12
PLUMB CUT CANTILEVER 51--
6.1116"
1EEL HEIGHT
r-a,
HANGER LEGEND
• - ALL 2x HANGERS SHOWN ARE HTU26 UNLESS NOTED
OTHERWISE
• - ALL 4x2 FLOOR HANGERS SHOWN ARE HHUS46
UNLESS NOTED OTHERWISE
_ MAIN WIND FORCE RESISTING SYSTEMIC-C HYBRID
WIND ASCE7-10
ENCLOSED
EXPOSURE CATEGORY C
OCCUPANCY CATEGORY 11 '
WIND LOAD 170 MPH
'TRUSSES HAVE BEEN DESIGNED FOR A 10.0 PSF
BOTTOM CHORD LIVE LOAD NONCONCURRENT WITH
ANY OTHER LIVE LOADS
ROOF LOADING FLOOR LOADING
TCLL: 20 PSF TCLL: PSF
TCDL: 15 PSF TCDL: PSF
BCDL: 10 PSF BCDL: PSF
TOTAL: 45 PSF TOTAL: PSF
DURATION: 1.25 DURATION:
CAUTIONM
DO NOT ATTEMPT TO ERECT
TRUSSES WITHOUT REFERRING TO
THE ENGINEERING DRAWINGS AND
BSC1431 SUMMARY SHEETS.
ALL PERMANENT BRACING MUST BE
IN PLACE PRIOR TO LOADING
TRUSSES. (10. -SHEATHING,
SHINGLES, ETC.)
ALL INTERIOR BEARING WALLS
MUST BE IN PLACE PRIOR TO
INSTALLING TRUSSES.
REFER TO FINAL ENGINEERING
SHEETS FOR THE FOLLOWING.
1) NUMBER OF GIRDER PLIES AND
NAILING SCHEDULE.
2) BEARING BLOCK REQUIREMENTS.
3) SCAB DETAILS (IF REQUIRED)
4) UPLIFT AND GRAVITY REACTIONS.
WARNING
Backcharges Will Not Be Accepted
Regardless of Fault Without Prior
Notification By Customer Within 48
Hours And Investigation By
Builders Flrst8ource.
NO EXCEPTIONS.
The General Contractor Is Responsible
For All Connections Other Than Truss
to Truss, Gable Shear Wall, And
Connections. Temporary and
Permanent Bracing, And Ceiling And
Roof Diaphragm Connections.
TRUSS CONNECTION
LIST
Q
PRODUCT
6
LUS26
HTU26
HTU28
1
HHUS26-2
HGUS26-2
HGUS28-2
HGUS28-3
BUILDER:
TNT BLDRS
RES:
N/A
MODEL:
NIA
ADDRESS:
ARAPAHOE
LOT IBLOCK:
CITY:
FORT PIECE
COUNTY
ST LUCIE CO
DRAWN BY:
JL
JOB 11 :
2103091
DATE: 10103N9 SCALE: NTS
REVISIONS:
1. CHANGE BEAM HEIGHTS 10110/19
2.
3.
4.
IMPORTANT
This Drawing Must Be Approved And
Returned Before Fabrication Will
Begin. For Your Protection Check All
Dimensions And Conditions Prior To
Approval Of Plan.
Ln MA;MOM
SIGNATURE BELOW INDICATES ALLrC}Snl
ryr�e
NOTES AND DIMENSIONS HAVE
r st ou V
ABEEN ACCEPTED.
701 S. KINGS HIGHWAY
Ii - {I J . FORT PIECE, FL 34945
By Dale �1 Ph. (772) - 4615475
IV FILE COP'
Lumber design wall es are in accordance with ANSI/TPI 1. section 6.3
These truss, designs .rely on lumber..values established by others.
i
i
MiTek RF
O
RE 20103091-TNT = . ,�OV nc.
_.
Per... 4 ?419 ::
I Mi Tek USA, I
qr Site Information: �/tTampa,
East Blvd. 6 04 P
St 9 o mpa, F1_ K610-4115
Customer info:.TNT BLDRS Project Name: Model:
Lot/Block: Subdivision: a Coun(y ent
Address: ARAPAHOE STREET,.
City: FORT PIECE: State: FL
Name Address and License,#:of Structural Engineer of Record, If there is one,.for the building.
License #:
..
Name:; .
Address: .........
City: State:
General Truss Engineering Criteria' & Design. Loads (Individual_ Truss Design Drawings Show Special
Loading -Conditions):_-,
i:.
:Design Code: FBC2017/TP120144 Design Program: MiTek 20/20 8.2
Wind Code:. ASCE:7-10 Wind Speed: 170 mph
Roof Load: 45.0 psfq. Floor Load:. N/A psf
This package includes 48 individual, -Truss Design Drawings 'and 0 Additional Drawings.
With. my seal affixed to. this. sheet, I'hereby certify. that I' am the. Truss.Design Engineer and this index, sheet .
conforms to 61 G15-31.003',.section 5 of the Florida Board of Professional Engineers Rules.
" No: Seal# russ ame :Date: No. Seal# :Truss' Name:.:Date-
•.
1 T18336968 - Al 10/10/19 23 T1 8835985: C8 1:0%10/119
2: T18335964 A2 ... 10/10/19 24 : T18335986 C9. ; . 10/10/19 ; ;
3 :. T18335965 A3 10/10/19 25. . T18335987 CJ1 .. 10/10/19..
4. 718335966 A4 10/10/19 26: 718335988 CJ3 10/10/19
5 T1833596.7 A5. 10/10/19: 27 T18335989: CJ5 •10/10/19
.6 T18335968 : A6 10/10/19 28 T18335990. CJ31 10/10/19
7 T18335969• A7 10/10/19 29 T18335991 CJ51 10/10/19
8 T18335970 A8 : ; 10/10/19 30 :: T18335992 D1=:: 10/10/19
9 :..T18335971 A9 10/10/19 ,31 T18335993 D2- 10/10/19 :.-.:
10. ..71.8335972 A10 . 10/10/19 ; 32 :. - T18335994 D3 - .: - . ..: 10/10/1,9
-•11 T18335973 : B1 •10/10/.19 33 T18335995: EJ1 :10/10/19
12 T1833597.4 B2 10/10/19,34 T18335996 EJ5 1.0/10/1:9
: 1$.T18335975 B3 .. - .... .10/10/19 35 ... T18335997 EJ7. • - . - .. 10/10/19 , ..
... ,- .. . .
14: T18335976 B4 _ :. 10/10/19. 36, T1.8335998 EJ21: - 10/10/19 :.
15- • • •T18335977 B5 10/10/19. 37.... T18335999 EJ22.10/10/19' - -
..16 . T18335978 . C1. _10/10/19, 38 T18336000 . EJ71 10/10/19
17 T18335979 C2 10/10/19 39 T1 8336001: 'EJ72 10/10/19
18 T18335980, C3 10/10/19. 40 T1 8336002. G1 -10/10/19
19 : 718335981 C4 :: 10/10/19 41 ; : T18336003 'HJ5. 10/10/19 ::.:: • : .
20: . T18335982 C5 • . 10/10/19 42 ' T18336004 HJ7 : ::. 10/10/19
21, . T18335983 C6 10/10/19 43 : ; • T18336005 HJ71 10/10/19
- 22 T18335984 CZ :10/10/19: 44 T18336006 .V1 :. 10/10/19
The truss drawing(s)referenced above have been re ared b ER ,P.,�
Y P s P p.. •��GENS•%�,,,
MiTek�U8A, Inc. under m direct.su envision based on the. ammeters
provided by Builders FirstSourcc -Plant City. ;:• • No 22839. '�
Truss Design Engineer's Name: Finn; Walter::
J.
My -license renewal date for -the state of Florida is.February 28, 2021: .. '
IMPORTANT NOTE: The seal on these trus$ component designs is a dertification � ; STATE OF
00
that -the engineer named is; licensed.in:the jurisdiction(s)•identified and that the f .T • +�? P
designs comply with ANSI/TPI 1: These designs are based Upon'parameters �� FS O R'1
shown (e.g:, loads, supports; dimensions, shapes and design codes), which were
given to MiTekor:TRENCO. Any project: specific information included is for.MiTek's or
.. TRENCO's customers.file reference purpose only, and was not taken into account in the
preparation of these designs. MiTek or TRENCO has not independently verified.the _ WalterR'FnnpENo;22839
applicability. of the design parameters .or the designs for. any particular building. Before use,: MiTek 11Sll,;lnc fL GO 663A
tfie.building.designer should.verify applicability of design parameters and properly:... 6904_ParlieEast
BlvdiTBmpafl93610
incorporate these. designs into the overall building design per ANSI/TPI. i , Chapter 2: Date:;
October 10,2019.::
Finn, W alter
...... F . - : � 1 ��
FILE . ....
RE: 20103091-TNT -
Site Information:
Customer Info: TNT BLDRS Project Name: . Model: .
Lot/Block: . I Subdivision: .
Address: ARAPAHOE STREET,.
City: FORT PIECE State: FL
No. Seal# Truss Name Date
45
T18336007
V2
10/10/19
46
T18336008
V3
10/10/1'9
47
T18336009
V4
10/10/19
48
T18336010
V5
10/10/19
2 of 2
Job
Truss
Truss Type r 1
y
Y
T18335963
20.103091-TNT
Al -
ROOF SPECIAL
1
1
Job Reference (optional)
umaurs ruscauurua, run rracn, r...... +� , o.. „ ..,., �..... ......... .....- ..._. ..._ . _
ID:P ;;q GoIf3aThkEwERV6zC114-7xIpIGi09inTBnVovkmR'bpnwwHt12c3LbffIZSy sUh
-0, 6-5-4 it-2-8 15-11-12 20-9-0 23-2-0 29-10-0 34-0-0 i-39-8-0 4p-9.1i0 44-5-0 4$�0
1-8-0 4-9-4 4-9-0 2-5-0 6-8-0 4-2-0 5-8-0 -1-1 3-7-6 O.8.0
5x6 = Scale = 1:84.1
4x10MT20HS i4x6
5
4X6 4
3:
5.00 12 5x6 8
7
3x4
28
6
21
20
22 10x16 MT20HS =
4x6
4x6
29 9
5x6
10
5x6 Special
5x6 = 2x4 II
"'A11.12 13
23 6x8 � 1
. 2WX2
24 7x10 � 14
1 2 6x12 MT20HS %. 4.0012 o5 6x8- 18 17 V16 15
0 % _
3x6 — 26 2x4 II - BX14 MT20HS = ST1.5x8 STP = 5x6 =
ST1.5x8 STP = 6x8 = . Special
12x14 i
1-8-0
-0- 6-5-4 11-2-8 15-11-12 20-9-0 23-2-0 29-10-0 34-0-0 39-8-0 4 0 44-5-0
4-9-4 4-9-4 4-9-4 4-9-4 2-5-0 6-8-0 4-2-0 - 5-8-0 0 4 0 4-5-0
0-8-0
Plate. Offsets (X,Y)-- [3:0-2-4,0-1-8], [4:0-5-0,Edge], [7:0-1-8,0-1-12], [10:0-3-0,0-3-0], [16:0-3-8,0-4-4], [17:0-4-0,0-4-0], [19:0-5-8,0-5-4], [20:0-1-2,0-2-4], [25:0-5-0,0-2-8],
126.0-4-12 Edge]
LOADING (pso SPACING- 2-0-0 CSL DEFL. in (loc) Weil L/d PLATES GRIP
TCLL 20.0 Plate Grip DOL _ 1.25 TC ' 0.55Vert(LL) --0.65 21-22 >700 360 MT20 244/190
TCDL 15.0 Lumber DOL 1.25 BC 0.50 Vert(CT) -1.47 21-22 >310 .240 MT20HS 187/143
BCLL 0.0 Rep Stress Incr YES WB 0.92 Horz(CT) 0.96 16 n/a n/a
BCDL 10.0 Code FBC2017/TP12014 Matrix-SH Wind(LL) 0.85 21-22 >538 240 Weight: 282lb FT=20%
LUMBER-, BRACING-.
TOP CHORD 2x4 SP M 31 `Except" TOP CHORD - Structural wood sheathing directly applied or 2-4-3 oc.purlins, except
12-14,10-12: 2x4 SP No.2 end verticals.
BOT CHORD 2x6 SP M 26 'Except' BOT CHORD Fligid ceiling directly applied or 4-10-6 oc bracing.
1-26: 2x4 SP No.2, 0-18: 2x4 SP No.3, 15-18: 2x6 SP No.2 WEBS 1 Row at micipt 2-25, 7-20, 11-17
WEBS 2x4 SP No.3 'Except*,
2-26i 2x6 SP No.2, 2-25,7-21: 2x4 SP No. 1, 8-20: 2x4 SP No.2
REACTIONS. (lb/size) 26=1831/0-8-0, 16=2206/0-8-0 "'
Max Harz. 26=291(LC 12)
Max Uplift.26=-667(LC 42), 16=-862(LC 9)
Max Grav 26=1831(LC 27),.16=2206(LC 1)
FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-446/206, 2-27=-5844/3219, 3-27=-5721/3220, 3-4=-7903/4314, 4-5=-7857/4322,
5-6=-79133/4371, 6-28= 6961/3733, 7-28=-6886/3744, 7-8=-3989/2247, 8-29=-3989/2220,
9-29=-4087/2200, 9-10=-3725/2041, 90-11=-2072/1032, 11-12=-942/623
BOT CHORD 1-26=-218/455, 25-26=-289/11.8, 24-25=-3170/5627, 23-24=-4186/7645, 22-23=-418117663,
21-22=-4103/7721, 20-21=.-3313/6651, 19-20=-1786/3608, 9-19=-574/448,
16-17=-509/839, 15-16=-540/864
WEBS 2-26=-1563/1116; 2-25=-2936/5391, 3-25=-928/626, 3-24=-974/1946, 5-24=-369/271,
6-21=-1053/736; 7-21=-2308/4508,,8-20=-1427/2693, 9-20= 85/424, 17-19==920/2061,
10-19=-880/1665, 10-17=-1633/968, 7-2o= 4444/2488, 11-16=-2032/1448,
11=17=-1619/2417, 12-15=-942/580
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph:(3-second gust) Vasd=132mph; TCDL=4.2psf;'BCDL=5.Opsf; h=15ft; Cat. 11; Exp C; EncL,
GCpi=0.18; MWFRS (envelope) and C-C.Extedor(2) 0-0-0 to 6-0-0, Interior(1) 6-0-0 to 23-2-0, Extedor(2) 23-2-0 to 29-2-0, Interior(1)
29-2-0 to 45-1-0 zone; cantilever left ahcl right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.,
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a.live load of 20.Opsf on the bottom chord in all areas where.a.rectangle 3-6-0 tall by 2-0-0 wide
Walter P. Finn, PE No.22939
will fit between the bottom chord and any other members.
7) Provide mechanical, connection (by others) of truss to bearing plate capable of withstanding 667 lb uplift at joint 26 and 862 lb uplift at
MiTek USA, Inc, FL Cart6634
joint 16.
6904 Padre East Blvd. Tampa FL 33610
8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 12 lb down and 37 lb up at
Date:
45-1-0 on top chord, and 44 lb down and 10 lb up at 44-3-4 on bottom chord. The design/selection of such connection device(s) is
October 10,2019
the responsibility.of others.
A WARNING -Verify design parameters and READ NOTES ONTHIS AND INCLUDED MIrEK REFERANCE PAGE MII.7473 rev. 1010312015 BEFORE USE.
.
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not
���
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to. prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing .
T
M I W
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the .
fabrication, storage; delivery, erection and bracing of trusses and truss systems, seeANSVWII Quality Criteria, DSB-89'and SCSI Building Component
E
6904 Parke Eaast East Blvd... .
Saf©ty Infoanatlanovailable from Truss Plate Instltute; 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL
I
Builders FirstSource, Fort Piece, FL 34945 Run: 8.240 s Feb 11 2019 Print: 8.240 s Jul 27 2019 MITek Industries, Inc. Thu Oct 10 10:12:34 2019 .Page 2
I D:PftLgXzGof3aThkEwERV6zC114-7xlplGi09inTBnVovkmRbpnwwHt12c3LbffIZSyUsUh
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-8=-70, 8-12=,70, 12-13=-70, 13-14=-70, 1-P6=-20, 21-26=-20, 19-21=-20, 15,18=-20
Concentrated Loads (lb)
Vert: 15=4(B)
Jo Truss cuss Type
t �
y
y
- T18335963
EO,;♦03091-TNT
Al
ROOF SPECIAL i
1
1
Job Reference (optional)
Q WARNING -Verify des/gn parameters and READ NOTES ON -THIS AND INCLUDED MITEK REFERANCE PAGE MI1-7473 rev. 10/0312015 BEFORE USE.
Design valid for use only with MRek®connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate This design Into the overall
building design. Bracing Indicated is to buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek`
prevent
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the, '
fabrication; storage, delivery, erection and bracing of trusses and truss systems, seeANSUiPII Quality Cdtrrda, DSB•89 and SCSI Bulidlnp Component
6904 Parke East Blvd..
Safety Ntortnatbnovoiloble from Truss Plate Institute, 2113 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610.
Job
Truss
I russ I ype r )
tyPly
T18335964
20403091-TNT
A2
ROOF SPECIAL
1
1
Job Reference (optional)
.umuers mrstoource, run riece, rt- aY �,..��. ,..��..� �.. �.. _.. ... ......... ...___.._._..-'----'-'-_-
ID:PftLgjXzGof3aThkEwERV6zC114-b7sBVcjew7vKmx4_TSHgBOKOwhBhn4BVgJOr5uyUsUg
it-8-0 6-5-4 , 11.2-8 15-11-12 20-9-0 23-2-0 29-10-0 34-0-0 38-9-1039-8�0 44-5-04_$�0
0 1-8-0 4-9-4 4-9-4 4-9-4 4-9-4 2-5-0 6-8-0 4-2-0 4-9-10 0-10-6 4-9-0
5x6 =
Scale = 1:84.1
5.00 12
5x6 8
7
3x4
4x6
28
29 9 . .
6
5x6
410 MT201!S i4x6 i
10
3x6 11
5
21
5x6 = 4x6 =
4x6 4
20
11 12 13
3 22
10x16 MT20HS _
b
23 4x6 %
. 6x8
1
14
27 24
2 6x12 MT20HS % 4.00 1225
7x10
N r
N
1
5x6
18
0
1j
Io
16 15 I�
`] 7x10
0
2x4 I I
5x8 =
ST1.5x8 STP = 4x10 MT20HS I I
- 3x6 — 28
6x8 =
ST1.5x8 STP =
12x14 i
1 B-0
-0-
6-5-4 11-2-6 15-11.12
20-9-0 23-2-29-10 0-
34-0-0
39-6-0
4 -0 1 5-0
-0-
1
4-9-4 4-9-4 4-9-4
4-9-4 2-5.0 0
6-8-0
5-8-0
04 0 4-5-0
0-6-0
Plate Offsets (X,Y)--
[3:0-2-8,6-1-8], [4:0-5-0,Edge], [7:0-1-8,0-1-12], [10:0-3-0,0-3-0],
[13:0-2-8,0-2-0], [15:Edge,0-3-8], [16:0-4-0,0-3-12], [19:0-6-12,0-5-0], [20:0-1-2,0-24],
[25.075-0 0-2-8] [26.0-4-12 Edge]
LOADING'(pso
SPACING- 2-0-0
CSI.
DEFL.
in (loc) I/dell
Lid
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.86
Vert(LL)
-0.64 21-22 >713
360
MT20
244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.60
Vert(CT)
-1.44 21-22 >315
240.
MT20HS
187/143
BCLL 0.0
Rep Stress lncr YES
WB 6.86
Horz(CT)
0.95 16 n/a
n/a
BCDL 10.0
Code FBC2017/TP12014,
Matrix-SH
Wind(LL)
0.8421-22 >539
240
Weight: 278lb
FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 31 'Except` TOP CHORD
11-14,10-11: 2x4 SP No.2
BOT CHORD 2x6 SP,M 26 *Except* BOT CHORD
1-26: 2x4 SP No.2, 9-18: 2x4 SP No.3, 15-18: 2x6 SP No.2 WEBS
WEBS 2x4SPNo.3'Except`
2-26: 2x6 SP No.2, 2-25,7-21: 2x4 SP No.1, 8-20: 2x4 SP No.2
REACTIONS. (lb/size) 26=1822/0-8-0, 16=2219/0-8-0
Max Harz 26=321(LC 12)
Max Uplift 26=-660(LC 12), 16=-893(LC 9)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-444/206, 2-27=-5806/3220; 3-27=-5684/3221, 3-4=-7844/4312, 4-5=-7797/4321,
— 5-6=-7920/4370, 6-28=-6881/3730, 7-286807/3741, 7-8=-3936/2223, 8-29=-3936/2197,
9-29=-4034/2177,'9-10=-3639/1942, 10-11=-1946/864, 11-12=-347/247, 12-13= 273/190
BOT CHORD 1-26=-216/452, 25-26=-319/95, 24-25= 3225/5590, 23-24=-4241/7587; 22-23a-4235/7605,
21-22= 4156/7651, 20-21=-3365/6574, 19-20=-1747/3526, 9-19=-594/477, 16-17=-98/320,
15-16=-190/273
WEBS 2-26=-1554/1116, 2-25=-2938/5356, 3-25— 921/626, 3-24=-973/1925, 5-24=-363/271,
6-21=-1057/731, 7-21= 2341/4464, 8-20= 1409/2653, 9-20=-114/441, 17-19_ 798/1950,
10-19= 950/1663, 10-17=-1643/1021, 11-17= 970/1665, 7-20=4404/2519,
11-16=-1280/441, 12-16=-664/856
Structural wood sheathing directly applied or 2-4-6 oc purlins, except
end verticals.
Rigid ceiling directly applied or 4=9-15 oc bracing.
1 Row at midpt 2-25, 7-20
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf;'BCDL=5.Opsf; h=15ft; Cat. II; Exp C; Encl.,
GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) 0-0-0 to840-0, Interior(1) 6-0-0 to 2372-0, Exterior(2) 23-2-0 to 29-2-0,.Interior(1)
29-2-0.to 45-1-0 zone; cantileverleft and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the.bottom chord in all areas where a rectangle 3-6-0 tall by 2.0-0 wide
will fit between the bottom chord and any othermembers.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 660 lb uplift at joint 26 and 893 Ito uplift at Walter P. Finn PE No.22939
joint-16. p MTek USA, Inc. FL Cert 6634.
$904 Parke East Blvd. Tampa FL 33610,
Date:
LOAD CASE(S) Standard
October 10,2019
Q WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MTTEK REFERANCE PAGEMIP7473 rev. 10103,2015 BEFORE USE.
• Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and Is for an Individual building component not
a truss system. Before use, the, building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing.
M!Tek"
Is always required for stability and to prevent. collapse with possible personal Injury and property damage. For general guidance regarding the .
fabrication; storage; delivery, erection and bracing of trusses and truss systems, seeANSVIPII Quality CrNM, DSB•89 and BCSI Bu6dtng Component
6904 Parke East Blvd.
Safety Informationovollable from Truss Plate Institute; 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610.. .
Job
Truss
t
ty
y
.
�
T18335965
20J03091-TNT
A3
ITrussType
ROOF SPECIAL
1
1
Job Reference (optional)
eumersrustjource,rorrriece,r-LJwe4a—1. 1. <�,� �.�,�,.,,,'..._..._. __._. ,_.
