HVAC Residential Loads
§ : wop 1;punty, Permitting Holland Res HVAC Load Calculations for Ando Building Corporation 389 Sebastian Blvd Sebastian, FL. 32958 RHVACWAC LoAm `�a� HVAC Co 4y� License# o t C4\C7816310 ua (321) 615-6562 Prepared By: Karen O'Brien A/C Service Masters, LLC 1473 Ashboro Circle SE Palm Bay, FL. 32909 321-615-6562 Thursday, May 16, 2019 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rhvac Resrdentral 8� Light Commercial HVAC Loads Elite Software Development, Inc. A/C Service Masters LLC � ' ' _- Holland. Res Palrrr,Ba ,FL°:32909 ' 3 .Y 1 Pa e2 Protect Report General Project Information " Project Title: Holland Res Designed By: John O'Brien Project Date: 5/15/2019 Client Name: Ando Building Corporation Client Address: 389 Sebastian Blvd Client City: Sebastian, FL. 32958 Client Phone: 772-589-5943 Client Fax: 772-589-5943 Company Name: A/C Service Masters, LLC Company Representative: Karen O'Brien Company Address: 1473 Ashboro Circle SE Company City: Palm Bay, FL. 32909 Company Phone: 321-615-6562 Company Fax: 321-956-9451 Company E-Mail Address: acservicemasters@yahoo.com Company Comment: Desi n Data , .. Reference City: Fort Pierce, Florida Building Orientation: Front door faces East Daily Temperature Range: Medium Latitude: 27 Degrees Elevation: 25 ft. Altitude Factor: 0.999 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 42 39.4 n/a n/a 72 n/a Summer: 90 78 59% 50% 75 61 Check.,Fi ures Total Building Supply CFM: 1,600 CFM Per Square ft.: 0.798 Square ft. of Room Area: 2,006 Square ft. Per Ton: 555 Volume (ft'): 20,060 Building Loads " ° ' Total Heating Required Including Ventilation Air: 39,586 Btuh 39.586 MBH Total Sensible Gain: 33,415 Btuh 83 % Total Latent Gain: 7,065 Btuh 17 % Total Cooling Required Including Ventilation Air: 40,480 Btuh 3.37 Tons (Based On Sensible + Latent) 3.62 Tons (Based On 77% Sensible Capacity) Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\ ...1Ando-Holland ... by room.rh9 Thursday, May 16, 2019, 3:08 PM Rhvac Residenttat & Light Commercial HVAG Loads r , ' Ehte Software Development, Inc AIG Service Masters, PLC ,� , "�� �� Holland Res: age, 3,. Miscellaneous Report System 1 �M'am Floor OutcJoor .. ,°Outdoors Outdoor Indoor, Indoor , , Grains Input- Data . : ' ;` , . D `Bulb r . ti W.etxBulb Rel:Hum ,' Rel.Hurn ° ` D Bulb Difference Winter: 42 39.4 80% n/a 72 n/a Summer: ! 90 78 59% 50% 75 61.09 Duct,Sizin In 0bli A , Main Trunk Runouts Calculate: Yes Yes Use Schedule: No No Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./l00 ft. 0.1000 in.wg./100 ft.. Minimum Velocity: 550 ft./min 450 ft./min Maximum Velocity: 600 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. Outside Air' -Data; Winter Summer Infiltration Specified: 0.320 AC/hr 0.160 AC/hr 107 CFM 53 CFM Infiltration Actual: 6.320 AC/hr 0.160 AC/hr Above Grade Volume: X 20,060 Cu.ft. X 20.060 Cu.ft. 6,,419 Cu.ft./hr 3,2.10 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 107 CFM 53 CFM Total Building Ventilation: 0 CFM 0 CFM i ---System 1-- Infiltration & Ventilation Sensible Gain Multiplier: 16.49 = (1.10 X 0.999 X 15.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 41.50 = (0.68 X 0.999 X 61.09 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 32.97 = (1.10 X 0.999 X 30.00 Winter Temp. Difference) Winter Infiltration Specified: 0.320 AC/hr (107 CFM), Construction: Average Summer Infiltration Specified: 0.160 AC/hr (53 CFM), Construction: Average puct� Load Factor.Scenaeios ;Attic r ''Duct Duct { Surface From No . T pe .. �Descnptfion,. „ s, Location ,'..Ceilin �;Leakage �; Insulation!