HomeMy WebLinkAboutEnergy CodeA
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 24 Block 1 Waterstone 1720 AGL
Builder Name: ADAMS HOMES
Street: 5356 Lugo Street
Permit Office:
City, State, Zip: Fort Pierce, FL , 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type�1665.3 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1371.10 ftZ
3. Number of units, if multiple family 1
b. Frame - Wood, Adjacent
c. N/A
R=13.0 294.17 ftZ
R= ftZ
4. Number of Bedrooms 3
d. N/A
R= ftZ
5. Is this a worst case? No
11. Ceiling Types (1740.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1720.00 ftz
6. Conditioned floor area above grade (ftZ) 1720
b. Knee Wall (Vented)
R=19.0 20.00 ftZ
Conditioned floor area below grade (ftZ) 0
c. N/A
R= ftZ
7. Windows(183.7 sqft.) Description Area
12. Ducts
R ftZ
a. U-Factor: Dbl, U=0.33 152.99 ftZ
a. Sup: Attic, Ret: Main, AH: Main
6 344
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.55 20.00 ftZ
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.70
a. Central Unit
28.4 SEER:15.00
c. U-Factor: Dbl, U=0.33 10.67 ftZ
1
SHGC: SHang
Area Weighted Average Overhang Depth: 4.890 ft.
.
14Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.286
a. Electric Heat Pump
28.2 HSPF:8.50
8. Skylights Area
c. U-Factor:(AVG) N/A ftZ
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 40 gallons
9. Floor Types (1720.0 sqft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 1720.00 ftZ
b. Conservation features
b. N/A R= ftZ
None
c. N/A R= ftZ
16. Credits
Pstat
Glass/Floor Area: 0.107 Total Proposed Modified Loads: 51.46
PASS
Total Baseline Loads: 52.92
I hereby certify that the plans an tions covered b
Revie f the plans and
� A S`9r�'
this calculation are in complia e t e F orid ay
specifications covered by this
��'' p ,
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY:
Before construction is, completed
f
DATE: (19-10-9(l21 Winn KPnmanv
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida r Code
OWNER/AGENT�� --
BUILDING OFFICIAL:
DATE:
DATE:
'.' - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
t� certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
.envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
I
2/10/2021 12:37 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 5
FORM R405-2020 INPUT RUMMAPV C_I41=rW1 ICT 01=0n0T
PROJECT
Title:
Lot 24 Block 1 Waterstone 17 Bedrooms: 3
Address Type:
Lot Information
Building Type:
User
Conditioned Area: 1720
Lot #
24-1
Owner Name:
Total Stories: 1
Block/Subdivision:
Waterstone
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
ADAMS HOMES
Rotate Angle: 0
Street:
5356 Lugo Street
Permit Office:
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
661000
Whole House Fan: No
City, State, Zip:
Fort Pierce ,
Family Type:
Detached
FL , 34951
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating Design Daily Temp
Design
Location
TMY Site 97.5 % 2.5 %
Winter Summer Degree Days
Moisture Range
FL, ST LUCIE_CO—INTL FL—VERO—BEACH—MUNI 39 90
70 75 299
58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
1720 15480
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
1720 15480 Yes 4
3 1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 171.5 ft 0
1720 ft2 ----
0.26 0 0.74
ROOF
/
Roof Gable Roof
Rad Solar SA Emitt
Emitt Deck Pitch
V #
Type
Materials Area Area Color
Barr Absor. Tested
Tested Insul. (deg)
1
Gable or Shed Composition shingles 1923 ft2 430 ft2 Medium
N 0.85 N 0.85 No 0 26.57
ATTIC
/
V
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 1720 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Knee Wall (Vented)
Main 19 Batt
5 ft2 0.11
Wood
2
Knee Wall (Vented)
Main 19 Batt
15 ft2 0.11
Wood
3
Under Attic (Vented)
Main 30 Blown
1720 ft2 0.11
Wood
2/10/2021 12:37 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 5
FORM R405-2020 INPUT SUMMARY C14FCKI _IST REPORT
ti
WALLS
Adjacent
Space
Cavity Width
Height
Sheathing Framing Solar Below
0
1 S
Exterior
Concrete Block - Int Insul
Main
4.1 32
4
8 5
272.1 ft2
0
0 0.6
0
2 S
Exterior
Concrete Block - Int Insul
Main
4.1 4
5
9 0
39.8 ft2
0
0 0.6
0
3 S
Exterior
Concrete Block - Int Insul
Main
4.1 11
0
8 0
88.0 ft2
0
0 0.6
0
4 E
Exterior
Concrete Block - Int Insul
Main
4.1 5
9
9 0 1
51.8 ft2
0
0 0.6
0
5 E
Exterior
Concrete Block - Int Insul
Main
4.1 12
0
8 0
96.0 ft-
0
0 0.6
0
_ 6 N
Exterior
Concrete Block - Int Insul
Main
4.1 19
9
8 9
172.8 ft2
0
0 0.6
0
7 N
Exterior
Concrete Block - Int Insul
Main
4.1 26
1
9 0
234.8 ft2
0
0 0.6
0
8 N
Exterior
Concrete Block - Int Insul
Main
4.1 13
6
8 0
108.0 ft2
0
0 0.6
0
9 W
Exterior
Concrete Block - Int Insul
Main
4.1 13
9
9 1
124.9 ft2
0
