Loading...
HomeMy WebLinkAboutBuilding Plans2"x2" GALVANIZED WASHER WITH Y2- NUT EYES BOLTED TOGETHER WITHY2"x2" BOLT & NUT WITH (2) 2"x2" GALVANIZED WASHERS (2,000LB SHEAR CAPACITI, Y"x 3" (400 LAB)) CONCRETE WEDGE ANCHOR (SEE TABLE 1 FOR SPACING) Q' NOTCH OR COUNTERSINK BOLT 7 2 THREA1) d,.ROO rY OPTI-O .'L�FOR-"HIGH SET" THRU 2"x4" BOTTOM PLATE 1/2" THREADED ROD 2"x2" GALVANIZED WASHER 1/2"x5" (400 LB) CONCRETE OPTIONAL FOR "HIGH SET" WITH y" NUT -� WEDGE ANCHOR INTO SLAB T� THRU 2"x4" P.T. BOTTOM PLATE 1/2"COUPLER ���� :"%'•%��-��w� (SEE TABLE 1 FOR SPACING) 2"x4" BOTTOM PLATE NAILED co .f_ . 4" y MIN. TO 2"x6" P.T. BASE w 1/2"x12" FORGED EYEBOLT X 1�.%s'x i • _ 4" MIN. C NCRETE SLAB BY OTHERS EYES BOLTED TOGETHER W/ 1/2"x2" GRADE �SIMPSON A-24 THROUGH LOCAL CODES BOLT &NUT WITH (2)2"x2" GALVANIZED TYPE I, II, III, OR IV PAD WITH CONCRETE SLAB BY OTHERS z C. OR EQUA1 AND JURISDICTION WASHERS (2,000LB SHEAR CAPACITY) BLOCKING AS REQUIRE >�yx THROUGH LOCAL CODES (SEE TABLE 3) �� ;y„•� AND JURISDICTION 30" EARTH AUGER ANCHOR :6 3D.WITH'SKI, ; SHED WITH'NO FLOOR' OPTION' (SEE TABLE 4 FOR SPACING) ;ED T.O%G�ONCRETE ANCHORED TO CONCRETE SHED WITH SKID TO PAD OR BLOCKING SETUP AND INSTALLATION OF SINGLE WIDE SHED 1. BUILDING IS PLACED IN REQUESTED LOCATION ON SCHEDULE 40 PVC TO ALLOW FOR MOVEMENT TO PLUM OR SQUARE UNIT TO HOUSE, FENCE, PROPERTY LINE, ETC. 2. ONCE UNIT IS SQUARE AND THE HIGH SPOT OF THE GROUND IS ESTABLISHED, THE BUILDING IS BLOCKED ON THE HIGH SPOT OF THE GROUND AND LEVELED. THE OTHER END OF THE BUILDING IS BROUGHT UP TO LEVEL AND BLOCKED. THEN THE CENTER OF THE BUILDING IS SUPPORTED TO LEVEL, MORE BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3). 3. AFTER THE BUILDING IS LEVEL, MORE BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3). 4. ANCHOR PLACEMENT IS ESTABLISHED BY THE WIDTH OF THE BUILDING, HOLES ARE DRILLED THRU THE 2"X4 BOTTOM PLATE WITH A 1/2" AUGER BIT. 1/2" EYEBOLT OR OPTIONAL 1/2" THREADED ROD (FOR A "HIGH SET") IS SECURED THRU THE HOLE. 5. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS. 6. IF THE UNIT HAS A FLOOR, EITHER A HOLE IS DUG FOR THE 30" AUGER ANCHOR AND BACKFILLED AND SECURED AS PER THE DETAIL OR A 1/2" HOLE IS DRILLED INTO THE CONCRETE 1-112" OFF THE RIM JOIST. THE EYEBOLT IS FASTENED THRU THE BOTTOM PLATE AND A SIMPSON A-24 (OR EQUAL) IS SECURED TO THE CONCRETE WITH A 1/2" WEDGE ANCHOR. 7. IF THE UNIT A'NO FLOOR OPTION, ANCHOR WITH 1/2"X5" WEDGE ANCHOR THRU THE 2"x4" BOTTOM PLATE. z a O U z 9 co w 0 1n z a It s O 0 N 0 N r, a 0 U TABLE 1 ANCHORING TO CONCRETE SHED WIDTH UPLIFT (PLF) ANCHOR SPAC'G 20'-0" 400 T-6" 13'-8" 280 T-6" 1 V-8" 240 T-6" 10'-0" 200 T-6" 8'-0. 160 T-6" 6'-0" 120 T-6" SETUP AND INSTALLATION OF DOUBLE WIDE SHED 1. BUILDING IS PLACED IN REQUESTED LOCATION. THE FIRST SECTION OF THE DOUBLE WIDE IS PLACED ON THE HIGHEST LOCATION OF GROUND AND IS LEVELED UP. 2. BLOCKS ARE THEN PLACED AT THE END, CENTER, AND OTHER END TO LEVEL. ONCE THE BUILDING IS LEVEL, BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3). 3. THE NEXT SECTION OF THE SHED IS BACKED INTO PLACE AND UNLOADED PARALLEL WITH THE FIRST SECTION. THE TWO SECTIONS ARE CONNECTED AT THE LOWER CORNER WITH (1) J"x4j" BOLT AND NUT. THE SECOND SECTION IS THEN LEVELED AND THE OTHER BOLT HOLES ARE LINED UP AND BOLTED SECURE. THE REST OF THE BLOCKING IS THEN COMPLETED. THIS PROCEDURE IS REPEATED FOR MULTIPLE SECTION SHEDS UNTIL ALL SECTIONS ARE IN PLACE. 4, GROUND ANCHORS ARE THEN ADDED (SEE TABLE 4B). 30" AUGER ANCHOR 5. ONCE THE BUILDING IS PROPERLY BLOCKED AND BOLTED TOGETHER, THE SUPPORT BRACING IS (4725 LB) REMOVED. INSTALLED PER MFRS 6. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO INSTRUCTIONS. EYELET AT FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS. MAXIMUM OF 6" ABOVE GRADE TABLE 2 SKID RUNNER SPACING' SHED WIDTH X1 X2 X3 13'-8" 1'-10? 1'-1 q 1'-104" 11'-8" 2'-8" 6'-4" 10'-0" V-7" 6'-10" 81-0" 9" 6'-6" 6'-0" 10" 51" VALUES ARE FROM END OF JOIST TO CENTERS OF (2) 4"X4" NOTES: 1. HOLLOW OR SOLID CONCRETE BLOCKS (8"x8"xl6") MAY BE STACKED ON PADS FOR HIGH SETS UP TO 48" WITHOUT REINFORCING. 