Loading...
HomeMy WebLinkAboutEnergy CodeFORM ','h405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation"- Residential Performance Method Project Name: Lot 15 Block 2 Waterstone 2508 AGR Builder Name: ADAMS HOMES Street: 8201 Amalfi Circle Permit Office: City, State, Zip: Fort Pierce , FL, 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New,(From Plans) 10. Wall Type41944.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1672.00 ft2 b. Frame - Wood, Adjacent R=13.0 272.00 ft2 3. Number of units, if multiple family 1 c. N/A . R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 11. ,Ceiling Types (2616.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 2516.00 ft2 6. Conditioned floor area above grade (ft2) 2516 b. Knee Wall (Vented) R=19.0 100.00 ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(308.9 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Main, AH: Main R ft2 6 503.2 a. U-Factor: Dbl, U=0.33 166.06 ft? SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.55 51.11 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.70 a. Central Unit 42.0 SEER:15.00 c. U-Factor. Dbl, U=0.33 38.54 ft2 SHGC: SHGC=0.21 Area Weighted Average Overhang Depth: 6.539 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.314 a. Electric Heat Pump 42.0 HSPF:8.50 8. Skylights Area c. U-Factor(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 40 gallons 9. Floor Types (2516.0 sqft.) Insulation Area EF:0.940 a. Slab -On -Grade Edge Insulation R=0:0 2516.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits Pstat Glass/Floor Area: 0.123 Total Proposed Modified Loads: 70.15 PASS Total Baseline Loads: 70.44 I hereby certify that the plans s ications covered Revi . of the plans and this calculation are in compl' ori specifications covered by this ' ` Off, _ _ergy Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed .�. DATE: n.3-94-9n21 Winn Kenmany this building will be inspected for compliance with Section 553.908'� I hereby certify that this building, as designed, is in compliance the Florida Energ Florida Statutes. " 6'OD+ag with OWNER/AGEN BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory:sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.50 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.050 Qn for whole house. 3/24/2021 2:28 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Lot 15 Block 2 Waterstone 25 Bedrooms: 4 User Conditioned Area: 2516 Total Stories: 1 1 Worst Case: No ADAMS HOMES Rotate Angle: 0 Cross Ventilation: No 661000 Whole House Fan: No Detached New (From Plans) Address Type: Street Address Lot # 15-2 Block/Subdivision: Waterstone PlatBook: Street: 8201 Amalfi Circle County: St. Lucie City, State, Zip: Fort Pierce , FL, 34951 CLIMATE / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST LUCIE_CO_INTL FL VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 2516 20128 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2516 20128 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 208.9 ft 0 2516 ftz ___ 0.44 0 0.56 ROOF / V # Type Roof Gable Roof Materials Area Area Color Rad Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 2813 ftz 630 ftz Medium N 0.85 N 0.85 No 0 26.57 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2516 ftz N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 2 Under Attic (Vented) Knee Wall (Vented) Main 30 Blown Main 19 Batt 2516 ftz 0.11 Wood 100 ftZ 0.11 Wood 3/24/2021 2:28 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 W Exterior Concrete Block - Inf lnsul Main 4.1 17 6 8 0 140.0 ft2 0 0 0.6 0 _ 2 E Exterior Concrete Block- Int Insul Main 4.1 34 6 8 0 276.0 ft2 0 0 0.6 0 3 S Exterior Concrete Block - Int Insul Main 4.1 42 6 8 0 340.0 ft2 0 0 0.6 0 _ 4 SW Exterior Concrete Block - Int In, sul Main 4.1 5 0 8 0 40.0 ft2 0 0 0.6 0 5 W Exterior Concrete Block - Int Insul Main 4.1 20 0 8 0 160.0 ft2 0 0 0.6 0 6 - Garage Frame - Wood Main 13 34 0 8 0 272.0 ft2 0 0.23 0.01 0 _ 7 W Exterior Concrete Block - Int Insul Main 4.1 18 0 8 0 144.0 ft2 0 0 0.6 0 8 S Exterior Concrete Block - Int Insul Main 4.1 8 6 8 0 68.0 ft2 0 0 0.6 0 9 S Exterior Concrete Block- Int Insul i Main 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 10 N Exterior Concrete Block - Int Insul Main 4.1 57 8 456.0 ft2 0 0.6 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Insulated Main None .25 3 6 8 20 ft2 2 - Wood Main None .25 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V/ # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 8 Vinyl Low-E Double Yes 0.55 0.7 N 15.6 ft2 25 ft 0 in 0 ft 10 in Drapes/blinds None 2 N 10 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds None 3 E 2 Vinyl Low-E Double Yes 0.33 0.31 N 7.5 ft2 13 ft 0 in 0 ft 6 in None None 4 E 2 Vinyl Low-E Double Yes 0.33 0.31 N 13.3 ft2 13 ft 0 in 2 ft 10 in None None 5 E 2 Vinyl Low-E Double Yes 0.35 0.26 N 32.4 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds None 6 E 2 Vinyl Low-E Double Yes 0.33 0.21 N 38.5 ft2 1 ft 4 in 2 ft 0 in Drapes/blinds None 7 N 10 Vinyl Low-E Double j Yes 0.55 0.7 N 17.8 ft2 25 ft 0 in 0 ft 10 in Drapes/blinds None 8 S 3 Vinyl Low-E Double Yes 0.33 0.23 N 9.8 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds None 9 S 3 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds None 10 SW 4 Vinyl Low-E Double Yes 0.33 0.23 N 12.5 ft2 7 ft 2 in 0 ft 4 in Drapes/blinds None 11 W 5 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 9 ft 10 in 0 ft 10 in Drapes/blinds None 12 W 5 Vinyl Low-E Double Yes 0.33 0.23 N 16.7 ft2 7 ft 2 in 0 ft 4 in Drapes/blinds None 13 W 7 Vinyl Low-E Double Yes 0.33 0.23 N 30.0 ft2 9 ft 10 in 0 ft 4 in Drapes/blinds None 14 W 5 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 1 ft 4 in 1 ft 2 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 555 ft2 555 ft2 64 ft 8 ft 1 3/24/2021 2:28 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method P !SLA CFM 50 ELA E LA ACH ACH 50 4 1 Wholehouse Proposed ACH(50) 00033 2180.5 119.63 224.59 .1173 6.5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 42 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 15 42 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 DUCTS -- Supply--- V # Location R-Value Area --- Return-- Air CFM 25 CFM25 Location Area Leakage Type Handier TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 503.2 ft Main 125.8 ft Proposed Qn Main -- cfm 125.8 cfm 0.05 0.60 1 1 TEMPERATURES Programable Thermostat: Y Cooling an Feb Mar Heating Jan Feb Mar Ventin Jan Feb X Mar Ceiling Fans: Jun Jul rl Auge E Apr [ May Jun Jul AuSep A r r Ma rj [X] A r [[[ ]]] Ma Jun Jul Aug Se [x] Oct Nov Oct Nov Oct N Nov Dec Dec H Dec 3/24/2021 2:28 PM EnergyGauge® USA 7 0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft2 0 ft 0.3 Main 3/24/2021 2:28 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 5 FORM, R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 r The lower the EnergyPerformance Index, the more efficient the home. - 8261 Amalfi Circle, Fort Pierce, FL, 34951 1. New construction or existing New' (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1672.00 ftZ b. Frame - Wood, Adjacent R=13.0 272.00 ftZ 3. Number of units, if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms 4 j d: N/A R= ftZ 5. Is this a worst case? No 11.. Ceiling Type and insulation. level Insulation Area a. Under Attic (Vented) R=30.0 2516.00 ftZ 6. Conditioned floor area (ftZ) 2516 b. Knee Wall (Vented) R=19.0 100.00 ftZ 7. Windows** Description Area c. N/A R= ftz a. U-Factor. Dbt, U=0.33 - 166.06 ftZ 12. Ducts, location &-insulation level R ftZ a. Sup: Attic,, Ret: Main, AH:: Main 6 503.2 SHGC: SHGC=0.23 b. U-Factor:. Dbl, U=0.55 51.11 ftZ SHGC: SHGC=0.70 13. Cooling systems kBtu/hr -Efficiency c. U-Factor: Dbl,'U=0.33 38.54 ftZ a. Central Unit 42.0 SEER:15.00 SHGC: SHGC=0.21 d. U-Factor: other (see details) 53.21 ftZ SHGC: other (see details) � 14. Heating systems kBtulhr Efficiency Area Weighted Average Overhang Depth: 6.539 ft. a. Electric Heat Pump 42.0 HSPF:8.50 Area Weighted Average SHGC: 0.314 8. Skylights Description Area 15. Hot watersystems Cap: 40 gallons a. U-Factor(AVG): N/A {jZ a. Electric _ SHGC(AVG): N/A . EF: 0.94 b., Conservation features 9: Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 2516.00 ftZ Credits (Performance method) Pstat b. N/A R= ftZ c. N/A R= ftZ I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card'will be: completed based on installed Code compliant features. Builder Signatu Address of New Home: Date: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy. Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of fhe Florida Building Code, Energy Conservation, if not -DEFAULT. 3/24/2021 2:28 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1