Loading...
HomeMy WebLinkAboutHealth Dept a©o r. d( APPLICATION #:AP1468331 STATE OF FLORIDA. PERMIT #:56-SF-2039024 DEPARTMENT .OF HEALTH" DOCUMENT #:F1 1:579992 ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM t CONSTRUCTION. INSPECTION AND FINAL. APPROVAL DATE PAID:02I04/2021 •�"cao wt FEE PAID-95.00 RECEIPT #::56-PID-48.69672 APPLICANT.: Gregory Johnson AGENT:: Maurice Shazier(George&:Assoc, LLC) PROPERTY ADDRESS: 3705 Avenue t Fort Pierce, FL 34947 LOT: 12,3 BLOCK: A SUBDIVISION: Sumner Heights ID#: 2405-704-6001-000-7` CHECKED [Xj ITEMS:.ARE NOT IN COMPLIANCE WITH STATUTE OR RULE_AND ;MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ 1 [01] TANK SIZE ["1] 1090.00 [21 [ l (271 SURFACE WATER FT ( 1 [ail TANK MATERIAL Polypropylene [ j [2e:i .DITCHES FT ( 1 (031 OUTLET DEVICE [ l [293 PRIVATE. WELLS. FT [ .1 [041 MULTI-CHAMBERED ( ,Y N. 7 C 1 [30.1 PUBLIC" WELLS FT [ 1 [051 OUTLET FILTER PolylokPL-68 [ 1 (311 IRRIGATION WELLS 83 FT [ j [061 LEGEND 1. 70-143-11 DC4 2. ( l [321 POTABLE WATER 66 FT [ 1 [071 WATERTIGHT C ] [331 BUILDING FOUNDATIONS 7:5 FT [ ] (08j LEVEL [ 1 (341 PROPERTY LINES 8 FT [ ] (09] DEPTH TO LID [ j [351 OTHER FT DRAINFIELD INSTALLATION FILLED %MOUND SYSTEM 1. 1 1101 AREA. [il $75 [21 SOFT [ ], (361 DRAINFIELD COVER [ 1 till DISTRIBUTION BOX HEADER X [, J [371 SHOULDERS E 1 [121 NUMBER OF.DRAINLINES 1. 9i00. 2. ( 1 [381 SLOPES [ 1 [131 DRAINLnM SEPARATION [ ] [391 STABILIZATION 03123/2021 [ j [141 DRAINLINE SLOPE ( 1 [151' DEPTH OF COVER ADDITIONAL INFORMATION ( ] [16] ELEVATION ( ABOVE / BELOW IBM 4.00 ( `] [40`1 UNOBSTRUCTED AREA [ ] [171 SYSTEM LOCATION [ ] [411 STORMWATER. RUNOFF [ 1 (18'] DOSING PUMPS [ 'j (421 ALARMS C l [191 AGGREGATE SIZE C _l (43] MAINTENANCE AGREEMENT [ ] (20j AGGREGATE EXCESSIVE FINES C .1 (44:1 BUILDING AREA ( ] [211 AGGREGATE DEPTH [ l [451 LOCATION CONFORMS WITH SITE PLAN: FILL / EXCAVATION MATERIAL L. l [461 FINAL SITE GRADING C 1 [221 FILL AMOUNT C l E47j CONTRACTOR Horatio Van Lewis(A2Z Plumb 1. 1 [231 FILL TEXTURE [ 1 [481 OTHER INFICTRATOR.ARC 24 j [241 EXCAVATION DEPTH ABANDONMENT C 1 [251 AREA REPLACED [: 1 [49] TANK PUMPED ( 1. [261 REPLACEMENT MATERIAL [ 1 1501 TANK CRUSHED. &.FILLED Comments.. Comments are on. page 2:. CONSTRUCTION [ APPROVED St. Lucie CHD DATE: 02/08/2021 DISAPPROVED ) E ironmental Specialist ll rlaq IIn am`( V ( i ENTAL HEALTH) F.TNAL SYSTEM [ APPROVED: / DISAPPROVED , St.,Lucie CHD DATE:; 03123/2021 nvironmental Spec Ilstll NI ole M ttanez F orid Departmento('He (Explanation of Violations,on following page) DH4016, 08/09 (Obsoletes all previous editions -which.may not be used) Incorporated: ,64E-6.003, PAC Page 2 of 3 EH Database v 1.0.1 A171468M EI112039V4 i APPLIcATIoN #:AP1468331 STATE OF FLORIDA PERMIT #:56-SF-2039924 DEPARTMENT OF HEALTH DOCUMENT #:FI 1579992 ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAm:02/04/2021 FEE PAID:95.00 RECEIPT #:56-PID-4869672 Violation Number C mmen Comments The system is sized for 4 bedrooms with a maximum occupancy of 8 persons(2 per bedroom),for a total estimated flow of 400 gpd. <600 gal DT(add-a-bath)installed prior to ST regulated as plumbing. New ST and 3x4+3x5 long BED DF installed. No outlet filter installed at time of construction inspection. Insufficient DF area installed. Header pipe not level. Header pipe enters drainlines at bottom of endcap. Not installed per manufacturers installation instructions. Drainlines not tied together with a footer as required by rule. <24"space between drainlines as required for trench DF. less than 667 sgft of DF if installed as bed. Parts of drainlines pitched uphill. System installed by A to Z plumbing. System reinspected. No outlet filter and 510 sgft of DF installed as a BED. (6x4+2x5 long) Contractor notified by phone. Needs reinspection to verify trenchibed and adequate DF area. Needs outlet filter installed prior to final approval. Final inspection required for filled system and final site grading. Final DF area installed 675 sgft BED DF. System still has no outlet filter. All other violations corrected. Contractor advised that system is ok to cover. Needs final inspection for outlet filter,filled system,and final site grading. 3123/21 Final inspection approved.Emailed copy to building department. NMM DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1468331 E102039924