HomeMy WebLinkAboutEnergy CodeFORM ','h405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation"- Residential Performance Method
Project Name: Lot 15 Block 2 Waterstone 2508 AGR
Builder Name: ADAMS HOMES
Street: 8201 Amalfi Circle
Permit Office:
City, State, Zip: Fort Pierce , FL, 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST LUCIE_CO_INTL
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New,(From Plans)
10. Wall Type41944.0 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1672.00 ft2
b. Frame - Wood, Adjacent
R=13.0 272.00 ft2
3. Number of units, if multiple family 1
c. N/A .
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
11. ,Ceiling Types (2616.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 2516.00 ft2
6. Conditioned floor area above grade (ft2) 2516
b. Knee Wall (Vented)
R=19.0 100.00 ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(308.9 sqft.) Description Area
12. Ducts
a. Sup: Attic, Ret: Main, AH: Main
R ft2
6 503.2
a. U-Factor: Dbl, U=0.33 166.06 ft?
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.55 51.11 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.70
a. Central Unit
42.0 SEER:15.00
c. U-Factor. Dbl, U=0.33 38.54 ft2
SHGC: SHGC=0.21
Area Weighted Average Overhang Depth: 6.539 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.314
a. Electric Heat Pump
42.0 HSPF:8.50
8. Skylights Area
c. U-Factor(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 40 gallons
9. Floor Types (2516.0 sqft.) Insulation Area
EF:0.940
a. Slab -On -Grade Edge Insulation R=0:0 2516.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
Pstat
Glass/Floor Area: 0.123 Total Proposed Modified Loads: 70.15
PASS
Total Baseline Loads: 70.44
I hereby certify that the plans s ications covered
Revi . of the plans and
this calculation are in compl' ori
specifications covered by this
' ` Off,
_ _ergy
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
.�.
DATE: n.3-94-9n21 Winn Kenmany
this building will be inspected for
compliance with Section 553.908'�
I hereby certify that this building, as designed, is in compliance
the Florida Energ
Florida Statutes.
"
6'OD+ag
with
OWNER/AGEN
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory:sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 6.50 ACH50 (R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.050 Qn for whole house.
3/24/2021 2:28 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 15 Block 2 Waterstone 25 Bedrooms: 4
User Conditioned Area: 2516
Total Stories: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Detached
New (From Plans)
Address Type: Street Address
Lot # 15-2
Block/Subdivision: Waterstone
PlatBook:
Street: 8201 Amalfi Circle
County: St. Lucie
City, State, Zip: Fort Pierce ,
FL, 34951
CLIMATE
/
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST LUCIE_CO_INTL FL VERO_BEACH_MUNI 39 90
70 75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
2516 20128
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
2516 20128 Yes 5
4 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 208.9 ft 0
2516 ftz ___ 0.44 0 0.56
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Rad Solar SA Emitt Emitt Deck Pitch
Barr Absor. Tested Tested Insul. (deg)
1
Gable or Shed Composition shingles 2813 ftz 630 ftz Medium
N 0.85 N 0.85 No 0 26.57
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 2516 ftz N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
2
Under Attic (Vented)
Knee Wall (Vented)
Main 30 Blown
Main 19 Batt
2516 ftz 0.11 Wood
100 ftZ 0.11 Wood
3/24/2021 2:28 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing Solar
Below
Space
1 W
Exterior
Concrete Block - Inf lnsul
Main
4.1
17
6
8 0
140.0 ft2
0
0 0.6
0
_ 2 E
Exterior
Concrete Block- Int Insul
Main
4.1
34
6
8 0
276.0 ft2
0
0 0.6
0
3 S
Exterior
Concrete Block - Int Insul
Main
4.1
42
6
8 0
340.0 ft2
0
0 0.6
0
_ 4 SW
Exterior
Concrete Block - Int In, sul
Main
4.1
5
0
8 0
40.0 ft2
0
0 0.6
0
5 W
Exterior
Concrete Block - Int Insul
Main
4.1
20
0
8 0
160.0 ft2
0
0 0.6
0
6 -
Garage
Frame - Wood
Main
13
34
0
8 0
272.0 ft2
0
0.23 0.01
0
_ 7 W
Exterior
Concrete Block - Int Insul
Main
4.1
18
0
8 0
144.0 ft2
0
0 0.6
0
8 S
Exterior
Concrete Block - Int Insul
Main
4.1
8
6
8 0
68.0 ft2
0
0 0.6
0
9 S
Exterior
Concrete Block- Int Insul
i
Main
4.1
6
0
8 0
48.0 ft2
0
0 0.6
0
10 N
Exterior
Concrete Block - Int Insul
Main
4.1
57
8
456.0 ft2
0 0.6
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
E
Insulated
Main
None
.25
3
6 8
20 ft2
2
-
Wood
Main
None
.25
2
8
6 8 17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V/ # Omt ID
Frame Panes NFRC
U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1 S
8
Vinyl Low-E Double
Yes
0.55
0.7
