Loading...
HomeMy WebLinkAboutRevisions; Product Approval to Reflect Correct Impact WindowsOFFICE USE ONLY: DATE FILED: REVISION FEE: PLANNING & DEVELOPMENT, SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 (772)_ 462-1553 FAX (772) 462-1578 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION 1. LOCATION/S E . ADDRESSc. ALTA LOMA 3. CONTRACTORINFORMATION: STATE of FL REG./CERT. #: : BUSINESS NAME: Wynne Buildingorpora ST. LUCIE COUNTY CERT. #: 8898 ion QUALIFIERS NA ADDRESS: �UUb,South U Hwy, Suite 402 CITY: Fort St.,ucie STATE: ZIP:. PHONE (DAYTIME): - FAX: 772 878-7656 . 4. OWNER/BUILDER INFORMATION: NAME: Wynne -Building Corporation ADDRESS:.8000 South Hwy. 1 Suite:402. CITY: STATE: FL ZIP: 34952 PHONEc �(�5) 878-5513 FAX:. (772) 878-7656 5. ARCHITECT/ENGINEER INFORMATION: NAME:. BRADEN & BRADEN ADDRESS: CITY: STUART STATE: FL ZIP:.34996 PHONE (DAYTIME): (772) 287-8258 FAX: Revised 07/22/2014 Q REVISION r� I. A., P. A. > - d nl lannem 417 COCONUT` AVENUE, STUART, FLORIDA 3499E TELEPHONE: (772) 2B7-8258 FAX (772) 287-8283 #AAC-000032 St. Lucie County Bldg Dept I L 4-4-21 Wynne Develo ment Permit : 3,4 l— CODE COMPLIANCE Address 34 Altaa Loma To whom it may concern, ` . LU , -� �E COUNTY This is the revised product approval for/3/�r the wynne models showing the revised pro uct� If you have any questions please feel free to call me at 1-12-2 1-8258. SI c r y R. Braden - Braden i Braden Product Approval Submittal Affidavit 7 Opening Schedule Swing Doors. Overhead Doors. Sliding Doors. Windows I Skylights Opening Type NOA/FL NUMBER product Model tt Manufacturer Glass Attachment method TEST Expiration n Pressure Design sure 9 Date of Approved Teats 1,2.3 FLtt 239.4 Single Hung SH-1100A Impact PGT 5/14" 1/4" din. tapcona w/ min. 1 3/8' penetration to be spaced per product approval. Contractor shall adhere to + 65.0/-80.0 PS min. edge distances specified in Product approval A 20-I005.08 Overhead Model 624/811 18'-2" max width DAB ii . bgrxv.n a0 3ia• x`v°"`,►+""W c ai..�. o pul u' din ®: m :a i`..b.,e Garage Door I4'-0" max height Door Compang sAi'c' . i s')'i'e—av as .a"r e.: iiirws. n tine. —"a w ■e p d� to wit eppwwi 3-21-22 +'40.0/-44.0 PSF B FLtt 15213.1 Fiberglass Smooth Fiberglass Plast-Pro I/4` dia. tapcon with min 1.25' embedment at 6" max from corners and 14.5" o.c. max. thereafter in jamba. +65.0/-10.0 C FLtt 251.4 Sliding Glass Series 1"10 SGD PGT 1" nom 1/4' die. tapcona m/ min. 1 3/4' penetration to 6e spaced per product approval. Contractor shall adhere to Door Type "GSA" min. 2 I/2' edge distances specified in Product approval + 60.0 PSF _ Product NOA/FL Model tt Manufacturer AttMethod ExpT Ex iration Design 9n pressure NUMBER Date of Approved Testa CM-18531 For CMU use (2) 1/4' x 2 3/4' tapcons with min 1 1/4" embedment Mullions FLtt IS3S3.8 vertical mullion Mr Windows and doors, penetration into each Mull Clip. Attach mull to clip using (4) #10 x 1.25' calf tapping screws per clip as shown in product approval. + 118.9 PSF Roof FLU 33818.2 5V Crimp Gulf Coast Supply 26 a. 5v crimp metal roling �ittached to plywood deck using x9-15 x 15' HWI� wood screws uwth set sisaing waaher at 2" o.c max spacingpor Sdstem Roof Zone Metal Roofin g and manufacturing g no. SV-Type I tar max pressure -94.25 pat. Install per aystem 5pV type 2 formax pressure of -130 ppaf. Fasteners shall be installed through underla - I/2E/2R: - 94.25 PSF ment and attached to/throu®h I wood per sheeting attachment detail on rZ plan. Plywood to be 19/32 �l�X. 2N/3/3E/3R: -131.0 PSF Underlay FLtt 20816.1 DuPont Protec I60 T vek y DuPont Install two lagers of Tgvak horizontal)? in shingle stole fashion using 4" and 6' overlaps. Install using I" die. metal or plastic cap nails at 12' o.c. along 126' course and and laps an a single row 24" o.c. along middle line of the Field I.A.W. the product approval installation instructions. Stagger to layer using undercourse strip parallel to eave edge and cover with rule sheet. Overtab successive ahaets.bg 2V I.A.W.-product approval installation intitructit na. Siding Stucco on Block Soffit FLtt IG503.1 12" Tripple 4 Full-O-Vent Single Ka can LTD y nsta 1 using x PT batters attac a to wallueing 3Al" ia. with I" min. embedment into wall. Attach Soffit channel 3 wall using SPAN VINYL S-OFFi 0.091" die. x 1.5" T-nails at 12" o.c. per detail C in P.A. Install J channel to bottom of fascia usrn staples into soffit and same T-nails ± 55.6 PSF lot hom and in vallegs Der detaipAin P.A. (hroduct aDliroval) I have reviewed the above and approved it bg mg seal below. ( Architect or Engineer of Record ,