�� Area;' " T MDD 1 Supply Main Attic! 16B 0.12 6 542 No 1 Return Main Attic 16B 0.24 6 401 No i C:\ ...\Ando-Holland ... by room.rh9 Thursday, May 16, 2019, 3:08 PM Rhvac Residential &Light Commercial HVAC Loads Elite.Software Development, Inc At, Service Masters, L'LC., f " H011antl Res` PalroBay, FLa32909 - t r �. Page+ Load Preview Report.." Nei Rec ft. Sen La NetSen Sys Sy q Duct Scope To To rro Are GainGai Gai Loss CFM CFM CFM SiZ Building 3.37 3.62 555f 2,006 33,415 7,065 40,480 39,586 1,606 1,600 1,606 System 1 3.37 3.62 555 2,006 33,415 7,065 40,480 39,586 1 600 1 600 1,600 23 Supply Duct Latent 393 393' Return Duct 5,757 2,631 8,388 1,891 Zone 1 2 006 27,658 4,041 31,699 37,694 1 6004 1 600 1,600 23 1-Master Bedroom 224 4,136 767 4,903 5,377 228 2301 239 2-6 2-Master Bath 360: 1,308 256 1,564 4,217 179 76 76 4-3 3-Bedroom 3 144 3,771 557 4,328 5,133 218t 218' 218' 2-6 4-Bath 3 72• 347. 41 388 776 - 33 °; 2Qf 20 1-3 5-Foyer 132- 820 123 943 2,138 91 47 47; 1-4 6-Great Room 342 3,491 194 3,685 4,101 174 202r 202 2-6 7-Dining 182 3392 379' 3,771 6,459 2741 196 196 1-8 8•IGtchen 195 5679 1,054 6,733 2,469 105 329; 329 1-1 9-Bedroom 2 187, 3202 547` 3,749 4,899 2081-, y 1.85185' 1-8 10-Bedroom 2 Utility Room Bath 2 168' 1,512 123 1,635 2,126 901 8787 1-5 CA ...Wndo-Holland ... by roorrlA9 Thursday, May 16, 2019, 3:08 PM Rhvac - Residential,& Lig4t Commercial HVAC Loads Elite Software Development, Inc. A/C'S ervice Masters;LLC Holland Res Palm Ba , FL 32009. _ Page 5 Duct Size Preview Roam or Source Minimu Maximu Rough Desig SP Du Du Htg Clg Act. Duct Duct Name Veloci Veloci Facto Ltl0 Loss Veloci Lengt Flow Flow Flow Size System 1 Supply Runouts Zone 1 1-Master Bedroom Built -In 450 750' 0.01 0.1` 609.3 2281MI 239 2-6 2-Master Bath Built -In 450 750 0.01 0.1 385.4 179�7 76 4-3 3-Bedroom 3 Built -In 450 7501 0.01. 0.1, 555.5 218 21 I 218' 2-6 4-Bath 3 Built -In 450 750' 0.01 0.1. 409.1 330K20:I 20' 1-3 5-Foyer Built -In 450 750 0.01; 0.1, 543.6 91, 4• 47 1 6-Great Room Built -In 450` 750 0.01: 0.11 514.2 1741 202 2-6 7-Dining Built -In 450 750 0.01' 0.1' 562.2 274®1 196' 14 8-Kitchen Built -In 450 750 0.010.1 602.3 105IMM 329 1-1 9-Bedroom 2 Built -In 450 750 0.01I 0.1' 530.7 208 185, 1-8 10 Bedroom 2 Utility Room Bath 2 Built -In 450 750 0.01 0.1: 641.3 90,® 8T 1-5 Other Duds In System 1 - Supply Main Trunk Built -In 550 600 0.003 0.1; 554.6 1,600 1,60 1,600 23 Summary System 1 Heating Flow: 1600 Cooling Flow: 1600 CA ...V1ndo-Holland ... by room.rh9 Thursday, May 16, 2019, 3:08 PM Cooling System Type: Outdoor Model: Indoor Model: Tradename: Outdoor Manufacturer: Description: AHRI Reference No.: Capacity: Efficiency: Heating System Type: Model: Tradename: Manufacturer: Description: Capacity: Efficiency Air Source Heat Pump GSZ160481 B* ASPT49D14A* GSZ16 GOODMAN Air Source Heat Pump 201668005 45,500 16 SEER i Air Source Heat Pump GSZ160481 B* GSZ16 GOODMAN Air Source Heat Pump 47,000 9 HSPF This system's equipment was selected in accordance with ACCA Manual S. Manual S equipment sizing data: SODB: 90F, SOWB: 78F, WODB: 42F, SIDB: 75F, SIRH: 50%, WIDB: 72F, Sen. gain: 33,415 Btuh, Lat. gain: 7,065 Btuh, Sen. loss: 39,586 Btuh, Entering clg. coil DB: 78.31F, Entering clg. coil WB: 63.6F, Entering htg. coil DB: 70.91F, Clg. coil TD: 20F, Htg. coil TD: 70F, Req. clg. airflow: 1258 CFM, Req. htg. airflow: 490 CFM C:\ ...