2. ABS PADS REQUIRED ON 11'-8" AND 13'-8" WIDE SHEDS ONLY. TABLE 3A PAD TYPES TYPE PAD DIMS MAX LOAD" MATERIAL I 2"x8"X16" 1778 LBS CEMENT AND SAND MIX II 4"x8"X16" 3500 LBS -CONC. BLOCK QUALI CEMENT AND SAND MIX III 16"X16" 3950 LBS ABS PLASTIC PADS IV 8"X8"X16" 1900 LBS CONC.BLOCKA I CEMENT AND SAND MIX BASED ON 2000 PSF SOIL BEARING CAPACITY (2000 PSF IS TYPICAL) NOTES: 1. HOLLOW OR SOLID CONCRETE BLOCKS (8"x8"x16") MAY BE STACKED ON PADS FOR HIGH SETS UP TO 48" WITHOUT REINFORCING. 2. ABS PADS REQUIRED ON 1 V-8" AND 13'-6" WIDE SHEDS ONLY. TABLE 3 SUPPORT FOOTING PAD SPACING FOR RUNNER BLOCKING FOR SINGLE & DOUBLE WIDE SHEDS SHED DESCRIPTION PAD MAXIMUM LOAD AND PAD TYPE SHED WIDTH TYPE LW* (PLF) END PAD MAX. SPACING END PAD SIDE RUNNER PAD TYPE INTERIOR PAD SIDE RUNNER PAD TYPE 13'-8" SW/DW 4.151332 0" TO 6" 6-0" 1936 LB 1, II, III, OR IV 1879LB I, 11, III, OR IV 11'-8" SW/DW 6.001480 0" TO 6" 6'-0' 2558 LB I, II, 111, OR IV 2558LB I, II, III, OR IV 10'-0" SW/DW 5.00/400 0" TO 6" 6'-0" 2400 LB 1, II, III, OR IV 2400LB I, II, III, OR IV 8'-0" SW 4.00/320 0" TO 6" V-0" 2029 LB I, II, 111, OR IV j 2133LB j I, II, 111, OR IV 6-0" SW 3.001240 0" TO 6" 6'-0" 1658 LB I, 11, III, OR IV 1866LB 1 1, II, III, OR IV LOAD WIDTH OF UPLIFT ON RUNNER NOTES: 1. PAD SPACING IS END TO CENTER OF PAD 2. PADS OTHER THAN END PADS SPACING IS CENTER TO CENTER 3. USE SAME MAXIMUM SPACING FOR INTERIOR SPACING CODE INFORMATION CODE VERSION FBCy7THEDITION .(2020) AISGELZ-'_16 MANUFACTURER SUPERIOR SHEDS BUILDING TYPE MANUF. SHED CONSTRUCTION V-B CODE VERSION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY STORAGE ALLOWABLE NO. OF STORIES 1 BASIC WIND SPEED 180 MPH (VULT) EXPOSURE C ENCLOSURE ENCLOSED INTERNAL PRESSURE COEF. +/- 0.18 IMPORTANCE FACTOR 1.15 ROOF DEAD LOAD 10 PSF ROOF LIVE LOAD 20 PSF OR 300LBS FLOOR DEAD LOAD 8 PSF FLOOR LIVE LOAD 75 PSF / 125 PSF "R" RATING (WALL, FLOOR, ROOF) N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO SQUARE FOOTAGE LESS THAN 7 SHED STRUCTURE FOR: SUPERIOR SHEDS (877) 439-7433 2323 S. VOLUSIA AVE. ORANGE CITY, FL '\ \\ .{ y.. i MODULAR PLANS DESIGN, CO. GENERAL NOTES & SPECIFICATIONS FOR AUGER ANCHORS 1. BUILDING ANCHORS SHALL BE "MOBILE HOME" TYPE HP-1 SINGLE HELIX EYE AUGER ANCHORS BY HOME PRIDE OF BRISTOL, VA. OR EQUIVALENT. AVERAGE HOLDING STRENGTH IS NOT LESS THAN 4,725 LBS. 2. ANCHORING SYSTEM TO GROUND PER LOCAL BUILDING CODE (BY DEALER). LOCATE ANCHORS PER TABLE 4A OR 4B. 3. THREADED. ROD WITH EYEBOLTS SHALL BE PLACED THRU THE BOTTOM PLATE (FLOOR SYSTEM) AND ATTACHED TO ANCHOR. THESE CAN BE EXTENDED WITH THREADED ROD (OR STRAPS WITH EQUAL OR GREATER STRENGTH) FOR ELEVATED PORTIONS OF SHEDS ON LEVELING BLOCKS. TABLE 4A 30" AUGER ANCHOR SPACING - SINGLE WIDE SHED WIDTH LW* (PLF) END ANCHOR" MAX. INTERIOR SPACING" 13'-8" 7.00 243 0'-0" TO T-0" 10'-0" 11'-8" w 6.00. a 208" -0'!0 .T0,3 -0„- 10'-0" 5.00 174 0'-0" TO 3'-0" 8'-0" 4.00 138 0'-0" TO T-0" 10'-0" r77�-O---T 3.00 104 0'-0- TO T-0" 10'-0" TABLE 4B 30" AUGER ANCHOR SPACING - DOUBLE WIDE SHED WIDTH LW* PLIFT (PLF) END ANCHOR" MAX. INTERIOR SPACING 20'-0" 10.00 400 1 0'-0" TO T-0" 1 5'-0" LOAD WIDTH UPLIFT ON RUNNER LOCATION FROM END WALL OF AUGER ANCHOR - --- "' MAXIMUM SPACING BETWEEN ANCHORS NOTES 1. ANCHOR SPACING IS DESIGNED AS PER ASCE-7 2. ALL MEASUREMENTS ARE CENTER -TO -CENTER 3. THE MINIMUM NUMBER F ANCHORS PER SHED IS (4). (1) ANCHOR PER EACH CORNER. ADDITIONAL INTERIOR ANCHORS ARE REQUIRED IF SPACING IS MORE THAN 10'-0" BETWEEN ANCHORS. 4. ANCHORS SHALL BE ON SIDE WALLS EXCEPT WHEN THE SHED IS PLACED NEXT TO AN EXISTING BUILDING: IN WHICH ANCHORS CAN BE PLACED ON THE END WALLS AS CLOSE TO THE SIDE AS POSSIBLE. GENERAL NOTES: ,RBe 1. FOUNDATION PLANS ARE NOT PART OF THIS ;:��.. 6 :�so PLAN SET AND ARE GOVERNED BY LOCAL JURISDICTION. 2. THIS BUILDING IS EXEMPT FROM THE FBC ENERGY CONSERVATION CODE PER SECTION Fss ONAL'�NG`. 1015.22 mu. 3. REFER TO TIE -DOWN DETAILS FOR PROPER Digitally I signed b g Y g INSTALLATION REQUIREMENTS TO MEET CODE. Y Julio Orbegoso Date: 2021.02.01 16:42:51-05'00' MODULAR PLANS DESIGN, �1 1 e 202 DORM DRIVE.. SUITE 105 OFFICE 863.688.1054 LAMAND, FLORIDA FAX 863.688.7118 33813 COLECMODULARPLANSCO.COM If COMPLIANCk: ICIE COUNTY UOCC4q1%'4 DATE: 01-22-2021 DRAWN: R.L.G. JOB: SS FOUNDATION SHEET NO. z Z a 0 U z U) w rn z 3 a 5 ❑ 0 0 N N H EL 0 U O NOT APPROVED FOR HVHZ STRUCTURAL LOAD LIMITATIONS WIND LOAD CRITERIA 1. 132 Vasd/170 Vult WIND SPEED (MPH) 2. 1 RISK CATEGORY 3. II BUILDING CATEGORY 4. ENCLOSED ENCLOSURE CLASSIFICATION 5. GCpI = 0.18 INTERNAL PRESSURE COEFFICIENT 5. C EXPOSURE FACTOR 6. 