ID:PftLq]XzGog3aT lkEwERV6zC114-3JPaixjHhJlBN5fA19ovgDtCE5XBWWfe2z8PeLyUsUf
1-4-0 6-6-0 11-4-0 11r8-0 i6-2-6 0 �23-2-0 29-10-0 36-9-10' 390 -8-i 44-5-0 4541
1-44-10-0 4-6-8 2�-4-6-86-11-10 2-10-6 4-9-0 0-6-0
5.00 12
3x4
6 26
5x6
3x6 5
3x4 4
3 20
3x12 MT20HS 11 5x6
25
1
' co 1 2 2x4 i 4.00 F12
0 24 23 22
ST1.5x8 STP = 2x4 11- ST1.5x8 STP =
3x6 = 6x8 =
19
5x6 =
5x6 =
7
18
3x4
Scale = 1:82.7
4x6
27 8
Sx12 = 2x4 II 4x6 =
9 10 11
N
26 12 b
� N
1 � u
5x12
0 0
16v 15 14 13 ..
35(4 11 ST1.5x8 STP = 2x4 I I
.3x4 = 6x8 =
1-4-0
-0- 6-6-0 11-4-0 11 -0 16-2-8 20-9-0 25-3-8 29-10-0 36-9=10 39-8-0 4 -0 44-50
5-2-0 - 4-10-0 4 4-6-8 4-6-8 4-6-8 4-6-8 6-11-10 2-10-6 0 4 0 4-5-0
Plate Offsets (X Y)--
[2.0-2-3 1-2-81 [5:0-2-0 0-2-0] [20:0-3-0 0-1-121 [22:03-8 0-3-01
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
. (loc)..
I/dell
Ud
TCLL 2060
Plate Grip DOL 1.25
TG 0.82
Vert(LL)
-0.14
' 19
>999
360
.
TCDL 15.0
Lumber DOL 1.25
BC 0.59
Vert(CT)
--0.33 18-19
>999
240
BCLL 0.0_*
Rep Stresslncr. YES
WB 0.91
Horz(CT)
0.16
14
n/a
n/a
BCDL 10.0
Code FBC2017/fP12014
Matrix-SH
Wind(LL)
0.16
.. 19
.>999
240
PLATES
GRIP
MT20
244/190
MT20HS
187/143
Weight: 249 lb
FT = 20%
LUMBER- "
BRACING -
TOP CHORD' 2x4 SP No.2 *Except
TOP CHORD
Structural wood sheathing directly applied or 2-2-0 oc purlihs, except
4-7: 2x4 SP M 31
end verticals.
BOT CHORD 2x4:SP No.2 *Except .
BOT CHORD
Rigid ceiling directly applied or 5-0-7 oc bracing.
8-16: 2x4 SP No.3
WEBS
1 Row at midpt 5-22.
WEBS 2x4 SP No.3
REACTIONS: (lb/size) 24=535/0-8-0, 22=1732/0-8-0, 14=1775/0-8-0
Max Horz 24=350(LC 12)
Max Uplift 24=-153(LC 8), 22=-720(LC 12), 14=-802(LC 9)
Max Grav 24=541(LC 23), 22=1732(LC 1), 14=1775(LC 1)
FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-328/47, 2-25= 450/223, 3-25=-311/224, 5-6=-2529/1440, 6-26= 3185/1663,
7-26=-3088/1683, 7-27=-2127/1254, 8-27=-2229/1234, 8-9=-2292/1204, 9-28=-507/378,
10-28 507/379, 10-11=-507/378
BOT CHORD 1-24=-53/343, 23-24=-304/354, 22-23= 304/354, 19-20=-1369/24i15, 18-19=-897/2002,
17-18— 1104/2110, 8-17= 463/426„ 14-15— 254/840
WEBS 2-24=-378/485, 3-22=-457/379, 5-20=-1346/2400, 6-20=-735/533, 6-19=-106/624,
7-19=-817/16B7, 7-18==161/278, 8-18=-197/265, 15-17=-270/835, 9-17=-848/1244,
9-14=-1667/880, 10-14=-278/280, 11-14=-472/636, 21-22=-1459/841, 5-21=-1372/838
NOTES-
1) Unbalanced roof.live loads have been considered for this design. .
2) Wind: ASIDE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; Cat. 11; Exp C; Encl.,
GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) 0-0-0 to 6-0-0, Interior(1) 6-0-0 to 23-2-0, Exterior(2) 2372-0 to 29-2-0, Interior(1).
29-2-0 to 45-1-0 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage.to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other liye loads.
6) * This truss has:been designed fora live load of.20.0psf on the bottom chord. in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 153 lb uplift at joint 24, 720 lb uplift at
joint 22 and 802 lb uplift at joint .1.4.
LOAD CASE(S) Standard
Wafter P. Finn PE No.22839
MiTek USA, Inc. FL Cert 6634,
0904 Parke East Blvd. Tampa FL:33610
Date:
October 10,2019
® WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE 111II.7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the. building designer must verify the applicability of design parometers,and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek*
Is always required for stability and to prevent. collapse with possible personal Injury and'property damage. For general guidance regarding the
fabrication; storage, delivery, erection and bracing of trusses and truss systems, seeANSVIPIi Quality Cdloda, DSB-89 and SCSI Building Component.
Safety Infonnationavailable from Truss Plate Institute, 218 N. Lee Street, Suite.312, Alexandria, VA 22314, p.
6904 Parke East Blvd.. -
Tampa, FL 33610 .
Job
Truss
s ype e y
ty
lyT18335966
20403091-TNT
A4
TR',USf
Special
1
1
Job Reference (optional)
_ ... _. ...
Fur!
_,..,.._ o.._.°nnn .. c,.,. BB nn'Q PA..,•° 240 c ua272n1d M' .T IM... hi— 1— Th„In In-12:M 2019 Pana1
.Builders FirsiSuurce, furl Pi-, FL 3Y945 � ,,.,,. �.��., ., � �., � � ,-.. �., . ���......_�., .. ..... ... _...- ..... _. ..___..._-, ..._. ..._ Oct__.. _ . _
ID:PftLgjXzGof3aThkEwERV6zC114-3JPaixjHhJ1 BN5fA1 9ovgDtCj5X3WW W e2z8PeLy0s0f
--6-6-0 -T16-2-B 40-9-0 2-200 29-100 -10_39-1B--06 ' 95--00
40 4-It-4-0 4100 0-0
01 5-2
Scale = 1:82.4
5x6 =
5.00 12 , 7
3x4 4x6 J
6 25 26 B
5x12 = 2x4 11 4x6 =
5x6
3x6 5 18 9 10 11
.3x4 i 4 5x6 = 27
19 17 o
3x12 MT20HS I I 3 5x6 3x4 - m
24 1 d
v
2
0
1 4.00. 12 5x12 19
� 2x4 % 15 14 13,. 12 �
0 23 22 21 2x4 11 3x4 = ST1.5x8 STP = 2x4 II
ST1.5x8 STP= 2x4 11 ST1.5x8 STP= 6x8 =
3x6 = 6x8 =
1-4-0
-0 6-6-0 11-4-0 11 -0 16-2-6 20-9-0 25-3-8 29-10.0 349-10 37-0-0 39-8-04 -0 44-5-0
-0 5-2-0 4-10-0 4 0 4-0-6 4. 4-6-6 46-6 4-11-10 2-2-6 . 2-6-0 0 4 0 4-5-0
0-4-0
Plate Offsets (X Y)-- [2.0-2-3 1-2-8] [5'0-2-0 0-2-0] 1`19.0-3-0 0-1-121 r2l:0-3-8 0-3-01
LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP
TCLL 20.0 Plate Grip DOL 1.25 TC 0.79 Vert(LL) -0.14 - 18 >999 360, MT20 244/190
TCDL 15.0 Lumber DOL 1.25 BC 0.60 Vert(CT) -0.33 17-18 >999 240 MT20HS 187/143
BCLL 0.0 ` . Rep Stress Incr YES WB . 0.92 Horz(CT) 0.17 13 n/a n/a
BCDL 10.0 Code FBC2017/TP12014 Matrix-SH Wind(LL) 0.17 18 >999 240 Weight: 253lb FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 *Except* TOP CHORD Structural wood sheathing directly applied or 2-2-0 ocpuriins, except '
4-7: 2x4 SP M 31 end verticals.
BOT CHORD 2x4 SP No.2 *Except* BOT CHORD Rigid ceiling directly applied or 4-10-10 oc bracing.
8-15.2x4 SP No 3 WEBS 1' Row at midpt 9-13, 5-21
WEBS 2x4 SP No.3 *Except*
11-12: 2x6 SP No.2
REACTIONS. (lb/size) 23=535/0-8-0, 21=1743/0-8-0, 13=1699/0-8-0
Max Horz 23=380(LC-12)
Max Uplift 23=-136(LC 8), 21= 736(LC 12), 13=-749(LC 9)
Max Gram 23=541(LC 23), 21=1743(LC 1), 13=1699(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten.,- All forces 250 (lb) or less except when shown.
TOP CHORD 1-2= 333/11, 2-24= 450/177, 3-24=-310/179, 5-6=-2555/1472, 6-25=-3232/1753;
7-25=-3136/1773, 7-26=-2165/1289, 8-26=-2263/1269, 8-9=-2272/1221, 9-27=-306/186,
10-27=-306/186, 10-11=-306/186
BOT CHORD 1-23=-17/343, 22r23=-316/360, 21-22=-316/360, 18-19=-1455/2430, 17-18=-1002/2037,
16-17=-1175/2202, 8.16=-400/386, 13-14=-504/1188
WEBS 2-23=-378/476, 3-21=-464/392, 5-19— 1426/2424, 6-19= 744/561, 6-18=-158/645,
7-18=-881/1707, 7-17=-141/283; 14-16=-525/1254, 9-16=-593/897, 9-14=-383/284,
9-13— 1724/977, 10-13=-3B5/382, 11-13= 259/432, 20-21=-1470/875, 5-20=-1384/872
NOTES-.
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; Cat. 11; Exp C; Encl.,
GCpi=0.18; MW FRS (envelope) and C-C Exterior(2) 0-0-0 to 6-0-0, Interior(1) 6-0-0 to 23-2-0, Exterior(2) 23-2-0 to 29-2-0, Interior(1)
29-2-0 to 44-2-4 zone; cantilever left and right exposed ;C-C.for members and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 136 lb uplift at joint.23, 736 lb, uplift at
joint 21 and 749 lb uplift at joint 13..
LOAD CASE(S) Standard
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cent 869
6904 Parke East Blvd. Tampa FL 33610.
Date:
-October 10,2019
Q WARNING -Verify deslgn parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE'M11-7473 rev. 1010312016 BEFORE USE.
WEBS 2x4 SP No.3 *Except*
11-12: 2x6 SP No.2
REACTIONS. (lb/size) 23=535/0-8-0, 21=1743/0-8-0, 13=1699/0-8-0
Max Horz 23=380(LC-12)
Max Uplift 23=-136(LC 8), 21= 736(LC 12), 13=-749(LC 9)
Max Gram 23=541(LC 23), 21=1743(LC 1), 13=1699(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten.,- All forces 250 (lb) or less except when shown.
TOP CHORD 1-2= 333/11, 2-24= 450/177, 3-24=-310/179, 5-6=-2555/1472, 6-25=-3232/1753;
7-25=-3136/1773, 7-26=-2165/1289, 8-26=-2263/1269, 8-9=-2272/1221, 9-27=-306/186,
10-27=-306/186, 10-11=-306/186
BOT CHORD 1-23=-17/343, 22r23=-316/360, 21-22=-316/360, 18-19=-1455/2430, 17-18=-1002/2037,
16-17=-1175/2202, 8.16=-400/386, 13-14=-504/1188
WEBS 2-23=-378/476, 3-21=-464/392, 5-19— 1426/2424, 6-19= 744/561, 6-18=-158/645,
7-18=-881/1707, 7-17=-141/283; 14-16=-525/1254, 9-16=-593/897, 9-14=-383/284,
9-13— 1724/977, 10-13=-3B5/382, 11-13= 259/432, 20-21=-1470/875, 5-20=-1384/872
NOTES-.
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; Cat. 11; Exp C; Encl.,
GCpi=0.18; MW FRS (envelope) and C-C Exterior(2) 0-0-0 to 6-0-0, Interior(1) 6-0-0 to 23-2-0, Exterior(2) 23-2-0 to 29-2-0, Interior(1)
29-2-0 to 44-2-4 zone; cantilever left and right exposed ;C-C.for members and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 136 lb uplift at joint.23, 736 lb, uplift at
joint 21 and 749 lb uplift at joint 13..
LOAD CASE(S) Standard
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cent 869
6904 Parke East Blvd. Tampa FL 33610.
Date:
-October 10,2019
Q WARNING -Verify deslgn parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE'M11-7473 rev. 1010312016 BEFORE USE.
*
Design valid for use only with Mliek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the. building designer must verity the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiT®k* -
is always required for stability and to prevent. collapse with possible personal Injury and property damage. For general guidance regarding the,
fabrication; storage; delivery, erection and bracing of trusses and truss systems, seeANSVFPII Quality Criteria, OSB-89 and BCSI BuBding Component.
.
6904 Parke East Blvd.
Safaty Infonnatlonavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. - ..
Tampa, FL 33610
Job
Truss
Truss Type
CRY
Ply
.
T18335967
20,103091-TNT
A5
ROOF SPECIAL
1
1
Job Reference (optional)
nuioers r8sraource, run riece, rL evvya , o,. , , �..,.. , ., ,.,., _...... _ ..... _.....---...__, ...-. .. - --- -- F -- -- --
ID:PftLgjXzGof3aThkEwERV6zC114-XWzywHkvSd927FENbtJeDRPN6UgFFygoHdtyAny sUe
1-4-0 6-6-0 11-4-0 11 -0 16-2-6 20-9-0 23-2-0 29-10-0 32-9-12 37-6-0 42-0-0 44-5-04 -1 0
1-4-0 5-2-0 4-10-0 0 0 4-6-8 - - 4-6-6 2-5-06-8 ;0 2.11-10 4-8-6 4-6-0 2-5-0 -8-
u,
3x4
3
3x12 MT20HS 11
26
1 2
m
0
25 24
ST1.5xB STP = 2x4 11
3x6 =
. Scale = 1:82.7
5x6 =
5.00 12 '7
23
ST1.5x8 STP =
6x8 =
17 16
2x4 II 5x8 =
5x6 =
46
M\ 12
13
31 15 14
5x8 = 3x6 II
1-4-0
1-0- 6-6-0 11-4-0 11 -0 16-2-8.20-9-0 25-3-8 29-10-0 32-9.10 42-0-0 44-5-0
4-0 5-2-0 4-10-0 4 4-6-8 4-6-8 4-6-8 2-11-10 9-2-6 2-5-0
0-4-0
r9•n-9-a_1-2-8t n t0-s-n.0-2-41. fl6:0-2-8.0-2-01. 118:0-6-8.0-1-41. 120:0-3-11.0-2-81, f23:0-3-8,0-3-01
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)..
Udefl
Ud
TCLL
20.0
Plate Grip DOL
1.25
TC 0.81
Vert(LL)
-0.23 119
>999
360
TCDL
15.0
Lumber DOL
1.25
BC 0.79
Vert(CT)
-0.52 18-19
>754
240
BCLL
0.0
Rep Stress Jncr
YES
WEI 0.98
Horz(CT)
0.27 14
n/a
n/a
BCDL
10.0
Code FBC2017/TPI2014
Matrix -Sit
Wind(LL)
0.29 18-19
>999
240
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2'Except* TOP.CHORD
4-7: 2x4 SP M 31, 7-9: 2x4 SP No.1
BOT CHORD 2x4 SP No.2'Except* BOT CHORD
8-17: 2x4 SP No.3 WEBS
WEBS 2x4 SP N6.3 `Except'
5-21,16-18: 2x4 SP No.2
REACTIONS. (lb/size) 14=1523/Mechanical, 25=522/0-8-0, 23=1996/0-8-0
Max Harz 25=367(LC 12)
Max Uplift 14=-588(LC 13), 25=-141(LC 8), 23=-786(LC 12)
Max Grav 14=1523(LC 1), 25=533(LC 23), 23=1996(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2= 314/19, 2-26=-435/212, 3-26=-295/214, 5-6=-3086/1876, 6-27=-4159/2406;
7-27=4064/2426, 7-28=-3013/1910, 8-28=-3108/1890, 8-9=-3428/2115, 9-29=-1862/1202,
10-29=4862/1202, 10-11=-578/454, 11-12=-655/454, 12-14=-154011027
BOT CHORD 1-25= 26/329, 24-25=-288/342, 23-24=-288/342, 20-21=-1761/2943, 19-20=71412/2704,
18-19=-1974/3383, 16-30=-832/1351, 30-31=-832/1351, 15-31=-832/1351
WEBS 2-25=-377/485, 5-21=-1757/2964', 6-21=-933/677,6-20=-383/996, 7-20=-1118/2099,
7-19= 396/644, 8-19=-532/491, 16-18= 1616/2829, 9-18=-991/1660, 9-16= 2606/1593,
10-16= 417/834, 10-15=-1297/856, 12-15=-725/1299, 3-23=-461/375,.22-23==1726/1038,
5-22=-1621/1022 .
PLATES GRIP
MT20 244/190
MT20HS 187/143
Weight: 271 lb FT = 20
Structural wood.sheathing directly applied or 1-7-8 oc purlins, except
end verticals.
Rigid ceiling directly applied or 4-2-13 oc bracing.
1 Row. at midpt 9-16, 10-15, 5-23
NOTES-
1) Unbalanced roof live loads have been Considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph`, TCDL=4.2psf; BCDL=5.Opsf; h=15ft; Cat. II; Exp C;.Encl.,
GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) 0=0-0 to 6-0-0, Interior(1) 6-0-0 to 23-2-0, Exterior(2) 23-2.0 to 29-2-0, Interior(1)
29-2-0 to 42-0-0, Exterior(2) 42-0-0 to 45-1-0 zone; cantilever left and right exposed.;C-C for members and forces &.MWFRS for
reactions shown; Lumber DOL=1.60:plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 Mall by 2-0=0 wide
will fit between the bottom chord and any other members, with BCD = 10.Opsf.'
7) Refer to girder(s) for truss to truss connections.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 588,lb uplift at joint 14, 141 lb uplift at
joint25 and 786 lb uplift at joint 23.
LOAD CASE(S) Standard
Walter P. Finn PE No.22839 -
MiTek USA, Inc. FL Cart 669.
6904Parke East Blvd. Tampa FL 33610'
Date:
October 10,2019
WARNING - Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGEMII-7473 rev. 10103I2015 BEFORE USE.wit
Design valid for use only with MITekfel connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a,truss system. Before use, the building designer must verity the applicability of design parameters.and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the.
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVIPII Quality Cdleda, DSB-69 and BCSI BuIlding Component
6904 Parke East Blvd..
Safety Infonnatlonavallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610 .
Job
Truss
russ ype i +
ty
y
T1B335968
20403091-TNT
A6 T
ROOF SPECIAL
1
1'
-
nali
Job Reference o ! -1.
Buuaers Firstsource, Fort Piece, FL 34945
.3
nun: 6.44u 6 v c a�
ID:PftLgiXzGof3aThkEwERV6zC114r?iXK7d[XDwH SPpZBagNIeyY_uAF_P1xWHdWiDyUsUd
-0 6-6-0 11=4-0
11r6-0 16-2-8 23-2-0 29-10-0 32-3-10 36-10-13 41-6.0 44-5-0 4Q-1r0
1-4-0 5-2.04-10-0
0-4-0 4-6-B 6-11-8
6-8-0 2-5-10 4-7-3 4-7-3 2-11-0
Scale = 1:82.7
5x6 =
5.00 12
7
..
3.4
4x6
27
28 8. 5x6 = 5x6 = -
6
3x4 =
- -
5x8 i
9 .. 4x6
. .3x6 %
5
29 1 12
20 13
3x4 4
5x8 I[
3
21
19 N
NI 3x12 MT20HS I!
5x6
3x4
26
1 2
2
4.00 12
O
Sx12
m
2x4
o 25 24
23
17 16 30 31 15 14
ST1.5x8 STP = 2x4 I I ST1.5x8
STP =
2x4 I 4x12 = 5x8 = 3x6 11
3x6 =
6x8 =
1-4-0
1-0- 6-6-0 11-4-0
11 -0 16-2-8 20-9-0
25-3-6 29-10-0 32-3-10 41-6-0 445-0
-0- 5-2-0 4-10-0
0-4 0 4-6-a 4-6-8
4-6-e 4-6-6 2-5.10 9-2-6 2-11-0
0-4-0
Plate Offsets (X Y)-- [2.0-2-3 1-2-8] [11.0-3-0 02-4] [16:0-5-0
0-1-12] [18:0-7-12 0-0-4] [20:0-3-11 0-2-8] [23:03-8 0-3-01
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in . ([cc) Udefl Ud
PLATES GRIP
TCLL 20:0
Plate Grip DOL 1.25
TC 0.81
Vert(LL) -0.24 18-19 >999 360;
MT20 244/190
TCDL 15.0
.
Lumber DOL 1.25
BC 0.81
Vert(CT) _ -0.55 18-19 >719 240
MT20HS 187/143
BCLL 0.0
Rep Stress Incr YES
WB 0.99
Horz(CT) 0.28 14 n/a - n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix-SH
Wind(LL) 0.3d 18-19 >999 240
Weight:271 lb FT=20%
-.LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2 *Except*.
TOP CHORD Structural wood.sheathing directly applied or 2-2-0 cc purlins, except
4-7: 2x4 SP M 31, 7-9: 2x4 SP No.1
end verticals.
BOT CHORD 2x4 SP No.2 *Except*
BOT CHORD Rigid ceiling directly applied or 4-2-5 oc bracing.
8-17. 2x4 SP No
WEBS I Row at midpt 9-16, 10-15
WEBS 2x4 SP No.3 *Except*
5-21,16-18: 2x4 SP No.2
REACTIONS. (lb/size) 14=1523/Mechanical, 25=521/0-8-0, 23=1998/0-8-0
Max Horz 25=367(LC 12)
Max Uplift 14=-588(LC 13), 25=-141(LC 8), 23=-787(LC 12)
Max Grav 14=1523(LC 1), 25=532(LC 23), 23=1998(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less'except when shown.
TOP CHORD , 1-2=-312/19, 2-26=-433/215, 3-26=-294/217, 5-6=-3082/1881, 6-27=-4155/2413,
7-27= 4061/2433, 7-28=-3012/1921, 8-28=-3108/1901, 8-9=-3472/2168, 9-29=-1832/1206,
10-29=-1832/1206, 10-11=-659/525, 11-12=-750/520, 12-14=-1527/1045
BOT CHORD 1-25=728/328,24r25=-285/341, 23-24=-285/341, 20-21=-1760/2939, 19-20— 1413/2703,
18-19= 2009/3428, 18-30=-855/1386, 30-31=-855L1386, 15-31=-855/1386
WEBS 2-25=-377/486, 5-21=-1759/2964, 6-21=-933/678, 6-20=-383/997, 7-20=-1117/2096,
7-19=-403/645, 8-19= 590/535, 16-18=-1805/3151, 9-18=-1205/2004, 9-16=-2991/1818,
10-16= 3711754, 10-15=-1230/813, 12-15=-727/1281, 22-23=-1728/1041, 5-22=-1621/1023,
2 Rows at 1/3 pts 5-23
3-23=-461/373
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; Cat. 11; Exp C; Encl.,
GCpi=0.18; MWFRS (envelope) and C-C Exterior(2):0-0-0 to 6-0-0, Interior(1) 6.0-0 to 23-2-0, Exterior(2) 23-2-0 to 29-2-0, Interior(1)
29-2-0 to 41-6-0, Extedor(2) 41-6-0 to 45-1-0 zone; cantilever left and right exposed ;C-C for members and forces &.MWFRS for
reactions shown; Lumber DOL=1.60.plate grip DOL=1.60
3) Provide adequate drainage to prevent water.ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom, Chord live load nonconcurrent with any other live loads.
6) *.This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
,will fit between the bottom chord and any other members,, with BCD = 10.Opsf.
