Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Product Approval
a �.,,...i�S.:,.,'a s.._.a'.-:.+..�e....�wv:2::.�_���"`. �-s ,,a.::re.� r'._ .. ., �. .� _, €. I•.s- ��H-�sr� BCIS Home i Log In User Registration Hot Topics Submit Surcharge Stats&Facts ' Publications ! Contact Us BCIS Site Map Links Search Florida , ��,, t a:A Product Approval , r .USER:Public User RECEIVED d:— Product Approval Menu>Product or Application Search>Application List>Application Detail x't i 1011 tile ' r � g" FL# FL14911-R12 Pgrmittir n�" nt Application Type Revision / �/„lI , Code Version 2020 &A=" E �® 1—® Application Status Approved CODE COMPLIANCE Comments Public comment;SMI I_ glI�7 lo s . �VC/6d � Y Archived OCC Product Manufacturer Silver Line Building Products Corp. Address/Phone/Email One Silverline Drive North Brunswick,NJ 08902 (800) 542-9118 Ext413596 luanne.harris@cornerstone-bb.com Authorized Signature Luanne Harris luanne.harris@cornerstone-bb.com Technical Representative Luanne Harris Address/Phone/Email One Silverline Drive North Brunswick,NJ 08902 (800) 542-9118 Ext413596 luanne.harris@cornerstone-bb.com Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Single Hung Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Hermes F. Norero, P.E. Evaluation Report Florida License PE-73778 Quality Assurance Entity Window and Door Manufacturers Association-QA Quality Assurance Contract Expiration Date 08/03/2021 Validated By Locke Bowden P.E. Validation Checklist- Hardcopy Received Certificate of Independence FL14911 R12 COI COI Silverline SS 2017-06-14.pdf Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA/101/I.S.2/A440 2008 AAMA/WDMA/CSA/101/I.S.2/A440 2011 ASTM E1886 2012 ASTM E1996 2017 ASTM E330 2002 TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/25/2020 Date Validated 10/25/2020 Date Pending FBC Approval 11/01/2020 Date Approved 12/15/2020 Summary of Products FL# Model,Number or Name Description 14911.1 V3 Series/50 Series(2000) Single-Hung Window Limits of Use—� Installation Instructions Approved for use in HVHZ: No FL14911 R12 II SWD017 SS 2020-10-21.pdf Approved for use outside HVHZ:Yes Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See Installation Instructions and Product Evaluation FL14911 R12 AE PER7259 SS 2020-10-21.pdf Report for allowable design pressures,sizes,installation Created by Independent Third Parry: Yes requirements and limits of use. 14911.2 Vl Series/50 Series(2111) Single-Hung Window Limits of Use W Installation Instructions Approved for use in HVHZ: No FL14911 R12 II SWD018 SS 2020-10-21.pdf Approved for use outside HVHZ:Yes Verified By: Hermes F. Norero, P.E. Florida P.E.73778 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See Installation Instructions and Product Evaluation FL14911 R12 AE PER7260 SS 2020-10-21.pdf Report for allowable design pressures,sizes,installation Created by Independent Third Party: Yes requirements and limits of use. 14911.3 V1 Series/50 