HomeMy WebLinkAboutEnergy Codex
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Profess ional3egulation - Residential Performance Method
_
v
ua
Project Name: Lot 27 Block 2 Waterstone 2265 AGR
a ffffiilder Name: ADAMS HOMES
Street: 8124 Almalfi Circle
u
® o t )rmit Office:
City, State, Zip: Fort Pierce , FL , 34951
C& c Kermit Number:
Owner:
g = jurisdiction: 661000
Design Location: FL, ST LUCIE_CO_INTL
a 'bounty: St. Lucie (Florida Climate.
Zone 2 )
1. New construction or existing
New (From Plans)
10. Wall Typeol994.2 sqft.)
Insulation Area
2. Single family or multiple family
Detached
a. Concrete Block -; Int Insul, Exterior
R=4.1 1378.30 ftZ
3. Number of units, if multiple family
1
b. Frame - Wood, Exterior
c. Frame - Wood, Adjacent
R=13.0 407.83 ftZ
4. Number of Bedrooms
4
d. N/A
R=13.0 208.00 ftZ
R= ftZ
5. Is this a worst case?
No
11. Ceiling Types (2377.0 sgft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 2277.00 ftZ
6. Conditioned floor area above grade (ftZ)
2277
b. Knee Wall (Vented)
R=19.0 100.00 ftZ
Conditioned floor area below grade (ftZ)
0
c. N/A
R= ftZ
7. Windows(273.9 sqft.) Description
Area
12. Ducts
R ftZ
a. U-Factor: Dbl, U=0.33
154.00 ftZ
a. Sup: Attic, Ret: Main, AH: Main
6 456.2
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33
66.00 ftZ
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
35.0 SEER:16.00
c. U-Factor: Dbl, U=0.55
35.56 ftZ
SHGC: SHGC=0.70
Area Weighted Average Overhang Depth:
5.043 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC:
0.292
a. Electric Heat Pump
34.6 HSPF:8.50
8. Skylights
Area
c. U-Factor:(AVG) N/A
ftZ
15. Hot water systems,
SHGC(AVG): N/A
a. Electric
Cap: 40 gallons
9. Floor Types (2277.0 sgft.)
Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation
R=0.0 2277.00 ftZ
b. Conservation features
b. N/A
R= ftZ
None
c. N/A
R= ftZ
16. Credits
Pstat
Glass/Floor Area: 0.120
Total Proposed Modified Loads: 65.76
PASS
Total Baseline
Loads: 67.04
I hereby certify that the plans a
ations covered
Revie of the plans and
this calculation are in complic
e F on erg
specifications covered by this
s {�
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
d
DATE: n9-n5-2091 Winn
Ken nnny
this building will be inspected for
y„
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
r �,
with the Florida Energy Code.
y'p D {9TFi'
OWNER/AGENT:
-
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
2/5/2021 8:47 AM 7.0.00 - FlaR'es202O FBC 7th Edition (2020) Compliant Software Page 1 of 5
FORM R405-2020 INPUT SUMMARY CHFCKI IST RFPnRT
k
A
J
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 27 Block 2 Waterstone 22 Bedrooms: 4
User Conditioned Area: 2277
Total Stories: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Detached
New (From Plans)
Address Type: Street Address
Lot # 27-2
Block/Subdivision: Waterstone
PlatBook:
Street: 8124 Almalfi Circle
County: St. Lucie
City, State, Zip: Fort Pierce ,
FL , 34951
CLIMATE
/
V Design
Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
2277 20493
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