7) Refer to girder(s) for truss to truss connections:
8) Provide mechanical connection (by others) of truss to bearing plate capable of, withstanding 588.II5 uplift at joint 14, 141 lb uplift at
joint 25 and 787 lb uplift at joint 23.
LOAD CASE(S) Standard
Waller P. Finn PE No.22639
MiTek USA, Inc. FL Cert 6614
6904 Parke East Blvd. Tampa FL 334%
Date:
October 10,2019
WARNING -Verify design parameters and READ NOTES ONTHIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. f0/03/2015 BEFORE USE.
Design valid for use only with MITek® connectors. This deslgn Is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the, building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.. Additional temporary and permanent bracing
MOW
Is always required for stability and to prevent. collapse with possible personal Injury and property damage. For general guidance regarding the -
fabrication, storage; delivery, erection and bracing of trusses and truss systems, seeANSIMII Cuailty Criteria, DSB•69 and. BCSI Building Component.
Tamp Parke East Blvd.
Safety Informatlo availoble from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Tampa,
FL 33610
Job
Truss
Truss Type 4
Qty
Ply
T18335969
20403091-TNT
A7 .
ROOF SPECIAL
1
1
Job Reference (optional)
nwiaers r0smource, roa riece, rLJ4a40 1.--1. , 1"...,. ,.._.._.._ ._.._..._ __._ . _a_ .
I D:PftLgjXzGof3aThkEwERV6zC114-?iXK7dlXDwHvdPpZBagNleyVuuAw_P. XXW HdW i DyUsUd
44-5-0
�1-4-0 6-6-0 11-4-0 11 B-0 16-2-8 20.9-0 23-2-0 i:' . 29-10-0 i 34-3-10 42-6-0 43-6-0 4y5-1,0
` 1-4-0 5-2-0 :4-10-0 0-4 0 .4-6-B, 4-0-0 2-5-0 6-8-0 4-5-10. 8-2-6 . t-0-0 0-8-0
0-11-0
5x6 =
5.00 12 8
3x12 MT20HS 11
32
1 2!/
. 26 25 24
ST1.5x8 STP = ST1.5x8 STP =
3x6 = US =
27
5x12 =
Scale = 1:86.6
15 16 14
5x6 =
3x6 11
1-4-0
-0- 6-6-0 11.4-0 11 -0 16-2-8 20-9-0 25-3-8 29-10-0 33-8-0 3-1 42-6-0 44-5-0
-0 5-2-0 4-10-0 0 4 0 4-6-8 4-6-8 4-0-8 4-6-B 3-10-0 7-10-0 1-11-0
n-4-n 0-4.6
Plate Offsets (X Y)--
[2:0-2-3 1-2-81 [10:0-2-12 0-2-81
[11:0-4-0 0-2-2] [19.0-5-12 0-3-4] [24:0-3-8 0-3-01
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in . (loc).
. I/deft
Lid
PLATES
GRIP
TCLL 20_.0
Plate Grip DOL 1.25
TC 1.00
Vert(LL)
-0.32 16-17
>999
360
MT20
244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.83
Vert(CT)
-0.73 16-17
>541
240
MT20HS
187/143
BCLL 0.0 '
Rep Stress Incr YES
WB 0.99
Horz(CT)
0.29 14
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix-SH
Wind(LL)
0.31 20' .
>999
240
Weight: 276 lb
FT = 20%
LUMBER -
TOP CHORD 2x4 SP N0.2 'Except'
8-10: 2x4 SP No. 1, 10711: 2x6 SP No.2
BOT CHORD' 2x4 SP No.2 *Except*
9-27,15-29: 2x4 'SP No.3, 28-30: 2x4 SP M 31
WEBS 2x4 SP,No.3 *Except*
5-22,17-19,5-24: 2x4 SP No.2,
BRACING -
TOP CHORD - Structural wood sheathing directly applied, except end verticals.
BOT CHORD Rigid ceiling directly applied or 4-1-15 oc bracing.
WEBS 1 Row at midpt12-14, 5-24, 11-17
REACTIONS._ (lb/size) 14=1555/Mechanical, 26=515/0-8-0, 24=2007/0-8-0
Max Harz 26=367(LC 12)
Max Uplift 14--570(LC 13), 26=-138(LC 8), 24=-791(LC 12)
Max Grav 14=1555(LC 1), 26=526(LC 23), 24=2007(LC 1)
FORCES.. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2— 304/15, 2-32=-422/188, 3-32=-283/190, 5-6=-3016/1736, 6-33=-4214/2440;
7-33=-4147/2453, 7-8= 4163/2578, 8-34=-3000/1854, 9-34=-3099/1834, 9-1 0=-3691/21 9 1,
10-11— 2326/1350, 14-16=-1520/947
BOT CHORD 1-26= 22/318,25-26=-283/331, 24-25=-283/331, 21-22— 1626/2867, 20-21— 1352/2685,
19-20=-2046/3545, 16-17=-178/306
WEBS 2-26=-376/482, 5-22=-1649/2934, 6-22=-921/637, 6-21=-529/1127, 7-21=-228/305,
8-21=-1376/2264, 8-20=-389/648, 9-20=-733/608,'17-19=-1465/2682, 10-19=-711/1177,
3-24=463/378123-24=-1736/1039, 5-23=-1617/1016, 10-17=-2309/1477,
11-16=-1600/1136, 11-17=-1245/2247
NOTES-'.
1) Unbalanced, roof live loads have been considered for this design..
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; Cat. 11; Exp C; Encl.,
GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) 0-0-0 to 6-0-0, Interior(1) 6-0-0 to 23-2-0, Exterior(2) 23-2.0 to29-2-0, Interior(1)
29-2-0 to 43-6-0, Exterior(2) 43-6-0 to 45-1-0 zone; cantilever left and right exposed ;C-C for members and forces &.MWFRS for
reactions shown; Lumber DOL=1.60 plate.grip DOL=1.60
3) Provide adequate drainage to prevent water.ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) All plates are 2x4 MT20 unless otherwise indicated.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) *This truss has been designed for alive load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any-othermembers.
8) Refer to girder(s) for truss to truss connections.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 570 lb uplift at joint 14, 1.38 lb uplift at
joint 26 and 791 lb uplift at joint 24.
LOAD CASES) Standard
Walter P. Finn PE No.22839
MiTek USA, Iric. FL Cert 6634.
6904 Parke East Blvd. Tampa FL 33610
Date:
October 10,2019
Q WARNING- Verity design parameters and READ NOTES ON THIS AND INCLUDED MrrEK REFERANCE PAGE Mll-7473 rev. 1W03/2015 BEFORE USE
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a.truss system. Before use, the. building designer must verify the applicability of design parameters.and properly incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only.. Additional temporary and permanent bracing.
MiTek"
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSM11 Cuatlly Criteria. DSB-69 and BCSI Building Component
satmty Informationovallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
.
6904 Parke East Blvd.
Tampa, FL 33610.
Job
russ
Truss Type
Qty
Ply
T18335970
20403091-TNT
AS .-
ROOF SPECIAL
1
1
Job Reference (optional)
numers r-irsmource, non niece, M u4e4a ,,. ,., �..,,, , ,.y.. .
ID:PftLgjXzGof3aThkEwERV6zC114-Tu5iLzm9_EPIEZOIiIMcIsVhFIV4;i 41xM EgyUsUc
45-1-0
11-4-0 11re-0 16-2-9 21-0.0 25-4-0 29-10-0 34-e-0' ,363-10 42-6-0 44-5-0
4-10.0 0 4-6-8 -4-9-e 4-4-0 4-.10-0 1-7-10 6-2-6 1-11-00-e-0
Scale = 1:81.1
5x6 =
5x8 =
5.00 12 7 8
3x12 MT20HS 11
30
2
29 28 27
ST1.5x8 STP = ST1.5x8 STP =
3x6 = 6x8 =
21
17
20
8x14 MT20HS =
14 15 13
3x6 11
3x4 =
14-0
..
36-6-0 .
1-0-
6-6-0 11-4-0 11 -0
16-2-8 20-9-0
25-4-0
29-10-0
348-0
6-3-10 42-6-0
44-5-0
-O-
5-2-0 4-10-0 4
4-6-8 4-6-8
4-7-0
4-6-0
4-10-0
1-7-10 6-0-0
1-11-0
0-4-0
0-2-6
Plate Offsets (X Y)--
[2.0-2-3 1-2-8] [7.0-3-0 0-2-41 [8.0-5-12 0-2-8] [11'0-3-8 0-2-8]
[27:0-3-8 0-3-01
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in . (loc)
I/deft
Ud
PLATES
GRIP
TCLL 20:O
Plate Grip DOL 1.25
TC 0.90
Vert(LL)
-0.26 22-23
>999
360.
MT20
244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.82
Vert(CT)
-0.59 22-23
>665
240
MT20HS
187/143
BCLL 0.0
Rep Stress Incr YES
WB 0.99
Horz(CT) .
0.28 13
n/a
- n/a
BCDL 10.0
Code FBC2017ITP12014
Matrix-SH
Wind(LL)
b.33 22-23
>999
240
Weight: 262lb
FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 *Except* TOP CHORD
8-10: 2x4 SP No. 1, 10-12: 2x4 SP M 31
BOT CHORD 2x4 SP No.2 `Except BOT CHORD
9-21,18-20,14.16: 2x4 SP No.3 WEBS
WEBS 2x4 SP No.3 *Except*
11-13,5-25,5-27 2x4 SP No.2
REACTIONS. (lb/size) 13=1521/Mechanical, 29=515/0-8-0, 27=2006/0-8-0
Max Harz 29=339(LC 12)
Max Uplift 13=-573(LC 13), 29= 141(Lb 8), 27=-749(LC 12)
Max Grav 13=1521(LC 1), 29=525(LC 23), 27=2006(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. = All forces 250 (lb) or less except when shown.
TOP CHORD 1-2= 299/12, 2-30=-419/184, 3-30=-280/185, 5-31= 3012/_1872, 6-31=-2913/1887,
64=4202/2595, 7-8=-3693/2409, 8-9= 3123/2023, 9-32=-3442/2254, 10-32=-3595/2244,
10-11=-2371/1.411, 13-15=-1477/916, 11-15==1427/934
BOT. CHORD 1-29=-19/315, 28-29=-281/327, 27-28=-281/327, 24-25=-1799/2863, 23-24=-1685/2989,
22-23=-2102/3427 .
WEBS 2-29=-375/481, 3-27=-457/378,,5-25=-1816/2929, 6-25=-920/698, 6-24=-565/1136,
7-24=-698/1285, 8-24=-660/993, 8-23=-240/428, 9-23=517/453, 17-22=-1547/2603, '
10-22=-536/805, 10-17=-1963/1351, 26-27=-1735/1112, 5-26=-1616/1088,
11-17=-1498/2505
Structural wood sheathing directly applied or 2-2-0 oc purlins, except
end verticals.
Rigid ceiling directly applied or 4-1-1 oc bracing.
1 Row at midpt 17-22, 547, 11-17
NOTES-.
1) Unbalanced, roof.live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; Cat. 11; Exp C; Encl.,
GCpj=0.18; MWFRS (envelope) and C-C Exterior(2) 0-0-0 to 6-0' 0, Interior(1) 6.0-0 to 21-0-0, Exterior(2) 21-0-0 to 31-4-0, Interior(1)
31-4-0 to 45-1-0 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water.ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) All plates are 2x4 MT20 Unless otherwise indicated.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) • This truss has been designed for a live load of 20.Opsf on:the:bottom chord in all areas where a rectangle 3-6-0 tall by 2-0=0 wide
will fit between the bottom chord and any othermembers.
8) Refer to girder(s) for truss to truss connections. .
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 573 lb uplift at joint 13, 141. lb uplift at
joint 29 and 749 lb uplift at joint 27.
LOAD CASE(S) Standard
Walter P. Finn PE No.22839
MiTek USA, Iric. FL Cert $634
6904 Parke East Blvd. Tampa FL 33610
Date:
October 10,2019
0 WARNING -Verify design parameters and READ NOTES ON, THIS AND INCLUDED MITEK REFERANCE PAGE111I1-7473 rev. 1WO312015 BEFORE USE.
•
• "Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a.truss system. Before use, the. building designer must verify the applicability of design parameters, and properly Incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MIT®k� '
Is always requlred for stability and to prevent -collapse with possible personal Injury and property damage. For general guidance regarding the:
fabrication, storage; delivery, erection and bracing of trusses and truss systems, seeANSVTPIt Qualify Crlfrada, DSB-89 and BCSI Building Component'
6904 Parke East Blvd.. "
Safety Infarmationavallable from Truss Plate Institute: 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Fruss
Truss Type
Qty
Ply
•
T18335971
20403091-TNT
A9
ROOF SPECIAL
1
1
Job Reference (optional)
eu9aers mrscaource, rorc riece, rL a4a40 —1.. — , I �,.,.. .,.,., �, �.,,.. ,.,,, _.... __._ . _a_ .
ID:PftLgjXzGof3aThkEWERV6zC114-x5f4YJmnlYiaiyyG?trr31 w3iggSJcEza6cn6yUsUb
45-1-0
it-4-0 6-0-0 11-4-0 11 3-0 16-2-6 19-0-0 23-2-0 27-4-0 29-10-0 348-0 35-6-0 38-3-10 �_ 42-0-0
1.4-0 5-2-0 4-10-0 040 4-6-8 2-9-8 42-0 4-2-0 2-6-0 4-10-0 -0-0 2-7-10 4-2-6 1-11-00-8-0
Scale = 1:79.1
5x6 =
5.00 12
3x6 = 5x6 =
7 34 8 35. 9 4x6
0
0
N
31 30 29 23
225x12 = 16 11 15
ST1.5x8 STP = ST1.5x8 STP =
3x6 I I
3x6 = 6x8 =
5x6 =
3x12 MT20HS I I
1-4-0
1 6-6-0 11-4-0 11 -0 16-2-8 - 20.9-0 27-4-0 29-10.0 34-8-0
38-6-0
5-8 38-3-10 42-6-0 445-0
-0 5-2-0 4-10.0 0 0 4-6-6 4-6-8 6.7-0 2-6-0 4-10-0
-0- 2-7-10 0- -6 4-0-0 1-11-0
0-4-0
Plate Offsets (X Y)-- [7.0-3-12 0-2-81 [9.0-3-0 0-2-4] [13.0-0-8 0-1-8] [24.0-6-8 0-1-12] [29:0-3-8 0-3-01 [31:0-2-7 Edge]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/deft
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TIC 0.7.0
Vert(LL) -0.31 25-26 >999
360 p
MT20 244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.86
Vert(CT) _ -0.74 25-26 >532
240
MT20HS 187/143
BCLL 0.0
Rep Stress Incr YES
WB 0.98
Horz(CT) 0.38 15 n/a
n/a
BCDL 10.0
Code FBC2017lTP12014
Matrix-SH
Wind(LL) 0.4025-26 >994
240
Weight: 263lb FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood_sheathing directly applied or 2-2-0 oc purlins, except
BOT CHORD 2x4 SP No.2 *Except* end verticals.
24-26: 2x4 SP No.1, 10-23,20-22,16-18: 2x4 SP No.3 BOT: CHORDRigid ceiling directly applied or 3-11-7 oc bracing.
WEBS 2x4 SP No.3 *Except' WEBS 1 Row at midpt
19-24, 5-29, 12-17
13-15,5-27,5-29: 2x4 SP No.2
REACTIONS. (lb/size) 15=1517/Mechanical, 31=504/0-8-0, 29=2020/0-8-0
Max_Horz 31=293(LC 12)
Max Uplift 15=-556(LC 13), 31=-152(LC 8), 29= 700(LC 12)
Max Grav:15=1517(LC 1), 31=514(LC.23), 29=2020(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2= 278/31, 2-32=-398/213, 3-32=-259/215, 5-33=-2942/1841, 6-33= 2856/1855,
6-7= 2897/2004, 7-34=-5265/3237, 8-34=-5264/3237, 8-35=-3038/2092, 9-35=-3038/2092, .
9-1 0=-3296/2210,10-36=-3467/2316, 11-36=-3543/2305, 11-12= 2577/1590,
15-17=-1473/935, 13-17=-288/245
BOT CHORD 1-31= 38/295, 30-31=-255/304, 29-30=-255/304, 27-28=-293/175, 26-27=-2080/3650,
25-26=-2558/4408, 24-25=-2064/3366, 18-19=-1526/2444, 17=18=-1492/2512
WEBS 5-27=-1748/2905, 6-27=-231/361, 7-27=-1301/681,,7-26=-1454/2573, 8-26=-686/1357,
8-25— 1581/1045, 9.25=-667/1045, 10-25= 305/359, 19-24— 1567/2554, 1"1-24=-549/863,
2-31— 375/490, 3-29=-447/361, 28-29= 1752/1146, 5-28=-1619/1.112, 11-19— 867/678,
12-17=-2592/1659
NOTES-
1) Unbalanced roof live loads have been considered for this design.,
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph;'TCDL=4.2psf; BCDL=5.Opsf; h=15ft; Cat. II; Exp C; Encl.,
GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) 0-0-0 to 6-0-0, Interior(1) 6-0.0 to 19-0-0, Exterior(2) 19-0-0 to 25-0-0, Interior(1)
25-0-0 to 27-4-0, Exterior(2) 27-4-0 to 33-4-0, Interior(1) 33-4-0.1to 45-1-0 zone; cantilever left and right exposed ;C-C for members
and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate gdp.DOL=1.60
3) Provide adequate drainage to prevent water.ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) All plates are 2x4 MT20 unless otherwise indicated.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) ' This truss has been designed for a live load of 20.Opsf on the:bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
8) Referto girder(s) for truss to truss connections.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 556 lb uplift at jbint 15, 152 lb uplift at
joint 31 and 700 lb uplift at joint 29.
' LOAD CASE(S) Standard
Walter P. Finn PE No.22839
MiTek USA, Iric. FL Cert 66U
6904Parke East Blvd. Tampa FL 3361Q
Date:
October 10,2019
0 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MTTEK REFERANCE PAGE MX7473 rev. 1WOM2015 BEFORE USE.
Design valid for use only with MRek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
��
a truss system. Before use, the building designer must verity the applicability of design parameters.and properly Incorporate this design Into the overall
building deslgn. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only.. Additional temporary and permanent bracing
MOW
Is always.required for stability and to prevent, collapse with possible personal Injury and property damage. For'general guidance regarding the .
fabrication, storage; delivery, erection and bracing of trusses and truss systems, seeANSVrPII Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd..
Safety Infonmatlanavaliabie from Truss Plate Institute; 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610 .
Job
I russ
I russ I ype
City
Ply
T18335972
20403091-TNT
A10
ROOF SPECIAL GIRDER
1
1
Job Reference (optional)
cwiaers rirstSource, Fort Fiece, FL 34945 nuu: D. u 6 rru [ I <u 1u r��rn: D-4v 5.,U, �, �..,� ,,,....c. , �s� ,
ID:PftLgjXzGof3aThkEwERV6zC114-OHDTmfW rgTUsX8giO4NHa3x6BSBnYNCErAJYydiia
'it-4-0 6-6-0 i 11-4-0 11r6-0 17-0-0 r18.9-9i20-9-0 22-8-7 25-0-B 29-4-0 29r10-0 34-8-0 40-3-10 44-5-0_4Q�0
1-4-0 5-2-0 4-10-0 0-4-0 5-4-0 1.9-9 1-it-7 1-11-7 2-4-1 4-3-8 0-6-05-7-10 4.1
Scale = 1:82.9
6x12 MT20HS =
5.00 12 5x6 = 2x4 II
4x12 = 2x4 fl 5x6 =
6. 7 8 9 10 11
3x6 6x8 3x4
5 21 12 Special
3x4 i�-
4 5x6 = 2x4 I
22
3 722 Bxl4MT20HS= 20 13 Special 14 rn r`
4x12 .7 ^
2x4 II 1 15
3 7x10 —' o
m t 2 3x6 � 4.. 12 co
14
0
26 .. 25 24 18 17 28 16
ST1.5xB STP= 2x4 II ST1.5x8 STP= 2x4 II 5xl2 = NAILED 6x8 =
3x6 = 6x8 = NAILED
2x4 11
1-4-0
11-4-0 11 -0 17-0-0 20-9-0 25-0-8 29-10-0 34-6-0 44-5-0
-0 5-2-0 4-10-0 0 4 0 5-0-0 3-9-0 4-3-a 4-9-8 410-0 9-9-0
0.4-0
Plate Offsets (X Y)-- [6'0-3-0 0-2-4] [7.0-5-8 0-3-0] [10'0-3-12 0-2-81 [1 9'0.2-4 0-5-0] [21:0-7-0 0-5-4] [24:0-3-8 0-3-01
LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP
TCLL 20:0 Plate Grip DOL 1.25 TIC 0.82 Vert(LL) -0.49 20-21 >806 360 MT20 244/190
TCDL 15.0 Lumber DOL 1.25 BID ; 0.77 Vert(CT)- -1.11 20-21 >357 240 MT20HS 187/143
BCLL 0.0 Rep Stress Incr NO WB 0.94 Horz(CT) 0.54 16 n/a n/a
BCDL 10.0 Code FBC20171f P12014 Matrix-SH Wind(LL) 0.59 20-21 >667 240 Weight: 266 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 *Except* TOP CHORD Structural wood sheathing directly applied or 1-9-15.oc purlins,
4-6: 2x4 SP No.1, 6-10: 2x4 SP M 31 except end verticals.
BOT CHORD 2x6 SP M 26 'Except' BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
1-24: 2x4 SP No.2, 11-18: 2x4 SP No.3, 16-18: 2x4 SP NoA WEBS 1 Row. at midpt 13-16, 5-24
WEBS 2x4 SP.No.3 *Except*
5-22: 2x4 SP No.2, 5-24,8-21,7-21: 2x4 SP No.1
REACTIONS. (lb/size) 16=1537/Mechanical, 26=468/0-8-0, 24=2067/0-8-0
Max Horz 26=246(LC 8)
Max Uplift 16=-669(LC 5), 26— 156(LC 27), 24=-663(LC 5)
Max Gray.16=1537(LC 1), 26=480(LC 19), 24=2067(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-333/131, 4-5=-56/278, 5-6=-3281/1089, 6-7=-3003/1057, 7-8=-9927/3293,
8-9=-4936/1750, 9-10=-4936/1750, 10-11=-3463/1255, 11=12=-3534/1224,
12-13= 221W742
BOT CHORD 22-23=-483/161, 21-22= 1600/5122, 20-21=-2240/6922, 19-20=-1029/3338,
17-28=-691/1818, 16-28=-601/1818
WEBS 2-26=-373/258, 5-22=-992/3381, 6-22=-282/1016, 9-20=-287/181, 10-20=-669/2008,
17-19= 755/2436, 12-19=-392/1279, 12-17- 1344/522, 13-16=-2150/835, 3-24=-422/269,
23-24=-1808/602, 5-23— 1595/574, 8-20=-2311/789, 8-21=-1067/3641, 7-22==3007/1038,
7-21— 1729/5498
NOTES-
1) Unbalanced roof live loads have been considered for this design.,
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; Cat. II; Exp C; Encl.,
GCpi=0.18; MW FRS (envelope); cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. -
6) ' This truss has been designed for live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Refer to girder(s) for truss to truss connections.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 669 lb uplift at joint. 16, 156 lb, uplift at
joint 26 and 663 lb uplift at joint 24.
9) "NAILED" indicates 3-10d (0.148"x3") or3-12d (0.148"x3.25") toe -nails per NDS guidlines.
10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)'44 lb down and 63 lb up at
42-3-4, and 19 lb down and 20:Ib up at 45-1-0 on top chord: The design/selection of such connection devices). is the responsibility
of others.
' :11) In the LOAD CASE(S) section, loads applied to the face of the truss are.noted as front (F) or back (B)..
