HomeMy WebLinkAbout610-21569 -D1-Density Tests Report 4-8-21nPACIHCA^ qEERVICES, NGINEERING J� LLC Client: Travis Gates Date: 2/12/2021 FIELD DENSITY TEST REPORT Project: 5105 Pinetree Dr. Fort Pierce FL Report No.: 610-21569-D-1 Technician: Alfredo Calvo Proctor Information No. Sample Location Sample Description Test Method MDD (pcf) OMC (%) 469-1 Existing Brown sand w/ some rocks AASHTO T 180 112.5 12.2 Project Specification IDensity Test Method (ASTM D 6938) 98 % Density Requirement (Modified Proctor) Test Mode Direct Transmission (Troxler) Test Results General Location: Building pad for garage Test No. Location Proctor No. Test Depth (in) Elev. of Test (ft) Wet Density (pcf) Moisture o (/o) Dry Density (pcf) o Comp. (/o) Meet Spec.? 1 21' N and 18' W of NE corner of House 469-1 12" 1 of 1 118.3 7.0 110.6 98.3 YES 2 32' N and 36' W of NE corner of House 469-1 12" 1 of 1 120.2 7.3 112.0 99.6 YES 3 39' N and 69' W of NE corner of House 469-1 12" 1 of 1 119.1 6.9 111.4 99.0 YES Comments: LC 32328 These test results apply only to the specific locations and materials noted and may not represent any other elevations or locations. This report may not be reproduced, except in full, without the approval of Pacifica Engineering services, LLC. If a non-compliance appears on this report, to the extent that the reported non-compliance impacts the project, the resolution is outside the PACIFICA scope of engagement. Pacifica Engineering Services 1 1181 S Rogers Circle - Suite 3,1 Boca Raton, Florida 33487 1 561-693-8093 Florida Certification of Authorization License No. 32328 2/13/2021