2277 20493 Yes 5
4 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 206.2 ft 0
2277 ft? ---- 0.35 0 0.65
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Rad Solar SA Emitt Emitt Deck Pitch
Barr Absor. Tested Tested Insul. (deg)
1
Gable or Shed Composition shingles 2546 ftz 570 ftZ Medium
N 0.85 N 0.85 No 0 26.57
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 2277 ftZ N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
2
Under Attic (Vented)
Knee Wall (Vented)
Main 30 Blown
Main 19 Batt
2277 ftZ 0.11 Wood
100 ftz 0.11 Wood
2/5/2021 8:47 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 5
I-VKIVI K4U0-LULU
INFU I SUMMARY GFIEGKLIST REPORT
WALLS
Adjacent
Space
Cavity Width
Height
Sheathing Framing
Solar
Below
1
S
Exterior
Frame - Wood
Main
13 10
2
8
0
81.3 ft2
0
0.23
0.6
0
2
S
Exterior
Concrete Block - Int Insul
Main
4.1 38
7
10
0
385.8 ft2
0
0
0.6
0
3
W
Exterior
Frame - Wood
Main
13 4
6
10
0
45.0 ft2
0
0.23
0.6
0
4
W
Exterior
Concrete Block - Int Insul
Main
4.1 28
6
10
0
285.0 ft2
0
0
0.6
0
5
N
Exterior
Frame - Wood
Main
13 6
9
8
0
54.0 ft2
0
0.23
0.6
0
6
N
Exterior
Concrete Block - Int Insul
Main
4.1 50
3
8
0
402.0 ft2
0
0
0.6
0
7
NE
Exterior
Frame - Wood
Main
13 3
10
10
0
38.3 ft2
0
0.23
0.6
0
8
NE
Exterior
Concrete Block - Int Insul
Main
4.1 0
5
10
0
4.2 ft2
0
0
0.6
0
9
E
Exterior
Frame - Wood
Main
13 18
11
10
0
189.2 ft2
0
0.23
0.6
0
10
E
Exterior
Concrete Block - Int Insul
Main
4.1 37
8
8
0
301.3 ft2
0
0
0.6
0
11
-
Garage
Frame - Wood
Main
13 26
0
8
0
208.0 ft2
0
0.23
0.01
0
DOORS
#
Ornt Door Type
Space
Storms
U-Value
Width
Height
Area
Ft In
Ft In
1
W Insulated
Main
None
.25
3
6 8
20 ft2
2
- Wood
Main
None
.25
2 8
6 8
17.8 ft2
3
N Insulated
Main
None
.25
2 8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
#
Ornt
ID
Frame
Panes
NFRC
U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
S
1
Vinyl
Low-E Double
Yes
0.55
0.7
N
17.8 ft?
23 ft 0 in
0 ft 9 in
Drapes/blinds
None
2
S
2
Vinyl
Low-E Double
Yes
0.33
0.23
N
30.0 ft?
1 ft 0 in
0 ft 10 in
Drapes/blinds
Exterior 5
3
W
3
Vinyl
Low-E Double
Yes
0.33
0.31
N
i
5.0 ft2
7 ft 8 in
0 ft 6 in
None
None
4
W
4
Vinyl
Low-E Double
Yes
0.33
0.31
N
13.3 ft2
7 ft 8 in
2 ft 10 in
None
None
5
W
4
Vinyl
Low-E Double
Yes
0.33
0.21
N
30.0 ft2
1 ft 0 in
0 ft 10 in
Drapes/blinds
Exterior 5
6
W
4
Vinyl
Low-E Double
Yes
0.33
0.21
N
36.0 ft2
1 ft 0 in
2 ft 10 in
Drapes/blinds
Exterior 5
7
N
6
Vinyl
Low-E Double
Yes
0.33
0.23
N
9.0 ft2
1 ft 0 in
0 ft 10 in
Drapes/blinds
Exterior 5
8
N
6
Vinyl
Low-E Double
Yes
0.33
0.23
N
15.0 ft2
1 ft 0 in
0 ft 10 in
Drapes/blinds
Exterior 5
9
NE
7
Vinyl
Low-E Double
Yes
0.33
0.23
N
12.5 ft'
11 ft 0 in
0 ft 4 in
Drapes/blinds
Exterior 5
10
E
9
Vinyl
Low-E Double
Yes
0.55
0.7
N
17.8 ft2'
9 ft 4 in
0 ft 9 in
Drapes/blinds
None
11
E
9
Vinyl
Low-E Double
Yes
0.33
0.23
N
12.5 ft2,
6 ft 8 in
0 ft 4 in
Drapes/blinds
Exterior 5
12
E
9
Vinyl
Low-E Double
Yes
0.33
0.23
N
30.0 ff
9 ft 4 in
0 ft 4 in
Drapes/blinds
Exterior 5
13
E
10
Vinyl
Low-E Double
Yes
0.33
0.23
N
45.0 ft2