0.85 WIND DIRECTIONALITY FACTOR (Kd) 7. 0.85 GUST RESPONSE FACTOR (Gh) 8. Pr = -93.0 PSF MAIN FRAME STRUCTURE OVERTURNING LOAD 9. COMPONENT & CLADDING LOAD (ROOF) Pr = ZONE 1: -35.63 PSF, ZONE 2: -35.63 PSF, ZONE 1-65.26 PSF (WALL) PW = ZONE 4: -39.14 PSF, ZONE 5: -46.89 PSF 10. THIS BUILDING IS NOT DESIGNED FOR PLACEMENT ON THE UPPER HALF OF A HILL OR ESCARPMENT EXCEEDING 15 FEET IN HEIGHT. SEISMIC LOAD: N/A FLOOD LOAD: THIS BUILDING IS NOT DESIGNED TO BE SUBMERGED OR SUBJECTED TO WAVE ACTION WHEN LOCATED IN A FLOOD PRONE OR ZONE AREA. FINISH FLOOR ELEVATION MUST BE LOCATED ABOVE THE BUILDING SITE FLOOD PLANE LEVEL. SHEDS LOCATED IN FLOOD HAZARD AREAS MUST COMPLY WITH THE LOCAL FLOOD ZONE REGULATIONS. DRAWING INDEX C1 COVER SHEET Al FLOOR PLAN A2 SIDEWALL FRAMING A3 FLOOR FRAMING A4 ROOF FRAMING A5 CROSS SECTIONS A6 ENDWALL FRAMING A7 SCHEDULES *** Please note: Any questions regarding local permitting should be directed to the Manufacturer. The Manufacturer's contact information can be found in the title block of the plans. 2323 S. VOLUSIA AVENUE ORANGE CITY, FLORIDA 32763 (877) 439-7433 GENERALNOTES 1. FOUNDATION PLANS ARE NOT PARTOF THIS PLAN SETAND ARE GOVERNEDBY LOCAL JURISDICTION. 2. BUILDINGS ARE APPROVED FOR RESIDENTIAL LAWN STORAGEONLY 3. THIS BUILDING IS EXEMPT FROM THE FECC PERSECTIONS R101.4.2.4, R402.1. 4. REFER TO TIE DOWN DETAILS FOR PROPER INSTALLATION REQUIREMENTS TO MEETCODE. 5. ALL LUMBER FOR CONSTRUCTION WILL BE #2 SYP EXCEPT AS NOTED. 6. GUTTERS SHALL BE SITE INSTALLED PERTHE LOCAL AUTHORITYHAVING JURISDICTION AND PERMITTING REQUIREMENTS. 7. ALL WINDOWSAND DOORS TO MEETTHE MINIMUM SPECIFICATIONSPERTHE APPROVED PLANS AND THE FLORIDA BUILDING CODE. 8. IN ACCORDANCEWITH FBC 1609.1.2, "STORAGE SHEDSTHATARE NOT DESIGNED FOR HUMAN HABITATION AND THAT HAVE A FLOORAREAOF 720 SQUARE FEETOR LESS ARE NOT REQUIREDTO COMPLY WITH THE MAN DATORYWINDBORNEDEBRIS IMPACT STANDARDS OF THIS CODE". 9. IN ACCORDANCE WITH FBC 1010.1.1, EXCEPTION(10.) BUILDINGS THATARE400 SQ-FTOR LESS AND THAT ARE INTENDED FOR USE IN CONJUNCTION WITH ONE -AND TWO-FAMILY RESIDENCES ARE NOT SUBJECTTO THE DOOR HEIGHTAND WIDTH REQUIREMENTSOF THIS CODE. STRUCTURES400 SQ-FTOR MORE SHALL HAVEAN 80" MINIMUM DOOR. 10. IN ACCORDANCE WITH FLORIDASTATUTE553.80 (1)D, LAWN STORAGE BUILDINGS AND STORAGESHEDS BEARING THE INSIGNIA OF APPROVALOF THE DEPARTMENT ARE NOT SUBJECTTO 553.842 (FLORIDA PRODUCTAPPROVALS) BUT SHALL MEET THE DESIGN WIND LOAD REQUIREMENTS OF THE 2020 FBC 7TH EDITION. 11. FLAT METAL STRAPS CAN BE BENTAROUND STRUCTURAL MEMBERS OF WALL STUDS, TRUSSES, CHORDS, ETC. TO HELP SECURE THESE MEMBERS, PROVIDED THAT THE ADDED BEND DOES NOT INTERFERE WITH ANY OF THE EXISTING BREAKS/BENDS IN THE STRAP. 12. AS PER FBC SECTION 1626.1 EXCEPTION(F): STORAGE SHEDSTHATARE NOT DESIGNED FOR HUMAN HABITATION AND THAT HAVE A FLOORAREAOF LESSTHAN 720 SQUARE FEETOR LESSARE NOT REQUIRED TO COMPLY WITH THE MANDATORY WINDBORNE DEBRIS IMPACT STANDARDS OF THIS CODE. 13. COMPONENTS/CLADDING ARE IN COMPLIANCE WITH THE 2020 FBC 7TH EDITION. 14. SHEDS LOCATED IN FLOOD HAZARD AREAS MUST COMPLY WITH THE LOCAL FLOOD ZONE REGULATIONS. 15. IF A WALL IS FRAMED FOR FUTURE HVAC UNITS THAT SHALL BE APPROVED BY THE AHJ AND SHALL COMPLY WITH LOCAL REQUIREMENTS FOR PERMITTING. 16. WINDOWSAND DOORS INSTALLED BY THE CUSTOMER THAT SHALL BE APPROVED BY THE AHJ AND SHALL COMPLY WITH LOCAL REQUIREMENTS FOR PERMITTING. 17. HVHZ COMPONENTS FORSHEDS REQUIRE THAT INSTALLATION PER MANUFACTURER'S INSTRUCTIONS. DESIGN PRESSURES DOORS: +1- 20 PSF WINDOWS: +/-40.10 PSF r� NOT APPROVED FOR HVHZ�� MODULAR PLANS DESIGN, CO. LISTING AGENCY APPROVAL: TOP LINE ENGINEERING, LLC. BUILDING CODE RESIDENTIAL CODE ELECTRICAL CODE BUILDING TYPE MANUFACTURER AGENCY AGENCY PLAN NUMBER CONSTRUCTION TYPE FIRE PROTECTION FIRE SUPPRESSION SYSTEM OCCUPANCY ALLOWABLE # OF STORIES WIND VELOCITY FIRE RATING OF EXTERIOR WALLS FLOOR LIVE LOAD - STANDARD FLOOR LIVE LOAD - OPTIONAL FLOOR DEAD LOAD ROOF LIVE LOAD ROOF DEAD LOAD "R" RATING OF FLOOR, WALL, &ROOF MODULES PER BUILDING SQUARE FOOTAGE HURRICANE PROTECTION USAGE HURRICANE SHELTER USAGE HVHZ APPROVED FBC, 7TH EDITION (2020) FRBC, 7TH EDITION (2020) 2017 NATIONAL ELECTRICAL CODE RESIDENTIAL LAWN STORAGE SHED SUPERIOR SHEDS, LLC TOP LINE ENGINEERING, LLC BUNG-20 V- B NO NO UTILITY 1 170 MPH, EXPOSURE C 0 75 PSF 