\Ando-Holland ... by room.rh9 I Thursday, May 16, 2019, 3:08 PM Rhvac Resrdenttal & Light Commercial HVAC Loads Elite Software Development, Inc; A/C Semce Masters CLC _ I?alrribl3a = and Res " „FL'32909 P ,. Detailed Room Loads- Roorn 1 -Master Bedroom (A�erage LoadProcedure) •General ° p ., Calculation Mode: Htg. &clg. Occurrences: 1 Room Length: 14.0 ft. System Number: 1 " Room Width: 16.0 ft. Zone Number: 1 Area: 224.0 sq.ft. Supply Air: 239 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 6.4 AC/hr Volume: 2,240 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: � 2 Actual Winter Vent.: 0 CFM Runout Air: 120 CFM Percent of Supply.: 0 % Runout Duct Size: 6 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 609 ft./min. Percent of Supply: 0 % Runout Air Velocity: 609 ft./min. Actual Winter Infil.: 15 CFM Actual Loss: 0.237 in.wg./100 ft. Actual Summer Infil.: 7 CFM Item `r 'Area ` U .Sen Cl' : L`at,a Sem Des'cnption� Quanti`` \(alue° HTM L' oss ., HTM ' ... Gain.' Gain W -Wall-13A-4fcs 16 X 10 88 0.117 3.5 309 1.8 0 158 S -Wall-13A-4fcs 14 X 10 C 140 0.117 3.5 491 1.8 0 251 W -GIs-3A-v-d shgc-0.27 1000%.S (3) 1 72 0.350 10.5 756 9.8 0 708 UP-Ceil-1613-30 14 X 16 224 0.032 1.0 215 1.0 0 215 Floor-22A-rm 30 ft.. Per. 30 1.180 64.9 1,947 0.0 0 0 Subtotals for Structure: 3,718 0 1,332 Infil.: Win.: 14.8, Sum.: 7.4 300 1.627 488 0.407 307 122 Ductwork: 1,171 746 AED Excursion: 364 People: 230 lat/per, 300 sen/per: 2 460 600 Equipment: 0 972 Room Totals: 5,377 767 4,136 Equpme"ntCoolin;toads;„ '° ` `�" Cont ,Cont f Output Output,; Avg �'Pctl Sens`. 'Lat. .� 'Serfs Lat c}, In - Use Used Load, Load` Iterrr Name ' x Btuh Btuh t e, Out ut.F > ' /Hour . s ' Btuh Btuh Ceiling fan 250 0 100 100 250 0 Color television 683 0 100 100 683 0 Desk radio or clock radio 52 0 75 100 39 0 Total II 972 0 C:\ ...\Ando-Holland ... by room.rh9 Thursday, May 16, 2019, 3:08 PM Rhvac Residential &Light Commercial HVAC Loads Ehte.Software Development, Inc.'. A/C'Srvlce rs Maste3 LLC , Holland Res Palm"`Ba , FL `32909 FQ s��. Pa e.8r DetaiIed Room Loads. - Rodrn 2 = Master Bath (Average Load Procedure) J`G61eral Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 20.0 ft. System Number: 1 Room Width: 18.0 ft. Zone Number: 1 Area: 360.0 sq.ft. Supply Air: 76 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 1.3 AC/hr Volume: 3,600 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 4 Actual Winter Vent.: 0 CFM Runout Air: - 19 CFM Percent of Supply.: 0 % Runout Duct Size: 3 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 385 ft./min. Percent of Supply: 0 % Runout Air Velocity: 385 ft./min. Actual Winter Infil.: 12 CFM Actual Loss: 0.255 in.wg./l00 ft. Actual Summer Infil.: 6 CFM Item ° Area U „ , Htg n, Sen Clg Lat ra" Sern D6scr`i tion <w _ ., . Quantif Value HTM Loss HTM Gain ° Gain S -Wall-13A-4fcs 17 X 10 164 0.117 3.5 576 1.8 0 294 E -Wall-13A-4fcs 8 X 10 80 0.117 3.5 281 1.8 0 143 S -GIs-3A-v-o shgc-0.31 100%S 6 0.370 11.1 67 12.0 0 72 UP-Ceil-16D-30 20 X 18 360 0.032 1.0 346 1.0 0 346 Floor-22A-rm 25 ft..Per. 25 1.180 64.9 1,622 0.0 0 0 Subtotals for Structure: 2,892 0 855 Infil.: Win.: 12.3, Sum.: 6.2 250 1.624 406 0.408 256 102 Ductwork: 919 236 AED Excursion: 115 Room Totals: 4,217 256 1,308 Q\ ...\Ando-Holland ... by room.rh9 Thursday, May 16, 2019, 3:08 PM Rhvac Residential & Light Commercial HVAC Loads A/C Service Masters LLC Elite Software Development, Inc. Holland Res Palm. Ba , FL • 32909 .. , .. . •` . :.