Series(2200/2300) Single-Hung Window Limits of Use Installation Instructions Approved for use in HVHZ: No FL14911 R12 II SWD019 SS 2020-10-21.pdf Approved for use outside HVHZ:Yes Verified By: Hermes F. Norero, P.E. Florida P.E.73778 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See Installation Instructions and Product Evaluation FL14911 R12 AE PER7261 SS 2020-10-21.pdf Report for allowable design pressures,sizes,installation Created by Independent Third Party: Yes requirements and limits of use. 14911.4 V1 Series/70 Series(2127) Single-Hung Window Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL14911 R12 II SWD049 SS 2020-10-21.pdf Approved for use outside HVHZ:Yes Verified By: Hermes F. Norero,P.E. Florida P.E. 73778 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See Installation Instructions and Product Evaluation FL14911 R12 AE PER7262 SS 2020-10-21.pdf Report for allowable design pressures,sizes,installation Created by Independent Third Party: Yes requirements and limits of use. 14911.5 V1 Series/7-0 Series_(2127)_ ' Single-Hung Window Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL14911 R12 II SWD050 SS 2020-10-23.pdf Approved for use outside HVHZ:Yes Verified By: Hermes F. Norero,P.E. Florida P.E. 73778 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See Installation Instructions and Product Evaluation FL14911 R12 AE PER7263 SS 2020-10-21.pdf Report for allowable design pressures,sizes,installation Created by Independent Third Party:Yes requirements and limits of use. 14911.6 V1 Series/70 Series(2907/4907) Single-Hung Window Limits of Use Installation Instructions Approved for use in HVHZ: No FL14911 R12 II SWD0S3 SS 2020-10-21.pdf Approved for use outside HVHZ:Yes Verified By: Hermes F. Norero,P.E. Florida P.E. 73778 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See Installation Instructions and Product Evaluation FL14911 R12 AE PER7264 SS 2020-10-21.pdf Report for allowable design pressures,sizes,installation Created by Independent Third Party:Yes requirements and limits of use. Baek r�©mot Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395."Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: tKY � ® eClieck Credit Card Safe AMERICAN CRAFTSMAN WINDOWS AMERICAN CRAFTSMAN WINDOWS SILVER LINE WINDOWS AND DOORS SILVER LINE WINDOWS AND DOORS ONE SILVER LINE DRIVE NORTH BRUNSWICK,NJ 08902 PH:(888)741-0354 70 SERIES / V 1 SERIES / (2127) N z e SINGLE- HUNG WINDOWS "�- z a 1 1 wzc o � a (HVHZ)(IMPACT) ME o 3T�a �w� m GENERAL NOTES: 'W�^W s G j 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MAX OVERALL SIZE TABLE OF CONTENTS N Z a m Fn m DESIGN vi w MANUFACTURED TO COMPLY WITH THE CURRENT EDITION CONFIG. MISSILE o ri3 FLORIDA BUILDING CODE(FBC),INCLUDING HVHZ AND HAS WIDTH HEIGHT PRESSURE IMPACTRATING SHEET REVISION SHEET DESCRIPTION ^ i BEEN EVALUATED ACCORDING TO THE FOLLOWING: • TAS 201-94 52" 73" O/X +55/-60 PSF LMI/SMI 1 GENERAL NOTES&GLAZING