0 0.6
0
10 W
Exterior
Concrete Block - Int Insul
Main
4.1 20
4
9 0
183.0 ft2
0
0 0.6
0
11 -
Garage
Frame - Wood
Main
13 29
5
10 0
294.2 ft2
0
0.23 0.01
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
-
Wood Main
None
.25
2
8
6 8
17.8 ft2
2
E
Insulated Main
None
.25
3
6 8
20 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
# Ornt ID
Frame Panes NFRC
U-Factor SHGC
Imp
Area;
Depth
Separation
Int Shade
Screening
1 S
1
Vinyl Low-E Double
Yes
0.33 0.23
N
16.2 fti
1 ft 4 in
O ft 10 in
None
-
Exterior 5
2 S
1
Vinyl Low-E Double
Yes
0.33 0.23
N
6.9 ft2,
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
3 E
4
Vinyl Low-E Double
Yes
0.33 0.31
N
4.0 ft2l
11 ft 10 in
0 ft 8 in
None
None
4 E
4
Vinyl Low-E Double
Yes
0.33 0.31
N
6.7 ft21
11 ft 10 in
2 ft 9 in
Drapes/blinds
None
5 E
5
Vinyl Low-E Double
Yes
0.33 0.23
N
32.4 ft'
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
6 N
6
Vinyl Low-E Double
Yes
0.33 0.23
N
6.9 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
7 N
6
Vinyl Low-E Double
Yes
0.33 0.23
N
16.2 fti
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
8 N
7
Vinyl Low-E Double
Yes
0.33 0.23
N
9.8 ft2;
1 ft 4 in
0 ft 10 in
None
Exterior 5
9 W
9
Vinyl Low-E Double
Yes
0.33 0.23
N
16.2 ft2.
11 ft 8 in
0 ft 10 in
None
Exterior 5
10 W
9
Vinyl Low-E Double
Yes
0.33 0.23
N
16.2 ft21
11 ft 8 in
0 ft 10 in
None
Exterior 5
11 W
10
Metal Low-E Double
Yes
0.55 0.7
N
20.0 ft2�
11 ft 8 in
1 ft 0 in
Drapes/blinds
None
12 W
10
Vinyl Low-E Double
Yes
0.33 0.23
N
32.4 ft2l
1 ft 4 in
0 ft 10 in
None
Exterior 5
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
610ft2 610ft2
56ft
8ft
1
2/10/2021 12:37 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5
w
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.0004
1806 99.08 186.02 .1324
7
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency Capacity
Block
Ducts
1 Electric Heat Pump/
Split
Sing] HSPF:8.5 28.2 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit/
Split
Singl SEER: 15 28.4 kBtu/hr cfm
0.75 1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use SetPnt
Conservation
1 Electric None
Garage
0.94 40 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft2
DUCTS
---- Supply ----
V # Location R-Value Area
---- Return ---- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT
QN RLF
HVAC #
Heat Cool
1 Attic 6 344 ft2
Main
86 ft2 Default Leakage Main (Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Coolin Jan Feb Mar
Heating X Jan X Feb f X� Mar
Ventin [ Jan [ Feb X Mar
Ceiling Fans:
Se
APrMayJun Jul AuSeP
Apr Ma rj Junrl
Jul rj
Au rl
[ A r [ Ma Jun JulAug Se [X]
Oct Nov
Oct Nov
Oct HX Nov
Dec
Dec
H Dec
2/10/2021 12:37 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78,
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68 ;.
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture
Fraction
Space
Default 8 Ibs/s
.ft.
0 ftz
0 ft
0.3
Main
2/10/2021 12:37 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 5
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE, INDEX* = 97
The lower the EnergyPerformance Index, the more efficient the home.
5356 Lugo Street, Fort Pierce, FL, 349,51
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1371.10 ftz
b. Frame - Wood, Adjacent
R=13.0
294.17 ftz
3. Number of units, if multiple family
1
c. N/A
R=
ftz
4. Number of Bedrooms
3
d. N/A
R=
ftz
5. Is this a worst case?
No
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
1720.00 ftz
6. Conditioned floor area (ftz)
1720
b. Knee Wall (Vented)
R=19.0
20.00 ftz
7. Windows** Description
Area
_
R
2
a. U-Factor: Dbl, U=0.33
152.99 ftZ
12cDucts, location &insulation level
R ftz
a. Sup: Attic, Ret: Main, AH: Main
6 344
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.55
20.00 ftz
SHGC: SHGC=0.70
13. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: Dbl, U=0.33
10.67 ftz
a. Central Unit
28.4 SEER:15.00
SHGC: SHGC=0.31
d. U-Factor: N/A
ftz
SHGC:
14. Heating systems
kBtu/hr
Efficiency
Area Weighted Average Overhang Depth:
4.890 ft.
a. Electric Heat Pump
28.2
HSPF:8.50
Area Weighted Average SHGC:
0.286
8. Skylights Description
Area
15. Hot water systems
a. U-Factor(AVG): N/A
ft z
a. Electric
Cap:
40 gallons
SHGC(AVG): N/A
EF:0.94
b. Conservation features
9. Floor Types
Insulation
Area
None
a. Slab -On -Grade Edge Insulation
R=0.0
1720.00 ftz
Credits (Performance method)
Pstat
b. N/A
R=
ftZ
c. N/A
R=
ftz
certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code comolientfeatures.
Builder Signature� Date:
Address of New Home:
City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
2/10/2021 12:38 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1