HomeMy WebLinkAboutEnergy Code''FORMTR405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional
Regulation - Residential Performance Method
Project Name: Lot 26 Block 1 Waterstone 1820 CGR
Builder Name: ADAMS HOMES
Street: 5348 Lugo Street
Permit Office:
City, State, Zip: Fort Pierce , FL , 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
1
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall TypeV120.0 sgft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1850.00 ftz
3. Number of units, if multiple family 1
b. Frame - Wood; Adjacent
c. N/A
R=13.0 270.00 ftz
R= ftz
4. Number of Bedrooms 4
d. N/A
R= ftz
5. Is this a worst case? No
11. Ceiling Types (1900.0 sgft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1820.00 ftz
6. Conditioned floor area above grade (ftz) 1820
b. Knee Wall (Vented)
R=19.0 80.00 ftz
Conditioned floor area below grade (ftz) 0
c. N/A
R= ftz
7. Windows(239.3 sgft.) Description Area
12. Ducts
R ftz
a. U-Factor: Dbl, U=0.33 168.74 ftz
a. Sup: Attic, Ret:, Main, AH: Main
6 364
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 32.38 ftz
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
35.0 SEER:16.00
c. U-Factor: Dbl, U=0.33 20.42 ftz
SHGC: SHGC=0.31
Area Weighted Average Overhang Depth: 4.067 ft.
14. Heating systemsi
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.269
a. Electric Heat Pump
34.6 HSPF:8.50
8. Skylights Area
c. U-Factor:(AVG) N/A ftz
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 40 gallons
9. Floor Types (1820.0 sgft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 1820.00 ftz
b. Conservation features
b. N/A R= ftz
None
c. N/A R= ftz
16. Credits
Pstat
Glass/Floor Area: 0.131 Total Proposed Modified Loads: 59.78
PASS
Total Baseline
Loads: 64.83
I hereby certify that the plans ications covered:
e w of the plans and%6E
this calculation are in comp ' I the Flori ergy
specifications covered by this
10
Code.
calculation indicates compliance
�nt� �0
with the Florida Energy Code.
y `r
PREPARED BY:
Before construction is
DATE: 0 -Oq-?O 1 Winn Kenmany
completed
this building will be inspected for
compliance with Section 553.908
*.
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida EnergCode.C'®�
OWNER/AGENT: t
BUILDING OFFICIAL:
DATE:
DATE:
�'- Compliance requires certification by the air handier unit manufacturer that the Handler
air enclosure
qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation. Inspection
Checklist in accordance with R402.4.1.1 and this project requires an
- envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
2/9/2021 3:51 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4
FORM RA05-2020
INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Lot 26 Block 1 Waterstone 18 Bedrooms: 4
Address Type:
Street Address
Building Type:
User
Conditioned Area: 1820
Lot #
26-1
Owner Name:
Total Stories: 1
Block/Subdivision:
Waterstone
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
ADAMS HOMES
Rotate Angle: 0
Street:
5348 Lugo Street
Permit Office:
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
661000
Whole House Fan: No
City, State, Zip:
Fort Pierce ,
Family Type:
Detached
FL, 34951
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating
Design Daily Temp
Design Location
TMY Site 97.5 % 2.5 %
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL VERO_BEACH_MUNI 39 90
70 75 299
58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
1820 18200
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
1820 18200 Yes 5
4 1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 33 ft 0
1820 ft2 ----
0.42 0 0.58
ROOF
/
Roof Gable Roof
Rad Solar SA Emitt
Emitt Deck Pitch
V #
Type
Materials Area Area Color
Barr Absor. Tested
Tested Insul. (deg)
1
Gable or Shed Composition shingles 2035 ft2 456 ft2 Medium
N 0.85 N 0.85 No 0 26.57
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 1820 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
1820 ft2 0.11
Wood
2
Knee Wall (Vented)
Main 19 Batt
80 ft2 0.11
Wood
2/9/2021 3:51 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
�
Space
Cavity Width
-
Height
Sheathing Framing
Solar Below
o
1
S
Exterior
Concrete Block - Int Insul Main
4.1 59 0
10 0'
590.0 ft2
0
0
0.6
0
2
E
Exterior
Concrete Block - Int Insul Main
4.1 20 0
10 0
200.0 ft2
0
0
0.6
0
3
N
Exterior
Concrete Block - Int Insul Main
4.1 66 0
10 01
660.0 ft2
0
0
0.6
0
4
W
Exterior
Concrete Block - Int Insul Main
4.1 40 0
10 01
400.0 ft2
0
0.6
0
5
-
Garage
Frame - Wood Main
13 27 0
10 01
270.0 ft2
0
0.23
0.01
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
E
Insulated Main