125 PSF 10 PSF 30 PSF 10 PSF N/A 1 719 SQ/FT MAX. NO NO NO TOP LINE ENGINEERING, LLC _TOP LINE ENGINEERING, LLC - STRUCTURAL ENGINEERS v William E. Neary, III SMP-51, SIVII-79, ICC 5185040 10649 Oakview Pointe Terrace Gotha, Florida 34734 BUNGALOW SHED MODULAR PLANS DESIGN, CO. 202 DORIS DRIVE.. SUITE 105 OFFICE: 863.688.1054 LAKELAND. FLORIDA FAX:-68'.7118 33813 COLE@MODUTARPLANSCO.COM CONSULTING ENGINEER JULIO ORBEGOSO FLORIDA PE LICENSE #38769 2021-01-20 TOP LINE ENGINEERING APPROVAL PLAN # BUNG-20 *** NOT HVHZ APPROVED CEILING J-BOX SINGLE POLE NtUIKAL G.F.I. SWITCH OUTLET ELECTRICAL NOTES & OPTIONS: - AS PER NEX ARTICLE 330.30(B) SECURING OF MC TYPE CABLE. UNLESS OTHERWISE PROVIDED, CABLES SHALL BE SECURED AT INTERVALS NOT EXCEEDING 6FT. CABLES CONTAINING FOUR OR FEWER CONDUCTORS SIZED NO LARGER THAN 10 AWG SHALL BE SECURED WITHIN 12 IN. OF EVERY BOX, CABINET, FITTING, OR OTHER CABLE TERMINATION. - ALL WIRING SHALL BE 14 GAUGE 3-WIRE MC CABLE. - ENCASE IN ALL METAL BOXES. MAXIMUM NO. OF OUTLETS: 7 MAXIMUM NO. OF LIGHTS: 8 ELECTRICAL WIRING DIAGRAM SCALE: NOT TO SCALE NOTE: 1. MIN. GRADE STUDS: 2"X4" STUDS TO BE Fb = 1200 PSI OR GREATER 2. MIN. ROOF SHEATHING: 29GA CORRUGATED METAL 3. MIN. FLOOR SHEATHING: %4' PLYWOOD 4. MIN. WALL SHEATHING: D4 ALUMINUM SIDING NOTE: 23" SECTIONS OF 29GA CORRUGATED METAL SIDING FASTENED W/ %4' #8 HEX WASHER SELF DRILLING SCREWS @ 4" ON EDGE & 6" IN FIELD SHED OVERALL LENGTH (MAX. 40'-0") NOTE: SHOWN IS THE 10'-0" x 20'-0" W/ 64' PORCH OPTION ''""[[�'' TA _� .LJ TO ST UCTURALNEER`N GLLC Y William E. Neary, III SMP-51, SMI-79, ICC 5185040 10649 Oakview Pointe Terrace Gotha, Florida 34734 FLOOR PLAN SCALE: 3/8" = V-0" NOTE: SHEDS TO HAVE A MAXIMUM OF 5 DOORS AND 10 WINDOWS CONSULTING ENGINEER JULIO ORBEGOSO FLORIDA BUNGALOW SHED PE LICENSE #38769 MODULAR STRUCTURE FOR: SUPERIOR SHEDS (877)439-7433 2323 S. VOLUSIA AVE. ORANGE CITY, FL 32763 MODULAR PLANS DESIGN, CO. MODULAR2ERO FL SUITE 106 OFF6. .0 8j�LANoR,AOFFICE-- PLANS DESIGN, CO. 33813 COLS®MODULARPLANSCO.COM I / iuliO-� Orbego ORe •. p No. 38769 9 �' 0 i�Q� •. STATE OF F<DRLDP..'G��: �ONAL E`, 09:03:5 `` -05' 2021-01-20 TOP LINE ENGINEERING APPROVAL PLAN # BUNG-20 *** NOT HVH7 APPROVFI) ENDWALL DOOR & WINDOW 6'-0" WIDE OR LESS SCALE: NTS 2"X4" SYP#2 STUDS @ 24" O.C. 2"X4"X60" SYP#2 SISTER STL ATTACHED W/ 10d COMMON NAILS @ 4" O.C. 3"X6" MITEK MT20 OR EQUIVALENT 2"X4" SYP#2 ROOF TRUSSES @ 24" O.C. 2"X4" SYP #2 BOTTOM gLAjIf -FI I I in I I[ / VARIES I 1-1112" MAX. \-- 4"X4" SYP #2 HEADER I I I L SEE HERE DETAIL 2"X4" SYP #2 JACK STUD _ 0 In U) 2"X4"SYP #2 KING STUD W Q > 4"M" HEADER DETAIL SCALE: NTS -- -- JD DETAIL C6" MITEK MT20 IR EQUIVALENT "BETWEEN NT IS SECURED ,S PER INSTRUCTIONS 4"X4" P.T. SKID (CONT.) ALL STUDS SECURED TO SOLE PLATE AND FLOOR FRAMING W/ SIMPSON H8 TWIST STRAP w/ 4 -10d NAILS ON TOP INTO STUD, SECURING INTO RIM JOIST ON BOTTOM W/ 4-10d NAILS (TYPICAL) VARIES N L 2"X4" SYP #2 STUD_ S @ 24" O.C. SHED LENGTH (MAX. 40'-0") A SIDEWALL FRAMING A2 SCALE: 3/8" = 1'-0" NOTE: WALL FRAMING MEMBERS ARE CONTINUOUS FROM FOUNDATION SILL TO ROOF AND SECURED TO ENSURE A CONTINUOUS LOAD PATH. WHERE WALL MEMBERS ARE 1 NOT CONTINUOUS, SHEET METAL CLAMPS, TIES, OR CLIPS SHALL BE FORMED OF GALVANIZED STEEL OF NOT LESS THAN 0.040" NOMINAL THICKNESS. BUNGALOW SHED ENDWALL T.T ,L TOP LINE EN EERINO_ LLC —I`L STRUCTURAi EI:GI�IEEFS William E. Neary, III SMP-51, SMI-79, ICC 5185040 10649 Oakview Pointe Terrace Gotha, Florida 34734 2"X4" SYP#2 SOLE PLATE 1 2"X6" SYP#2 PERIMETER WALL SHEATHING OPTIONS: - %6" OSB OR SHEATHING EQUIV. OR BETTER - CORRUGATED ALUMINUM - D4 ALUMINUM SIDING -Y2" OR 5/" T1-11 SIDING - JAMES HARDIE PANEL OR EQUIV. - JAMES HARDIE HORIZ. SIDNG LAP OR EQUIV. - 29 GA CORRUGATED STEEL METAL SIDING (RUN ANY DIRECTION) - THERMO-PLY BLUE (0.135 THICK) W/ VINYL SIDING CONSULTING ENGINEER JULIO ORBEGOSO FLORIDA PE LICENSE #38769 ' \ �' (2) 2"X4" W/ 1/2" PLYWOOD / utj I c: V I- I y-LULI Z ~' `� V SUPERIOR SHEDS Julio g •y' /STOP SOLE�PLATE,% /yv,� / !i / � ' /�/; OR OSB FILLER OR (1) 4"x4" z. a: ' ` FO N'E 1rING"ti. .. ' /%fi 877 439-7433 Orbego o DRAWN: R.L.G. r 2323 S. VOLUSIA AVE. ORANGE CITY, FL 32763 oReF o v 2'JC4"SYP#2,STUDS,,� / `J�\oJ�SeGos 202 .O U-NONH >' X / �� = 2"X4" SYP#2 S IGN, CO. ` o'; �`'; �1@ 2' o C: - JOB: SS20-B / /;1, ,\ `r' k; ! , KING STUD MODULAR PLAN DES _ * " *769 * _ r' X x ,vim -> y C"I',,,Y\% ,, J , .Y, `\ , / �,�� ' `, 1J�pO�'.. 