• ` " Pa e 9 Detailed Room Loads = Room 3 =: Bedroom 3 (Average :Load Procedure); . '[General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 12.0 ft. System Number: 1 Room Width: 12.0 ft. Zone Number: 1 Area: 144.0 sq.ft. Supply Air: 218 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 9.1 AC/hr Volume: 1,440 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 2 Actual Winter Vent.: 0 CFM Runout Air: 109 CFM Percent of Supply.: 0 % Runout Duct Size: 6 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 556 ft./min. Percent of Supply: 0 % Runout Air Velocity: 556 ft./min. Actual Winter Infil.: 16 CFM Actual Loss: 0.197 in.wg./100 ft. Actual Summer Infil.: 8 CFM Item Description Area i,' U ;,; Htg � en-2 Quantit ` a { Value! ` HTM ; Loss ' Clg Lat c' H7 fVf Gain" Sen° Gain. S -Wall-1-4fcs 12" X 10 120 0.117 3.5 421 1.8 0 215 E -Wall-I3A-4fcs 12 X 10 93 0.117 3.5 326 1.8 0 166 N -Wall-13A-4fcs 8 X 10 80 0.117 3.5 281 1.8 0 143 E -GIs-3A-v-o shgc-0.26 12%S 13.5 0.310 9.3 126 27.1 0 367 E -GIs-3A-v-o shgc-0.26 12%S 13.5 0.310 9.3 126 27.1 0 367 UP-Ceil-1613-30 12 X 12 144 0.032 1.0 138 1.0 0 138 Floor-22A-rm 32 ft..Per. 32 1.180 64.9 2,077 0.0 0 0 Subtotals for Structure: 3,495 0 1,396 Infil.: Win.: 15.8, Sum.: 7.9 320 1.625 520 0.406 327 130 Ductwork: 1,118 680 AED Excursion: 332 People: 230 lat/per, 300 sen/per: 1 230 300 Equipment: 0 933 Room Totals: 5,133 557 3,771 E uipment'Cooling.Loads - _ Cont. Cont. Output Output' Avg. Pct-. Sens.. Lat. .Sens Lat In -Use Used :Load Load Item Name` :- :i'` Btuh . Btuli-,,-`.Out ut `/Hourh Btuh.; Btuh` Color television 683 0 100 100 683 0 Ceiling fan 250 0 100 100 250 0 Total 933 0 C:\ ...\Ando-Holland ... by room.rh9 Thursday, May 16, 2019, 3:08 PM Rhvac_ Residential & Light Commercial HVAC Loads Elite Software Development, Inc. - AIC Service Masters °L LC v Holland Res_ - P6lM:56 ,.FL.329Q%"' . Detailed Root' Loads - Room 4 - Bath 3. (Average Load Procedure) General Calculation Mode: Htg. & c1g. Occurrences: 1 Room Length: 6.0 ft. System Number: 1 Room Width: 12.0 ft. Zone Number: 1 Area: 72.0 sq.ft. Supply Air: 20 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 1.7 AC/hr Volume: 720 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 20 CFM Percent of Supply.: 0 % Runout Duct Size: 3 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 409 ft./min. Percent of Supply: 0 % Runout Air Velocity: 409 ft./min. Actual Winter Infil.: 2 CFM Actual Loss: 0.287 in.wg./100 ft. Actual Summer Infil.: 1 CFM Item'; Area F -U= a; Htg ;Sian Qlg Lati : Son-' Description Quantit-- ,' Value' HTM Loss . HTM ,' - Gain Gain S -Wall-13A-4fcs 4 X 10 30.6 0.117 3.5 107 1.8 0 55 S -GIs-3A-v-o shgc-0.31 100%S 9.4 0.370 11.1 105 12.1 0 114 UP-Ceil-16D-30 6 X 12 72 0.032 1.0 69 1.0 0 69 Floor-22A-rm 4 ft.. Per. 4 1.180 64.9 260 0.0 0 0 Subtotals for Structure: 541 0 238 Infil.: Win.: 2.0, Sum.: 1.0 40 1.625 65 0.400 41 16 Ductwork: 169 63 AED Excursion: 31 Room Totals: 775 41 347 Q\ ...\Ando-Holland ... by room.rh9 Thursday, May 16, 2019, 3:08 PM Rhvac Residential & Light Commercial HVAC Loads Elite Software Devel opment, Inc. AIC Service Masters LLC _ � Res, Palm I a FL''32909 ; , , _Holland Pa a 11 . Detailed Room Loads:. -: Room 5 - Foyer (A'verage Load `Proceddre)_ General . . Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 6.0 ft. System Number: 1 Room Width: 22.0 ft. Zone Number: 1 Area: 132.0 sq.ft. Supply Air: 47 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 2.2 AC/hr Volume: 1,320 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 47 CFM Percent of Supply.: 0 % Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 544 ft./min. Percent of Supply: 0 % Runout Air Velocity: 544 ft./min. Actual Winter Infil.: 6 CFM Actual Loss: 0.333 in.wg./100 ft. Actual Summer Infil.: 3 CFM ItemSen Description ` Quantity Value HTM, Loss' HTMA Gain:' Gain' E -Wall-13A-4fcs 6 X 10 36 0.117 3.5 126 1.8 0 64 N -Wall-12C-Osw 6 X 10 60 0.091 2.7 164 2.0 0 117 E-Door-11 D 3 X 8 24 0.390 11.7 281 10.1 0 243 UP-Ceil-16D-30 6 X 22 132 0.032 1.0 127 1.0 0 127 Floor-22A-rm 12 ft..Per. 12 1.180 64.9 779 0.0 0 0 Subtotals for Structure: 1,477 0 551 Infil.: Win.: 5.9, Sum.: 3.0 120 1.625 195 0.408 123 49 Ductwork: 466 148 AED Excursion: 72 Room Totals: i 2,138 123 820 C:\ ...Wndo-Holland ... by room.rh9 Thursday, May 16, 2019, 3:08 PM Rhvac Residential & Light Commercial HVAC Loads Ehte.Soflware Development, Inc. A/C;Se ice MasLLC ters, Holland F2es Palm 'Ba , FL.` 32909 .: Page .11 Detailed Room Loads -. Roort� 6 - Great Room (Average Load Procedure) .General Calculation Mode: Htg. &' clg. Occurrences: 1 Room Length: 18.0 ft. System Number: 1 Room Width: 19.0 ft. Zone Number: 1 Area: 342.0 sq.ft. Supply Air: 202 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 3.5 AC/hr Volume: 3,420 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 2 Actual Winter Vent.: 0 CFM Runout Air: 101 CFM Percent of Supply.: 0 % Runout Duct Size: 6 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 1514 ft./min. Percent of Supply: 0 % Runout Air Velocity: 514 ft./min. Actual Winter Infil.: 9 CFM Actual Loss: 0.169 in.wg./100 ft. Actual Summer Infil.: 5 CFM Item` Area , -U- `;; Htg Sen . Y Clg Lat Sin, Description Quanti ` ' Value HTM 'Loss HTM • Gain' Gain W -Wall-13A4fcs 19 X 10 94 0.117 3.5 330 1.8 0 168 W -GIs-3A-v-d shgc-0.27 100%S (4) 96 0.350 10.5 1,008 10.9 0 1,048 UP-Ceil-I6D-30 18 X 19 342 0.032 1.0 328 1.0 0 328 Floor-22A-rm 19 ft..Per. 19 1.180 64.9 1,233 0.0 0 0 Subtotals for Structure: 2,899 0 1,544 Infil.: Win.: 9.4, Sum.: 4.7 190 1.626 309 0.405 194 77 Ductwork: 893 630 AED Excursion: 307 Equipment: 0 933 Room Totals: 4,101 194 3,491 Equi.pmerit-Cooling; Loads Cont. Cont. Out ut Output Av . P 9 Pct Sens.. Lat. Lat. I n-Use ' Used " Load,; Load Item Name; "Sens.'' Btuh . Btuh . Output /Hour'; 'Btuh ,j Btuh Ceiling fan 250 0 100 100 250 0 Color television 683 0 100 100 683 0 Total 933 0 C:\ ...\Ando-Holland ... by room.rh9 Thursday, May 16, 2019, 3:08 PM Rhvac Residential & Light Commercial HVAC Loads Elite Software Development, Inc. A/C 8ervice Masters,11-C Holland Res Palm Ba , FL 32909 Pa a 13 Detailed Room Loads -Room 7-Dining (Average Load Procedure) .General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 13.0 ft. System Number: 1 Room Width: 14.0 ft. Zone Number: 1 Area: 182.0 sq.ft. Supply Air: 196 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 6.5 AC/hr Volume: 1,820 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 196 CFM Percent of Supply.: 0 % Runout Duct Size: 8 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 562 ft./min. Percent of Supply: 0 % Runout Air Velocity: 562 ft./min. Actual Winter Infil.: 18 CFM Actual Loss: 0.136 in.wg./100 ft. Actual Summer Infil.: 9 CFM Item' Area ` :, -ll-.,.. Htg „` Sen Pig, L at ; Sen Description 'Quantity,'. Value,';' HTM ` `Loss_' HTM " 'Gain',: Gain, N -Wall-13A-4fcs 14 X 10 140 0.117 3.5 491 1.8 0 251 W -Wall-13A-4fcs 13 X 10 88.4 0.117 3.5 310 1.8 0 158 S -Wall-13A-4fcs 10 X 10 52 0.117 3.5 183 1.8 0 93 S -GIs-3A-v-d shgc-0.27 100%S (2) 48 0.350 10.5 504 10.9 0 524 W -GIs-3A-v-o shgc-0.26 12%S (2) 20.8 0.310 9.3 194 27.2 0 566 W -GIs-3A-v-o shgc-0.26 12%S 20.8 0.310 9.3 193 27.2 0 565 UP-Ceil-16D-30 13 X 14 182 0.032 1.0 175 1.0 0 175 Floor-22A-rm 37 ft.. Per. 37 1.180 64.9 2,401 0.0 0 0 Subtotals for Structure: 4,451 0 2,332 Infil.: Win.: 18.2, Sum.: 9.1 370 1.624 601 0.405 379 150 Ductwork: 1,407 612 AED Excursion: 298 Room Totals: 6,459 379 3,392 C:\ ...