DETAIL F • TAS 202-94 ~ a • TAS 203-94 2 - ELEVATION&ANCHOR LAYOUTS REMARKS • ASTM E330-02 3 - VERTICAL SECTIONS BY DATE • ASTM E1886.12 7TH FBC EDITION NUS 0/14/2 • ASTM E1996-17 4 - HORIZONTAL SECTIONS • AAMA/WDMA/CSA 101/I.S.2/A440-11 5 HORIZONTAL&VERTICAL SECTIONS,INSTALLATION NOTES& 2. ADEQUACY OF THE EXISTING STRUCTURAL REINFORCEMENT DETAILS CONCRETE/MASONRY,ZX FRAMING,AND METAL FRAMING THE iNnAaAnOx OFTa15OF5OUBw HEREIN AREGEN W C AS A MAIN WIND FORCE RESISTING SYSTEM CAPABLE OF AN—NOTRFFlFRACNALCONOMOMFORA9REEss�c WITHSTANDING AND TRANSFERRING APPLIED PRODUCT FRO MIHE REQUI ERER MEAN D LFa OHMN,�ua D LOADS TO THE FOUNDATION IS THE RESPONSIBILITY OF THE —INEFRORMdOwT PREFAREn3E3R ` OOOIMEN3s wRUiF lxls WdMENf. ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF INSTALLATION. eason:1 am approving this document 43/64"O.A.I.G.LAMINATED GLASS ate:2020.10 01 ZQQ?+02'00' 3. 1X AND 2X BUCKS(WHEN USED)SHALL BE DESIGNED AND CONSISTING OF: `�,�t 11f." ANCHOREDTO PROPERLY TRANSFER ALL LOADSTO THE 1/8"ANNEALED GLASS ,��� E O '%ice STRUCTURE.BUCK DESIGN AND INSTALLATION 15 THE 7/32"STEEL SPACER o *1 ;• f RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF 3/32"ANNEALED GLASS �,�•E •S••'•'P0s RECORD FOR THE PROJECT OF INSTALLATION. 0.090"SAFLEX PVB INTERLAYER BY (J 7 g EASTMAN CHEMICAL COMPANY 4. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE 3/32"ANNEALED GLASS -p GENERIC AND MAY NOT REFLECTACTUAL CONDITIONS FOR S A OF G: A SPECIFIC SITE.IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT IN EXTERIOR / INTERIOR �i� H • kFR�vN ��� C NON-HVHZ AREAS.IN HVHZ AREAS,ONE TIME PRODUCT �ldR I '77�Yebtd`vki c��\ APPROVAL TO BE OBTAINED FROM MIAMI-DADE RER OR I 398 E OANIA Bd OIVD.•33B 5 AHJ DANW BFAd,FL 33Ow '6 \ F9YE CERT.OF AU7HOR =N Nn M878 � S. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED STEELSPACER FL tJ: ON THIS PRODUCT IN AREAS REQUIRING IMPACT MIN.GLASS F L14911 RESISTANCE. 1/8"OR 3/32" J BITE 7/16" SETTING BLOCK I 6. WINDOW FRAME MATERIAL:PVC DOW 995 SEALANT DATE: 0''.23.18 TREMCO S700 SEALANT DWG.YY: CHKHFN ? 7. IN ACCORDANCE WITH THE CURRENT EDITION FBC,WOOD COMPONENTS SHALL HAVE BEEN PRESERVATIVE TREATED GLAZING DETAIL OR SHALL BE OF A DURABLE SPECIES AS DEFINED IN SCALE: NITS CHAPTER 23. NOTE: 8. GLASS MEETS THE REQUIREMENTSOFASTME1300 ALL GLAZING CONFIGURATIONS SHALL COMPLY WITH DWG•#: SWD050 SAFETY GLAZING REQUIREMENTS OUTLINED IN SHEET: Q GLASS CHARTS.SEE SHEET 1 FOR GLAZING DETAILS. CURRENT FBC AND ASTM E 1300 GLASS LOAD RESISTANCE. OF 5 AMERICAN CRAFTSMAN WINDOWS c SILVER LINE WINDOWS AND DOORS s ONE SILVER LINE DRIVE NORTH BRUNSWICK,NJ 08902 PH:(888)741-0354 C.1 MAX.O.A FRAME O Z $ <E WIDTH 52" \o� g agm MAX.D.L.O. 0 w?¢ mo al WIDTH 47.69" 3 a = o 3"MAX. 6"MAX. 6.25"MAX. z z l7 a A B O.C. FROM Imo-- I >>N a z g s _ 3 3 CORN RS CORNERS , j z OJ�0 3 �_ ca o m 1 NOTE: J— ALL FASTENERS ABOVE THE MEETING RAIL IN THE INTERIOR JAMB 6"MAX.