'SATE OP .' <u�� O SHEET NO. 7 F GRID, \�� (� //�� �/ �' iSS'ONAL ENG 09.0`r.O g OPTIONAL HYDROVENT DETAIL SIDEWALL DOOR & WINDOW (Ty P) �a�: , U MODULAR 2 DORIs ORNE., SUITE 105 OFFICE: M.688.1054 -O S O O SCALE: NTS SCALE: NTS LAKELAND.-.IDA FAX-.888.7118 PLANS DESIGN, CO. 33813 COLS®MODULARPLANSCO.COM 2021-01-20 TOP LINE ENGINEERING APPROVAL PLAN # BUNG-20 *** NOT HVHZ APPROVED SKID RUNNER SPACING* WIDTHS 6'-0" 8'-011 10'-01' 11'-8" 13'-8 A 0'-10"0'-9" 1'-7" 2'-8" 1'-10.5 B 51 6'-6" 6'-10" 6'-4" V-10.5" C *VALUES ARE FROM END OF JOIST TO CENTERS OF (2) 4"X4" SKIDS ONLY. 13'-8" WIDE SHEDS HAVE (4) SKIDS. A TLC TOP LINE ENGLNEERINGLLLC STRUCTURAL ENGINEERS Y William E. Neary, III SMP-51, SMI-79, ICC 5185040 . 10649 Oakview Pointe Terrace Gotha, Florida 34734 FLOOR SHEATHING Q 1111111MIM Q 2-1/2" X 1/2" THRU-BOLT SHED OVERALL LENGTH (MAX. 40'-0") 0 io )OR SHEATHING: " PLYWOOD " P.T. PLYWOOD - Y4" T&G - Y4" P.T. T&G t SIMPSON HL33 HEAVY ANGLE _ 2"x6" CONTINUOUS _ P.T. FLOOR JOIST _ CONSULTING ENGINEER z JULIO ORBEGOSO I I I I 1 112" FLORIDA o i i i i NOTCH BUNGALOW SHED PE LICENSE #38769 4"X4" P.T. SKID o MODULAR STRUCTURE FOR: DATE: 01-19-2021 5 4-1/2"X1/2" SUPERIOR SHEDS D".be ulio THRU-BOLT (877) 439-7433 Orbego oDRAWN: R.L.G. 2323 S. VOLUSIA AVE. ORANGE CITY, FL 32763 ',,FLOOR JOIST TOSKID CONNECTION:s° 2021.01. JOB: SS20-BU-NONH SCALE;NTS MODULAR PLANS DESIGN, CO.*- cli 0N-fB"G���.' SHEET NO. �. 09:04:2 EL MODULAR-05'00' Ci 202 DORIS DRNE, SUITE 10fi OFFICE: Bfi3.688.1054 LAX ELAND, FLORIDA FAX:863.688.7118 PLANS DESIGN, CO. 33813 DOLE®MODULARRLANSCO.COM A31 2021-01-20 TOP LINE ENGINEERING APPROVAL PLAN # BUNG -20 *** NOT HVIH7 APPR(')VFn (n- D F— :J 0 Z w } Z a a 0 U Z 0 y w 0 U) Z o_ 0 O N 0 x a 0 U NOTE: INSTALLATION FOR ALL ROOF SHEATHING OPTIONS AS PER MANUFACTURER INSTRUCTIONS SIDEWALL BELOW -\ D4 ALUMINUM ROOFING w w IL a- O O CIO -j Cn b0 ih 2"X4" TRUSSES @ 24" O.C. - " _ -00 of RIDGE L I NE >p 0 to zC w Co 1"X4" RUNNERS o i0 a 0- O O J Co J C SHED LENGTH (MAX. 40'-0") ROOF FRAMING PLAN SCALE: 318" = 1'-0" -TLETOP LINE ENGINEERING,_LLC Y STRUCTURALEUGINEERS William E. Neary, III SMP-51, SMI-79, ICC 5185040 10649 Oakview Pointe Terrace Gotha, Florida 34734 CONSULTING ENGINEER JULIO ORBEGOSO FLORIDA BUNGALOW SHED PE LICENSE #38769 MODULAR PLANS DESIGN, CO. E MODULAR 202 DRIVE, SUITE FLORIOA 105 OFFICE: 86 :6688.F0 9 PLANS DESIGN, CO. ` COLE®MODULARPLANSCO.COM 2021-01-20 TOP LINE ENGINEERING APPROVAL PLAN # BUNG-20 *** NOT HVH7 APPROVFn MIN. 3:12 MAX. 8:12 F_�_11 2"X4" SYP#2 COLLAR TIE 2"X5" MITEK MT20 OR EQUIVALENT 2"X4" SYP #2 STUDS @ 24" O.C. 2"X4" SYP#2 BLOCKING 4"X4" P.T. SKID (CONT.) FLOOR DECKING (CONT.) FLOOR JOISTS @ 16" O.C. SHED WIDTH (6'-0", 8'-0", 10'-0", 1 V-8", 13'-8") A CROSS SECTION 'A' A5 SCALE: 3/8" = V-0" NOTE: 2"X4" STUDS TO BE Fb = 1200 PSI OR GREATER NOTE: WALL FRAMING MEMBERS ARE CONTINUOUS FROM FOUNDATION SILL TO ROOF AND SECURED TO ENSURE A CONTINUOUS LOAD PATH. WHERE WALL MEMBERS ARE NOT CONTINUOUS, SHEET METAL CLAMPS, TIES, OR CLIPS SHALL BE FORMED OF GALVANIZED STEEL OF NOT LESS THAN 0.040" NOMINAL THICKNESS. 2"X4" ROOF TRUSSES @ 24" O.C. 2"X4" SOLE PLATE 2"X6" PERIMETER SISTER STUDS FOR 4'-0" FROM ENDWALL (TYP),_ TYPICAL STUD SPACING 24" O_C_ MAX SISTER STUDS FOR 4'-0" FROM ENDWALL (TYP) ........................................................................................................................................................................................................................................................................................................ MEMNON FLOOR •• @ 24" • ITRUSSES roil �: i>o�iJ✓ s IJIJJ�JI> roil �oiJ � SEE HEADE � CO IIE IL 1 DECKING Ic NT.) • SHED LENGTH (MAX. 40 ALL STUDS SECURED TO SOLE PLATE WALL SHEATHING OPTIONS: AND FLOOR FRAMING W/ 0.039" - %s' OSB OR SHEATHING EQUIV. OR BETTER (1 MM)x12" STRAP w/ 4 -10d NAILS - CORRUGATED ALUMINUM ON TOP INTO STUD, SECURING B CROSS SECTION 'B' - D4 ALUMINUM SIDING INTO RIM JOIST ON BOTTOM A5 W/4-10d NAILS (TYPICAL) SCALE: 3/8°=��-o" -Yz" OR5/8' T1-11 SIDING - JAMES HARDIE PANEL OR EQUIV. - JAMES HARDIE HORIZ. SIDNG LAP OR EQUIV. - 29 GA CORRUGATED STEEL METAL SIDING (RUN ANY DIRECTION) - THERMO-PLY BLUE (0.135 THICK) W/ VINYL SIDING �TLC LLC TOP LINE ENGINEERING,_' STRUCTUfL1L ENGINEERS V William E. Neary, III SMP-51, SMI-79, ICC 5185040 10649 Oakview Pointe Terrace Gotha, Florida 34734 BUNGALOW SHED MODULAR STRUCTURE FOR: SUPERIOR SHEDS (877) 439-7433 2323 S. VOLUSIA AVE. ORANGE CITY, FL 32763 MODULAR PLANS DESIGN, CO. E MODULAR Z2 DORIS DRIVE. SUITE AKEIANICE: 863."81054 D, FLORIDA 108 OFFFAX. 