\Ando-Holland ... by room.rh9 Thursday, May 16, 2019, 3:08 PM Rhvac m Residential,& Light Commercial HVAC Loads A/C Service Masters ;LLC _ Elite Software Development, Inc. Holland Res `Palm Bay', FL 32909_,. ., Page' 14 Detailed Room Loads - Room 8 - Kitchen (Average_Load .Procedure) Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 15.0 ft. System Number: 1 Room Width: 13.0 ft. Zone Number: 1 Area: 195.0 sq.ft. Supply Air: 329 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 10.1 AC/hr Volume: 1,950 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 329 CFM Percent of Supply.: 0 % Runout Duct Size: 10 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 602 ft./min. Percent of Supply: 0 % Runout Air Velocity: 602 ft./min. Actual Winter Infil.: 7 CFM Actual Loss: 0.115 in.wg./100 ft. Actual Summer Infil.: 4 CFM Item .. '. > " �-,Description.° Area -U- ` Quantity °• . Value ; g . , Ht Sen , HTM„ .". .Loss Clg HTM " . Lat. Gain:` Sen Gain, N -Wall-I3A-4fcs 15 X 10 150 0.117 3.5 527 1.8 0 269 UP-Ceil-16D-30 15 X 13 195 0.032 1.0 187 1.0 0 187 Floor-22A-rm 15 ft.. Per. 15 1.180 64.9 973 0.0 0 0 Subtotals for Structure: 1,687 0 456 Infil.: Win.: 7.4, Sum.: 3.7 150 1.627 244 0.407 153 61 Ductwork: 538 1,025 AED Excursion: 499 Equipment: 901 3,638 Room Totals: 2,469 1,054 5,679 E q ui meet Coolie ;Loads t Cont. Cont. Output,, Output ' ' Avg. Pct Sens. Lat. Sens. Lat., In -Use.: Used Load' Load Item Name Btuh Btuh Output : /Hour _ Btuh Btuh Coffee maker - brewer 1331 717 100 25 333 179 Cooking range with hood - four burners on high heat 0 0 100 100 0 0 Toaster 3532 392 100 10 353 39 Dishwasher 4096 1433 100 25 1024 358 Microwave 4949 1732 75 25 928 325 Refrigerator or freezer -16 cubic feet 1000 0 100 100 1000 0 Total 3638 901 Q\ ...Wndo-Holland ... by room.rh9 Thursday, May 16, 2019, 3:08 PM •Rhvac -,Residential & Light, Commercial' HVA_ C Loads A/C Service Masters LLC Elite Software Development, Inc. Holland Res Palm Ba , FL 32909.::;.., Detailed Room Loads -Room 9 -Bedroom 2 (Average. -Load Procedure): General Calculation Mode: Htg. &,clg. Occurrences: 1 Room Length: 1.7.0 ft. System Number: 1 Room Width: 11.0 ft. Zone Number: 1 Area: 187.0 sq.ft. Supply Air: 185 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 5.9 AC/hr Volume: 1,870 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 185 CFM Percent of Supply.: 0 % Runout Duct Size: 8 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 531 ft./min. Percent of Supply: 0 % Runout Air Velocity: 531 ft./min. Actual Winter Infil.: 15 CFM Actual Loss: 0.121 in.wg./100 ft. Actual Summer Infil.: 8 CFM Item j . Area {, U- ; Htg Sen Clg .tat f, Son Description Quantity Value" HTM,' HTM �. Gain ,_ Gain N -Wall-13A-4fcs 17 X 10 143 0.117 3.5 502 1.8 0 256 E -Wall-12C-Osw 11 X 10 110 0.091 2.7 300 2.0 0 215 S -Wall-12C-Osw 3 X 10 30 0.091 2.7 82 2.0 0 59 N -GIs-3A-v-o shgc-0.26 100%S (2) 27 0.310 9.3 252 10.1 0 274 UP-Ceil-16D-30 17 X 11 187 0.032 1.0 180 1.0 0 180 Floor-22A-rm 31 ft..Per. 31 1.180 64.9 2,012 0.0 0 0 Subtotals for Structure: 3,328 0 984 Infil.: Win.: 15.3, Sum.: 7.6 310 1.626 504 0.406 317 126 Ductwork: 1,067 578 AED Excursion: 282 People: 230 lat/per, 300 sen/per: 1 230 300 Equipment: 0 933 Room Totals: ! 