� ��0�� TRACK MUST BE FLAT HEAD "0" ~ a MAX.D 3.5 "0" O.C. REMARKS EIDATE HEIGHT33.50" C4 7TH FBC EDITION 12.50"MAX. MAX.O.A FRAME D.C. HEIGHT 73" D T_ THEINSTAWTIONDETMt ER EEDHEREINARE GENERIC AND MAY NOT RENECEl1CT CON0R FORA.—C 'IERDECONDOIONBCRD)EINSTA lCNTODEWOE 4 FROM THEREONREMEMSDETNIEDHERNN,AEECENSED MAX.D.L.O. „X, X� E"o"o�c"uMRExrs ra0.—sEvmHRTMlfsmais—Miriunc HEIGHT 33.50" 3"MAX. 6.25"MAX. FROM FROM CORNERS CORNERS L !lLILIIIJ/J/ ���`` 77� 11 �i N .7 7 ELEVATION ANCHOR LAYOUT ANCHOR LAYOUT s a OF r SINGLE HUNG WINDOW NAIL FIN-SINGLE HUNG WINDOW THROUGH FRAME-SINGLE HUNG WINDOW �i 0.f O 1 SGAP N ►Ex0.R? \\\ IBB E OANU REACH BLVD.•)38 DANIA BER4KOE K ION 5 fOfE CFAT.Of AUDIDRRAl10N Na MBiO FL#. FL14911 DATE: 01.23.18 DWG.BY: c"KHFN P SCALE: NTS DWG.a: SW D050 SHEET: 2 0F 5 AMERICAN CRAFTSMAN WINDOWS a c SILVER LINE WINDOWS AND DOORS ONE SILVER LINE DRIVE NORTH BRUNSWICK,N1 08902 PH:(888)741-03S4 0 0 Um g 1 1 �3 9 In NzG z 0Q e a S SEE GLAZING SEE GLAZING .y tIl Z z DETAIL,SHEET 1 DETAIL,SHEET 1 Z; Ci CI N Z > m m i <a F s H a REMARKS BY DATE 7TH FBC EDITION NUS 0/14/2 x x q� EXTERIOR I INTERIOR EXTERIOR INTERIOR LL TNEIN—I—NUREJL9 DE9WBF0 HERON ARE GENERIC AND MAY NOT REFIER ARUAL CO NORIONS fOR A GR EOFlC y' y SRO WEREQUI NSLD INJT1,111,TO DE—TE a a EROMTXE REOUIBEMFNR OET.NFD XEREIN,A RRE . ENGLNFFA O0.AR[N00.CWTIETHOOOCUMENTORC ``ci ,`�111IIIIf/���'' ci i N .7 7 SEE GLAZING SEE GLAZING * S A OF DETAIL,SHEET 1 DETAIL,SHEET 1 398 E OIWN BFAOI BLVD.•J30 MT.OF AURIO0.PATION No.DS)0 a 0 FLp: FL14911 e DATE: 01.23.18 DWG. R cH BY: N NTS VERTICAL i ICAL SECTION g VER ICAL SECTION SCALE:g owG.a: SWDWD050 3 NAIL FIN 3 THRU FRAME SHEET: OF 5 I E AMERICAN CRAFTSMAN WINDOWS 8SILVER LINE WINDOWS AND DOORS c ONE SILVER LINE DRIVE NORTH BRUNSWICK,NJ 08902 PH:(888)741-0354 ^y ^ Z SECTION FOR INTERIOR SECTION FOR 3 BLOCK&TACKLE SEE GLAZING SEE GLAZING CONSTANT FORCE o— o a BALANCERS o\ DETAIL SHEET 1 DETAIL SHEET 1 `BALANCERS w?¢ z / � o N N �J 5 W = w9 o Ymm vs? = m w J i EXTERIOR a / r D.L.O. P! w F- 6 REMARKS BY DATE MAX.FRAME WIDTH 7TH FBC EDITION NUS 0/14/2 HORIZONTAL SECTION 4 UPPER SASH lxf REF— F DETAILB DESODND OM ARE GENEAID AND SITE O)NDI:E]ACNALEDNom➢NBNIR ASPEONc FF.x sm:mnom Dxs rausE iNnAUAnax]D DEvure i.-F. F RN1D10.EMENRDFTNIED XFAFIN,AuOBISED SEE GLAZING SEE GLAZING Exc�xEnME rswona usi.]mxR]x� sm:EEDflc (DETAIL SHEET 1 INTERIOR DETAIL SHEET 1 fl S A OF EXTERIOR �C) _ O IDP r D.L.O. ''�i��SSqpry 6m�J�vtG�� `'BVIL9°e"cI'IF 1AC 399 E DANIA BFACN I3 •33B OAN W BEACH,R., IN MAX.FRAME WIDTH FBRECER].OFAU]NOR[UipNo.R93]0 p HORIZONTAL SECTION FL11. FL14911 4 LOWER SASH DATE: 01.23.18 DWG.BY: cH HFN SCALE: NTS DWG.a: SWD050 SHEET: OF 5 MIN. SUBSTRATE 1/4 MAX' MIN.EMBEDMENT SHIM SPACE SUBSTRATE SUBSTRATE 3 EDGE DISTANCE BY OTHERS 3 BY OTHERS BY OTHERS AMERICAN CRAFTSMAN WINDOWS INTERIOR o SCREW IN THE INTERIOR SILVER LINE WINDOWS AND DOORS o CHANNEL F MIN. ONE SILVER LINE DRIVE MIN. EDGE DISTANCE W NORTH BRUNSWICK,NJ 08902 EMBEDMENT u PH:(BBB)741-0354 SCREW IN THE EXTERIOR W z CHANNEL a PERIMETER SEALANT 1/4"MAX BY OTHERS SHIM SPACE PERIMETER SEALANT 0 o z a E BY OTHERS 1/4"MAX. V 30 G on R EXTERIOR MIN. SHIM SPACE W z G -f 1-tj O EXTERIOR INTERIOR EMBEDMENT EXTERIOR INTERIOR E<3 a s Z o o i 3^3' A VERTICAL SECTION HORIZONTAL SECTION >�N ¢Z W "m m a �Z�WO� zsg=. 