Loading...
HomeMy WebLinkAboutEnergy CodeA FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 24 Block 1 Waterstone 1720 AGL Builder Name: ADAMS HOMES Street: 5356 Lugo Street Permit Office: City, State, Zip: Fort Pierce, FL , 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type�1665.3 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1371.10 ftZ 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent c. N/A R=13.0 294.17 ftZ R= ftZ 4. Number of Bedrooms 3 d. N/A R= ftZ 5. Is this a worst case? No 11. Ceiling Types (1740.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1720.00 ftz 6. Conditioned floor area above grade (ftZ) 1720 b. Knee Wall (Vented) R=19.0 20.00 ftZ Conditioned floor area below grade (ftZ) 0 c. N/A R= ftZ 7. Windows(183.7 sqft.) Description Area 12. Ducts R ftZ a. U-Factor: Dbl, U=0.33 152.99 ftZ a. Sup: Attic, Ret: Main, AH: Main 6 344 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.55 20.00 ftZ 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.70 a. Central Unit 28.4 SEER:15.00 c. U-Factor: Dbl, U=0.33 10.67 ftZ 1 SHGC: SHang Area Weighted Average Overhang Depth: 4.890 ft. . 14Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.286 a. Electric Heat Pump 28.2 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) N/A ftZ 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 40 gallons 9. Floor Types (1720.0 sqft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 1720.00 ftZ b. Conservation features b. N/A R= ftZ None c. N/A R= ftZ 16. Credits Pstat Glass/Floor Area: 0.107 Total Proposed Modified Loads: 51.46 PASS Total Baseline Loads: 52.92 I hereby certify that the plans an tions covered b Revie f the plans and � A S`9r�' this calculation are in complia e t e F orid ay specifications covered by this ��'' p , Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is, completed f DATE: (19-10-9(l21 Winn KPnmanv this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida r Code OWNER/AGENT�� -- BUILDING OFFICIAL: DATE: DATE: '.' - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as t� certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an .envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). I 2/10/2021 12:37 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 5 FORM R405-2020 INPUT RUMMAPV C_I41=rW1 ICT 01=0n0T PROJECT Title: Lot 24 Block 1 Waterstone 17 Bedrooms: 3 Address Type: Lot Information Building Type: User Conditioned Area: 1720 Lot # 24-1 Owner Name: Total Stories: 1 Block/Subdivision: Waterstone # of Units: 1 Worst Case: No PlatBook: Builder Name: ADAMS HOMES Rotate Angle: 0 Street: 5356 Lugo Street Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: 661000 Whole House Fan: No City, State, Zip: Fort Pierce , Family Type: Detached FL , 34951 New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST LUCIE_CO—INTL FL—VERO—BEACH—MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 1720 15480 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1720 15480 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 171.5 ft 0 1720 ft2 ---- 0.26 0 0.74 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1923 ft2 430 ft2 Medium N 0.85 N 0.85 No 0 26.57 ATTIC / V Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1720 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Knee Wall (Vented) Main 19 Batt 5 ft2 0.11 Wood 2 Knee Wall (Vented) Main 19 Batt 15 ft2 0.11 Wood 3 Under Attic (Vented) Main 30 Blown 1720 ft2 0.11 Wood 2/10/2021 12:37 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 5 FORM R405-2020 INPUT SUMMARY C14FCKI _IST REPORT ti WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 1 S Exterior Concrete Block - Int Insul Main 4.1 32 4 8 5 272.1 ft2 0 0 0.6 0 2 S Exterior Concrete Block - Int Insul Main 4.1 4 5 9 0 39.8 ft2 0 0 0.6 0 3 S Exterior Concrete Block - Int Insul Main 4.1 11 0 8 0 88.0 ft2 0 0 0.6 0 4 E Exterior Concrete Block - Int Insul Main 4.1 5 9 9 0 1 51.8 ft2 0 0 0.6 0 5 E Exterior Concrete Block - Int Insul Main 4.1 12 0 8 0 96.0 ft- 0 0 0.6 0 _ 6 N Exterior Concrete Block - Int Insul Main 4.1 19 9 8 9 172.8 ft2 0 0 0.6 0 7 N Exterior Concrete Block - Int Insul Main 4.1 26 1 9 0 234.8 ft2 0 0 0.6 0 8 N Exterior Concrete Block - Int Insul Main 4.1 13 6 8 0 108.0 ft2 0 0 0.6 0 9 W Exterior Concrete Block - Int Insul Main 4.1 13 9 9 1 124.9 ft2 0 0 0.6 0 10 W Exterior Concrete Block - Int Insul Main 4.1 20 4 9 0 183.0 ft2 0 0 0.6 0 11 - Garage Frame - Wood Main 13 29 5 10 0 294.2 ft2 0 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 - Wood Main None .25 2 8 6 8 17.8 ft2 2 E Insulated Main None .25 3 6 8 20 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area; Depth Separation Int Shade Screening 1 S 1 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 fti 1 ft 4 in O ft 10 in None - Exterior 5 2 S 1 Vinyl Low-E Double Yes 0.33 0.23 N 6.9 ft2, 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 3 E 4 Vinyl Low-E Double Yes 0.33 0.31 N 4.0 ft2l 11 ft 10 in 0 ft 8 in None None 4 E 4 Vinyl Low-E Double Yes 0.33 0.31 N 6.7 ft21 11 ft 10 in 2 ft 9 in Drapes/blinds None 5 E 5 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft' 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 6 N 6 Vinyl Low-E Double Yes 0.33 0.23 N 6.9 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 7 N 6 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 fti 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 8 N 7 Vinyl Low-E Double Yes 0.33 0.23 N 9.8 ft2; 1 ft 4 in 0 ft 10 in None Exterior 5 9 W 9 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft2. 11 ft 8 in 0 ft 10 in None Exterior 5 10 W 9 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft21 11 ft 8 in 0 ft 10 in None Exterior 5 11 W 10 Metal Low-E Double Yes 0.55 0.7 N 20.0 ft2� 11 ft 8 in 1 ft 0 in Drapes/blinds None 12 W 10 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2l 1 ft 4 in 0 ft 10 in None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 610ft2 610ft2 56ft 8ft 1 2/10/2021 12:37 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5 w FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .0004 1806 99.08 186.02 .1324 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Sing] HSPF:8.5 28.2 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 15 28.4 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 DUCTS ---- Supply ---- V # Location R-Value Area ---- Return ---- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 344 ft2 Main 86 ft2 Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Coolin Jan Feb Mar Heating X Jan X Feb f X� Mar Ventin [ Jan [ Feb X Mar Ceiling Fans: Se APrMayJun Jul AuSeP Apr Ma rj Junrl Jul rj Au rl [ A r [ Ma Jun JulAug Se [X] Oct Nov Oct Nov Oct HX Nov Dec Dec H Dec 2/10/2021 12:37 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78, 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 ;. 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ftz 0 ft 0.3 Main 2/10/2021 12:37 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 5 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE, INDEX* = 97 The lower the EnergyPerformance Index, the more efficient the home. 5356 Lugo Street, Fort Pierce, FL, 349,51 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1371.10 ftz b. Frame - Wood, Adjacent R=13.0 294.17 ftz 3. Number of units, if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms 3 d. N/A R= ftz 5. Is this a worst case? No 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 1720.00 ftz 6. Conditioned floor area (ftz) 1720 b. Knee Wall (Vented) R=19.0 20.00 ftz 7. Windows** Description Area _ R 2 a. U-Factor: Dbl, U=0.33 152.99 ftZ 12cDucts, location &insulation level R ftz a. Sup: Attic, Ret: Main, AH: Main 6 344 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.55 20.00 ftz SHGC: SHGC=0.70 13. Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl, U=0.33 10.67 ftz a. Central Unit 28.4 SEER:15.00 SHGC: SHGC=0.31 d. U-Factor: N/A ftz SHGC: 14. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 4.890 ft. a. Electric Heat Pump 28.2 HSPF:8.50 Area Weighted Average SHGC: 0.286 8. Skylights Description Area 15. Hot water systems a. U-Factor(AVG): N/A ft z a. Electric Cap: 40 gallons SHGC(AVG): N/A EF:0.94 b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 1720.00 ftz Credits (Performance method) Pstat b. N/A R= ftZ c. N/A R= ftz certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code comolientfeatures. Builder Signature� Date: Address of New Home: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 2/10/2021 12:38 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1