N
15.6 ft2
25 ft 0 in 0 ft 10 in
Drapes/blinds
None
2 N
10
Vinyl Low-E Double
Yes
0.33
0.23
N
32.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
3 E
2
Vinyl Low-E Double
Yes
0.33
0.31
N
7.5 ft2
13 ft 0 in
0 ft 6 in
None
None
4 E
2
Vinyl Low-E Double
Yes
0.33
0.31
N
13.3 ft2
13 ft 0 in
2 ft 10 in
None
None
5 E
2
Vinyl Low-E Double
Yes
0.35
0.26
N
32.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
6 E
2
Vinyl Low-E Double
Yes
0.33
0.21
N
38.5 ft2
1 ft 4 in
2 ft 0 in
Drapes/blinds
None
7 N
10
Vinyl Low-E Double j
Yes
0.55
0.7
N
17.8 ft2
25 ft 0 in
0 ft 10 in
Drapes/blinds
None
8 S
3
Vinyl Low-E Double
Yes
0.33
0.23
N
9.8 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
9 S
3
Vinyl Low-E Double
Yes
0.33
0.23
N
16.2 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
10 SW 4
Vinyl Low-E Double
Yes
0.33
0.23
N
12.5 ft2
7 ft 2 in
0 ft 4 in
Drapes/blinds
None
11 W
5
Vinyl Low-E Double
Yes
0.55
0.7
N
17.8 ft2
9 ft 10 in
0 ft 10 in
Drapes/blinds
None
12 W
5
Vinyl Low-E Double
Yes
0.33
0.23
N
16.7 ft2
7 ft 2 in
0 ft 4 in
Drapes/blinds
None
13 W
7
Vinyl Low-E Double
Yes
0.33
0.23
N
30.0 ft2
9 ft 10 in
0 ft 4 in
Drapes/blinds
None
14 W
5
Vinyl Low-E Double
Yes
0.33
0.23
N
48.6 ft2
1 ft 4 in
1 ft 2 in
Drapes/blinds
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
555 ft2 555 ft2
64 ft
8 ft
1
3/24/2021 2:28 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
INFILTRATION
# Scope Method
P
!SLA
CFM 50 ELA E LA ACH ACH 50
4
1 Wholehouse Proposed ACH(50)
00033
2180.5 119.63 224.59 .1173
6.5
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency Capacity
Block
Ducts
1 Electric Heat Pump/
Split
Singl HSPF:8.5 42 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit/
Split
Singl SEER: 15 42 kBtu/hr cfm
0.75 1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use SetPnt
Conservation
1 Electric None
Garage
0.94 40 gal 62.3 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cart # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft2
DUCTS
-- Supply---
V # Location R-Value Area
--- Return-- Air CFM 25 CFM25
Location Area Leakage Type Handier TOT OUT
QN RLF
HVAC #
Heat Cool
1 Attic 6 503.2 ft
Main
125.8 ft Proposed Qn Main -- cfm 125.8 cfm 0.05 0.60
1 1
TEMPERATURES
Programable Thermostat: Y
Cooling an Feb Mar
Heating Jan Feb Mar
Ventin Jan Feb X Mar
Ceiling Fans:
Jun Jul rl Auge
E Apr [ May Jun Jul AuSep
A r r Ma rj
[X] A r [[[ ]]] Ma Jun Jul Aug Se [x]
Oct Nov
Oct Nov
Oct N Nov
Dec
Dec
H Dec
3/24/2021 2:28 PM
EnergyGauge® USA 7
0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software
Page 4 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 Ibs/s
.ft.
0 ft2
0 ft
0.3
Main
3/24/2021 2:28 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 5
FORM, R405-2020
ENERGY PERFORMANCE
LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
r
The lower the EnergyPerformance
Index, the more efficient the home.
- 8261 Amalfi Circle,
Fort Pierce, FL, 34951
1. New construction or existing New' (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1672.00 ftZ
b. Frame - Wood, Adjacent
R=13.0
272.00 ftZ
3. Number of units, if multiple family 1
c. N/A
R=
ftz
4. Number of Bedrooms 4 j
d: N/A
R=
ftZ
5. Is this a worst case? No
11.. Ceiling Type and insulation. level
Insulation
Area
a. Under Attic (Vented)
R=30.0
2516.00 ftZ
6. Conditioned floor area (ftZ) 2516
b. Knee Wall (Vented)
R=19.0
100.00 ftZ
7. Windows** Description Area
c. N/A
R=
ftz
a. U-Factor. Dbt, U=0.33 - 166.06 ftZ
12. Ducts, location &-insulation level
R ftZ
a. Sup: Attic,, Ret: Main, AH:: Main
6 503.2
SHGC: SHGC=0.23
b. U-Factor:. Dbl, U=0.55
51.11 ftZ
SHGC: SHGC=0.70
13. Cooling systems
kBtu/hr -Efficiency
c. U-Factor: Dbl,'U=0.33 38.54 ftZ
a. Central Unit
42.0 SEER:15.00
SHGC: SHGC=0.21
d. U-Factor: other (see details) 53.21 ftZ
SHGC: other (see details) �
14. Heating systems
kBtulhr
Efficiency
Area Weighted Average Overhang Depth: 6.539 ft.
a. Electric Heat Pump
42.0
HSPF:8.50
Area Weighted Average SHGC: 0.314
8. Skylights Description Area
15. Hot watersystems
Cap:
40 gallons
a. U-Factor(AVG): N/A {jZ
a. Electric
_
SHGC(AVG): N/A .
EF: 0.94
b., Conservation features
9: Floor Types Insulation Area
None
a. Slab -On -Grade Edge Insulation R=0.0 2516.00 ftZ
Credits (Performance method)
Pstat
b. N/A R= ftZ
c. N/A R= ftZ
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card'will be: completed
based on installed Code compliant features.
Builder Signatu
Address of New Home:
Date:
City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy. Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of fhe Florida Building Code, Energy Conservation, if not -DEFAULT.
3/24/2021 2:28 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1