0 HORIZONTAL SECTION ;__�q~� 009` 5 THROUGH FRAME(HEAD) 5 THROUGH FRAME(JAMB) 5 NAIL FIN(HEAD) w J= HJa-¢o $ W' ....Z Z Z y CO V Z suBsrRAT �1/4" SPACE REINFORCEMENT DETAILS BY OTHERS 0.34" INTERIOR ,�� 0.83" ---.{I �0.87" ~ a —i 2 �'� I 4 0.13" REMARKS BY DATE W 0 77" � H �� 7TH FBC EDITION NUS o/1a/z o INTERIOR I ) —�{ 0.46" m EXTERIOR 0.061, 0.87" OAS" EXTERIOR 1 O LOCK RAIL TOP O LOCK ALUMWUNjNG RAIL O BOTTOMLALUMINUM RAIL&SASH THE INSTALUTDN DEEMS DES W BED HEREIN ME G ENEWC ALUMINUM MD MTND DE[ACNA mNOR1ON5 rORASPEDNC SlfElf SRF CONDIIIDN9 GU1f IHSTAWTIONSD DEMAIE I'M 3NEREDUIRENIENRDEEMEDHEREIN,AUMSED FNGI-Dq M[H13ERSIW3 PRE➢MESDE SPECIBC MIN.EDGE DOCVMENR FOR DSE WI111T115 ppL11MEM. DISTANCE �p HORIZONTAL SECTION VERTICAL SECTION 5 NAIL FIN(JAMB) S MEETING STILE INSTALLATION NOTES: ��� �•E•,S•'. �1 i ANCHOR SCHEDULE � O 5; 1. ONE(1)INSTALLATION ANCHOR IS REQUIRED AT EACH ANCHOR LOCATION SHOWN. METHOD SUBSTRATE ANCHOR SCHEDULE MIN EMBEDMENT MIN EDGE DISTANCE * N .7 e 2. THE NUMBER OF INSTALLATION ANCHORS DEPICTED IS THE MINIMUM NUMBER OF ANCHORS TO BE USED FOR PRODUCT INSTALLATION OF THE WOOD:MIN.SG=0.55 ae WOOD SCREW 1.5• 0.75" S A OF a MAXIMUM SIZE LISTED. PAN HEAD NNUNG FIN METAL:78 GAUGE Steel, Ife TEK SCREW 3THREADS MIN �j�0T O IDP':•���� 3. INSTALL INDIVIDUAL INSTALLATION ANCHORS WITHIN ATOLERANCE OF±1/21NCH THE DEPICTED LOCATION&SPACING IN THE ANCHOR LAYOUT MIN.Fy=33K51 PENETRATION BEYOND 0.50' DETAILS(I.E.,WITHOUT CONSIDERATION OF TOLERANCES).TOLERANCES ARE NOT CUMULATIVE FROM ONE INSTALLATION ANCHOR TO THE NEXT. META e AN HEAD IN 4. SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM(S).MAXIMUM ALLOWABLE SHIM STACKTO BE 3/81NCH.SHIM EXTERIOR CHANNEL 1.51 0.75• BtlRWttb G 39B E OAN43 BEACH R.5 33 •33e WHERE SPACE OF 1/161NCH OR GREATER OCCURS.SHIM EAOE 33aw S)SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. D,wu BWOOD:MIN.50=0.55 fePE CDR.DP AURIORRAiION Na.E95iB 410 FLAT HEAD IN THE S. FOR MASONRY OR CONCRETE OPENINGS,1X WOOD BUCK MAY BE USED(OPTIONAL AS LONG AS THE MINIMUM EMBEDMENT AND EDGE INTERIOR CHANNEL 1.5• 0.75' FL#: DISTANCE REQUIREMENTS ARE STILL MET WITHIN THE CORRESPONDING HOST SUBSTRATE.SEE GENERAL NOTE#3 ON SHEET 1 FOR MORE F L14911 EXTERIOR CHANNEL INFORMATION. 3THREADS MIN THROUGH FRAME A #1 PAN HEAD PENETRATIONL DATE:BEYOND 0.50• B 6. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDE WALL FINISHES,INCLUDING BUT NOT UMITEDTOSTUCCO,FOAM,BRICK VENEER,AND METAL:18 GAUGE SIeeI, 01.23.18 $" 3 SIDING. MIN.Fy=33KS1 # 3THREADS MIN °WG INTERIOR CHANNEL0 FLAT HEAD IN S PENETRATION BEYOND 0.50• HR `"KHFN 7. INSTALLATION ANCHORS AND ASSOCIATED HARDWARE MUST BE MADE OF CORROSION RESISTANT MATERIAL OR HAVE A CORROSION RESISTANT METAL COATING. 