HomeMy WebLinkAbout610-21569 -D1-Density Tests Report 4-8-21nPACIHCA^
qEERVICES,
NGINEERING J� LLC
Client: Travis Gates
Date: 2/12/2021
FIELD DENSITY TEST REPORT
Project: 5105 Pinetree Dr. Fort Pierce FL
Report No.: 610-21569-D-1
Technician: Alfredo Calvo
Proctor Information
No.
Sample Location
Sample Description
Test Method
MDD (pcf)
OMC (%)
469-1
Existing
Brown sand w/ some rocks
AASHTO T 180
112.5
12.2
Project Specification
IDensity Test Method (ASTM D 6938)
98
% Density Requirement (Modified Proctor)
Test Mode
Direct Transmission (Troxler)
Test Results
General Location:
Building pad for garage
Test
No.
Location
Proctor
No.
Test
Depth
(in)
Elev. of
Test (ft)
Wet Density
(pcf)
Moisture
o
(/o)
Dry
Density
(pcf)
o
Comp. (/o)
Meet
Spec.?
1
21' N and 18' W of NE corner of House
469-1
12"
1 of 1
118.3
7.0
110.6
98.3
YES
2
32' N and 36' W of NE corner of House
469-1
12"
1 of 1
120.2
7.3
112.0
99.6
YES
3
39' N and 69' W of NE corner of House
469-1
12"
1 of 1
119.1
6.9
111.4
99.0
YES
Comments:
LC
32328
These test results apply only to the specific locations and materials noted and may not represent any other elevations or locations. This report may not be
reproduced, except in full, without the approval of Pacifica Engineering services, LLC. If a non-compliance appears on this report, to the extent that the
reported non-compliance impacts the project, the resolution is outside the PACIFICA scope of engagement.
Pacifica Engineering Services 1 1181 S Rogers Circle - Suite 3,1 Boca Raton, Florida 33487 1 561-693-8093
Florida Certification of Authorization License No. 32328
2/13/2021