Property Information Bu.lding Information
Owner: Robert Oneill Wind Zone: 170 MPH.
Address: 2 Universidad Lane Exposure Category: C
Port Saint Lucie,FL 34952 Minimum Building Dimension: 35 ft.
Mean Roof Height: 15 ft.
Risk Category: II
Design Pressure Calculations
Opening Location Device Device Max Positive Max Negative
Number Zone [:Device
idth(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
1 Int 62 65 7 35.3 -38.5
2 Int 34.75 40.5 7 37.8 -41.0
3 Int 34.75 40.5 7 37.8 -41.0
4 Int 82.5 65 7 34.6 -37.8
5 Int 62 57 7 35.6 -38.8
6 Int 62 57 7 35.6 -38.8
7 Int 46 65.5 7 36.0 -39.2
Prepared in accordance with:ASCE 7-16,Chapter 30. Wind Loads-Components and Cladding.7th E lition(2020)Florida Building Code.