80.688.71 8 PLANS DESIGN, CO. 37819 COLE®MDDULARPLANSCO.COM — ENDWALL \ 2"X4" SOLE PLATE �- 2"X6" PERIMETER CONSULTING ENGINEER JULIO ORBEGOSO FLORIDA PE LICENSE #38769 I \ Julio\ �.�\O ORBFG Orbego 10ENSj'. Os�i - N0.96768 ° - 2021.01 STATE OF ;' (<,�� �SS�ONALE, 09:04:5: -0TO0; 2021-01-20 TOP LINE ENGINEERING APPROVAL PLAN # BUNG-20 *** NOT HVHZ APPROVED MIN. 3:12 MAX. 8:12 NX41' S�P@ 24'1 �DC. " SYPM BLOCKING E PALATE SHED WIDTH (6'-0", 8'-0", 10'-0", 11'-8", 13'-8") 4"X4" P.T. SKIDS ATTACHED W/ SIMPSON H24 OR EQUIVALENT. SEE TABLE 2 FOR SPACING. 2"X5" MITEK MT20 OR EQUIVALENT A ENDWALL FRAMING A6 SCALE: 3/8" = V-0" Z a a 0 U Z C7 a) w 0 w Z g a Of 0 0 0 0 N H x 0 a 0 U O SHED WIDTH (6-0", 8'-0", 10'-0", 11'-8", 13'-8") B ENDWALL FRAMING A6 SCALE: 3/8" = V-0" j LG LLC TO STRUCTURAL E,-41N ER� Y William E. Neary, III SMP-51, SIVII-79, [CC 5185040 10649 Oakview Pointe Terrace Gotha, Florida 34734 " ROOF TRUSSES MIN. 3:12 @ 24" O.C. MAX. 8:12 �i (4" SYP #2 STUDS @ 24" O.C. ' SYP#2 BLOCKING 2"X4" SYP#2 SOLE PLATE — K6" PERIMETER 2"X5" MITEK MT20 OR EQUIVALENT (2) 2"X4" HEADER MAX 36" SHED WIDTH (6-0", 8'-0", 10'-0", 11'-8", 13'-8") 4"X4" P.T. SKIDS ATTACHED W/ SIMPSON H24 OR EQUIVALENT. SEE TABLE 2 FOR SPACING. B ENDWALL FRAMING A6 SCALE: 3/8" = V-0" CONSULTING ENGINEER JULIO ORBEGOSO FLORIDA BUNGALOW SHED PE LICENSE #38769 MODULAR PLANS DESIGN, CO. I MODULAR .EAND FL0R1ppU1TE 186 OF ICE:863.688.10 54 8 FA PLANS DESIGN, CO. 33813 COLE®MODUTARPLANSCO.COM 2021-01-20 TOP LINE ENGINEERING APPROVAL PLAN # BUNG-20 *** NOT HVHZ APPROVED } z Q 0_ 0 0 Z 0 N W 0 U) Z a Q� J 7 C] O 0 0 N F x D: a O L) O SIMPSON STRONG DRIVE & STRAP - SD SCREW SCHDEULE PART#/DESC. UPLIFT WALL FASTENER RAFTER FASTENER PLATE FASTENER H7 435 6-S09x1.5" 4-SD9xl.5' H11Z 750 6-SD1 OX2.5' 6-SD10x2.5' H2A 495 5-SD9xl.5' S-SD9xl.5' 2-S09xl.5' H2.5A 540 5-S09x1.5" 5-S09x1.5' H2Z 410 5-SD9x1.5" 5-SD9x1.5' RAFTER H2.5T 545 5-SD9x1.5' 5-SD9xl.5' H2A 495 7-S09x1.5' 5-SD9xl.5' H3 320 4-SD9x1.5' 4-SD9xl.5' H4 280 4-SD9xl.5' 4-SD9xl.5' H5 415 4-SD9xl.5' 4-SD9xl.5' LTS-12 895 6-SD9xl.5' 6-SD9xl.5' LTS-16 1075 6-SD9xl.5' 6-SD9xl.5' LTS-18 1235 6-SD9x1.5" 6-SD9x1.5' LTS-20 1215 6-SD9xl.5' 6-SD9x1.5' MTS-12 895 7-SD9xl.5' 7-SD9xl.5' MTS-16 1075 7-SD9xl.5' 7-SD9xl.5' MTS-18 1255 7-SD9x1.5' 7-SD9x1.50 MTS-20 1255 7-SD9xl.5' 7-SD9xl.5' PORCH PART#/DESC. UPLIFT COLUMN FASTENER RAFTER FASTENER A21 2-SD9x1.50 2-SD9x1.5' A23 4-SD9xl.5' 4-SD9xl.5" A33 4-SD9xl.5" 4-SD9xl.5" BTM PLATE PART#/DESC. UPLIFT WALL FASTENER I FLOOR FASTNER LSTA-18 1235 7-SD9x1.5' 7-SD9x1.5' TIE -DOWNS PART#/DESC. UPLIFT WALL FASTENER FLOOR FASTENER 20GA. 1-114"WIDE 4725 7-SD9xl.5' 5/8'x3O" ANCHOR 4300 A. ONLY NEEDED ON ALUMINUM SHEATHING WALLS. B. HEADERS OVER 6' SPAN. STRAP & FASTENER SCHEDULE' PART#!DESC. .UPLIFT _ WALL FASTENER _ RAFTER FASTENER PLATE FASTENER H1 400 6-8dx1/5- 4-8d RAFTER (B) H11Z 750 6-16dx2.5' 6-16dx2.5" H2A 495 5-8dx1.5" 5-Sdxl.5' 28dxl.5' H2.5A 535 - 5-8d 5-8d H215 410 5-8d 5-8d H2.5T 545 5-8d 5.8d H2A 495 7-8dx1.5' 5-Bdxl.5' H3 320 4.8d 4-8d - H4 235 4.8d 4-8d H5 265 4.8d 4.8d LTS-12 620 6-10dx1,5' 6.10dxl.5' LTS-16 620 6-10tlX1.5" 6-10dxl.5' LTS-18 620 6.10dx1.5' 6-10&1.5" LTS-20 620 6.10dxl.5' 6-10dxl.5' MTS-12 860 7-10dxl.5" 7-10dxl.5' MTS-16 860 7-10dxl.5" 7-10dxl.5" MTS-18 960 7-10dxl.5" 7-10dxl.5" MTS-20 860 7-10dx1,5' 7-10dxl.5" PORCH PART#IDESC. UPLIFT COLUMN FASTENER RAFTER FASTENER A21 245 2-10dx1.5' 2-10dxl.5' A23 685 4-10dx1.5' 4-10dxl.5" A33 750 4 - 10d 4 -16d BTM PLATE PART#IDESC. UPLIFT WALLFASTENER FLOOR FASTENER LSTA-18 1110 7 -10d 7 - 10d HEADER (D) PART#IDESC. UPLIFT STUD FASTENER HEADER FASTENER TP-35 NIR 5'-3'x0.131' S'-3'x0.131" HP40.41,80.81 4725 5'-3"XO.131' 5'-3'4.131' TIE -DOWNS PART#IDESC. UPLIFT WALL FASTENER FLOOR FASTENER 20GA. 1-1/4"WIDE 4725 7-10dxl.5- 5/8"x30" ANCHOR 4300 ' ALL STRAPS CAN BE SUBSTITUTED WITH AN EQUIVALENT BRAND MEETING SAME STRENGTHS. B. RAFTER TIES TO STUD WALL TO BE AT EVERY CONNECTION FOR 24' O.C. & CAN EVERY OTHER FOR 16" O.C. BUT IS REQUIRED ON