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cert 6634:
8904 Parke East Blvd. Tampa FL 33610.
Date:
October 10,2019
0 WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MIP7473 rev. fa,=015 BEFORE USE
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the. building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss.web and/or chord members only.- Additional temporary and permanent bracing.
WOW
Is always required -for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the:
fabrication; storage, delivery, erection and bracing of trusses and truss systems, seeANSVFPII Quality Crtterla, DSB-89 and BCSI BuOding Component:
. -
6904 Parke East Blvd.
Safety Informationovallable from Truss Plate Institute; 218 N. Lee Street, Suite 312. Alexandria, VA 22314. ..... .....
Tampa, FL 33610, . .
Job
Truss
Truss Type
Qty
Ply
T18335972
20103091-TNT
A10 -
ROOF SPECIAL GIRDER
1
1
Job Reference (optional)
ommers nrsiaowce, ron nece, r�.avaya , , r „ . ,
ID:PftLgiXzGof3aThkEwERV6zCll4-0HDTmfnPVrgTUsX8giO4NHa3x6BSBnYNCErAJYy sUa
` LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-6=-70, 6-10=-70,.10-13=-70, 13-14=-70, 14-15=-70, 1-24=-20, 21-23=-20119-21=-20, 16-18=-20
Concentrated Loads (lb)
Vert: 16=-29(F) 28=-2(F)
A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE'M11.7473 rev. 11V03/2015 BEFORE USE.
Design valid for use only with MI1ek® connectors. This design Is based only upon parometers'shown, and Is for an Individual building component, not
o,truss system. Before use, the. building designer must verify the applicability of design parameters,and properly Incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing.
M!Tek*
Is always.required for stability and to prevent.collapse with possible personal Injury and property damage. For general guidance regarding the:
fabrication; storage; delivery, erection and bracing of trusses and truss systems, seeANSVIPII Quality Cdleda, DSB-89 and BCSI Bullding Component:
.
6904 Parke East Blvd.
Safety Informatlohavallable from Truss Plate Institute; 218 N. Lee Street, Suite 312, Alexandria, VA 22314. .. .... . ...
Tampa, FL 33610.
Job
russ
Truss Type
Qty
Ply
T1B335973
20W3091-TNT
61
Hip Girder
1
1
Job Reference (optional)
cumars ruscocurce, run riece, rL evav0 nun. o.— a i r . 41 „ y=
ID:PftLgIXzGof3aThkEwERV6zC114-uTnrz7o1G9oK506KNQvJ.wU7DmW,KwD2Xi: bjr yUsUZ
it-0-0 7-2-0 11-4-0 1 15-0-0 i 23-2-0 31-4-0 3%-2 45-0.0 A6-4-Q
1-4-0 5-10-0 4-2-0 3-B-0 8.2-0 B-2-0 7-10-0 5-10-0 1-4-0
Scale = 1:81.5
5.00 12 6x8 = 7x10 =
6x8 =
5 6 7
19 18 17 16 20 " 15 21 14 13' 12 22 114x6 =
ST1.5x8 STP = 2x4 11 ST1.5x8 STP = 5x6 = 5x8 = 3x6 = 2x4 11 ST1.5irB'STP =
4x6 = 3x6 = 3x8 = NAILED 2x4 II
2x4 11
1-4-0 46-4-0
1-0 7-2-0 11-4-0 15-0-0 23-2-0 31-4-0 39-2-0 45-0-0 - -0
-0- 5-10-0 - 4-2-0 3-e-0 8-2-0 B-2-0 7-10-0 5-M 0 4 0
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in , (loc)
I/defl
Ud
PLATES GRIP
TCLL 20.0
Plate Grip. DOL
1.25
TG 0.82
Vert(LL)
-0.26 12-13
>999
360
MT20 244/190'
TCDL 15.0
Lumber'DOL
1.25
6C - 0.92
Vert(CT)
-0.61 12-13
>660
240
BCLL 0.0
Rep Stress Incr
NO
WB - 0.98.
Horz(CT)
0.05 11
n/a
n/a
BCDL 10.0
Code FBC2017[TP12014
Matrix-SH
Wind(LL)
0.31 12-13
>999
240
Weight: 258lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 31 'Except' TOP CHORD Structural wood sheathing directly applied or 3-5-13 oc pudins.
5-6,6-7: 2x6 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
BOT CHORD 2x4 SP No.2 `Except*.. " WEBS 1 Row at midpt 5-16, 5-15, 7-15, 8-13
10-14: 2x4 SP M 31
WEBS 2x4 SP.No.3
REACTIONS. (lb/size) 19=190/0-8-0, 17=2463/0-8-0, 11=1575/0=8-0
Max Horz 19=-132(LC 9)
Max Uplift 19=-169(LC 27), 17=-773(LC 4), 11=-520(LC 9)
Max Grev 19=261(LC 19), 17=2463(LC 1), 11=1578(LC 20)
FORCES. (lb) -Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-166/383, 2-3= 74/448, 3-4=-141/872, 4-5=-352/271, 5-6=-15301742, 6-7=-1530/742,
7-8=-1972/746, 8-9=-2360/771;;9-10=-2090/597 '
BOT CHORD 1-19=-364/135, 18-19= 364/215, 17-18=-368/214, 16-17=-773/345, 16-20= 30/371,
15-20=-36/371; 15-21=-479/1747, 14-21=-479/1747, 13-14=-479/1747,.12-13=-600/2063,
12-22=-596/2061; 11-22=-596/2061, 10-11=-596/2061
WEBS 2-19=-284/294, 3-18=0/264, 3-17=-646/299, 4-17=-2032/668, 4-16=-525/1734,
5-16=-1272/495, 5-16=-585/1595, 6-15= 671/448, 7-15=-284/168, 7-13=-58/458,
8-13=-337/311, 9-11= 663/377
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASIDE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.20f; BCDL=5.Opsf; h=15ft; Cat. II; Exp C; Encl.,
GCpi=0.18; MWFRS (envelope); cantilever left,and right exposed; Lum. bel DOL=1.60 plate grip DO.L=1.60, ,
3) Provide adequate drainage, to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) 'This truss has been designed for a live load of 20.dpsf on the:bottom chord in all areas where a rectangle 3-6-0 Mall by 2-0=0 wide
will fit. between the bottom chord and any.other members, with BCDL=1,O.Opsf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 169 lb uplift at joint 19, 773 lb uplift at
joint 17 and 520 lb uplift at joint 11.
7) "NAILED" indicates 3-10d (0.148"x3") or 3-12d (0.1,48"x3.25") toe -nails per NDS guidlines.
8) In the LOAD CASE(S):section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead.+ Roof Live (balanced): Lumbee Increase=1.25, Plate Increase=1.25 .
Uniform Loads (plf)
Vert: 1-5= 70, 5-7=-70; 7-10=-70, 1-10=-20"
Concentrated Loads.(Ib)
Vert:. 22= 57(B)
Walter P. Finn PE N6.22839
MiTek USA, Inc. FL Cart 60.4
6904 Parke East Blvd. Tampa FL:33610.
Date:
October' 10,2019'
® WARNING - Verify design parameters and READ NOTES ONTHIS AND INCLUDED MITEK REFERANCE PAGE 11411=7473 rev- 10103/2015 BEFORE USE.
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the. building designer must verify the applicability of design parometers.and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to buckling of Individual truss and/or chord members only.. Additional temporary and permanent brocing
MiT®k'
prevent web
Is always required for stability and to prevent. collapse with possible personal Injury and property damage. For general guidance regarding the
6904 Parke East Blvd..
fabrication; storage; delivery, erection and bracing of trusses and truss systems, seeANSVTP11 Cuallty CrBedo, DSB-89 and BCSI Bulldtng Component
'
Tampa, FL 33610,
Safety Infonnatlonavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. .... .: ..... .:
. .
Job
Truss
Truss Type
Qty
Ply
..
T18335974
2M3091-TNT
62
Hip
1
1
Job Reference (optional)
eumers rirsioource, run riece, rL ovava-
ID:PftLgjXzGof3aThkEWERV6zC114-uTnrz?ol G9oK506KNOvJwU7FyVVOwFhXRubjr_yUsUZ
1-4 0, 7 2 0 11-4-0 13-0-0 11.7-9 26-4-15 i 33-4-0 i 39-2-0 4— --2
46-4-Q
• 1-4 0 5-10-0 T 4-2-0 1-8-0 6-7-9 ~ 6-9-5 6-11-1 5-10-0 5-10
5.00 F12
4x10
5x6 = 3x6 = 3x8 = 3x6 =
2x4 Sxfi
I I =
4 5 6 25 7 26 8 9
Scale = 1:84'.5
co
20HS II
N
2
co
I6
22 21 20 29 30 19 18 31 17 32, 16 15 14 134x6
4x6 = 2x4 II ST1.5x8 STP= 3x8 = 4x6 3x6 = 3x8 = 2x4 I I ST1.5x8 STP=
ST1.5x8 STP = 6x8 = 3x8.=
1-4-0 .. 46-4-0
7.2-0 11-4-0 19-7-9 26-4-15 33-4-0 39-2-0 45-0-0 45 -0
-0- 5-10-0 42-0 8-3-9 6-9-5 6-11-1 5-10-0 5-10-0 4 0
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc) I/defl Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.68
Vert(LL)
-0.23 14-15 >999 360
MT20
244/190
TCDL 15.0
Lumber DOL
1.25
BC 0.92
Vert(CT)
-0.53 14-15 >766 240
MT20HS
187/143
BCLL 0.0 '
Rep Stress Incr.
YES
WB 0.88
Horz(CT) .
0.05 13 n/a n/a
BCDL 10.0
-.Cade FBC2017[TP12014
Matrix-SH
Wind(LL)
0.32 14-15 >999 240
Weight: 245lb
FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 31 'Except` '.
TOP CHORD
' Structural wood sheathing directly applied or 3-3-3 ocpurlins.
5-7,7-9: 2x4 SP No.2
BOT CHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
BOT CHORD 2x4 SP No.2 *Except*
WEBS
1 Row at midpt 5-20, 8-15, 5-18
12-16: 2x4 SP M 31
WEBS 2x4SP.No.3
REACTIONS. (lb/size) 22=115/0-8-0;_20=2556/0-8-0, 13=1500/0-8-0 .
Max Horz 22=116(LC 16)
Max Uplift 22=-150(LC 12), 20=-863(LC 8), 13=-526(LC 9)
Max Grav 22=175(LC 23), 20=2556(LC 1), 13=1511(LC 24)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-376/500, 2-23=-191/525, 23-24=-183/552, 3-24=-176/583, 3-4=-459/1022,
4=5=-383/1029, 5-6=-1175/979,; 6-25=-1870/1406, 7-25=-1870/1406, 7-26=-1870/1406,
8-26=-1870/1406, 8-9==1835/1415, 9-10=-2029/1420, 10-27=-2100/1487,
27-28=-2109/1481, 11-28=-2235/1470, 11-12=-1940/1182
BOT CHORD 1-22=-484/316, 21-22=484/337, 20-21=-484/337, 20-29=-349/385, 29-30=-349/385,
19-30=-349/385, 18-19=-349/385, 18-31=-534/1175: 17-31=-534/1175, 17-32=-961/1870,
16-32=-961/1870, 15-16==961/1870, 14-15=-1204/1938, 13-14=-1204/1938,
12-13=-1204/1938 .
WEBS 2-22=-233/447, 5-20=-2020/1300, 9-15— 109/368, 10-15=-193/268, 11-13=-721/744,
3-20=-663/575, 5-18=-1204/1924, 8-17=-477/460, 6-18=-1085/857, 6-17=-603/922
NOTES-
1) Unbalanced. roof live loads have been considered for this design..
2) Wind: ASCE 7-10; Vult=170mph (3-second 'gust) Vasd=132mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft;'Cat. 11; Exp C; Encl.,
GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) 0-0-0 to 6-0-0, Interior(1) 6-0-0'to 13-0-0, Exterior(2) 13-0-0 to 21-5-13, Interior(1)
21.5-13 to 33-4-0, Exterior(2) 334-0 to 41-9-13, Interior(1) 41-9-13 to 46-4-0 zone; cantilever left and right exposed ;C-C for members
and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water.ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0.0 wide
will fit between the bottom chord and any other members,: with: BCDL = I O.Opsf.:
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 150 lb uplift at joint 22, 863 lb uplift at
joint 20 and 526 lb uplift at joint 13.
LOAD CASE(S) Standard
Walter P. Finn PE N6.22839
MiTek USA,16c. FL Cert 66U
6904 Parke East Blvd. Tampa FL.33810
Date:
October 10,2019
0 WARNING - Verify design parameters and READ NOTES ONTH/S AND INCLUDED MITEK REFERANCE PAGE'MIJ-7473 rev. 10103,2015 BEFORE USE.
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a.tiuss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only.. Additional temporary and permanent bracing.
MiTek`
Is always.required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the.
fabrication, storage; delivery, erection and bracing of trusses and truss systems, seeANSVIPII Quality CrBoda, DSB•89 and BCSI BuBding Component:
.
6904 Parke East Blvd,
Safety Informatlonavailable from Truss Plate Institute; 218 N. Lee Street Suite 312, Alexandria, VA 22314.
Tampa, FL 33610. .
Job
Truss
Truss Type
Qty
Ply
T18335975
20,003091-TNT
B3
Hip
1
1
Job Reference (optional)
m-uers ri—auu—, ID:PftLgjXzGof3aThkEwERV6zC114-_.1Tw-
QYS_ fPMv. s_ _iMgKDLdklk7f5g_g- Y_ KG-
ORyUsUYA
i1-4-0 6-1-5 19-3-9 26-8-15 34-4-0 40-2-11 45-0.0 A6-4-q
1-4-0 4.9-5 13-2-5 7-5-5 5-10-11 1-4-0
5x6 =
3x6 = 5x6 = 5x6 =
20 19 18 17 16 15 14 13 12
4x6 = 2x4 1 2x4 11
ST1.5x8 STP — 3x8 —_ 4x6 = 3x6 = 3x8 — 3x8 =
ST1.5x8 STP = 6x8 = _
2x4 11
Scale = 1:80.5
c?
0
m
IT
a
11' _
ST1.5x8 STP =
4x10 MT20HS I I
1-4-0 .. .. 46-4-0
16-1-s 11-0-0 2-0 19-3-9 26-8-ts 34-0-0 40-2-11 45-d-0 -0
-0- 4-9-5 4-10-11 -0- 7-3-9 7-5-5 7-7-1 5-10-11 4-9-5
Plate Offsets (X Y)--
[1.0-0-0 0-1-7] [4.0-3-0 0-2-4] [6.0-3-0 0-3-4]
[7.0-3-0 0-2-4]
[9'0-0-12 0-1-12] [11:0-1-15
1-0-41
[11:0-0-0 0-1-121
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc)
Well
Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.76
Vert(LL)
-0.22 12-13
>999
360_
MT20
244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.88
Vert(CT)
-0.49 12-13
>825
240
MT20HS
187/143
BCLL 0.0 '
Rep Stress Incr YES
WB 0.87
Horz(CT)
0.04 11
n/a
n/a
BCDL 10.0
Code FBC2017ITPI2014
Matrix-SH
Wind(LL)
0.29 12-13
>999
240
Weight: 236lb
FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 31 •'Except TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins.
6-7,4-6: 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 5-10-7 oc bracing.
BOT CHORD 2x4 SP No.2 *Except* WEBS 1 Row at midpt 4-18, 6-13, 4-16, 5.15
10-14: 2x4 SP M 31
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 18=2693/0-8-0, 20=8/0-8-0, 11=1469/0-8-0
Max Harz 20=107(LC 16)
Max Uplift 18=-935(LC 8), 20=-175(LC'24), 1.1=-524(LC 9)
Max Grav 18=2693(LC 1), 20=67(LC 23), 11=1491(LC 24)
FORCES.. (lb) - Max. Comp./Max. Ten. - All.forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-392/554, 2-21==260/593, 3-21=-248/642, 3-4=-679/1290, 4-5=-1127/877,
5=22=-1975/1399, 22-23=-1975/1399, 6-23=-1975/1399, 6-7=1873/1390, 7-8=-2068/1390,
8-24=-2078/1410, 9-24=-2137/1396, 9-1 0=-1 868/1145
BOT CHORD 1-20=-540/364, 19-20=-540/384, 18-19=-540/3B4, 17-18=-836/726, 16-17=-836/726,
15-16= 458/1127,.14-15=-993/1988, 13-14=-993/1988, 12-13— 1144/1852,. . '
11-12=-1144/1852, 10-11=-1144/1852
WEBS 7-13=-76/367, 3-18=-757/691, 4=18=-2228/1479, 6-13=-264/140, 4-16=-1437/2283,
6-15=-486/491, 5-16=-1168/915; 5-15= 711/1076,2=20_ 126/312, 9-11=-666/645
NOTES-
1) Unbalanced roof.live loads have been considered for this design.
2) Wind: ASIDE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; Cat. ll; Exp C; Encl.,
GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) 0-0-0 to 6-1-5, Intedor(1) 6-1-5 to 12-0-0, Extedor(2) 12-0-0 to 20-5-13, Interior(1)
20-5-13 to 34-4-0, Exterior(2) 34-4-0 to 42-9-13,' Interior(1) 42-9-13 to 46-4-0 zone; cantilever left and right exposed ;C-C for members '
and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This,truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for live load of:20.Opsf on the bottom chord in all areas where -a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members:
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 935 lb uplift at joint 18, 175 lb uplift at
joint 20 and 524 lb uplift at joint 1:1.
LOAD CASE(S) Standard
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cent 6634:
6904 Parke East Blvd. Tampa FL 13410
Date:
October 10,2019
Q WARNING -Verify design parameters and READ NOTES ON. THIS AND INCLUDED MfrEK REFERANCE PAGE'M11-7473 rev. laI03/2015 BEFORE USE.
Design valid for use only with MITek® connectors. This deslgn Is based only upon parameters shown, and Is for an individual building component, not
�
a.truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chord members only.. Additional temporary and permanent bracing
MiTek`
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage; delivery, erection and bracing of trusses and truss systems, seeANSVTP11 Qua1By Criteria, DSB-89 and BCSI Building Component.
6904 Parke East Blvd.,
Safety Infarmatlorlavallable from Truss Plate Institute; 218 N. Lee Street, Suite 312, Alexandria, VA 22314. ..... .
Tampa, FL 33610. ,
Job
Truss
Truss Type
Qty
piy
T18335976
20$03091-TNT
B4
Hip
1
1
Job Reference (optional)
burners mrstbource, t-ort niece, r-L 44e40
ID: PftLgjXzGof3aThkEwERV6zC114-gsubOgplom22LKGjVrxn7vCYFJBMOABquC4gwty9sUX
11-4-0 5-8-4 , 10-0-0 IT-4 6-2-9
17-6-9 23-9-2 , 29-11-11 , 36-4-0 40-7-12 45-0-0 A6-4-Q
• r-4-0 4-4-4 4-3-12 1.4-0 6-2-9 6-2-9 6-2-9 6-4-5 4-3-12 4-4-4 1-4-0
0
5x6 =
5.00 12
4 5
4x6 =I 3x8 = 5x8
6 25 7 8 26 9. 10
2x4 II
2x4 i
24
- 3
11 27 ,
2x4 I I
WO MT
2
12 1
1
Scale=1:82.3
!OHS II
3
ia�J ... " 4x6 =
23 22 21 20 19 18 17 16 15 14
4x6 = ST1.5x8 STP = 3x8 -- 3x8 — ST1.5x8 STP =
ST1.5x8 STP = - 6x8
2x4 11
1-4-0
- 46-4-0
5-8-0 11-4-0 17-0-9
23-9-2
29-11-11
36-4-0
45-0-0
-0- 4-4-0 5-8-0 6-2-9
6.2-9
6-2.9
6-0-5
8-8-0 0 4 0
0-4-0
1-0-0
Plate Offsets (X Y)-- [1.0-0-0 0=1-71 [4.0-3-0 0-2-4] [10'075-12 0-2-81 [12.0-1-13 1-0-0] [12.0-0-12 0-1-121 [13:0-0-0 0-0-15]
[14:0-0-0 0-1-121-
LOADING (pso
SPACING- 2-0-0
CSI.
DEFL.
in (loc) I/deft
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.88
Vert(LL)
-0.24 15-17 >999
360
MT20 244/190
TCDL 15.0
Lumber DOL' 1.25
BC 0.95
Vert(CT)'
-0.51 15-17 >793
240
MT20HS 187/143
BCLL 0.0
Rep Stress Jncr YES
W B 0.82
Horz(CT)
0.07 14 n/a
n/a
BCDL 10.0
Code FBC2017/TM014
Matrix-SH
Wind(LL)
0.30 15-17 >999
240
Weight: 242 lb FT = 20 %
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 31 `Except'
TOP CHORD Structural wood sheathing directly applied or 2-2-0 ob purlins.
4-8,8-10: 2x4 SP No.2
BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing.
BOT CHORD 2x4 SP No.2 *Except*
WEBS
1 Row at micipt
6-21, 7-1.9
13-16: 2x4 SP No.1
WEBS 2x4 SP N6.3
WEDGE
Right: 2x4 SP No'.3
REACTIONS. (ib/size) 23=-131/0-8-0, 21=2875/0-8-0, 14=1427/0-8-0
Max Harz 23=90(LC 16)
Max Uplift 23= 330(LC 24), 21= 1077(LC 8), 14=-521(LC 9)
Max Grav 23=108(LC 9), 21=2875(LC 1), 14=1443(LC 24),
FORCES. (Ib) -Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2= 528l747, 2-3=-423/865, 3-24=-224/751, 4-24=-223/797, 4-5=-831/1551,
5-6=-831/1551; 6.25=-595/459, 7-25=-595/459, 7-8=-1816/1191, 8-26=-1816/1191,
9-26=-1816/1191,:9-10=-2268/1537, 10-27=-2003/1299, 11-27=-2015/1286,
11-12= 2078/1396, 12-13=-1657/950
BOT CHORD 1-23=-735/508, 22-23=-735/531, 21-22— 1278/1012, 20-21=-161/595, 19-20=-161/595,
18-19=-835/1816, 17-18=-1192/226B, 16-17=-924/1849, 15-16=-924/1849,
14-15=-1083/1761, 13-14=-1083/1761
WEBS 3-22=-469/545, 4-22= 767/917, 4-21=-939/699, 5-21=-441/435, 12-14=-1005/961,
10-17=-336%583; 6-21=-2503/1549, 6-19=-487/1605, 9-.18=-581/437, 7-19=-1523/950, .
7-18=-182/496
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; Cat. II; Exp C; Encl.,:
GCpi=0.18; MWFRS (envelope) and,C-CExterior(2) 0-0-0 to 6-'0-0, Interior(l) 6-0-0 to 10-0-0, Exterior(2) 10-0-0 to 18-6-13, Interior(1)
18-5-13 to 36-4-0; Exterior(2) 36-4-0 to 45-070, Interior(1) 45-0-0 to 46-4-0 zone; cantilever left and right exposed ;C-C for members
and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip:DOL=1.60
3) Provide adequate drainage to prevent water ponding,, .
4) All plates are MT20 plates unless otherwise indicated.
5) All. plates are 3x6 MT20 unless. otherwise indicated.
6) This truss has been designed for a 10.0 Psf bottom chord live load'nonconcurrent with any other. live loads:
7) ' This truss has been designed for a live load of.20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom.chord and any other members. .
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding'330 lb uplift at joint23, 1077 Ib uplift at
joint 21 and 521 lb uplift at joint 14.
LOAD CASE(S) Standard
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cart 6634
6964 Parke East Blvd. Tampa FL 33011
Date: -
October 10,2019
' A WARNING- Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCEPAGE MIF7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MiTek0 connectors. This design Is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the. building designer must verity the applicability of design parameters.and properly Incorporate this design Into the overall
building design. Bracing Indicatedisto buckling individual truss and/or chord members only.. Additional temporary and permanent bracing.