3116'MYTAPCON SCALE: NTS 8. FOR HOLLOW BLOCK AND GROUT FILLED BLOCK,DO NOT INSTALL INSTALLATION ANCHORS INTO MORTAR JOINTS.EDGE DISTANCE IS MEASURED CONCRETE:fc=3000P51 FLAT MEAD "'S' '75 DWG.II: SW D050 FROM FREE EDGE OF BLOCK OR EDGE OF MORTAR JOINT INTO FACE SHELL OF BLOCK. MASONRY:CIVIL per ASTM 3116'ITW TAPCON 1 25• 1 75' SHEET: 9. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS,AND ANCHORS C90 MIN.2000 PSI FLAT HEAD SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BYTHE ANCHOR MANUFACTURER. 10. FOR INSTALLATION ANCHORS ABOVE THE M EETING RAIL IN THE INTERIOR JAMB TRACK,USE FLAT HEAD ANCHORS. OF 5 398 East Dania Beach Blvd. BUILDING DROPS Suite338 A Perfect Solution in Every Drop! Dania Beach, FL 33004 Certificate of Authorization:29578 954.399.8478 PH 954.744.4738 FX contact@buildingdrops.com Product Evaluation Report of American Craftsman Windows Silver Line Windows and Doors 70 Series/V1 Series/ (2127) Single-Hung Windows (HVHZ)(IMPACT) for Florida Product Approval FL# FL14911 Report No. 726 Current Florida Building Code Method: 1—D(Engineering Evaluation) Category: Windows Sub—Category: Single Hung Product: 70 Series/V1 Series/(2127)Single-Hung Windows Material: PVC Product Dimensions: See Installation Instructions,SWDOSO Prepared for: Silver Line Windows and Doors One Silverline Dr. ',®�,►�►► e r,,,,��® North Brunswick, NJ 08902 Prepared by: :°•�-� E. s = 1pO Hermes F. Norero, P.E. Florida Professional Engineer#73778 S A ®° Date: 10/14/2020 Ir.O OF O IDP o®® Contents: Evaluation Report Pages 1—4 °�i� L Digitally signed by Hermes F Norero Hermes F. Norero, P.E. Reason:I am approving this document Date:2020.10.22 02:28:29+02'00' Florida P.E. NO.73778 BUILDING DROPS FL#: FL14911 A Perfect Solution in Every Drop! Date: 1 No: 726 Report No: 263 Certificate of Authorization:29578 Manufacturer: Silver Line Windows and Doors Product Category: Windows Product Sub-Category: Single Hung Compliance Method: State Product Approval Method (1)(d) Product Name: 70 Series/V1 Series/(2127)Single-Hung Windows (HVHZ)(IMPACT) Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL#73778)for Silver Line Windows and Doors based on Method 1d of the State of Florida Product Approval, Florida Department of Business and Professional Regulation-Florida Building Commission. Hermes F. Norero, P.E.does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the Current Florida Building Code. See Installation Instructions SWD050,signed and sealed by Hermes F. Norero, P.E. (FL#73778)for specific use parameters. Limits of Use: 1. This product has been evaluated and is in compliance with the Current Florida Building Code, including the"High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Chapter 16 of the Current Florida Building Code and does not require an impact resistant covering. 