Planning & Development Services; Building & Code Regulation Division ` 2300 Virginia Ave, Rm 201; Fort Pierce, FL 34982 772-462-2165 Fax 772-462-6443 I FBC ENERGY CONSERVATION CODE R402.4.1.2 House Infiltration Test (Blower Door) Certification RECEIVED Prescriptive and Performance Method APR .i 6 �ntq Date: a� k.® - l� Permit #: (0 r Pe t. Lu9 D'"Punt Contractor: Job Address: 7�5;105 `i ' F5'o Lle- SLo CA�. Construction: ( New Construction - Complete ( ) Existing -After Addition I House Infiltration Test Results SLC Climate Zone 2 / CFM (50) _ �®,� i 239 Test Date: 4PLi / <> A% Volume = �(o© c� �t ACH (50) = CFM (50) x 60 / Volume = "`[�2 Meth Ica/ Ventilation required less than 3 ACH Passing results must be & ACH (50) or'less Pass ( ) Fail i FBC, Energy R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Texting shall be conducted with a blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after,creation of all penetrations of the building thermal envelope. I FBC, Residential R303.4 Mechanical ventilation. Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.. Testing CompanyQ[`�f Company Name: �� Address: -1-' `© &JeU04SQ.� iav1c11��Qr I hereby certify that the above House requirements in accordance with.Sec' Signature: Printed Name: License/Certification #: results demonstrate compliance with FBC Energy Conservation .4.1.2 Climate Zone 2. rci'ii �'O'm Date: ®c ' Contractor: ; Planning & Development Services Building & Code Regulation Division 2300 Virginia Ave, Rm 201 RECEIVED Fort Pierce, FL 34982 772462-2165 Fax 772-462-6443 APR .18 ?m# FBC ENERGY CONSERVATION CODE Permitting Duct Sealing Certification De St. Lucie Coon mern Prescriptive and Performance Method tY Permit#: , (�`� ®Z�'1 Lot#: Arlrlroer k<Z� ct le—, 0+ v'l & _L Construction: ost Construction Test ❑ Rough -in Test Test Conditions: Date: 0 Floor Area (ft2): Time: ( lO l}m Primary Location of Supply Ductwork't'l Indoor Temperature (F): '%`7' Primary Location of Return Ductwork Outdoor Temperature (F): Total Leakage Test (Outside) Duct Leakage: ❑ D cult ropleak Free ❑ Proposed On = Test Pressure: (Pa) Baseline Duct Pressure (optional) (Pa) Duct Press. (Pa) Flow Ring Fan Press Flow (cfm) Results: ass ❑ Fail Installe Pa !� ® Total Leakage (cfm): Total Leakage per 100 sgft: CFM25 x 100 divided by the CFA = Duct Leakage CFM/100 sqft. Testing Company Ny a - Company Name:' 1�� Address: —i550,G`f`pP hereby ceq.2.2 ab DQealinage'results demonstrate compliance with 5t' Edition FBC Energy Conservation requirements in accordance with Section R4 Signature: Printed Name: —1 A Qt �Uense/Certificate #: AP P KU V 6. hib.