MiTeW
prevent of .web
Is always required for stability and to prevent.collapse with possible personal Injury and property damage. For general guidance regarding the : - ... -
. '
6904 Parke East 131vd..
fabrication; storage; delivery, erection and bracing of trusses and truss systems, seeANSUTPII Quality Cdtorla, DSB-89 and BCSI Bu6ding Component,
Tampa, FL 33610..
Safety Infoanationovailoble from Truss Plate Institute; 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
.
Job
Truss
Truss Type
Qty
Ply
T18335977
201s03091-TNT
135
Hip Girder _
1
1
Job Reference (optional)
eun0ers rusraource, ron riece, rL 04e40 ... .. ...,.. ...- __.. _ . _.._.._ --'- ' - -
I D:PftLgjXzGof3aThkEwERV6zC114-12SzbogwZ4AvyU rv3YTOX71oWje27agz7spNSJyUs0 W
it-4-0 4-8-0 8-0-0 11-4-1 17-3-B 23-2.2 , 29-0-8 35-0-0 38-4-0 1 41-8-0 45.0-0 46-4-q
• 1-4-0 3-4-0 3-4-0 3-4-0 5-11-8 5-10-8 5-10-8 5-11-8 3-4-0 3-4-0 3-4-0 1-4-0
NAILED NAILED NAILED NAILED NAILED
8x14 MT20HS= NAILED NAILED I NAILED NAILED NAILED NAILED 8z14 MT20HS=
5.00 F12 Special 8x10 = NAILED 7x10 NAILED 2x4 II NAILED 7x10 = NAILED 8x10 = Special
3 21 4 22 23 24 5 25 26 27 6 28 29 307 31 32. 338 34 9
4x6 7�- U m qP a a U
4x6 2
0
k_J
8x12 = 20 35 1936 37 18 1.7 38 39 40 16 41 .42
5x8 = 2x4 II ST1:5x8 STP= 6xl2 MT20HS= NAILED 5x12 = NAILED
ST1.5x8 STP= Special 7x10 = NAILED 5x12 = NAILED NAILED
NAILED NAILED NAILED.
NAILED NAILED
4315 14 44 4513 46 12
5x12 = NAILED 7x10 = 2x4 II
6xl2MT20HS= NAILED Special
NAILED NAILED
NAILED
Scale = 1:80.0
46 � .
10 46
0
11 co
M
Ire
0
ST1.5x8 STP =
8x12 =
5x8 =
1-4-0 - 46-4-0
6-0-0 11-4-0 17-3-8 23-2-0 29-0-8 35-0-0 38-4-0 45-0-0 4 -0
6-8-0 3-4-0 5-11-8 5-10-6 5-10-6 5-11-6 3-4-0 6-6-0 0 4 0
0-4-0 1-0.0
Plate Offsets (X,Y)-- [1:0-1-2,Edge], [3:0-11-12;0-4-8], [5:0-5-0,0-4-8], [7:0-5-0;0-4-8], [9:0-11-12,0-4-8], [11:0-1-2,Edge], [13:0-5-0,0-4-12], [15:0-4-12,0-2-0], [16:0-6-0,0-2-0],
r47•n_A-19 n-9-nl r10-n_F_n n_d_191
LOADING (psf)
SPACING-
2-0-0
C§l.
DEFL.
in (loc)
I/dell
Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.53
Vert(LL)
0.37 15-16
>999
240
MT20
244/190
TCDL 15.0
Lumber DOL
1.25
BC 0.41
Vert(CT)
-0.53 15-16
>778
240
MT20HS
187/143
BCLL 0.6 '
Rep Stress Incr
NO
WB 6.98
Horz(CT)
0.05 11
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix-SH
Weight: 323 lb
FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x6 SP M 26 *Except* TOP CHORD Structural wood sheathing directly applied or 3-1-3 oc purlins.
5-7: 2x6 SP, No.2 BOT CHORD Rigid ceiling directly applied or 4-4-8 oc bracing.
BOT CHORD 24SP.M 26 WEBS 1 Row at rilidpt 3-19; 4-17, 7-16, 5-16
WEBS 2x4 SP No.3 *Except*
4-19,8-13: 2x6 SP No.2, 8-15,4-17,7-16,5-16: 2x4 SP No.1
SLIDER Left 2x6 SP No.2 3-9-3, Right 2x6 SP No.2 3-9-3
REACTIONS. (lb/size) 1=-910/0-8-0, 11=2497/0-8-0, 19=6574/0-8-0
Max Harz 1= 69(LC 32) .
Max Uplift 1_ 1100(LC 20), 11=-1158(LC 9), 19=-3192(LC 5)
Max Grav 1=567(LC6), 11=2497(LC 1), 19=6574(LC 1)
FORCES. (lb) -.Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-1465/3154, 2-3- 1450/3194, 3-21=-2264/4840, 4-21=-2265/4841, 4-22=-779/432,
22-23=-779/432, 23-24=-779/432, 5-24=-779/432, 5-25=-4621/2301; 25-26=-4621/2301,
26-27= 4621/2301, 6-27=-4621/2301, 6-28=-4621/2301, 28-29=4621/2301,
29-30=-4621/2301, 7-30=74621/2301, 7-31=-6273/3103, 31-32=-6273/3103,
32-33=-6273/3103, 8-33=-6273/3103, 8-34=-5958/2974, 9-34=-5959/2974,
9-10=-5299/2620, 10-11=-5425/2607
BOT CHORD 1-20=-2878/1405, 20-35=-2863/1403, 19-35=-2863/1403, 19-36=-4840/2405,
36-37=-4840/2405, 18-37= 4840/2405, 17-18=-4840/2405, 17-38=-366/906,
38-39=-366/906, 39-40= 366/906, 16-40=-366/906, 16-41=-2971/6268, 41-42=-2971/6268,
42-43- 2971/6268, 15-43=-2971/6268, 14-15=-2834/5959, 14-44=-2834/5959,
4445=-2834/5959, 13-45=-2834/5959, 1346=-2317/4907, 12-46=-2317/4907,
11-12- 2313/4887
WEBS 3-20=-81/489, 3-19=-2963/1431, 4-19=-4067/2170, 8-13_ 898/618, 9-13=-738/1593,
9-12=-118/552, 8-15=-148/413, 4-17=-3102/6447, 7-15=0/359, 5-17=-2984/1705,
7-16=-1917/942, 5-16=-2087/4325, 6-16=-899/721 :.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; Cat. II; Exp C; Encl.,
GCpi=0.18; MWFRS (envelope);:cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water pending.
4) All plates are MT20 plates unless otherwise indicated.
5) This=truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0:tall by 2-0-0 wide
will fit between the bottom chord and any other members.
' 7) Provide mechanical connection by others) of truss to bearing plate capable of withstanding 1100 Ib.uplift at joint 1, 1158 lb uplift at .
joint 11.and 3192 lb uplift at joint 19:
Walter P. Finn PE N6.22839
MiTek USA, Inc. FL Cert 6634'
6904 Parke East Blvd. Tampa FL 33610
Date:
October 10,2019
WARNING- Verity desfgn parameters and READ NOTES ON.THIS AND INCLUDED MITEK REFERANCE PAGE 111I1-7473 rev. 1010312015 BEFORE USE.
.
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
p
a truss system. Before use, the building designer must verify the applicability of design parameters.and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only.. Additional temporary and permanent bracing
MiTek' '
Is always required for stability and to prevent. collapse with possible personal Injury and property damage. For general guidance regarding the: . . '
fabrication; storage; delivery, erection and bracing of trusses and truss systems, seeANSU1P11 Guallty Cdteda, DSB-89 and SCSI Bulding Component.
. .
6904 Parke East Blvd.,
Safety Infomlatlonavallable from Truss Plate Insfltute; 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL'33610. .
Job
Truss
Truss Type
Qty
Ply
'
T18335977
20903091-TNT
B5
Hip Girder
1
1
Job Reference (optional)
ouimers mrsraource, run riece, rLuysro . n.,, o., ,.,.�, �., ., .... ,•.._. ..._ __.._ ._.. _..---'- ' - -
ID: PftLgiXzGof3aThkEwERV6zC1.14-12SzbogwZ4AvyUrv3YTOX7loWie27agz7spNSJyUsU W
NOTES-
' 8) This truss has large uplift reaction(s) from gravity load case(s). Proper connection is required to secure truss against upward movement at the bearings. Building designer
must provide for uplift reactions indicated.
9) "NAILED" indicates 3-1 Od (0.148"x3") or 3-12d (0. 1 48"x3.25") toe -nails per NDS guidlines.
10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 266 lb down and 344 lb up at 8.0-0, and 266 lb down and 344 lb up at
38-4-0 on.top chord, and 343 lb down and 187 lb up at 8-0-0, and 343 lb down and 187 lb up at .38-3-4 on bottom chord. The design/selection of such connection
device(s) is the responsibility of others.
11) In the LOAD CASE(S) section, loads applied -to .the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=41.25
Uniform Loads (plf)
Vert: 1-3= 70, 3-9=-70, 9-i t=-70, 1-11=-20
Concentrated Loads (lb)
Vert:3=-219(F) 9= 219(F)18=-57(F) 20=-343(F) 12=-343(F) 16=-57(F) 6=-138(F) 14=-57(F) 21— 138(F) 22= 138(F) 23=-138(F) 24— 138(F) 25=-138(F) 26=-138(F)
27=-138(F) 28=-138(F) 29= 138(F) 30=-138(F) 31=-138(F) 32=-138(F) 33=-138(F) 34=-138(F) 35=-57(F) 36=-57(F) 37=-57(F) 3B= 57(F) 39= 57(F)40=-57(F)
41=-57(F) 42=-57(F) 43=-57(F) 4.4=-57(F) 45=-57(F) 46— 57(F)
WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCEPAGE MII-7473 rev. 10/03/2015 BEFORE USE.
, -
-Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
��
a.fruss system. Before Use, The. building designer must verify the applicabllity of design parameters.and properly Incorporate this design Into the overall
building deslgn. Bracing Indicated Is to prevent buckling of Individual truss.web and/or chord members only.. Additional temporary and permanent bracing
MiTek'
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the:
.
fabrication; storage; delivery, erection and bracing of trusses and truss systems, seeANSMII Cua1By Criteria, DSB49 and Best Buldtng Component:
6904 Parke East Blvd. '
Safety Informationavoilable from Truss Plate Institute; 218 N. Lee Street, Suite 312, Alexandria, VA 22314. ...
Tampa, FL 33610..
Job
Truss
Truss Type
City
Ply
T18335978
20103091-TNT
c1
Roof Special
1
1
Job Reference (optional)
omioers nrsraourca, ror[ rises, r� uYavo null. o.a+v o r'.. ' ' '.., E , o ....� �, �.. k o� ,.,, 27' �....... v% �..... ..-y., .
ID:PftLgjXzGof3aThkEwERV6zC114-mFOMpMrYKOImad05cG_F4KHu27u9sOG6MWZx_myUsUV
6-5-4 i 11-2-8 15-11-12 1 20-9-0 23-2-0 29.10-0 35-5-0 39-7-15 1 46-4-0 i
49-4 49-4 4-9-4 2-5-0 6-8-04-2-15 6-8-1
Scale = 1:79.1
5x6
4x6 a
7
3x6 75--
4x6
.. . 26
27 9
6,
3x8 Z
3xB MT20HS i 4x6
10 3x6
5.00 12 5 19
11
4x6 - 4 6x8 =
18
2x4
_ 3 20 4x12 z:z
12
4
4x6 %
5x6
5x8 %25 22 21
17
13 lb
5x6 �
2 4x10 MT20HS 4.00 12
7xl0 "
14
w 1 23 4x6 %
m
I�
o 6x8 ;
a.
4x6 = 24
16
15
ST1.5x8 STP =
ST1.5x8 STP = _
3x4 II
ST1.5x8 STP =
5x12 II
5x6
6x12 MT20HS =
1-9-0 -
46-4-0
1.0-0 6-5-4 11-2-e 15-11-12 20-7.4 20i8-0
29-10-0
35-5-0
_,
45-0-0
45 -0
-IrO-d� 4-9-4 4-9-4 4-9-44-7-e 0-i 12
9-1-0
5-7-0
9-7-0
W4�0 '
0-6-0
Plate Offsets (X Y)-- [1:0-0-0 0-1-71 rl4:1-6-11 0-2-8] rl4:0-3-8 Edge] [15:0-6-0 Edgel [19:0-4-0 0-3-12]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in . floc) I/defl
Ud
PLATES
GRIP
TCLL 20_.0
Plate Grip DOL 1.25
TC 0.86
Vert(LL)
-0.33 20-22 '>999
360
MT20
2441190
TCDL 15.0
Lumber DOL -1.25
BC 0.80
Vert(CT)
-0.76 20-22 >536
240
MT20HS
187/143
BCLL 0.0
Rep Stress Incr -YES
WB 0.97
Horz(CT)
_ 0.47 15 n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix-SH
Wind(LL)
0.4420-22 : >912
240
Weight: 263lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2 'Except'
TOP_ CHORD
Structural wood.sheathing directly
applied or 2-3-13
oc purlins.
10-14: 2x4 SP M 31
BOT CHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
BOT CHORD 2x4 SP No.2 `Except
WEBS
1 Row at midpt
15-17
19-21,17-19,21-24:2x6 SP No.2, 9-16: 2x4 SP No.3
WEBS 2x4 SP N6.3 `Except
2242600N 222324SPN 2
x o. , x 0.
SLIDER Right 2x8 SP 240OF 2.0.E 3-4-15
REACTIONS. (lb/size) 24=1229/0-8-0, 15=3849/0-6-0, 14=-938/0-8-0
Max Harz 24=-262(LC 13)
Max Uplift 24=-471(LC 12), 15=-1162(LC 12), 14=-976(LC 23)
Max Grav 24=1229(LC.1), 15=3849(LC 1), 14=394(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-277/140, 2-25=-3483/1935, 3-25= 3348/1936, 3-4=-4161/2205, 4-5=-4100/2214,
5-6=-3399/1778, 6-26=-1916/884, 7-26= 1847/898, 7-8=-651/470, 8-27=-624/422,
9-27=-728/403, 9.10=-619/1749, 10-11=-635/1704, 11-12=-1466/3368, 12-.13=-1189Y2837,
13-14=-1202/2757
BOT CHORD 1-24— 139/285, 22-23=-1717/3336, 21-22=-1873/3987, 20-21=-1859/4004,
19-20=-1337/3259, 18-19=-326/1791, 17-18=-1660/1044, 9-17=-1790/974,
14-15=-2462/1171
WEBS 2-24=-1044/835, 2-23= 1746/3207, 3-23=-521/404, 7-19= 593/1743, 15-17=-3646/1920,
11-17=-721/1593, 11-15=-1232/692, 12-15=-744/637, 3-22=-240/644, 5-20=-749/592,
6-20=-140/393, 6-19= 1401/961, 8-18= 84/259, 9-18=-764/2118, 7-18� 1876/892
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; Cat. II; Exp C;. Encl.,
GCpi=0.18; MWFRS (envelope) and: C-C: Extedor(2) 0-0-0 to 6-0-0;.Intedor(1) 6-0-0 to 23-2-0, Exterior(2) 23-2-0 to 29-2-0, Interior(1).
29-2-0 to 46-0-0 zone; cantilever left and right exposed ;C-C for members and forces & MW FRS for reactions shown; Lumber
DOL=1.60 plategrip DOL=1.60
3) All plates are MT20 plates unless otherwise indicated. _
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) *.This truss has been designed fora live load of 20.Opsf on.the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any othermembers.
6) Provide mechanical connection (by others) of tniss to bearing plate capable of withstanding 471 Ili uplift at joint 24, 1162 lb uplift at
joint 15 and 976 lb uplift at joint 14:
LOAD CASE(S) Standard
Walter P. Finn PE No.22839
Mi rek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL:13610.
Date:
October 10,2019
Q WARNING- Verity design parameters and READ NOTES.ONTHIS AND INCLUDED WEK REFERANCE PAGE MIP7473 rev. f0/03/2015 BEFORE USE.
Design valid for use only with MITe& connectors, This design Is based only upon parameters shown, and Is for an individual building component, not
a.truss system. Before use, the. building designer must verify the, applicability of design porameters.and properly Incorporate this design Into the overall
building design. Bracing Indicated is to buckling of Individual truss web and/or chord members only.. Additional temporary and permanent bracing
r
prevent
Is always required for stability and to prevent. collapse with possible personal Injury and property damage. For general guidance regarding the:,,
6904 Parke East Blvd..
fabrication; storage, delivery, erection and bracing of trusses and truss systems, seeANSViPII Quality Criteria, DSB-69 and SCSI Bu6dtnp Component:
Tampa, FL 33610..
Safety Infonnatbnovallable from Truss Plate Institute; 218 N. Lee Street, Suite 312, Alexandria, VA 22314. ..... . . ..... . .:
.
Job
Truss
Truss Type
Qty
y
T18335979
2NO3091-TNT
C2
Hip
1
1
.
Job Reference (optional)
timaersrimtacurce,ranriece,rL —D .,—,, I., „... -, ,- ...--_.._._.._..---.-.--.
ID:PftLgjXzGof3aThkEwERV6zC114-mFOMpMrYKOImadQ5cG_F4KHsz7vlslh6MWZx_myUsUV
i 1-8-0 11-12 16d8 5-00--08 24400 259-.610.-0 3-7-115 45--84--10
0-12 4-2.4 24 04-9-4 49-4 -157-0 5 ,
5x6 = 5x6 =
7 8
3x6
6
3x8 MT20HS _ 4x6 5:� 26
5.00 F12 5 19
4x6 � 4 6x8 II 18
3 20 4x12
5x8 _ 21 4x6
25 22
1 .2 4x10 MT20HS % 4.00F2
co 23 4x6
0 6x8
4x6 = 24
ST1.5x8 STP =
5x6
7x10
4x6
9. .
16
3x4 Il
3x8
27 10 3x6
11
15
ST1.5x8 STP =
6x8 =
Scale =1:82.1
2x4
28
12 5x6 C v
13 m
14
171
0
ST1.5x8 STP =
4xl0 MT20HS I I
1-6-0 -
1-0- 6-5-4 11-2-9 15-11-12 20-7-0 20 -0 24-4-0 29-10-0 35-5-0 45-4.0
-0 4-9-4 4-9-4 4-9-4 4-7-e 0- 12 3-7-0 5-6-0 5-7-0 9-11-0
n.e.n
M
m
d,
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/deft
Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 1.00
Vert(LL)
-0.34 20-22>999
360
MT20 '
244/190
TCDL '15.0
Lumber DOL
1.25
BC 0.77
Vert(CT)
-0.76 20-22
>535
240
MT20HS
187/143
BCLL 0.0 '
Rep Stress Incr
:YES
WB 0.94
Horz(CT)
0.47 15
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix-SH
Wind(LL)
0.4420-22
>925
240
Weight: 279lb
FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP N0.2 'Except' TOP CHORD Structural wood sheathing directly applied.
10-14: 2x4 SP M 31 BOT CHORD Rigid ceiling directly applied or 3-1-15 oc bracing.
BOT CHORD 2x6 SP No.2 'Except' WEBS 1 Row at micipt 15-17
1-24,14-16: 2x4 SP No.2, 9-16: 2x4 SP No.3
WEBS 2x4 SP.N6.3 "Except'
2-24: 2x6 SP No.2, 2-23: 2x4 SP No.2
SLIDER Right 2x8 SP 240OF 2.0E 3-1-5
REACTIONS. (lb/size) 24=1241/0-8-0, 14=-1021/0-8-0, 15=3860/0-6-0
Max Harz 24=-192(LC 13)
Max Uplift 24=-473(LC 12), 14=-1068(LC 23), 15=-1131(LC 12)
MaxGrav 24=1241(LC 1), 14=390(LC 12), 15=3860(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-279/139, 2-25=-3533/1993, 3-25=-3398/1995, 3-4=-4231/2481, 4=5=-4168/2489,
1 5-26=-3515/2131, 6-26=-3399/2140, 6-7=-977/997, 7-8=-472/468, 8-9=-602/423,
9-27=-680/1684,.10-27=-688/1646, 10-11=-696/1639, 11-28=-1521/3272,
12-28=-1523/3165, 12-13=-l177/2670, 13-14=-1194/2610
BOT CHORD 1-24— 137/287, 22-23=-1831/3385, 21-22=-2174/4052, 20-21=-2160/4069,
19-20— 1718/3381, 18-19=i 75/1113, 17-18=-1602/1134; 9-17=-1769/1014,
14-15= 2269/1158
WEBS 2-24= 1053/843, 2-23=-1850/3256, 3-23=-532/419, 12-15=-873/698, 3-22=-334/661,
7-19=-716/1758; 7-18— 1336/697, 9-18=-843/1930,.15-17=-3545/2060, 11-17=-807/1595,
11-15=-1233/786, 5-20=-703/544, 6-20— 119/375, 6c19=-1478/1277
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph:(3-second gust) Vasd=132mph; TCDL=4.2psf; 13CDL=5.0psf; h=15ft; Cat. 11; Exp C;. Encl.,
GCpi=0.18; MWFRS (envelope) and C-C:Exterior(2) 0-0-0 to 6-0-0;.Interior(1) 6-0-0 to 22-0-0, Ext6dor(2) 22-0-0 to 32-9-13, Interior(1)
32-9-13 to 45-4-0 zone; cantilever left. and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber :
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed fora 10.0 psf bottom chord: live load nonconcurrent with any other live loads.
6) . This truss Has been designed for alive load of 20.Opsf on the bottom.chord in all areas where a rectangle 3-6-0 tall by 2-0-0.wide
will fit between the bottom chord and any othermembers.
7) Provide mechanical connection.(by others) of trliss,to bearing plate capable Of withstanding 473 lb uplift atjoint 24,,1068 Ib uplift at' '
joint 14 and 1131 lb ii Ilft at ornt 15.
joint P.. 1 .
8) This truss has large uplift reaction(s) from gravity load case(s): Proper connection is required to secure truss against upward
movement at the bearings. Building designer must provide for uplift reactions. indicated.
Walter P. Finn PENo.22839
MiTek USA, Inc. FL Cert 6634,
.6904 Parke East Blvd. Tampa FL,33610;
Date:
October 10,2019
Q WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGEMX7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MITek® connectors. This design Is based only upon parameters' shown, and Is for an Individual building component not
..
�•
a.truss system. Before use, thei building designer must verity the applicability of design porometers.and properly Incorporate this design Into the overall
building design. Bracing indicated isto buckling Individual truss:web and/or chord members only.. Additional temporary and permanent bracing.
p/t
MiTek"
prevent of
Is always.required for stability and to prevent, collapse with possible personal Injury and property damage. For general guidance regarding the: ' ' .. .
.
6904 Parke East Blvd.,
fabrication, storage; delivery, erection and bracing of trusses and truss systems, seeANSM11 Quality Cdtoda, DSB-69 and SCSI BuOding Component:
Tampa, FL 33610..
Safety Infonnatbnovallable from Truss Plate Institute; 218 N. Lee Street Suite 312, Alexandria, VA 22314.
o
russ
Truss Type
City
y
T18335980
20403091-TNT
C3
Hip
1
1
Job Reference (optional)
ouuuers ri—o uu, run rrccn, r� aYaYo ..., ..., .. _...., ....... _._ ._ _ __. _. __ . _ .-... _.- ...___-..__...._
ID: PftL!XzGof3aThkEwERV6zC114-ERak0isA5hQdCn71AzV UdYg1 xW F_bU3GaAl UXCyUsU U
1-8-0 fi-5-4 11-2-8 15-11-12 161-8 20-0-0 26-4-0 29-10-0 35-5-0 39-7-15 45-4-0
1-8-0 4-9-4 4.9-4 4-9-4 0-1-12 3-10-8 6-4-0 3-6-0 5-7-0 4.2-15 5-8-1
Scale=1:82.7
5x6 = 5x12 =
7 8
.. 3x6
B 9, 3x8
3x8 MT20HS % 26 10 316
2x4
. 5,00 12 5 19 11 27
28 T
4 6x8 =
o
3 .. 20 18 -
12 ,� m
5x8 %25 22 21 17
13
2 4x10 MT20HS 4.00 12 7x10
4
m 1 23
(] 6x8
0
o
24 16 15
4x10 MT20HS 11
ST1.5xB STP = 3x4 11 ST1.5x8 STP =
5x6 6x8 =
FASTEN TRUSS TO BEARING FOR
THE UPLIFT REACTION SHOWN
WHILE PERMITTING NO UPWARD
MOVEMENT OF THE BEARING.