4,899 547 3,202 Equipment Cooling Loads u Cont. Cont. Output Output. Avg. Pct Sens.: at., Sens. Lat. ' In -Use Used, Load ' Load . Item Name Btuli Bfuh- Out ut . /Hour'; Btuh ' Btu Ceiling fan 250 0 100 100 250 0 Color television 683 0 100 100 683 0 Total 933 0 C:\ ...1Ando-Holland ... by room.rh9 Thursday, May 16, 2019, 3:08 PM Rhvac Residential & Light Commercial HVAC Loads ;• Elite Software Development, Inc: A/C Service Masters , LLC Holland Res Palm Bay, FL _ 32909 , , = - Ra a 16 Detailed: Room Loads - Room. 10 - Bedroom 2 Utility Room. Bath 2:(Average Load Procedure) General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 12.0 ft. System Number: 1 Room Width: 14.0 ft. Zone Number: 1 Area: 168.0 sq.ft. Supply Air: 87 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 3.1 AC/hr Volume: 1,680 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 87 CFM Percent of Supply.: 0 % Runout Duct Size: 5 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 641 ft./min. Percent of Supply: 0 % Runout Air Velocity: 641 ft./min. Actual Winter Infil.: 6 CFM Actual Loss: 0.338 in.wg./100 ft. Actual Summer Infil.: 3 CFM Item ; " Area -U-' Htg " . _ Sen Clg Lat. Sen Description Quanti 'Value HTM Loss ; HTM Gain Gain E -Wall-12C-Osw 12 X 10 97.6 0.091 2.7 266 2.0 0 191 E -Door-11 D 2.8 X 8 22.4 0.390 11.7 262 10.1 0 227 UP-Ceil-16D-30 12 X 14 168 0.032 1.0 161 1.0 0 161 Floor-22A-rm 12 ft..Per. 12 1.180 64.9 779 0.0 0 0 Subtotals for Structure: 1,468 0 579 Infil.: Win.: 5.9, Sum.: 3.0 120 1.625 195 0.408 123 49 Ductwork: 463 273 AED Excursion: 133 Equipment: 0 478 Room Totals: 2,126 123 1,512 Equipment Coolin ,;Loads ` _ Cont. " Cont. Output-: Output , Avg Pct . Sens., tat. Sens. " :-_Lat. , Ir Use Used, Load Load, Item Name ` Btuh Btuh , Output, /Hour:, Btuh ` Btuh Clothes washing machine -10 percent to space 205 0 50 50 51 0 Vented clothes dryer -10 percent to space 1707 0 50 50 427 0 Total 478 0 C:\ ...\Ando-Holland ... by room.rh9 Thursday, May 16, 2019, 3:08 PM Light Commercial HVAC Loads-;. AIC Service Masters, &LC Ralm 6r ResidentialF mast Elite Software Development, Inc. Holland Res_ P 09 DIY Pa � e 17 System 1 Rom Load Summary Htg Min . Run, Run Clg Clg Min Act Room Area Sens,, HtgDuct Duct Sens Lat Clg Sys -No, Name, SF Btuh., CFM Size - Vel Btuh Btuh CFM;, CFM' ---Zone 1--- 1 Master Bedroom 224 5,377 70 2-6 609 4,136 767 188 239 2 Master Bath 360 4,217 55 4-3 385 1,308 256 60 76 3 Bedroom 3 144 5,133 67 2-6 556 3,771 557 172 218 4 Bath 3 72 ' 775 10 1-3 409 347 41 16 20 5 Foyer 132 2,138 28 1-4 544 820 123 37 47 6 Great Room 342 4,101 53 2-6 514 3,491 194 159 202 7 Dining 182 6,459 84 1-8 562 3,392 379 154 196 8 Kitchen 195 2,469 32 1-10 602 5,679 1,054 258 329 9 Bedroom 2 187 4,899 64 1-8 531 3,202 547 146 185 10 Utility 168 2,126 28 1-5 641 1,512 123 69 87 Room Bath 2 Duct Latent 393 Return Duct 1,891 5,757 2,631 System 1 total 2,006 39,586 490 33,415 7,065 1,258 1,600 System 1 Main Trunk Size: 23 in. Velocity: 555 ft./min Loss per 100 ft.: 0.024 in.wg Cooling System Summary - "Cooling Sensible/Latent Sensible Latent Total,. Tons . Split, Btuh , Btuh Btuh.. Net Required: 3.37 83% / 17% 33,415 7,065 40,480 Recommended: 3.62 77% / 23% 33,415 9,981 43,396 