FINAL APPROVAL APPLICANT: Benjamin Taylor & Heather Phillips AGENT: Pace 2000, Inc PROPERTY ADDRESS: 10700 Carlton Rd Port Saint Lucie, FL 34987 LOT: BLOCK: APPLICATION # : AP 147'9 285 PERMIT #:56-SF-2044630 DOCUMENT # : FI 1606154 DATE PAID:03/04/2020 FEE PAID:545.00 RECEIPT #:56-PID-4304508 SUBDIVISION: ID # : 4210-323-0004-000-7 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ ] [01] TANK SIZE (1] 1090.00 [21 [ ] [27] SURFACE WATER 100 FT [ ] [021 TANK MATERIAL Polypropylene [ ] [28] DITCHES FT [ ] [031 OUTLET DEVICE [ ] [291 PRIVATE WELLS 96 FT [ ] [041 MULTI -CHAMBERED (LIJ N ] [ ] [301 PUBLIC WELLS FT [ ] [051 OUTLET FILTER Polylok PL-68 [ ] [311 IRRIGATION WELLS FT [ ] [061 LEGEND 1. 70-143-11DC4 2. [ ] [32] POTABLE WATER 68 FT [ ] [07] WATERTIGHT [ ] [33] BUILDING FOUNDATIONS 7.5 FT [ ] [081 LEVEL [ ] [34] PROPERTY LINES 100 FT [ ] [09] DEPTH TO LID [ ] [351 OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] [10] AREA [1] 384 [21 SQFT [ ] [36] DRAINFIELD COVER [ ] [11] DISTRIBUTION BOX HEADER X [ ] [371 SHOULDERS [ ] [121 NUMBER OF DRAINLINES 1. 4.00 2. [ ] [381 SLOPES [ ] [131 DRAINLINE SEPARATION [ ] [391 STABILIZATION 04/02/2021 [ ] [14] DRAINLINE SLOPE [ ] [151 DEPTH OF COVER ADDITIONAL INFORMATION [ ] [161 ELEVATION [ ABOVE / BELOW ]BM 10.00 [ ] [401 UNOBSTRUCTED AREA [ ] [171 SYSTEM LOCATION [ ] [41] STORMWATER RUNOFF [ ] [181 DOSING PUMPS [ ] [421 ALARMS [ ] [19] AGGREGATE SIZE [ ] [43] MAINTENANCE AGREEMENT [ ] [201 AGGREGATE EXCESSIVE FINES [ ] [441 BUILDING AREA [ ] [211 AGGREGATE DEPTH [ ] [451 LOCATION CONFORMS WITH SITE PLAN FILL / EXCAVATION MATERIAL [ ] [46] FINAL SITE GRADING [ ] [221 FILL AMOUNT [ ] [47] CONTRACTOR Jeff Nelson (JEFFREY K NEL 1 ] [231 FILL TEXTURE [ ] [481 OTHER INFILTRATOR Quick4 EQ36 (single c [ ] [241 EXCAVATION DEPTH ABANDONMENT [ ] [251 AREA REPLACED [ ] [491 TANK PUMPED t ] [261 REPLACEMENT MATERIAL [ ] [501 TANK CRUSHED & FILLED Comments: Comments are on page 2. / St. Lucie CHD DATE: 01/15/2021 CONSTRUCTION I APPROVED DISAPPROVED ) ' En7'Win ntal Specialist III is gram (ENVIRONMENTAL HEALTH) FINAL SYSTEM [ APPROVED / DISAPPROVED 7: St. Lucie CHID DATE: 04/02/2021 nvi onmental Specialist III B n J Ingram (ENVIRONMENTAL HEALTH) (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1471285 EID2044630 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL Violation Number Comment Comments APPLICATION #:A1P1471285 PERMIT #:56-SF-2044630 DOCUMENT # : FI 1606154 DATE PAID:03/04/2020 FEE PAID.545.00 RECEIPT #:56-PID-4304508 The system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of 300 gpd. New ST, filter, and DF installed. No violations, system ok to cover. Contractor notified by phone. Needs final inspection for mound system, gutters, and final site grading. Final system approved. Contractor, building department, and GC emailed final approval. DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1471235 EID2044630