•0 6-5-4 11.2-8 15-11-12 20.9-0 26-4-0 29-10-0 35-5-0
45-4-0
-0- 4-9-4 4-9-4 4-9-4 4-9-4-7-0
9-11-0
0-8-6
Plate Offsets (X Y)-- [1.0-0-0 0-1-7] [7.0-3-0 0-2-4] [8.0-9-12 0-2-8] [14.0-7-7 Edgel fl5.0-2-12 0-3-01 [19:0-3-0 0-4-01
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TIC 0.98
Vert(LL) -0.33 20-22 >999 360
MT20 244/1.90
TCDL 15.0
Lumber DOL 1.25
BC 0.77
Vert(CT)' -0.74 20-22 >549 240
MT20HS 187/143
BCLL 0.0 '
Rep Stress lncr. -.YES
WB 0.93
Horz(CT) 0.48 15 n/a n/a
BCDL 10.0
Code FBC2017[TP12014
Matrix-SH
Wind(LL) 0.41 20-22 >977 240
Weight: 274lb FT=20%
LUMBER- I BRACING -
TOP CHORD' 2x4 SP No.2 *Except` TOP CHORD Structural wood sheathing directly applied.
4-7,10-14: 2x4 SP M 31 BOT CHORD " Rigid ceiling directly applied or 3-0-1 oc bracing.
BOT CHORD 2x6 SP No.2 "Except' WEBS 1 Row at midpt 15-17
1-24,14-16: 2x4 SP No.2, 9-16: 2x4 SP No.3
WEBS 2x4 SP No.3 `Except'
2-24: 2x6 SP N6.2, 2-23: 2x4 SP No.2
SLIDER Right 2x6 SP No.2 3-1-5
REACTIONS. (lb/size) 24=1244/0-8-0, 14=-1011/Mechanical, 15=3847/0-6-0
Max Horz 24=175(LC 16)
Max Uplift 24=-472(LC 12), 14— 1103(LC 23), 15=-1051(LC 12)
Max Grav 24=1244(LC 1), 14=350(LC 12), 15=3847(LC 1).
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-283/140, 2-25=-3537/2111, 3-25=-3402/2112, 3-4=-4266/2707, 4-5=-4205/2715,
5-26=-3503/2233, 6-26=-3494/2249, 6-7=-2110/1199, 7-8=-2051%1197,.8-9=-263/288,
9-10=-737/1688, 10-27=-740/1642,.11-27=-745/1632, 11-28=-1602/3245,
12-28=-1603/3139, 12-13=-1223/2649, 13-14=-1242/2588
BOT CHORD 1-24=-139/292, 22-23=-l943/3388, 21-22=-2402/4090, 20-21=-2388/4107,
19-20=-1790/3356, 18-19= 289/501, 17-18=-1607/1198" 9-17=-1799/1028,
14-15=-2251/1227
WEBS 2-24=-1057/853, 2-23=-1952/3255, 3-23=-533/435, 12-15=-864704, 3-22= 442/692,
8-19=-1117/2278, 8-1 8=-1 160/670, 948=-828/1662, 15-17=-3515/2143, 11-17=-811/1575,
11,-15=-1239/867, 5-20=-759/588, 6-20=-149/387, 6-19=-1289/1136, 7-19=-69/480
NOTES
1) Unbalanced roof live loads have been considered far this design.
2) Wind: ASIDE 7-10; Vult=170mph:(3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=5.opsf; h=15ft; Cat. 11; Exp C; Encl.,
GCpi=0.18; MW.FRS (envelope) and C-C'Exterior(2) 0-0-0 to 6-0-0,.Interior(1) 6-0-0 to 20-0.0, Exterior(2) 20-0-0 to 34-9-13, Interior(1) .'
34-9-13 to 45-4-0 zone; cantilever left:and right exposed ;C-C for members and forces & MW FRS for: reactions shown; Lumber-
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) All plates are 4x6 MT20 unless. otherwise indicated.
6) This.frus6 has been designed for a 1b.0 psf bottom chord live load nonconcurrent with any otherfive loads:
Walter P. Finn PE No.22939
7) ' This truss has,been designed for alive load of.20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom,chord and any dtfierrilembers.MiTek
Inc. FL Cart 6634.
8) Refer to girder(s) fortnlss to miss connections. � "
8904 Parke East Blvd mp a FL 33810.
� ' Tampa
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 472 lb uplift at joint.24, 1.103 lb uplift at
, Date•• .
joint 14 and 1051 16 uplift at joint 15.
"' October 10,20 19
10) This truss has large uplift reaction(s) from gravityload case(s). Proper connection is required to.secure truss against upward
0 WARNING -Verify design parameters and READ NOTES ON.THIS AND INCLUDED MrrEK REFERANCE PAGEM11.7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with Mrrek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a.truss system. Before use, the, building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to buckling Individual truss chord members only.. Additional temporary and permanent bracing
MiTeW
prevent of web and/or
Is always.required for stability and to prevent.collopse with possible personal Injury and property damage. For general guidance regarding the : - ...
.
6904 Parke East Blvd.,
fabrication; storage; delivery, erection and bracing of trusses and truss systems, seeANStMil Qualify Cdtoda, DSB-89 and BCSI BuBding Component:
Tampa, FL 33610,
Safety Infomlatlonavailable from Truss Plate Institute; 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
.:
Job
Truss
Truss Type
QtY
Ply
T18335980
20103091-TNT
C3
Hip
1
1
Job Reference (optional)
F b 11
201 c Print
8 240 s h l 27 2019 MiTek Ind striec Inn Thl, rinr 1n 10.12.47 2019 Pace 2
Bdidem FimiSouruu, ru„ rroun, rL aYara, ....... �............ _._._ _ __. _. __._ ..... _.....___...__. ..._.
1D:PftI_gjXzGof3aThkEwERV6zC114-ERak0isA5hQdCn71AzVUdYgl xW F_bU3GaAlUXCyUsUU
` LOAD CASE(S) Standard
- & WARNING -Verify design parameters and READ NOTES ON. THIS AND INCLUDED MITEKREFERIINCEPAGE'MlIL7473 rev. 1WO312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
��
a.truss system. Before use, the, building designer must verify the applicability of design parameters,and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss.web and/or chord members only.. Additional temporary and permanent bracing,
WWI I.
Is always fequlred-for stability and to prevent. collapse with possible personal Injury andproperty damage. For general guidance regarding the: ..
fabricatlon; storage; delivery, erection and bracing of trusses and truss systems, seeANSI/1PII Quality Criteria, DSB-89 and BCSI BuOding Component:
.
6904 Parke East Blvd..
Safety Inronnationovallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610. .
Job
Truss
I russ I type
Qtyply
T18335981
2ON3091-TNT
C4
Hip
1
1
Job Reference (optional)
..... � _...... ...... ..._... ,. __. _. __. _ .-...
ID:PftLgjXzGof3a: hkEwERV6zC114-ERak0isA5hodCn?IAzVUdYg4vWEfbTRGaAIUXCyUsUU
1-4-0 6-1-12 12-0-14 18-0-0 23.2-0 28-4-0 35-5-0 40-2-12 45-4-0
1-4-0 4-9-12 5-11-2 5-11-2 5-2-0 7-1-0 4-9-12 5-1-4
Scale = 1:78.8
5.00 12 5x8 2x4 II 5x8
6 24 7 25 8
ST1.5x8 STP = zI zn zu 19 za 18 n 16 14 5x8 11
7x10 11 3x6 = 3x8 MT20HS= 3x6 = 5x8 = 3x8 = 3x8 = ST1.5x8 STP=
6x8
3x8 =
1-4-0
1-0- 9-8-0 180-0 23-2-0 28-4-0 35-5-0 45-4-0
-0- 8-4-0 8-4-0 5-2-0 5-2-0 7-1-0 9-11-0
n-a-n
X
LOADING (psf)
TCLL 20.0
TCDL 15.0
BCLL 0.0 '
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Cade FBC2017ITP12014
CSI.
TC 0.79
BC - 0.79
WB . 0.97:
Matrix-SH
DEFL. in (loc) I/dell Lid
Vert(LL) -0.18 19-21 5999 360
Vert(CT) -0.40 19-21 >999 240
Horz(CT) 0.08 14 n/a n/a
Wind(LL) 0.16 19-21 >999 240
PLATES
MT20
MT20HS
Weight: 268lb
GRIP
244/190
187/143
FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 2-10-6
cc pariins.
BOT CHORD 2x4 SP No.2 *Except* BOT CHORD Rigid ceiling directly applied or 4-11-6 cc bracing.
1-20: 2x4 SP No.1 WEBS 1 Row at midpt 6-18, 8-18, 9-16
WEBS 2x4 SP'No.3
SLIDER Left 2xB SP 240OF 2.0E 3-1-8, Right 2x6 SP No.2 2-9-9
REACTIONS. (lb/size) 1=1491/0-8-0, 14=2423/0-6-0, 13=136/Mechanical . .
Max Horz 1=-158(LC 13)
Max Uplift 1=-519(LC 12), 14==733(LC 8), 13=-122(LC 13)
Max Grav 1=1491(LC 1), 14=2423(LC 1),13=217(LC 24)
FORCES.. (lb) -Max. Comp./Max. Ten..- All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-2934/1859, 2-3=-2847/1869, 3-22= 2622/1722,;22-23=-2613/1731, 4-23=-2527/1733,
4-5=-2475/1742, 5-6=-1831/1390, 6-24=-1395/1227, 7-24=-1395/1227, 7-25— 1395/1227,
845=-1395/1227, 8-9=-1056/849, 926=-258/674, 10-26=-261/636, 10-27=-269/582,
11-27=-273/576, 11-12=-75/391, 12-13=a86/366
BOT. CHORD 1-21=-1599/2583,21-28= 1334/2197, 20-28=-1334/2197, 19-20_ 1334/2197, .
19-29=-813/1618, 18-29=-813/1618, 17-18=-307/863, 16-17=-307/863, 15-16=-553/549,
14-15=-553/549, 13-14=-303/160
WEBS 3-21=-288/407, 5-21= 163/465, 5-19=-784/698, 6-19=-390/708, 6-18=-428/273,
7-18= 396/391, 8-18=-691/1001, 8-16=-831/615, 9-16=-1004/1713, 9-14=-2006/1459,
11-14=-474/499
NOTES-
1) Unbalanced, roof live loads have been considered for this design..
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4:2psf; BCDL=5.Opsf; h=15ft; Cat. II; Exp C; Encl.,
GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) 0-4-0 to 6-4-0, Interior(1) 6-4-0 to 18-0-0, Exterior(2) 18-0-0 to,26-5-13, Interior(1)
26-5-13 to 28-4-0, Exterior(2) 28;4-0 to 36-9-13, Interior(1) 36-9-13 to 45-4-0 zone; cantileverleft and right exposed;C-C for members
and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip.DOL=1.60
3) Provide adequate drainage to prevent water.ponding. "
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom; chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all, areas where a rectangle 3-6-0 tall by 2-0=0 wide
will fit between the bottom chord and any other members,: with BCDL = 10.Opsf... "
7) Refer to.girder(s) for truss to truss connections:
8) Provide mechanical connection (by others) of truss to bearing plate capable of. withstanding 519.Ib uplift at joint 1, 733 lb uplift atjoint
14 and 122 lb:uplift atjoint 13.
LOAD CASE(S) Standard
Walter P. Finn PE No.22639 -
MiTek USA, Inc. FL Cent 6634,
$904 Parke East Blvd. Tampa FL 33619.
Date:
October 10,2019
_... ..
Q WARNING - Verify design parameters and READ NOTES ON:THIS AND INCLUDED MITEK REFERANCE PAGE'M11-7473 rev, 1WO312015 BEFORE USE.
Design valid for use only with Mliek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
��
'
a, truss system. Before use, the. building designer must verify the applicability of design parameters, and properly Incorporate this design Into the overall
building design. Bracing Indicated is to buckling individual truss.web members only.. Additional temporary and permanent bracing.
MiTek'
prevent of and/or chord
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding The ...'
fabrication; storage; delivery, erection and bracing of trusses and truss systems, seeANSUIPII Quality Criteria. DSB-89 and BCSI BuBdbp Component:
6904 Parke East Blvd..
Safety Informationovailoble from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. . ' .... .: .. ..... . ..:
Tampa, FL 33610.. .
Job
Truss
russ ype
Qty
T18335982
201b3091-TNT
C5 "
Hip -
1
7Jb
Reference (optional)
rsumers rirsmource, ron riece, rLavevo . — . I — . I - .... - -,,,.....-1 ...- -..- ._.._..---•- . - -
ID:PftLq)XzGof3aThkEwERV6zC114-id86E2tos?YUpxaUkhOj9lNDewbtKwfPpg213ey sUT
1-4-0 8-8-0 16-0-0 23-2-0 30.4-0 35-5=0 40-2-12 45-4-0
1-4-0 7-4-0 7-4-0 7-2-0 7.2-0 5-1-0 4-9-12 5-1-4
5.00 Fi2 5x8 = 2x4 II . 5x8 =
4 22 5 23 6
Scale = 1:78.8
m
N
I
1
ST1.5x8 STP= 19 1B 17 26 16 it) Z/ 14 d 12 5x8 II
5x12 II 2x4 II 3x6 = 5x6 = 3x8 = 3x8 = ST1.5x8 STP
3xB MT20HS = 3x8 =
6x8 =
1-4-0
1-0- a-8-0 16-0-0 23-2-0 30-4-0 35-5.0 45-4-0
7-q-0 7_q-0 7_2.0 1 2-0 5-1-0 9.11-0
0-4-0
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in . (loc)
Udefl
Lid
PLATES
GRIP
TCLL 2010
Plate Grip DOL,
.
1.25
TC 0.92
Vert(LL)
. -0.17 11-12
>712
360
MT20
244/1.90
TCDL 15.0
Lumber DOL
1.25
BC 0.72
Vert(CT)
-0.34 11-12
>350
240
MT20HS
187/143
BCLL 6.0
Rep Stress Incr
:YES
WB 0.98
Horz(CT)
0.08 12
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix-SH
Wind(LL)
0.15 17-19
.>999
240
Weight: 259lb
FT=20%
LUMBER
BRACING -
TOP CHORD 2x4 SP No.2 *Except* TOP CHORD Structural wood sheathing directly applied.
1-3: 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 4-8-15 oc bracing.
BOT CHORD 2x4 SP No.2 *Except . WEBS 1 Row at midpt 3-17, 4-16, 6-16
1-18: 2x4 sP No.1
WEBS 2x4 SP.N6.3
SLIDER Left 2x8 SP e-400F 2.0E 4-6-0, Right 2x6 SP 140.2 2-9-9 .
REACTIONS. (lb/size) 11=109/Mechanical, 12=2458/0-6-0, 1=1483/0-8-0
Max Horz 1=-141(LC 13)
Max Uplift 11=-126(LC 13), 12=-789(LC 8), 1=-504(LC 12)
Max Grav 11=16B(LC 24), 12=2458(LC 1), 1=1483(LC 1)
FORCES.. (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1=2=-2848/1825, 2-20=-2722/1835, 20-21=-2696/1843, 3-21=-2654/1847, 3-4=-2052/1458, " . ..
4-22=-1576/1297, 5-22=-1576/1297, 5-23=-1576/1297, 6-23=-1576/1297, 6-7=-752/659,
7-8=-93W56, 8-24=-337/693, 24-25==341/651, 9-25=-345/643, 9-10=-58/437,
10-11= 72/413 ....
BOT CHORD 1-19=-1561/2513, 18-19=-1563/2509, 17-18- 1563/2509, 17-26=-950/1807,
16-26=-950/1807, 15-16=-149/615, 15-27=-149/615, 14-27=-149/615, 13-14=-640/627,
12=13=-640/627, 11=12==341/148
WEBS 3-19=6/315, 3-17=-806/698, 4-17= 256/568, 4-16=-333/230, 5-16==573/558,
6-16=-912/1362, 6-14=-1059/758, 7-14=-1041/1716, 7-12=-2032/1437,9-12= 532/550
NOTES-
1) Unbalanced_ roof live loads have been considered for this design..
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TiCDL=4:2psf; BCDL=5.Opsf; h=15ft; Cat. II; Exp C; Encl.,
GCpi=0.18; MW FRS (envelope) and C-C Extedor(2) 0-4-6 to 6-4-0, Interior(1) 6=4-0 to 16-0-0, Exterior(2) 16-0-0 to 24-5-.13, Intedor(1)
24+5-13 to 30-4-0, Extedor(2) 30,4-0 to 38-9-13, Interior(1) 38-9-13 to 45-4-0 zone; cantile.ver.left and right exposed ;C-C for members
and forces &MWFRS for reactions shown; -Lumber DOL=1.60 plate grip.DOL=1.60
3) Provide adequate drainage to prevent water.ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been. designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.0psf on.the 'bottom chord in all areas where a rectangle 3-6-0 tall by 2-0=0 wide
:will fit between the bottom chord end any other members,: with. BCDL = I O.Opsf. :
7) Refer to.girder(s) for truss to truss connections:
8) Provide mechanical connection (by others) of truss to bearing plate capable of. withstanding 120,lb uplift at joint 11, 789 lb uplift at
joint 12 and 504 lb uplift at. joint 1.
LOAD CASE(S) Standard
Walter P. Finn PENo.22839
MiTek USA, Inc. FL Cart 6634.
6904 Parke East Blvd. Tampa FL 33810
Date:
::. -October 10,2019
q.
WARNING - Verify design pararnefers and READ NOTES ONTHIS AND INCLUDED MIIEK REFERANCE PAGE 114II.7473 rev. 10103/2015 BEFORE USE,
�� .. ...
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
�
o.truss system. Before use, the.bullding designer must verify the applicability of design parameters.and properly Incorporate this design Into the overall
building deslgn. Bracing Indicated is to buckling of Individual truss and/or members only., Additional temporary and permanent bracing.
MiTek`
prevent web chord
Is always.required for stability and to prevent. collapse with possible personal Injury and property damage. For general guidance regarding the :
fabrication; storage; delivery, erection and bracing of trusses and truss systems, seeANSV1P11 Quality Crkerla, DSB-69 and SCSI BuYdtnp Component:
. -
6904 Parke East Blvd.
Safety Infonnatlonovailoble from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. ..
Tampa, FL 133610. ,
Job
Truss
I russ I ype
Qty
Ply
T18335983
20'f03091-TNT
C6
Hip
11
Job Reference o tional
ounuers ri—auu—, rrn, neon, rL aYaya ., o.. ....,. .,._,.. ....... _. __._ ..... _.....___...__. ..._. ..._ __.. _ . _.._.. _ __ _ _
ID:PftLgiXzGof3aThkEwERV6zC114-id86E2tos?YUpxaUkhOj91NGMwXZKxCPpg213ey sUT
1-4-0 7-8.0 14-0-0 1 23-2-0 32-4-0: 35-5-0 40-2-1245-4-0
1-4-0 6-4-0 6-4-0 9-2-0 9-2-0 4-9-12 5-1-0
c nnF,—,
6x8 =
4
7x10 = &B
205 21 6
Scale = 1:77.4
5x12 II 17 16 zv; 15 1" 13 " 11 5xB II
ST1.5x8 STP 2x4"II 5x6 = Sx8 = 3x8 46=ST1.5x8 STP =
3x8 =
6x8 =
140
1-0- 7-8.0 14-0-0 23-2-0 32-4-0 35-5-0 45-4-0
0 6-4-0 6 4 0 - 9-2-0 9-2-0 3.1-0 9-11-0
LOADING (psf)
SPACING- 2-0-0 .
CS1.
DEFL. in . (loc) I/dell Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.75
Vert(LL) -0.17 15-16 >999 360:
MT20 244/190
TCDL 15.0
Lumber'DOL 1.25
BC= 1.00
Vert(CT)'-9.4315-16 >984 240
BCLL 0.0 .'
Rep Stress Incr YES
WB 0.94.
Horz(CT).. 0.09 11 n/a n/a
BCDL lob
Code FBC2017[TP12014
Matrix-SH
Wind(LL) 0.16 16 >999 240
Weight: 267Ib FT=20% '
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 *Except* TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins.'
5-6,4-5: 2x6 SP No.2 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing:: '
BOT CHORD . 2x4:SP No.2 WEBS 1 Row at midpt -
4-15, 6-15
WEBS 2x4 SP No.3
SLIDER Left 2x8 SP 240OF 2.OE 3-11-8, Right 2x6 SP No.2 2-9-9
REACTIONS. (lb/size) 1=1478/0-8=01.10=91/Mechanical, 11=2480/0-6-0
Max Holz 1=123(LC 16) "
Max Uplift 1=484(LC 12), 10=-118(LC 13), 11=-841(LC 8)
Max Grav 1=1479(LC 23), 10=143(LC.24), 11=2480(LC 1)
FORCES., (lb) - Max.'Comp./Maio. Ten..- All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-2870/1873, 2-18=-2747/1883, 18-19= 2738/1888; 3-19=-2700/1893, 3-4=-2268/1578,
4-20=-1856/1434, 5-20=-1857/1434, 5-21 =-1 857/1434, 6-21 =-1 856/1434, 6-7=-297/344,
7-22==376/802, 8-22=-384/684, 6-23=-57/470, 9-23=-65/465, 9-10=-77/447
BOT'CHORD 1-17=-1608/2536;'16-17=-1608/2536;.16-24=-1097/2007, 15-24=-1097/2007, 14-15=0/298,
14-25=0/298, 13-25=0/298, 12-13=r6B7/639, 11-12=-687/639, 10-11=-370/145
WEBS ... 3-16— 590/577, 4-16=-205/525, 5-15=-7707727, 6-15=-1261/1936, 6-13=-1350/938, w.
7-13= 1028/1695, 7-11=-2063/1405, 8-11— 558/568'
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE.7-10; Vult=170mph'(3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; Cat. II; Exp C; Encl.,
GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) 0-4-0 to 6-4-o;.lntedor(1) 6-4-0 to 14-0-0, Extefl&(2) 14-0-0 to 22-5-13, Intetior(1)
.
22-5-13 to•32-4-0, Exterior(2) 32-4-0 to 40-9=13,.Interior(1) 40-9-13 to 4574-0 zone; cantilever left and right exposed ;C-C for members
and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip'DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord: live load nonconcurrent with any other live loads.
5) *This truss has been designed for a:live-load of 20.Opsf on the bottom chord in all areas where a: rectangle 3-6-0 tall by 2-6-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
6) Refer.to girder(s). for truss to truss connections:
7) Provide mechanical connection (by others) of truss: to bearing plate capable of withstanding 484 lb uplift at joint:l; 1.18 lb uplift at joint
10 and 841 lb uplift atjoint 11:
LOAD CASE(S) Standard
Walter P. Finn PE No.22839'
..... '.: ...
I eInc.e
..
•
mpa
mpa FL
8904 Parke EastBlvd. Ta
Date: - .
...
..
October 10,2019
" WARNING - Veri17 design Parainefers and READ NOTES ON:TH/S AND INCLUDED M/TEK REFERANCE PAGE M/I-7473 rev. 10103)2015 BEFORE USE.