CORNERS AND STUDS ADJACENT TO CORNERS. C. ONLY NEEDED ON ALUMINUM & VINYL SHEATHING WALLS. D. HEADERS OVER 6'-0" SPAN. PRODUCT OPTIONS PRODUCT CAT. SUB. CATEGORY MANUFACTURER MODEL I DESC. STATE OF FL APPROVAL P. PANEL WALLS SIDING JAMES HARDIE 5116' CEDAR FL#: 13223.1 PANELWALLS SIDING JAMES HARDIE 5116"STUCCO FL#: 13223.2 PANEL WALLS SIDING ADVANCED ALUM. 0.19 GA FL#: 23138.1 PANEL WALLS SIDING PLY GEM X FL#: - PANEL WALLS SIDING ADVANCED ALUM. X FL#: 31737.1 PANEL WALLS SIDING SIMPSON LUMBER X FL#: - EXTERIOR DOORS SWINGING EXT EAGAN E1HDL FL#: 12820-R3 EXTERIOR DOORS SWINGING EXT CROFT 2DO 9-LITE FL#: - WINDOWS SINGLE HUNG CROFT VRTSLIDER FL#: 10853-RS WINDOWS SINGLE HUNG CROFT VERT SLIDER FL#: 15527-R5 WINDOWS SINGLE HUNG CROFT VERT SLIDER FLtt. 16082-R3 WINDOWS SINGLE HUNG CROFT VERT SLIDER FL#: 16153-Rl WINDOWS HORIZ SLIDER CROFT HORIZ. SLIDER FL#: 27202 WINDOWS HORIZ. SLIDER CROFT HORIZ. SLIDER FL#:28822 WINDOWS HORIZ. SLIDER CROFT HORIZ. SLIDER FL#: 30848 FASTENING SCHEDULE (FBC TABLE 2304.10.1) CONNECTION FASTENING CONNECTION 24. BUILT-UP GIRDER AND BEAMS 20d COMMON (4- X 0.192-) AT 32" O.C. 3' X 0.131 NAILS AT 24' O.C. FACE NAIL AT TOP AND BOTTOM STAGGERED ON OPPOSITE 1. JOIST TO SILL OR GIRDER 3 -8d COMMON (2 112-X 0.131') TOENAIL 3 - 3' 14 GAUGE STAPLES 3' 14 GAUGE STAPLES AT 24" O.C. 2 - 20d COMMON (4" X 0.192-) SIDES 2. BRINGING TO JOIST 2 - 8d COMMON (2 1/2" X 0.131-) TOENAIL EACH END 2 - 8d COMMON (2 1/2- X 0.131-) 3 - 3" X 0.131" NAILS FACE NAIL AT ENDS AND AT 2 - 3' 14 GAUGE STAPLES 3 - 3" 14 GAUGE STAPLES EACH SPLICE 3. 1'x6' SUBFLOOR OR LESS TO EACH JOIST 2-8d COMMON (2 112-X 0.131-) FACE NAIL 25. 2' PLANKS 16d COMMON (3 1/2- X 0.162") AT EACH BEARING 4. WIDER THAN 1'x6' SUBFLOOR TO EACH JOIST 3 - Ed COMMON (2 112" X 0.131") FACE NAIL 26. COLLAR TIE TO RAFTER 3 - 10d COMMON (3- X 0.148-) MIN. 4 - 3" X 0.131" NAILS 4- 3' 14 GAUGE STAPLES FACE NAIL 5. 2" SUBFLOOR TO JOIST OR GIRDER 2 -16d COMMON (3 1/2' X 0.162-) BLIND AND FACE NAIL 6. SOLE PLATE TO JOIST OR BLOCKING 16d (3 1/2" X 0.135-) AT 16- O.C. TYPICAL FACE NAIL W X 0.131 NAILS AT 8' O.C. 27. JACK RAFTER TO HIP 3 -10d COMMON (3" X 0.148') TOE NAIL 3' 14 GAUGE STAPLES AT 12' O.C. 4-3'X0.131 NAILS SOLE PLATE TO JOIST AT BLOCKING AT 3 - 16d COMMON (3 1/2- X OA35-) AT 16' O.C. 4 - 3" 14 GAUGE STAPLES BRACED WALL PANEL 4 - 3' X 0.131" NAILS AT 16" O.C. BRACED WALL PANEL 2 -16d COMMON (3 112-X 0.162-) 4 - 3' 14 GAUGE STAPLES AT 16' O.C. 3 - 3' X 0.131' NAILS 3 - 3' 14 GAUGE STAPLES FACE NAIL 7. TOP PLATE TO STUD 2 - 16d COMMON (3 1/2' X 0.162') END NAIL 28. ROOF RAFTER TO 2-BY RIDGE BEAM 2 -16d COMMON (3 1/2 X 0.162-) TOE NAIL 3 - 3' X 0.131" NAILS 3 - 3' 14 GAUGE STAPLES 3 - 3' X 0.131 NAILS 3 - 3' 14 GAUGE STAPLES 8. STUD TO SOLE PLATE 4 - 8d COMMON (21/2' X 0.131') TOE NAIL 4 - 3' X 0.131 NAILS 3 - 3' 14 GAUGE STAPLES 2 - 16d COMMON (3 112- X 0.162') 3 - W X 0.131' NAILS FACE NAIL 2 -16d COMMON (3 1/2" X 0.162'� 3 - 3' 14 GAUGE STAPLES 3 - 3' X 0.131" NAILS 3 - 3" 14 GAUGE STAPLES END NAIL 29. JOIST TO BAND JOIST 3 -16d COMMON (3 1/2' X 0.135') FACE NAIL 4 - 3' X 0.131' NAILS 4 -3' 14 GAUGE STAPLES 9. DOUBLE STUDS 16d (3 112" X 0.135') AT 24- O.C. FACE NAIL 3' X 0.131 NAILS AT 8" O.C. 30. LEDGER STRIP 3 -16d COMMON (3 112' X 0.162-) FACE NAIL AT EACH JOINT - 3' 14 GAUGE STAPLES AT 8' O.C. 4 - 3' X 0.131' NAILS 4 -3" 14 GAUGE STAPLES 10. DOUBLE TOP PLATES 16d (3 112- X 0.135') AT 16- O.C. TYPICAL FACE NAIL 3' X 0.131 NAILS AT 8' O.C. 3' 14 GAUGE STAPLES AT 8' O.C. 31. WOOD STRUCTURAL PANELS AND 1/2' AND LESS 6d (OI,Q) PARTICLEBOARD (B) SUBFLOOR, ROOF AND 2 310'X0.113' NAIL (N) DOUBLE TOP PLATES 8-16d COMMON (3 1/2' X 0.135-) AT 16' O.C. LAP SPLICE WALL SHEATHING (TO FRAMING) 1 314.16 GAUGE(0) 12-3' XO.131'NAILSATI6' O.C. 19132'TO 314' 8d(D)OR 6d(E) 12 - 3' 14 GAUGE STAPLES AT 16" O.C. SINGLE FLOOR (COMBINATION SUBFLOOR- 29/8'XO.113- NAIL( 2' 16 GAUGE (P) 6' O.C. EDGES AND INTERMEDIATE, 4' O.C. AT COMPONENT AND 11. BLOCKING BETWEEN JOISTS OR RAFTERS 3 - 8d COMMON (2 1/2' X 0.131') TOENAIL TOTOPPLATE 3 - 3' X 0.131" NAILS UNDERLAYMENT TO 19/32' TO 314"FRAMING 7/8" TO 1' 8d(C CLADDING EDGE STRIP #ZONE 3 3 - 3' 14 GAUGE STAPLES 1 1/8' TO 1 1/4" 10d(�) OR 8d(D) - 314" AND LESS 6d((C)) (REFER TO FIG. 30.5-1 OF ASCE 7) 12. RIM JOIST TO TOP PLATE 8d COMMON (2 1/2' X 0.131-) AT 6- O.C. TOENAIL 3' X 0.131" NAILS AT 