None
.25
3
6 8
20 ft2
2
-
Insulated Main
None
.25
2
8
6 8
17.8 ft2
r
WINDOWS
Orientation shown is the entered, Proposed orientation
V
Wall
Overhang
#
Ornt
ID
Frame
Panes NFRC
U-Factor, SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
S
1
Vinyl
Low-E Double
Yes
0.33 0.23
N
6.9 ft2
1 ft 4 in
0 ft 10 in
None
Exterior 5
2
S
1
Vinyl
Low-E Double
Yes
0.33 0.23
N
48.6 ft2
1 ft 4 in
0 ft 10 in
None
Exterior 5
3
E
2
Vinyl
Low-E Double
Yes
0.33 0.31
N
7.1 ft'
9 ft 0 in
0 ft 6 in
None
None
4
E
2
Vinyl
Low-E Double
Yes
0.33 0.21
N
16.2 ft-
1 ft 0 in
3 ft 11 in
None
Exterior 5
5
E
2
Vinyl
Low-E Double
Yes
0.33 0.21
N
16.2 ft'
1 ft 0 in
5 ft 4 in
None
Exterior 5
6
E
2
Vinyl
Low-E Double
Yes
0.33 0.31
N
13.3 ft'
9 ft 0 in
2 ft 0 in
None
None
7
N
3
Vinyl
Low-E Double
Yes
0.33 0.23
N
I
48.6 ft2
1 ft 4 in
0 ft 10 in
None
Exterior 5
8
W
4
Vinyl
Low-E Double
Yes
0.55 0.7
N
17.8 ftz
11 ft 5 in
0 ft 6 in
None
Exterior 5
9
W
4
Vinyl
Low-E Double
Yes
0.33 0.23
N
32.4 ft'
1 ft 4 in
0 ft 10 in
None
Exterior 5
10
W
4
Vinyl
Low-E Double
Yes
0.33 0.23
N
32.4 ft2
11 ft 6 in
0 ft 6 in
None
Exterior 5
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg Wall Height
Exposed Wall Insulation
1
596 ft2
596 ft2
64 ft
8
ft
1
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse
Proposed ACH(50) .000444
2123.3 116.49
218.7
.1381
7
HEATING SYSTEM
# System Type
Subtype
Speed
Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/
Split
Singl
HSPF:8.5
34.6 kBtu/hr
1
sys#1
2/9/2021 3:51 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4
FORM R405-2020 INPUT" SUMMARY CHECKLIST REPORT
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 Central, Unit/
Split
Singl SEER: 16
35 kBtu/hr
cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.94 40 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft2
DUCTS
/ ---- Supply ----
---- Return ----
Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1 Attic
6 364 ft2
Main
91 ft2 Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
i
Programable Thermostat: Y
Ceiling Fans:
Cooling Jan Feb
Heating f X Jan f X Feb
Mar
f X� Mar
f
Apr
Appr f
Jul
May 4 Jun Jul
May X Jun ri
Aug
AugSepp
ri
Sep
rl
Oct
Oct
. Nov
Nov
HX
Dec
Dec
H
Ventin [ Jan [ Feb
X Mar
[X]
A r [
Ma [ Jun Jul
Aug
Se
[X]
Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8
9
10
11
12
Cooling (WD) AM
78
78
78
78 78 78
78
78
80
80
80
80
PM
80
80
78
78 78 78
78
78
78
78
78
78
Cooling (WEH) AM
78
78
78
78 78 78
78
78
78
78
78
78
PM
78
78
78
78 78 78
78
78
78
78
78
78
Heating (WD) AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
Heating (WEH) AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture, Fraction
Space
Default 8 Ibs/sq.ft.
0 ft2
0 ft
0!3
Main
2/9/2021 3:51 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 4
FORM ,R405-2020
R
ENERGY PERFORMANCE LEVEL (EP'L) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 92
The lower the EnergyPerformance Index, the more efficient the home.
5348 Lugo Street, Fort Pierce, FL, 34951
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1850.00 ftz
b. Frame - Wood,' Adjacent
R=13.0
270.00 ftz
3. Number of units, if multiple family
1
c. N/A
R=
ftz
4. Number of Bedrooms
4
d. N/A
R=
ftz
5. Is this a worst case?
No
11. Ceiling Type and; insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
1820.00 ftz
6. Conditioned floor area (ftz)
1820
b. Knee Wall (Vented)
R=19.0
80.00 ftz
7. Windows*' Description
Area
c. N/A
R=
z
ft
a. U-Factor: Dbl, U=0.33
168.74 ftz
12. Ducts, location &, insulation level
R ftz
SHGC: SHGC=0.23
a. Sup: Attic, Ret: Main, AH: Main
6 364
b. U-Factor: Dbl, U=0.33
32.38 ftz
SHGC: SHGC=0.21
13. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: Dbl, U=0.33
20.42 ftz
a. Central Unit
35.0 SEER:16.00
SHGC: SHGC=0.31
d. U-Factor: other (see details)
17.78 ftz
SHGC: other (see details)
14. Heating systems
kBtu/hr
Efficiency
Area Weighted Average Overhang Depth:
4.067 ft.
a. Electric Heat Pump
34.6
HSPF:8.50
Area Weighted Average SHGC:
0.269
8. Skylights Description
Area
15. Hot water systems
a. U-Factor(AVG): N/A
ftz
a. c
Electric
Cap:
40 gallons
SHGC(AVG): N/A
EF:0.94
b. Conservation features
9. Floor Types
Insulation Area
None
a. Slab -On -Grade Edge Insulation
R=0.0 1820.00 ftz
Credits (Performance method)
Pstat
b. N/A
R= ftz
c. N/A
R= ftz
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: \ l 1) Date:
Address of New Home: City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For informatioin about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
2/9/2021 3:51 PM . EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1