4. Site conditions that deviate from the details of Installation Instructions SWD050 require further engineering analysis by a licensed engineer or registered architect. 5. See Installation Instructions SWD050 for size and design pressure limitations. Hermes F. Norero, P.E. Florida P.E. No. 73778 Page 2 of 4 BUILDING DROPS FL#: FL14911 A Perfect Solution in Eve Dro Date: 10/14/20 ry p• Report No: 7263 Certificate of Authorization:29578 Quality Assurance Entity: The manufacturer has demonstrated compliance of products in accordance with the Florida Building Code for manufacturing under a Quality Assurance Entity through Window and Door Manufacturers Association(FBC Organization#QUA2515). Performance Standards: The product described herein has been evaluated per: • TAS 201-94 • TAS 202-94 • TAS 203-94 • ASTM E330-02 • ASTM E1886-12 • ASTM E1996-17 • AAMA/WDMA/CSA 101/I.S.2/A440-11 Referenced Data: 1. Product Testing performed by National Certified Testing Laboratories,Inc. (FBC Organization#TST1589) Report: Dated: NCTL110-16327-1 08/13/2013 Signed and Sealed by: Harold E. Rupp, FL PE No 15935,Sealed Date 02/06/18 NCTL110-16327-2 11/05/2013 NCTL110-16327-3 08/13/2013 11524.01-109-47 05/01/2018 11238.01-109-47 03/28/2022 2. Quality Assurance Window and Door Manufacturers Association (FBC Organization#: QUA2515) 3. Material Certification Miami-Dade County Notice of Acceptance Eastman Chemical Company(Previously Solutia) Saflex(Vanceva Composites) PVB Interlayer 4. PVC profiles meet requirements of WDMA/HallMark WD-61 in accordance with AAMA 303 Hermes F. Norero, P.E. Florida P.E. No.73778 Page 3 of 4 BUILDING DROPS FL#: FL14911 A Perfect Solution in Every Drop! Date: 10/14/20 Certificate of Authorization:29578 Report No: 7263 Installation: Refer to Installation Instructions(SWD050)for anchor spacing and more details of the installation requirements. Design Pressure: Refer to Installation Instructions(SWD050)for anchor spacing and more details of the installation requirements. Equivalence of Test Standards: Various test standards have been evaluated for differences in test methodology, if any, between tested editions of the test standards listed below and those editions referenced in the current Florida Building Code. Manufacturer has tested their products to the following test standard edition(s): 1) AAMA/WDMA/CSA 101/I.S.2/A440-08 2) ASTM E1886-05 3) ASTM E1996-06/09/12 Chapter 35 of the current Florida Building Code references the following editions of the above mentioned test standards: 1) AAMA/WDMA/CSA 101/I.S.2/A440-11 2) ASTM E1886-12 3) ASTM E1996-17 After review of the above mentioned referenced standards and editions, it has been found that no significant technical changes have been made to the test standards that would affect the results.All referenced standards have been found to be equivalent.All material test results meet minimum requirements of the current FBC including HVHZ provisions. Hermes F. Norero, P.E. Florida P.E. No. 73778 Page 4 of 4