1 ft 0 in
0 ft 10 in
Drapes/blinds
Exterior 5
2/5/2021 8:47 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software
Page 3 of 5
FORM R405-2020 INPUT SUMMARY CHFC.KI IST RFPnPT
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
617ft2
617ft2
64ft 9ft 1
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse
Proposed ACH(50)
.0004
2390.9 131.17 246.26 .1324 7
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency 'Capacity Block
Ducts
1
Electric Heat Pump/
Split
Singl HSPF:8.5 34.6 kBtu/hr 1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit/
Split
Singl SEER: 16 35 kBtu/hr cfm 0.75 1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Electric None
Garage
0.94 40 gal 62.3 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None
None
ft2
DUCTS
#
---- Supply ----
Location R-Value Area
---- Return ---- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT QN RLF
HVAC #
Heat Cool
1
Attic 6 456.2 ft
Main
114.05 Default Leakage Main (Default) (Default)
1 1
2/5/2021 8:47 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST RFPnR:T
711
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan
HeatinHJan
Feb
f X Feb
Mar
Mar
Apr
APr
Ma
May
Jun
rj Jun
Jul
Jul
Au
jXjAuSep
rj
Se
Oct
Oct
Nov
NovHDecVentin
Dec
Jan
[ Feb
X Mar
[X] A r
[
Ma
Jun
Jul
Aug
Se
[X] Oct
X Nov
Dec
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 Ibs/s
.ft.
0 ftz
0 ft
0!3
Main
2/5/2021 8:47 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 5
v
FORM R405-2020
11
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE' INDEX* = 98
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2
7. Windows"
Description
a. U-Factor:
Dbl, U=0.33
SHGC:
SHGC=0.23
b. U-Factor:
Dbl, U=0.33
SHGC:
SHGC=0.21
c. U-Factor:
Dbl, U=0.55
SHGC:
SHGC=0.70
d. U-Factor:
other (see details)
SHGC:
other (see details)
Area Weighted Average
Overhang Depth:
Area Weighted Average
SHGC:
8. Skylights
Description
a. U-Factor(AVG):
N/A
SHGC(AVG):
N/A
8124 Almalfi Circle, Fort Pierce, FL, 34951
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1378.30 ft2
b. Frame - Wood, Exterior
R=13.0
407.83 ft2
1
c. Frame - Wood, Adjacent
R=13.0
208.00 ft2
4
d. N/A
R=
ft2
No
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
2277.00 ft2
2277
b. Knee Wall (Vented)
R=19.0
100.00 ft2
Area
c. N/A
R=
ft2
154.00 ft2
12. Ducts, location & insulation level
R ft2
a. Sup: Attic, Ret: Main, AH: Main
6 456.2
66.00 ft2
13. Cooling systems
kBtu/hr
Efficiency
35.56 ft2
a. Central Unit
35.0 SEER:16.00
18.33 ft2
5.043 ft.
0.292
Area
ft2
9. Floor Types Insulation Area
a. Slab -On -Grade Edge Insulation R=0.0 2277.00 ft2
b. N/A R= ft2
c. N/A R= ft2
14. Heating systems
a. Electric Heat Pump
15. Hot water systems
a. Electric
b. Conservation features
None
Credits (Performance method)
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: Date:
Address of New Home: City/FL Zip:
kBtu/hr Efficiency
34.6 HSPF:8.50
Cap: 40 gallons
EF: 0.94
Pstat
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
2/5/2021 8:47 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software