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and Is for an Individual bu11ding component, not
a, truss system. Before use, the. building designer must verify the applicability of design parameters, and properly incorporate this design Into the overall
building deslgn. Bracing Indicated is to buckling of individual truss,web and/or chord members only., Additional temporary and permanent bracing
MITBK•
prevent
Is always required for stability and to prevent.collopse with possible personal Injury and property damage. For general guidance regarding the
.
6904 Parke East Blvd..
fabrication; storage; delivery, erection and bracing of trusses and truss systems, seeANSVIPII Quality Crtlerla, DSB-89 and SCSI Building Component:
Tampa, FL 33610.
Safety Infonnatlonavallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
.
Job
Truss
I russ I ype
Oty
Ply
I
T18335984
20193091-TNT
C7 :
Hip
1
1
Job Reference (optional)
Dunoem rimiouurce, run ri—, — avavu r,,., o.,,'....' i �.. ,.,,, �,. jjCff., -. ...-.-_.._ .._.._ nbb ' -y' .
I D: PftLgj XzG of3aThkEwE RV 6zC114-Bpi U ROtQdJg LR58 g I OXyizvO R Kx03 N rZ2 Unbb4yUsU S
it-4-0, 3-10-0 6-5-10 12-0-0 1$-6-0 19-9-15 27-1-13 34-4-0 39-8-4 45-44 ,
1-4� 0 2-6-0 2-7-9 5-6-6 0-6-0 7-3-15 7-3-15 7-2-3 .1t4 5.7-12
Scale = 1:78.8
3x6 11
5x6 = I 3x6 = 3x8 = 3x6 =
5x6 =
-5.00 12 4 5 6 26 7 27 8 9
223 22J%4 11 2x4 11 15 29 3b 14
18 17 16 13 5x8 11
4x6 = 3x4 II 3x4 I 6x8 = 4x6 2x4 II
3x8 = ST1.5x8 STP=
ST1.5x8 STP = 6x8 =
4x6 =
3x6 I I
1-0- 3-10.0 7-" 12-0-0 1 19-9-15 27-1-13 34-4-0 -5 39-8-4 45-4-0
-0- 2-6-0 3-2-0 5-0-0 0 6- 7-3-15 73-15 7-2-3 -1-0
4-3-0 5-7-12
0-4-0
Plate Offsets (X Y)-- [1.0-0-0 0-1-71 [4.0-3-0 0-2-4] [9:0-3-0 0-2-41 [19:0-4-8 0-3-01
LOADING (pso
SPACING- 2-0-0
CS1.
DEFL. in (loc)... I/deft Ud
PLATES GRIP
TCLL 20:0
Plate Grip DOL 1.25
TC . 0.92
Vert(LL) -0.15 19-20 >999 360.
MT20 244/190
TCDL 15.0
Lumber DOL: 1.25
BC 0.77
Vert(CT) '-0.3519-20 >999 240
BCLL 0.0
Rep Stress Incr . YES
WB 0.98
Horz(CT.). 0.10 14 n/a n/a-
BCDL 10.0
Code FBC2017fTP12014
Matrix-SH
Wind(LL) 0.20 19-20 >999 240
Weight: 257lb FT=20% "
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins.
BOT CHORD 2x4 SP No.2 *Except* BOT CHORD Rigid ceiling directly applied or 4-5-6 oc bracing.
21-22,5-18: 2x4 SP No.3 WEBS 1 Row at midpt " 8-17,
9-16, 9-14
WEBS 2x4 SP No.3
SLIDER Right 2x6 SP No.2 3-1-4
REACTIONS. (lb/size) 12=-119/Mechanical, 23=1490/0-8-0, 14=2704/0-6-0
Max Horz 23=-107(LC 17)
Max Uplift 12= 308(LC 23), 23=-531(LC 8), 14=7949(LC 9) "
Max Grav 12=77(LC 9), 23=1492(LC 23), 14=2704(LC 1)
FORCES." (lb) - Max. Comp./Max. Ten..- All forces 250 (lb) or less except when shown.
TOP CHORD 2-24=-2930/1948, 24-25=-2860/1956, 3-25= 2792/1958, 3-4=-2325/1604, 4-5= 2143/1608,
5=6=-2153/1622, 6-26=-1976/1485, 7-26=-1976/1485, 7-27=-1976/1485, 8-27=-1976/1485,
8-9= 11261993, 9-28=-600/1311, 10-28==601/1181, 10-11=-272/909, 11=12= 286/878
BOTCHORD 2-21=-1685/2574, 20-21=-1690/2640,:19,20=-1690/2640, 5-19=-484/492, 17-18=-96/261,
16-17- 585/1126;15-16=-690/581; 15-29=-690/581, 29-30= 690/581, 14;-30=-690/581,
13-14=-771/351, 12-13=-771/351
WEBS 2-23=-1434/1050, 17-19=-985/1722, 6-17=-622/556,•8-17=-672/1050, 8-16=-1155/895,
9-16=-1385/2236, 9-14=-2224/1415, 10-14=-688/646, 3-19=-605/566, 4-19=-627/854
NOTES-
1) Unbalanced roof live loads have been considered for this design. "
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; Cat. 11; Exp C; Encl.,
GCpi=0.18; MWFRS (envelope) and C-C.Exterior(2) 0-0-0 to 6-070, Interior 1) 6-0-0 to 12-0-0, Exterior(2) 12-0-0 to 20-5-13, Interior(!)
26-5-13 to 34-4-0; Exterior(2) 34-4-0 to 42-9-13, Interior(!) 42-9-13 to 45-4-0 zone; cantilever left and right exposed ;C-C for members
and forces & MW FRS for. reactions shown; Lumber DOL=1,60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding..
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other. live loads.,
5) ' This truss has been designed for a live:load of 20.Opsf on the bottoni:chord in all areas where a rectangle 3-6-0 tall by 2-0-01ivide
will fit between the bottom chord and any otherrilembers, with BCDL=10.Opsf.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to'bearing plate capable of withstanding 308 lb uplift at joint 12, 531 lb uplift at
joint 23 and 949 lb uplift at joint.14. .....
LOAD CASE(S) Standard
Wafter P. Finn PE No.22639
MiTek USA, Inc FL Cert 66U
.. ...
East Blvd Tap 8 804 Pattie Ea Tampa F L:33810.
!)ate:
Octobe r 10,2019
WARNING -Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE 114I1-7473 rev. 10/03/2015 BEFORE USE.
Design valld for use only with MlTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
a.truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design. Into the overall
building design. Bracing Indicated is to buckling individual truss,web chord members only.. Additional temporary and permanent bracing
MoTek'
prevent of and/or
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the:,
fabrication; storage; delivery, erection and bracing of trusses and truss systems, seeANSVTFII Qualify Cdtoda, DSB$9 and BCSI BuBding Component.
.
6904 Parke East Blvd.
Safety Informatlonavailable from Truss Plate Institute, 218 N. Lee Street Suite 312, Alexandria, VA 22314.
Tampa, Fb 33610..
Job
Truss
I russ I ype
City
Ply
T18335985
201b3091-TNT
CB :
Half Hip
1
1
Job Reference (optional)'
omioers nrs[aourcn, ro¢ neca, --.4. . .... I . �.. I I- ......� �, . ......... ...-. ...- __.._ ._.._.__ __._ . _ _ .
I D: PftLgjXzGof3aThkEW ERV6zC114-fOGseku30coC3Fjtr52BEASdBkG9og4iH8X67XyUsUR
,1-4-0 3-10-0 6-5-9 10-0-0 , 12-6-0 18-11-6 25-0-0 30-1-10 31-10-0 35-5-0 40-3-10 45-4.0
° 1-4-0 2-6-0 2-7-9 3-6-7 2-6-0 6-5-6 6-0-10 5-i-10 1-6-6 3-7.0 4-10-10 5-0-6
Scale = 1:78.9
5.00 12
5x6 = 3x4 11 3x8 = 3x8 = 3x4 IISxB 5x6 = 3x6 = 4x6 =
.. =
d 5 bap 7 8 g 10 81.11 12
pm
I
I
�.-
U 3x4 = 24, V 7x10 = -- L_11
227. 26 3x6 — 22 21 20 19 16 15 14 13
46 = 3x4 11 7xl0 = 6x8 3x4 I 2x4 I ST1.5x8 STP = 3x6 = 3x4 I I
ST1.5xB STP 3x4 I
5x8 =
6xB =
46 =
3x6 I I
1-4-0 .. -
1-0- 3-10-0 6-5-9 10-0-0 12-6-0 18-11-6 25-PO 37-10-0 35-5-0 40-3A 45-4-0
-0- 2-6-0 2-7-9 3172-6-0 6-5-6 6-0-10 6-10-0 3-7-0 4-10-10 5-0-6
I9
Plate Offsets (X Y)-- [1.0-0-0 0-1-71 [2.0-2-15 0-1-15] [4:0-3-0 0-2-41 [10.0-3-0 0-3-01
[15:0-3-8 0-3-0J
[18:0-4-12 Loge], 121:U'4-u U-z-41, Z.tage1. 1Z5:U-U-0,u-1-01
LOADING (psf)
SPACING- 2-0-0 ,
CSI.
DEFL.
in . (loc) .. Ildefl Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.66
Vert(LL)
-0.43 17-18 >951 360.
MT20
244/190
TCDL 15.0
Lumber DOL 1.25
BC: 0..80
Vert(CT)
-0.94 17-18 >435 240
BCLL 0.0 -' -
Rep Stress Incr YES
WB... 0.98
Horz(CT)
0.05 13 n/a n/a .
BCDL 10.0
Code FBC2017/TP12014
Matrix-SH
Wind(LL)
0.26 21 .>999 240
Weight: 274lb
FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 2-11-4 oc puffins,
BOT CHORD 2x4 SP No.2 *Except*
except end verticals.
25-26,5-22,8-20: 2x4 SP No.3, 17-18: 2x4 SP M 31
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing,
Except:
WEBS 2x4 SP No.3'Except'
4-0-1 oc bracing: 24-25
6-21,10-15,f 1-14: 2x4 SP No.1, 18-21: 2x4 SP No.2
4-6-0 oc bracing: 23-24
7-8-9 oc bracing: 17-18..
10-0-0 oc bracing: 18-20
WEBS
1 Row at midpt • 21-23, 18-21, 9-17.
REACTIONS. (lb/size) 13=220/Mechanical; 27=1600/0-8-0, 15=2329/0-6-0
Max Harz 27=245(LC 12)
Max Uplift 13=-fO2(LC 8), 27=-566(LC 8),.1 5=-881 (LC 9)
FORCES., (lb) -Max. Comp./Max. Ten.,- All forces 250 (lb) or less except when shown.
TOP CHORD. 2-29=-3174/2040, 3-29=-3036/2041, 3-4=-3150/2223, 4-5=-2962/1966, 5-30=-2931/1956,-
640=-2931/1956, 64= 2930/1765, 7-8=-2930/1765, 8-9=2977/1777, 9-10=-337/535,
10-31= 261/413,11-31=-261/413
BOT CHORD 26-27= 283/171, 2-25=-1815/2770,:24-25=-2099/2857, 23-24=-1713/2499, 5-23=-337/372,
21-22=-203/326, 8-18=-378/330, 17-18=-965/1496
WEBS 2-27=-1549/1161, 4-23=-469/800, 21-23=-1583/2488, 6-21=-610/529, 18-21=-1637/2710,
9-18=-966/1759, 15=17=-1781/1115, 10-17=-381/322,'3-24=-296/442, 4-24=-561/550, "
9-17=-2415/1547, 11-15=-606/418
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; Cat..][; Exp C; Encl.,
GCpi=0.1,8; MWFRS (envelope) and C-C Eztedor(2) 0-0-0 to 6-0-0,1nterior.0) 6-0-0 to 10-0-0, Exterior(2) 1070-0 to 18-5-13, Interior(1)'
18-5=13 to 45-2-4 zone; cantilever left and right exposed ;C-C for members and forces &MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60.
2) Provide adequate drainage to prevent water ponding.... . . .: ..
31 This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any ofher.live loads..
4) ° This truss has been designed fora live; load of 20.Opsf on the bottoin.chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other.members.
5) Refer to girder(s) fortruss:to truss connections.
6) Provide mechanical connection (by others) of truss, to bearing plate capable of withstanding 102 lb uplift at joint 13, 566 lb uplift at
joint 27 and 881 Ib uplift at joint .15.
LOAD CASE(S) Standard
• :: ::
Walter P. Finn PE No 22939
M[Tek USA, Inc FL Cott 6634:
East Blvd Tap 8904 Pattie E Tampa F L 33610:
'.: '.'
Date:
.A.: .. ... .: ..... .... ...
... .... ::. October 10,2019
WARNING - Verify design parameters and READ NOTES ON�THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. f0/03/2015 BEFORE USE.
�� .... .
..
Design valid for use only with MITek® connectors. This design is based only upon parometers'shown, and Is for an Individual bullcjing component, not
Nil
❑.truss system. Before use, the building designer must verify the applicability of design parometers.and properly Incorporate this design Into the overall
buildingdesign. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only.. Additional temporary and permanent bracing
MiTek`
is always required for stability and to prevent. collapse with possible personal Injury and property damage. For general guidance regarding the: ' '
fabrlcatlon; storage: delivery, erection and bracing of trusses and truss systems, seeANSVTP11 Quality Cdteda, DS9•89 and BCSI Building Component:
6904 Parke East Blvd..
safety Infotmatlonavailoble from Truss Plate Institute; 218 N. Lee Street, Suite 312, Alexandria, VA 22314. ..
Tampa, FL 33610.
Job
Truss
russ ype
y
Y
T18335986
20ib3091-TNT
C9 '
Half Hip Girder
1
2
Job Reference (optional)
ounue,a rns,aumce, ruu r,ecn, ram. u•,aYo ,......��..., �.. ..... ., ..,... ,.._,..,...,.. _. __ . _ ..... _.....___...__, . _. ..._ _ _.. _ . _.. _._ _ _ _ _ - _
ID:PftLgjXzGof3aThkEwERV6zC1.14-3bx?HlwxhXAmwiSSXEcusp45cxGk?CpBz61o_ksyU_osUO
114-0 3-10-0 8-0-0 12-6-0 18-11-6 25-0-0 30.1.2 31-10-Q 35-5-0 40-4-8 45.4-0
' 1-4� 0 2-6-0 4-2-0 4-6-0 6-5-65-1-2, 1-8-14 3-7-0 4-11-6 4-11-B
Scale = 1:82.2
NAILED NAILED NAILED NAILED NAILED NAILED
Special NAILED NAILED NAILED NAILED NAILED NAILED NAILED
5.00 12 5x8 NAILED 3x4 11 NAILED 5x8 NAILED 3x4 I I NAILED 4x6 = 3x8 = 5x8 = NAILED 3x8 = 4x6 =
4 an 5q1 nq as as 6 35 36 377 39 39 8 409 41 1042 43 1144 45 46 12
2 _ 25 48 ss Ob 0/ ou —
28 277x10 4x6 = 47 23 49 56 .51 22 52 53 54 21 20 NAILED 5x8 = 16 59 1560 61 1462 63 64 13 .
4x6 = 3x4 11 NAILED NAILED 7x10 NAILED 5x8 = NAILED 3x4 II NAILED 2x4 11 ST1.5x8 STP= 5x8 = 3x6
II
ST1.5x8 STP = 3x4 11 5x12 = 2x4 . .
4x6 —_ NAILED NAILED NAILED 3x6 I NAILED NAILED
NAILED NAILED NAILED 5x12 NAILED NAILED
3x6 NAILED
NAILED
NAILED
I9
140
1-0- 3-10-0 8-0-0 12.6-0 18-11-6 25-0-0 30-1-2
-
1-10-0 35-5-0 40-4-B 4.
-0- 2-6-0 4-2-0 4-6-0 6-5-6 6.0-10 5-1-2
1-6-14 3.7-0 4-11-9 4-11-8
0-4-0
Plate Offsets (X,Y)-- [1:0-0-0,0-1-7]; [2:0-2-13,0.1-11], [4:0-5-12,0-2-8), [6:0-4-0,0-3-0], [11:0-3-8,0-1-8], [17:0.7-8,0-2-8], [18:0-3-8,6-2-8], [19:0-3-4,0-2-4], [22:0-4-0,0-1-8],
[24.04-12 Edge] 126'0-1-12 0-3-8]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.. in
(loc) Udefl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.84
Vert(LL) 0.38
22-23 >999 240
MT20 244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.87.
Vert(CT) -0.55
22-23 >738 240
BCLL 0.0 '
Rep Stress Incr NO
WB 6.62
Hori(CT) 0.11
15 n/a n/a
BCDL 10.0
Code FBC2017/TP12014 .
Matrix-SH
Weight: 554 lb FT = 20%
LUMBER- BRACING-:
TOP CHORD 2x4 SP No.2 `Except' TOP CHORD
Structural wood sheathing directly applied or 4-0-1 oc purlins, except
9-12: 2x4 SP No.1
end verticals.
BOT CHORD 2x4 SP.No.2 *Except* BOT CHORD
Rigid ceiling directly applied or 6.(21-6 oc bracing. Except:
26-27,5-23,7-21: 2x4 SP No.3
4-8-0 oc bracing: 17-18
WEBS 2x4 SP N6.3'Except*
10-0-0 oc bracing: 19-21
19-22;8-19,10-18: 2x4 SP No2,.10-15,2-28: 2x6 SP N6.2
REACTIONS. (lb/size) 13=-754/Mechanical, 15=6425/0-6-0, 28=2682/0-8-0 r
Max Horz 26=198(LC 23)
Max Uplift 13=454(LC 1), 15=-3186(LC 5), 28— 1275(LC 4)
Max Grav 13=417(LC.5), 15=6425(LC 1), 28=2682(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-5500/2685, 3-4=-5750/2886, 4-30=-6934/3536, 30-31=-6934/3536, 5-31=-6933/3536,
5-32=-6816/3486; 32-33=-6816/3486; 33-34=-6816/3486, 6-34= 6816%3486;
6-35=-5131/2622,35-36=-5131/2622,36-37=-5131/2622,7-37=-5131/2622,
7-38=-5206/2643, 38-39=-5206/2643, 8-39=-5206/2643, 8-40=-736/357, 9-40=-736/357,
9-41=-736/357,10-41=-736/357,10-42=-3041/5921;42-43=-3041/5921,43-44=-3041/5921,';
11-44=-3041 /5921, 11-45=-792/1502, 45-46= 792/1502, 12-46=-792/1502,
12-13=-377/852
BOT CHORD 2-26=-2383/4843, 25-26=-2563/5028, 25-47=-2712/5308, 47-48=-2712/5308,
24-46=-M 2/5308, 5-24=-756/594, 23-49=-407/955, 49750=-407/955, 50-51=-407/955,.
22-51=-407/955, 22-52=-100/429, 52-53=-100/429,53-54=-100/429, 21-54=-100/429;
' 19-21=0/270, 7-19— 566/429, 19-55=-357/736, 55-56= 357/736, 18-56=-357/736, '
18-57=6168/3166, 57-58=-6167/3167, 17-58= 6166/3167, 15-60=-599/306,
60-61=599/306, 61-62=-599/306, 14-62=-599/306
WEBS 3-25=-383/538, 4725=-283/711, 4-24=-975/1914, 22-24=-2471/4818, 6-24=-696/1177,
6r22=-1144/9d2,19-22=-2804/5393, 6-19=-670/300; .15.17=-6218/3280, 10-17= 4128/2315, :
11 -1 4=-592/1568, 12-14-1906/1002, 2-28=-2551/1251., 3-26=-315/198, 8-19=-2547/4975;
8-18=-2613/1439, 10-18=-3907/7659, 14-17=-922/497, 11-17==4960/2525
NOTES-
:1) 2-ply truss to be connected together with 10d (0.131 "x3") nails as follows:
Top chords connected as follows: 2x4 -.Prow at 0-9-0 oc.
Bottom chords connected as follows: 2x4 - 1 rove at 0-9-0 oc. Walter P. Finn PE No.22839
Webs connected as follows:_ 2x4 - 1 raw Elf 0-9-0 oc, 2x6,- 2 rows staggered of 0-9-0 oc.. Mi rok USA, Inc. FL Cert 8834
2) All.loads are considered equally applied to all plies; except it noted as front.(F) or back (B) face in the LOAD CASE(S)'section. Ply to 8904 Parke East Blvd. Tampa FL 33810;
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. Ua t e:
3) Wind: ASCE.7-10; Vult=170mph-(37second gust) Vasd=132mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; Cat,:][; Exp C; Encl., October 10,2019
GC i—d 18: MWFRS (envelo e)• cantilever left and right exposed - Lumber DOL=1 60 plate gripDOL=1 60
P— P
- WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE Mll-7473 rev. 10/03/201S BEFORE USE.
Design valid for use onlywith MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not•
a truss system. Before use, the. building designer must verify the applicability of design parometers.and properly incorporate this design into the overall
building design. Bracing indicated Is to buckling individual truss chord members only. Additional temporary and permanent bracing
prevent of web and/or
Is always.recluired for stability and to prevent, collapse with possible personal Injury and property damage. For general guidance regarding the : ......
8 .
6904 Parke East Blvd.. -
fabrication; storage; delivery, erection and bracing of trusses and truss systems, seeANSI/1PI1 Quality Cdteda, DSB-89 and BCSI Building Component:
Tampa, FL 33610.
Safety Infomratlonavailable from Truss Plate Institute; 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
o
russ
I russ I ype
ty
Ply
.
T18335986
20?03091-TNT
C9
Half Hip Girder
1
2
Job Reference (optional)
dunaers rust,ource, r-on Mece, rL J4a40 , o ,, , , �a�
ID: Pit LgXzGof3aThkEwERV6zC114-3bx2HlwxhXAmwiSSXEcusp45cxGk7Cp8z61oksyUsUO
NOTES-
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) *This truss has been designed for alive load of 20.Opsf on the bottom. chord in all, areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any
other members.
7) Refer to girder(s) for truss .to truss connections.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 754 lb uplift at joint 13, 3186 lb uplift at joint 15 and 1275 lb uplift at joint 28.
9) "NAILED" indicates 3-1 Od (0.148"x3") or 3-12d (0.148"x3.25") toe -nails per NDS guidlines.
10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 163. lb down and 221 lb up at 870-0 on top chord. The design/selection
of such connection device(s) is the responsibility of others.
LOAD CASE(S) Standard
1) Dead.+ Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform' Loads (p(f)
Vert: 1-4=-70, 4-12=-70, 1-27=-20, 24-26=-20, 21-23=-20, 20-21=-20,"17-19=-20, 13-16= 20
Concentrated Loads (lb)
Vert: 4— 127(B) 25=-458(B=-76) 18=-226(B) 30=-127(B) 31==127(B) 32=-138(B) 33=-138(B) 34=-138(B) 35=-138(B) 36=-138(B) 37=-138(B) 40=-138(B) 41=-138(B)
42=-138(B) 43— 138(B) 44=-138(B) 45=-138(B) 46=-138(B) 47=-76(B) 48=-76(B) 49=-57(B) 50=-57(B) 51=-57(B) 52=-57(B) 53=-57(B) 54=-57(B) 55=-226(B)
56=-226(B) 57=-57(B) 58= 57(B) 60= 57(B) 61=-57(B) 62=-57(B) 63=-57(B) 64=-57(B)
- 0 WARNING -Verity design parameters and READ NOTES ON THIS AND INCLUDED MfTEK REFERANCEPAGE 11411-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not•
a truss system. Before use, the.bullding designer must verify the applicability of design parameters.and properly Incorporate this design Into the overall
building design. Bracing Indicated9sfo buckling of individual trusstweb chord members only.. Additional temporary and permanent bracing
M!Tek'
prevent and/or
Is always required for stability and to prevent. collapse with possible personal Injury and'property damage. For general guidance regarding the:
.