Actual: 3.79 77% / 23% 35,035 10,465 45,500 Equipment Data _ - ,Heating System Cooling System Type: Air Source Heat Pump Air Source Heat Pump Model: GSZ160481 B* GSZ160481 B* Indoor Model: ASPT49D14A* Brand: GSZ16 GSZ16 Description: Air Source Heat Pump Air Source Heat Pump Efficiency: 9 HSPF 16 SEER Sound: 0 0 Capacity: 47,000 Btuh 45,500 Btuh Sensible Capacity: n/a 35,035 Btuh Latent Capacity: n/a 10,465 Btuh AHRI Reference No.: n/a 201668005 This system's equipment was selected in accordance with ACCA Manual S. Manual S equipment sizing data: SODB: 90F, SOWB: 78F, WODB: 42F, SIDB: 75F, SIRH: 50%, WIDB: 72F, Sen. gain: 33,415 Btuh, Lat. gain: 7,065 Btuh, Sen. loss: 39,586 Btuh, Entering clg. coil DB: 78.3F; Entering clg. coil WB: 63.6F, Entering htg. coil DB: 70.9F, Clg. coil TD: 20F, Htg. coil TD: 70F, Req. clg. airflow: 1258 CFM, Req. htg. airflow: 490 CFM C:\ ...\Ando-Holland ... by room.rh9 Thursday, May 16, 2019, 3:08 PM • ACCK Ai cMffiatfigCartramsdArtv� Contractor A/C Service MAsters ,LLC Mechanical License # CAC1816310 Building Plan # County, Town, Municipality, Jurisdiction Header Information REQUIRED ATTACHMENTS' Manual A Form (and supporting worksheets): or MJ1AE Forme (and supporting worksheets): OEM performance data (heating, cooling, blower): Manual D Friction Rate Worksheet: Duct distribution system sketch: Home Address (Street or Lot#, Block, Subdivision) 1836 Wildcat Cove Dr Fort Pierce, FL. 34949 Design Conditions Winter Design Conditions Outdoor temperature Indoor temperature Total heat loss 42 72 39586 Form RPER 1.01 8 Mar 10 ATTACHED Yes X❑ No ❑ Yes ❑ No ❑X Yes ❑ No ❑X Yes ❑ No ❑X Yes ❑ No ❑X Building Construction Information Building OF Orientation (Front door faces) East OF North, East, West, South, Northeast, Northwest, Southeast, Southwest Btu/h Number of bedrooms 3 Summer Design Conditions Conditioned floor area Outdoor temperature 90 OF Number of occupants O 2006 Sq Ft Indoor temperature 75 F Windows Roof Grains difference 61 o Gr @ 50 % Rh Eave overhang depth 7.4 Ft Sensible heat gain 33415 Btu/h Internal shade Eave Latent heat gain 7065 Btu/h Blinds, drapes, etc Depth Window Total heat gain 40480 Btu/h Number of skylights 0 HVAC EQUIPMENT SELECT• 40 Heating Equipment Data Cooling Equipment Data Blower Data Equipment type Heat pump Equipment type Heat pump Heating CFM 1600 CFM Furnace, Heat pump, Boiler, etc. Air Conditioner, Heat pump, etc Model GSZ160481 B* Model GSZ160481 B* CFM Heating output capacity 47000 Btu/h Sensible cooling capacity Heat pumps - capacity at winter design outdoor conditions Latent cooling capacity Auxiliary heat output capacity Btu/h Total cooling capacity 35035 Btu/h 10465 Btu/h 45500 Btu/h Cooling CFM 1604 Design airflow 1600 CFM Longest supply duct: Ft Duct Materials Used (circle) Trunk Duct: Duct board, Flex, Sheet metal, External Static Pressure (ESP) IWC Longest return duct: Ft Lined sheet metal, Other (specify) Component Pressure Losses (CPL) IWC Total Effective Length (TEL) Ft Branch Duct: Duct board, Flex, Sheet metal, Available Static Pressure (ASP) IWC Friction Rate: IWC Lined sheet metal, Other (specify) ASP = ESP - CPL Friction Rate = (ASP x 100) - TEL Contractor's Printed Name Contractor's Signature 2 If abridged version of Manual J is used for load calculation, then verify residence meets requirements, see Abridged Edition Checklist on page 13 of instructions. Form generated by ACCA-approved Manual J Eighth Edition Version 2 Elite Software Rhvac program.