Loading...
HomeMy WebLinkAboutAPPROVED, ROOF INFORMATION SHEETSLLLiL LamY*. ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code - Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A, B, C 1,2,3,4,5,6,7 Prescriptive BUR-RAS 150 A, B, C 2,4,5,6,7 Asphaltic Shingles A, B, D 1,2,4,5,6,7 Concrete or Clay Tile A, B, D, E 1,2,3,4,5,6,7 Metal Roofs A, B, D 1,2,3,4,5,6,7" Wood Shingles and Shakes A, B, D IA4,5,6,7 Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED As Applicable): 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation Form RooflnfoFeb21 Rev Feb 18, 2021 Section A (General Information) Master Permit No. Process No. Contractors Name: Storm Team Construction, Inc. License# CCC1332349 Job Address 207 E Arbor Ave ROOF CATEGORY Xow Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tiles ❑Asphaltic Shingles ❑ Metal Panel/Shingles ❑Wood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE_ ❑ New roof ❑ Repair ❑ Maintenance Reroofing ❑ Recovering ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) 883 Steep Sloped Roof Area (SF) Total (SF) _ Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. j wzj eagleview- :1. o Premium Report 12/15/2020 Total Line Lengths: Ridges = 86 ft Hips = Oft Valleys = 35 ft Rakes = 112 ft Eaves = 156 ft Flashing = 0 ft Step flashing = 10 ft Parapets _ 0 ft N w _ E Note: This diagram contains segment lengths (rounded to the nearest whole number) over 5.0 Feet In some cases segment labels have been removed for readability. Plus signs preface some numbers to avoid confusion when rotated (e.g. +6 and +9) O 2008-2020 Eagle Mew Technologies, Inc. and Pictome" International Corp. -All Rights Reserved - Protected by Ewopcan Patent Application No. 10162199.3 -covered by one or more cf V.S. Patent NOS. 8,07M36; 6,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: Certainteed LLC ProductApproval No.: FL2533-R24 Design Wind Pressures, From RAS 128 Or Calculations: Zone 1':-37 Zone 1: -64 Zone 2-84 Zone 3: -115 Max. Design Pressure, from the specific product approval system: -105.0 Deck: Type: Wood Gauge Thickness: Surfacing: NA Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1': 4 " cc @ Lap, # Rows-4--@ 4 " oo ' Zone 1. 4 " oc @ Lap, # Rows 4 @ 4' "oc Zone 2: 4 " oc @ Lap, # Rows 4 @ 4 "cc ' Zone 3:4 if oc @ Lap, # Rows 4' ® 4 n oc ' Number of Fasteners Per Insulation Board: Zone 1': na Zone 1: Zone 2: Zone 3 Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterf lashing, Coping, Etc.. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16.. Slope: 0/12 & 1/12 Anchor/Base Sheet & No. df Ply(s): na Anchor/Base Sheet Fastener/Bonding Material: Insulation Base Layer: na Base Insultation Size and Thickness: Base Insulation Fastener/Bonding Material: SBS-SA - Flintlastic SA C Top Insulation Layer: na PS -SA- Flintlastic SA I Top Insulation Size and Thickness: XF Flintlastic SA NailbaS Top Insulation Fastener/Bonding Material: 3 Wood Base Sheet(s) & No. of Ply(s): Flintlastic SA Nailbase(1) Base Sheet Fastener/Bonding Material: approved ring shank nails and tin caps Ply Sheet(s)' & No. of Ply(s): SBS-SA- Flintlastic SA Plybase(1) Ply Sheet Fastener/Bonding Material: Self - Adhered Top Ply: SBS-SA - Flintlastic SA Cap Top Ply Fastener/Bonding Material: Self - Adhered FT. Parapet Height )ase na FT. 10 Mean Roof Height