6' O.C. 718' TO 1" 8d(C) 3' 14 GAUGE STAPLES AT 6" O.C. 1 118- TO 1 1/4" 10d(D) OR 8d(D) 13. TOP PLATES, LAPS AND INTERSECTIONS 2 -16d COMMON (3 1/2-X 0.162") FACE NAIL 32. PANEL SIDING (TO FRAMING) (Q) 1l2' OR LESS 6d(F) 3-3'140GAUGE STAPLES 5/8' 8d(F) 14. CONTINUOUS HEADER, TWO PIECES 16d COMMON 3 1/2' X 0.162" 16' O.C. ALONG EDGE 33• FIBERBOARD SHEATHING (G.Q) 1/2' AND LESS NO. 11 GAUGE ROOFING NAIL(H) 6d COMMON NAIL (2'x0.113') NO. 16 GAUGE 15. CEILING JOISTS TO PLATE 3 - 16d COMMON (3 112- X 0.131-) TOE NAIL 5 - 3' X 0.131' NAILS 25132" STAPLE (1) NO. 11 GAUGE 6-O.C. EDGES AND INTERMEDIATE 3-3 ' 14 GAUGE STAPLES NAIL(H) 8d COMMON NAIL (2 1/2-4.131") NO. 16 GAUGE STAPLE (1) 16. RIM JOIST TO TOP PLATE 4 - 8d COMMON (2 1/2' X 0.131") TOE NAIL 17. CEILING JOISTS, LAPS OVER PARTITIONS 3 -16d COMMON (3 112-X 0.135-) MIN. FACE NAIL 34. INTERIOR PANELING (SEE TABLE 2308.10A.1) 4 - 3' X 0.131' NAILS 8. 6d(K� 670.C. EDGES AND INTERMEDIATE 4 - 3' 14 GAUGE STAPLES 18. CEILING JOISTS TO PARALLEL RAFTERS 3 - 16d COMMON (3 112- X 0.135') MIN. FACE NAIL A. COMMON OR BOX NAILS ARE PERMITTED TO BE USED EXCEPT WHERE OTHERWISE STATED. B. NAILS SPACED AT 6 INCHES ON CENTER ON CENTER AT EDGES, 12 INCHES AT INTERMEDIATE SUPPORTS EXCEPT 6 INCHES AT (SEE TABLE 2308.10A.1) 4 - 3" X 0.131" NAILS SUPPORTS WHERE SPANS ARE 48 INCHES OR MORE. FOR NAILING OF WOOD STRUCTURAL PANEL AND PARTICLEBOARD DIAGRAMS 4 - 3' 14 GAUGE STAPLES AND SHEAR WALLS, REFER TO SECTION 2305. NAILS FOR WALL SHETHING ARE PERMITTED TO BE COMMON, BOX OR CASING. D. COMMON ((6d - 2' xC. COMMON OR 00. 13� 8d-2 112" x 0 131': 1 Od- 313`' x 0.148112' x 0.131'; 10d - 3' x 0.148'). E.DEFORMEb SHANKON-RESIST(6d-2'xO.113;8d-2112"xO.131'; 10tl-�'x0.1483-3 19. RAFTER TO PLATE 3- 8tl COMMON(21/2' X 0.131-) TOENAIL 3 -3' 140GAUGE STAPLES . OR NG ( 1 L. G. FASTENERS SPACED 3 NCH S OSIDING N CENTER ATI 718"x 1EXTERIOR EDGESIAQ 6 INCHES 0 CENTER AT INTERMEDIATE SUPPORTS. WHEN USED AS STRUCTURAL SHEATHING. SPACING SHALL BE 61NCHES ON CENTER ON THE EDGES AND 12 INCHES ON CENTER AT INTERMEDIATE SUPPORTS, WHEN USED FOR NONSTRUCTURAL SHEATHING. 20. 1' DIAGONAL BRACE TO EACH STUD 8 PLATE 2 -8d COMMON (2 1/2-X 0.131-) FACE NAIL 2-3' X 0.131' NAILS H. CORROSION -RESISTANT ROOFING NAILS WITH 7/16' DIAMETER HEAD AND 1 112" LENGTH FOR 1/2' SHEATHING AND 1 3/4' LENGTH FOR 3 - 3' 14 GAUGE STAPLES SHEATHI. CORROSION -RESISTANT STAPLES WITH NOMINAL 7/16' CROWN OR 1' CROWN AND 1 1/4' LENGTH FOR 112" FOR 25/32 SHETHING PANEL SUPPORTS AT 16- (20' IF STRENGTH AXIS IS THE LONG DIRECTION OF THE PANEL, UNLESS OTHERWISE MARKED). K. PANEL SUPPORTS AT 24". CASING OR FINISH NAILS SPACED AT 6 INCHES ON PANEL EDGES, 12 INCHES AT INTERMEDIATE SUPPORTS. L. FOR ROOF SHEATHING APPLICATIONS, 8d NAILS (211T x 0.113") ARE THE MINIMUM REQUIRED FOR WOOD STRUCTURAL PANELS. M. STA LES SHALLWIDTH OF 7/16'. N. OR ROOF SHEATH NG APPLICATIONS, CROWNVE A MINIMUM TENERS SPACED AT 4 INCHES ON CENTER AT EDGES, 8 INCHES AT INTERMEDIATE 21. l"X8' SHEATHING TO EACH BEARING 3 - 8tl COMMON 2 1/2" X 0.131' FACE NAIL 22. WIDER THAN 1'XB" SHEATHING TO EA -BEARING 3 - 8d COMMON (2 112" X 0.131-) FACE NAIL 23. BUILT-UP CORNER SUDS 16d COMMON (3 112" X 0.162") MIN. 24" O.C. 3' X 0.131' NAILS 16' O.C. SUPPORTS. 3" 14 GAUGE STAPLES 16' O.C. O. FASTENERS SPACED AT 4 INCHES ON CENTER AT EDGES, 8 INCHES AT INTERMEDIATE SUPPORTS FOR SUBFLOOR AND SHEATHING 3 INCHES ON CENTER AT EDGES, 6 INCHES AT INTERMEDIATE SUPPORTS FOR ROOF SHEATHING. P. FASTENERS SPACED AT 41NCHES ON CENTER AT EDGES, 8 INCHES AT INTERMEDIATE SUPPORTS. Q. SEE FASTENER ALTERNATE SCHEDULE. R. FASTENERS MUST BE INSTALLED WITH EVEN SPACING BETWEEN THEM ACROSS ATTACHING MEMBER. ALTERNATE FASTENING SCHEDULE CONNECTION FASTENING ALT 31-33. WOOD STRUCTURAL PANELS AND PARTICLEBOARD SUBFLOOR, ROOF AND WALL SHEATHING (TO FRAMING) I 1/2- AND LESS I 2' X 0.092' RING SHANK NAIL 5' FROM EDGE, 10' O.C. A TL-M TO LINE STRUCTURAL E1EGRINGRS_LLC Y William E. Neary, III SMP-51, SMI-79, ICC 5185040 10649 Oakview Pointe Terrace Gotha, Florida 34734 MODULAR PLANS DESIGN, CO. CONSULTING ENGINEER JULIO ORBEGOSO FLORIDA BUNGALOW SHED PE LICENSE #38769 MODULAR PLANS DESIGN, CO. 202 DORIS DRIVE.. SURE 105 OFFICE 863.688.1054 LAKELAND. FLORIDA FAX 863.688.7118 33813 COLE@MODULARPLANSCO.COM 2021-01-20 TOP LINE ENGINEERING APPROVAL PLAN # BUNG-20 *** NOT HVHZ APPROVED