HomeMy WebLinkAboutCOMPACTION TESTUES Project No:
Workorder No:
Report Date:
3360.1800067.0000
230156-1
04/09/2021
607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580
In-Place Density Test Report
Client:D.R. HORTON, INC. EAST FLORIDA DIVISION UES Technician:Johnnie Smith
1430 Culver Drive, NE
Palm Bay, FL 32907
Date Tested:04/08/2021
Project:CMT CREEKSIDE
Yorktown Drive & Okeechobee Road, Fort Pierce, IR County FL
Type of Test:
Area Tested:Lot 46 - 3306 Trinity Circle Field:ASTM D-6938 Nuclear Gauge Method
Material:Fill Laboratory:ASTM D1557 Modified Proctor
Reference Datum:0 = Top of Final Grade
The tests below meet the 95% minimum compaction requirement.
Test
No.Location of Test Range
Maximum
Density
(pcf)
Optimum
Moisture
(%)
Field Dry
Density
(pcf)
Field
Moisture
(%)
Soil
Compaction
(%)
Pass
or
Fail
1 Eastside Center, Tested Around
Perimeter of House
0-1 ft 118.6 10.8 114.3 10.6 96 Pass
2 Westside Center, Tested Around
Perimeter of House
0-1 ft 118.6 10.8 113.5 10.3 96 Pass
3 Southside Center, Tested Around
Perimeter of House
0-1 ft 118.6 10.8 115.1 10.7 97 Pass
4 Northside Center, Tested Around
Perimeter of House
0-1 ft 118.6 10.8 116.1 10.7 98 Pass
Remarks:Tested Around Perimeter of House
Permit: 20110180
Reviewed By
GFA International, Inc
FBPE Registry No.4930
Thomas Dominic Montano
Branch Manager
STATE OF FLORIDA
Professional Engineer No. 84146
This item has been digitally signed and sealed by Thomas Montano,
P.E. on the date adjacent to the seal. Printed copies of this
document are not considered signed and sealed and the signature
must be verified on any electronic copies.