6904 Parke East Blvd,
fabrication: storage; delivery, erection and bracing of trusses and truss systems, seeA NSUTPII Qualify Cdterla, DSO-89 and BCSI Building Component.
Tampa, FL ,33610..
Safety Infomlationavallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexondrlo, VA 22314.
Job
ruse
Truss Type
Qty
Ply
T18335987
20T03091-TNT
�"Ji
Jack -Open
14
1
Job Reference (optional)
eunaers rnsroource, roa riece, rL avevo
B
ID:PftLgjXzGof3aThkEwERV6zC1.14-3bx?HlwxhXAmwiSSXEcusp4H9xTu?QBBz6loksyUsUO
1-11-4
1-11-4
3x12 MT20HS I I
ST1.5x8 STP =
m
m
0
Scale '=1:9.4
Plate Offsets (X Y)-- [1.0-1-11 0-0-11 [1.0-2-7 Edgel
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in . (loc) - I/dell Ud
PLATES GRIP
TCLL 2010
Plate Grip DOL 1.25
TC 0.10
Vert(LL) 0.00 1 >999 240
MT20 244/190
TCDL 15.0..
.
Lumber DOL 1.25
BC 0.03
Vert(CT) -0.00 1 >999 240
MT20HS 187/143
BCLL 0.0 .'
Rep Stress Incr YES
WB.. 0.00
Horz(CT) -0.00 2 n/a n/a
BCDL 10.0
Code FBC2017/iP12014
Matrix-P
Weight: 10 lb FT = 20%
LUMBER- BRACING-
• TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 1-.11-4.oc purlins.
BOT CHORD 2x6 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEDGE '
Left: 2x6 SP No.2
REACTIONS. (lb/size) 2=65/Mechanical, 3=19/Mechanical, 1=84/0-8-0 "
Max,Horz 1=52(LC 12)' .
Max Uplift 2=-57(LC 12), 3=-26(1_C 8), 1=-47(LC 8) .
Max GraV 2=65(LC 1); 3=37(LC 3), 1=84(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. .
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4:2psf; BCDL=5.Opsf; h=15ft; Cat, II; Exp C; Encl.,
GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone, cantilever left and right exposed ;C-C for members and forces & MWFRS
for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) All:plates are MT20 plates unless otherwise indicated.
3) This -truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
:
4) ' This truss has been designed for a live load of 20.Opsf on the bottom'chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Refer to girder(s) for: truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding, 57 Ito uplift at joint 2, 26 )b uplift at joint 3
and 47 lb uplift at joint 1.
LOAD CASE($) Standard
•
Walter P. Finn PE No.22839
MiTek USA, Inc FL Cert 6634:
•
8904 Parke EastBlvd.Tampa ampa FL 33810.
a e:
,
Octobeir 10,2019
® WARNING -Verify design parameters and READ NOTES ON.THIS AND INCLUDED MITEK REFERANCEPAGEMX7473 rev. IW03120r5 BEFORE USE.
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the. building designer must verity the applicability of design parametersand properly Incorporate this design Into the overall
building design. Bracing Indicated Is to buckling of individual truss,web and/or chord members only.. Additional temporary and permanent bracing
Welk'
prevent
Is always required for stability and to prevent.collopse with possible personal Injury and property damage. For general guidance regarding the:
.
-
fabrication. storage; delivery, erection and bracing of trusses and truss systems, seeANSIMIJ Qualify Cdteda, DSB$9 and BCSI Bu9ding Component.
6904 Parke East Blvd.
Tampa, FL 33610
Safety Infomratlonovaiiable from Truss Plate Institute; 218 N. Lee Street, Suite 312, Alexandria, VA 22314. ..
.
Job
Truss
Truss Type
Qty
Ply
T18335988
20103091-TNT
CJ3'
CORNER JACK -
12
1
Job Reference (optional)
oumers rnsraource, ron riece, rL eveva
1
ID:PftLgjXzGof3aThkEwERV6zC114-3bx7HlwxhXAmW SSXEcusp4GcxS27 PQ8z61oksyUsUO
1-4-0 4.0-0
1-4-0 2-8-0
�~� ST1.5x8 STP =
m
N
co N
W
Scale = 1:13.7
LOADING (pso
SPACING- 2-0-0
CS1.
DEFL. in (lac) . I/dell Lid
PLATES GRIP
TCLL 20;0
Plate Grip DOL 1.25
TC .0.14
Vert(LL) _ -0.00 4-5 >999 360
MT20 244/190
TCDL 15.0
Lumber DOL 1.25
bC 0.08
Vert(CT) -0.00 4-5 >999 240
BCLL 0.0 '
Rep Stress Incr YES
WB. 0.11 :
Horz(CT) -0.01 3 n/a .: n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix-P
Wind(LL) 0.00 . 4-5 .>999 240
Weight: 13lb FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc puffins.
BOT CHORD 2x4 SP No.2 BOT CHORD "' Rigid ceiling directly applied or 10-0-0 oc bracing. -
WEBS 2x4 SP No.3
REACTIONS. (lb/size) ' 3=70/Mechanical, 4=16/Me6hanical, 5=268/0-8-0
Max Horz5=103(LC 12)
Max Uplift 3=-71(LC 12), 4=-1(LC 12), 5=-103(LC 8)
Max:Grav 3=70(LC 1), 4=39(LC 3), 5=268(LC 1) .
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250.(Ib) or less except when shown.
WEBS 2-5=-205/371
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3=second gust) Vasd=132mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; Cat. Il; Exp C; Encl.,
GCpi=0.18; MWFRS (envelope) and C-C Exterior(?) zone; cantilever left and right exposed ;C-C for members and forces & MW FRS
for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for. a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed fora live load of 20.Opsf on the bottom Chord in all areas where.a rectangle 3-6-0 tall by 2-0-0-wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 71 lb uplift at joint 3, 1 lb uplift at joint 4
and 103 lb uplift at joint 5.
LOAD CASE(S) Standard
" _
Walter P. Finn PE No.22639
..... . . ..... .
R1iTek USA, Inc. FL Cert663¢
.. ... .
8984 Parke East Blvd Tampa FL 33610
Date: .
October ,
A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MIP7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MITekO connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a.truss system. Before use, the building designer must verify the applicability of design parameters, and properly Incorporate this design Into the overall
building design. Bracing Indicated is to buckling of individual truss Web and/or chord members only.. Additional temporary and permanent bracing
MiTek'
prevent
Is always required for stability and to prevent. collapse with possible personal Injury and property damage. For general guidance regarding the,
. .
6904 Parke East Blvd., -
fabrication; storage; delivery, election and bracing of trusses and truss systems, seeANSVIPII Quality Criteria. DSB-89 and BCSI BuIl lnp Component.
Tampa, FL 33610..
Safey Infonnationovailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. .. ..... ....
.
Job
Truss
Truss Type
Qty
ly,
T18335989
201b3091-TNT
CJ5
CORNERJACK
8
d
Job Reference (optional)
eumers Firmource, Fort Piece, FL 34945 nun: 8.240 s Feb 11 2019 rnnr, 8z40 s dui 27 2019 rvi i en a iuuswes, a iu. POu ya
ID:PftLgjXzGof3aThkEwERV6zC114-XnVNU5xZSrldYsle4x77cLz iWr 19Q6IyUsU,N
1-4.0 6-0-0
1-4.0 4-8.0
Scale = 1:22.0
1
ST1.5x8 STP
3x12 MT20HS I I'
100 '
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc) .
I/defl
Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.55
Vert(LL)
. -0.02
4-5
'>999
360
MT20
244/190
TCDL 15.0
Lumber DOL
1.25
BC 0.31
Vert(CT)
-0.04
4-5
>999
240
MT20HS
187/143
BCLL 0.0 '
Rep Stress Incr
YES
WEI 0.17
Horz(CT)
-0.04
3
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix-P
Wind(LL)
0.03
.4-5 :
>999
240
Weight: 20lb
FT=20%
LUMBER- BRACING -
TOP CHORD- 2x4 SP No.2 ' TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2X4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4:SP No.3
REACTIONS. (lb/size) 3=141/Mechanical, 4=49/Mechanical, 5=345/0-8-0
Max Horz 5=150(LC 12) ..
Max Uplift 3=422(LC 12), 5=-112(LC 8)
Max Grav 3=141(LC 1), 4=83(LC 3), 5=345(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP.CHORD 1-2=,367/1.46
BOT CHORD 1-5=-114/317
WEBS 2-5=-315/567
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; Cat. 11; Exp C; Encl.,
GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS
for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) All plates are MT20 plates unless otherwise indicated.
3) This truss has been designed for a:10.0 psf bottom_ chord live load nonconcurrent with any other live loads.
4) • This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Refer to girder(s) for truss to trues connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 122 Ib uplift at joint 3 and 112 lb uplift at
joint 5.
A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M/14473 rev, 101aX2015 BEFORE USE.
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and is for an Individual bulldind component, not
a. truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design, Bracing Indicatedisto buckling of Individual truss web and/or chard members only., Additional temporary and permanent bracing.
MiTek"
prevent
Is always required for stability and to prevent, collapse with possible personal Injury and property damage. For general guidance regarding the ' .. .
.
fabrication;. storage, delivery, erection and bracing of trusses and truss systems, seeANSU1P11 Quality Criteria, DSB-89 and SCSI BuBding Component:
6904 Parke East Blvd.-
Safety Informatlonavallable from Truss Plate Institute; 218 N. Lee Street, Suite 312, Alexandria, VA 22314. .....
Tampa, FL 33610
o
russ
russ ype
ty
y
. T18335990
E0103091-TNT
CJ31 'Comer
Jack
2
1
Job Reference o tional
ounoers nrstoource, run nece, r aY
1
ID:PftLgjXzGof3aThkEwERV6zC114-XnVNU5xZSrldYs1 e4x77POcRLLoHksklBmVMGIyUsUN
4.0-0
2-8-0
2x4 116
ST1.5x8 STP =
1-0-0 1.4-0 , 3-10-0 4-0-p
Scale=1:13.7
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL. in
(loc), I/defl L/d
PLATES GRIP
TCLL : 20.0
Plate Grip DOL,
1.25
TC . 0.14
Vert(LL) -0.00
2-4 >999 360
MT20 244/190
TCDL 15.0
Lumber DOL
1.25
BC 0.08
Vert(CT) -0.00
2-4 >999 240
BCLL 0.0 '
Rep Stress Incr
YES
WB' 0.11
Horz(CT) -0.01
3 n/a .' n/a
BCDL 10.0
Code FBC20171TP12014
Matrix-P
Wind(LL) 0.00
.:5-6 >999 240
'Weight:17lb FT=20%
LUMBER-
"
..
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood. sheathing directly applied or 4-0-0 oc purlihs.
BOT CHORD 2x4 SP No.2 *Except*.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
4-5: 2x4 SP No.3
WEBS 2x4 SP,No.3
REACTIONS. (lb/size) 3=70/Mechanical, 4=36/Mechanical, 6=290/0-8-0
Max Horz6=103(LC 12) '
Max Uplift 3=-71(LC 12), 6=-92(LC 8)
Max Grav 3=70(LC 1); 4=80(LC 3), 6=290(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250.(Ib) or less except when shown.
WEBS 276=-230/359
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; Cat. II; Exp C; Encl.,
GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS
for reactions shown; Lumber DOL=1.60 plate grip:DOL=1.60
2) This trilss.has been designed for a.10.0 psf bottom chord live load noiicohcurrent with any other live loads:
3) ' This truss has been designed for a rlive load of;20.Opsf on the bottofrl chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit -between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 71 lb uplift at joint 3 and 92 lb. uplift at
joint 6.
LOAD CASE(S) Standard
Q WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED M/TEK REFERANCE PAGE14II-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
��
a.truss system. Before use, the. building designer must verify the applicability of design parameters, and properly Incorporate this design Into the overall
building deslgn. Bracing Indicated isto prevent buckling of individual truss web and/or chord members only.. Additional temporary and permanent bracing
MiTek°.
Is always required for stability and to prevent.collopse with possible personal Injury and property damage. For general guidance regarding the:
fabrication: storage; delivery, erection and bracing of trusses and truss systems, seeANSVIPII Cual9y Cilteda, DSB-89 and SCSI Building Component:
.
6904 Parke East Blvd..
Safety Infonnatloravailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314,
Tampa, FL 33610.. .
Job
Truss
Truss Type
Qty
Ply
T18335991
2o1b3091-TNT
CJ51'
Comer Jack
2
1
Job Reference (optional)
eumers mrsrsource, rort riece, rL wave
0
nuq: o.cYu a - i I cu.a nu . o.cYu a uui a cu, a �.n, cn ,,,u'au,eo,
I D:PftLgjXzGof3aThkEwERV6zC1.14-XnVNU5xZSrldYste4x77POcLHLklkrfl BmVMG IyUsUN
1-4-0 3.10.0 6-0.0
1-4-0 1 2-6-0 2-2.0
ST1.5x8 STP =, "
3x6 II
1__00
1.0-0
Scale = 1:20.9
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc): I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC - 0.53
Vert(LL) -0.03 5 >999 360
MT20 244/190
TCDL 15.0
Lumber DOL. 1.25
BC - 0.34
Vert(CT) -0.07 5 >821 240
BCLL 0.0
Rep Stress Incr I YES
WB 0.18
HOrz(CT). -0.04 3 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix-P
Wind(LL) 0.02 .. 6 >999 240
Weight: 24 lb FT = 20%
LUMBER- BRACING-
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP No.2 *Except*. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
5-6: 2x4 SP No.3
WEBS 2x4 SP No.3
REACTIONS.. (lb/size) 3=1 41 /Mechanical, 4=61/Mechanical; 7=380/078-0
Max Horz 7=150(LC 12) ;
Max. Uplift 3=-120(LC 12), 7=-94(LC 8)
Max Grav 3=141(LC 1'), 4=107(L63), 7=380(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250.(Ib) or less except when shown.
TOP CHORD, 1-2=-373/149
BOT CHORD 1-7=-114/317
WEBS 2-7=-396/590 . .... . .: ..:.. .
NOTES-
1) Wind: ASCE 7-10; Vult=170mph.(3-second gust) V.asd=132mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; Cat. ll; Exp'C; Encl.;
GCpi=0.18; MWFRS (envelope) and GC Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS
for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads:
3) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer. to girder(s) for truss to tress connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of. withstanding 120 lb uplift at joint 3 and 94 lb uplift at.
joint 7.
LOAD CASE(S) Standard
t.
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cert 669.
6904 Parke East Blvd. Tampa FL33610.
Date:
October 10,2019
. ' & WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the, building designer must verify the applicability of design parameters.and properly Incorporate this design Into the overall
building design. Bracing Indicated is to buckling Individual truss.web and/or chord members only.. Additional temporary and permanent bracing.
MOW
prevent of
Is always required for stability and to prevent.collopse with possible personal Injury and property damage. For general guidance regarding the.
. .
6904 Parke East Blvd.
fabrication; storage; delivery, erection and bracing of trusses and truss systems, seeANSI/IPII Quality Criteria. DSB-69 and BCSI Buldtng Component:
Tampa, FL 33610.
Safety Informationavollabie from Truss Plate Institute; 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
.
Job
Truss
russ ype
ty
ly
T18335992
201�3091-TNT
D1 _
Common Girder
1
1
Job Reference (optional)
tsumers rusrbource, fort niece, M 34e4o �, _ .
ID:P.ftLgjXzGof3aTh, Ew;gV6zC114-?z3ii` yBk9QU90c4eQxE9Ui136TDmRQQEvpkyUsUM
5-11-5 11-8-0 17-4-11 23-4-0
5-11-5 .5-8-11 5-8-11 5-11-5
13
7x10.=-
.2x4 11
..ST1.5xB STP = ..
Scale = 1:38.8
4x6 =
4
HHUS26-2 LUS26 7x10 = LUS26
LUS26
LUS26 - LUS26 'ST1.5xB STP.=
2x4 II 7xl0 =
LUS26
1-0-0 5-11-5 11-8.0 17-4-11
22-4-0 23-4-0
1-0.0 4-11-5 5=8-11 5-8-11
4.11-5
Plate Offsets (X Y)-- [1.0-4-10 0-4-41 [7.0-0-5 0-4-4] r9.0-5-0 0-4-81
LOADING (psf)
SPACING- 2-0-0 .....
CSI.
DEFL. in . (loc)... I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 125
TC 0.68
Vert(LL) 0.09 9-10 >999 360; .
MT20 244/1.90
TCDL 15.0
Lumber DOL : 1.25
BC : 0.43
Vert(CT) : -0.13 B-9 >999 240
BCLL 0.0.''
Rep Stresslncr NO
WB.,.0.50_
Horz(CT) -0.03 7 n/a n/a
BCDL 10.6
Code FBC201WTP12014-
Matrix-SH'
Wind(LL) 0.11 :8-9'..>999 240
Weight: 137lb FT=20%
LUMBER-BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood_sheathing directly applied or 3-11711: oc puffins.
BOT CHORD 2x6'SP M 26 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 2x4SP No.3
.... ..
SLIDER Left 2x6 SP No.2 2-9-1 1, Right 2x6 SP 1\16.2 2-9-11
REACTIONS.. .(Ib/size) 1=861/0-8-0, 7=73210-8-0
Max Horz 1=102(LC 8):
Max:Uplift 1=-962(LC 8); 7=-1431,(1[=C 9)
Max Grav 1=1052(LC 40), 7=1206(LC 41)
FORCES. (lb) - Max..Comp./Max. Ten. -All forces 250,(lb).or less except when shown...
TOP CHORD..1-2=-2159/2095, 2-3=-2084/2106, 3-4=-15,7,l686,.4r5=-1588/1688, 5-6= 2151/2536, :.
6-7= 2275/2512
BOT CHORD 1 -1 0=-1 934/1968, 10=11=-I934/1968, 11-12=-1934/1968,;9-12= 1934/1968,
9-13==2245/2037; 13-14=-2245/2037; 14=15=-2245/2037, 8-15=-2245/2037,
B-16=-2245/2037, 16-17=-2245/2037;:7-17=-2245/2037
WEBS 4-9=71068/901, 5-9=-687/1022, 5-8=-667/368,.3-.9- 559/568, 3-10=-375/368
_. _.
NOTES-
1) Unbalanced: roof live loads have been considered for this design.
2) Wind: ASCE 7-10; V61t=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=5.0psf; h=15ft; Cat. II; Exp:C; Encl:,
GCpi=0.18; MWFRS (envelope);: cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
3) This truss has been designed fora 10.0 psf bottochord' live load nonconcurrent with any other live loads.. "
m
4) 'This truss has been designed for live: load. of.20.0psf on the bottom chord in all areas where a. rectangle 3-6-0 tall by 2-0-0 w.ide :
will fit between the bottom chord and any other,members.
5) Provide mechanical connection .(by others) of truss: to bearing plate capable of withstanding, 962'Ib uplift at joint:1and 1431; lb uplift at
joint 7.
6) Use Simpson Strong -Tie HHUS26-2 (14-10d Girder, 6.10dTruss, Single Ply Girder) or equivalent at 8-1-8 from the left end:to connect
truss(es) C9. (2 ply 2x4 SP) to front face of.bottom chord. pp sd
7) Use Simpson Strong -Tie LUS26 (4-1 Oil Girder, 3-10d Truss, Singie:PlyGirder) or equivalent spaced:at 4-0-0 oc max. starting at:
10-0-12 from the left end to 16-0-12.to connect truss(es) C8 (1 ply 2x4 SP), C6 (1 ply 2x4 SP), C5 (1 ply 2X4:SP) to front face:of
bottom chord.
8) Use Simpson Strong -Tie LUS26 (4-10dx1 1/2 Girder, 3-10d Truss, Single Ply Girder) or equivalent spaced at 6-010 oc max: starting at
12=0-12 from the left.end to 18-0-12 to connect truss(es)-C7 (.1: ply 2x4 SP), C4 (1 ply 2x4 SP.) to front face of bottom chord::
9) Use Simpson Strong -Tie LUS26 (4.-SD9112 Girder, 4-SD9212 Tniss,.Single Ply Girder) or equivalent at 20-0-12 from the left end to
connect truss(es) (1 ply 2x4 SP).to front face of bottom chord..
Walter P. Finn PE No.22839
.C3
10) Fill all nail holes where hanger in contact with lumber..
ldi rek USA, lKc. FL Cert 6634.
... -is
1 1)In the LOAD CASE(S) section,: loads applied to the face of the truss are noted as front (F) or back (B).
East Blvd Tampa F
0904 Parke Ea m a L 33610.
pate:
LOAD CASE(S) Standard
October 10,2019
. ' WARNING -Verity design parameters and READ NOTES ON:THIS AND INCLUDED MfrEK REFERANCE PAGE 111II-7473 rev. 1010312015 BEFORE USE.
Design valid for use only MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
.with
a.truss system. Before use, the, building designer must verify the gpplicabllity of design porameters.and properly incorporate this design Into the overall
building deslgn. Bracing Indicated'Isto prevent buckling of Individual truss.web and/or chord members only.. Additional temporary and permanent bracing.
MOW '
is always reciulred for stability and to prevent. collapse with possible personal injury and property damage. For general guidance regarding the: . .
fabrication,: storage; delivery, erection and bracing of trusses and truss systems, seeANSUfPIt Quality Cdtorla, DSB-89 and Best Building Component:
. ..
6904 Parke East Blvd..
Safety Infonnatlonavailable from Truss Plate Institute: 21 B N. Lee Street, Suite 312,'Alexandria, VA 22314. .:
Tampa, F4 33610.. ' .
Job
russ
Truss Type
ty
y
T16335992
20r'03091-TNT
D1
Common Girder
1
1
Job Reference (optional)
OUOuers rlrsrouuruu, ruR rleue,. rL J9 0 nun] s . Irl " < n .oa, , - . - - .a y
ID:PftLgjX Gof3aThkEvvERV6zC114-?z3liRyBC9QU90cgefeMxE9UiI36TDmRQQEvpkyUsUM
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-4=-70, 4-7— 70, 1-7=-20
Concentrated Loads (lb)
Vert: 11=438(F) 12=-196(F) 13=94(F) 14=-123(F) 15=-148(F) 16=-197(F) 17=580(F)
WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED M/TEK REFERANCE PAGE MIP7473 rev. 1010312015 BEFORE USE.
_.
Design valid for use only with MRek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verlfy the applicability of design parameters.and properly incorporate this design Into the overall
building deslgn. Bracing indicated isto prevent buckling of individual truss web and/or chord members only., Additional temporary and permanent bracing
Mi iT
BK•
Is always required for stability and to prevent. collapse with possible personal Injury and property damage. For general guidance regarding the'
.
fabrication; storage; delivery, erection and bracing of trusses and truss systems, seeANSVIPII Cua1Hv CrIteda, DSB-89 and BCSI Bullding Component
6904 Parke East Blvd.,
Safety Infonnatlonavallable from Truss Plate Institute; 218 N. Lee Street, Suite 312, Alexandrla, VA 22314.
Tampa, FL '33610.. . .
Job
Truss
Truss Type
uty
Ply
T18335993
201b3091-TNT
D2
Hip
1
1
Job Reference (optional)
CU110ers rnSRlUUme, tort rleCe, rL 44e40 nun: v.Zqu s reo I I eu Is rpm: megv s JW - ZU I y ......00 4— rayc ,
ID: PftLlXzGof3aThkEwERV6zC114-?z3li RyBC9QU90cgefeMxE9V FIxKTHoRQQEvpkyUsUM
1-4-0 i 5-8-4 10.0-0 - 13-4-0 17-7-12 i 22-0-0 23-4-0
1-4-0 4-4-4 4-3-12 3-0-0 4-3-12 4-4-0 �1-4-0
,Scale = 1:39:4
4x6 =
5x8 =
4 5
r7
0
ST1.5x8 STP = 3x8 = 5x6 = - ST.1.5x8 STP
3x12 MT20HS I I 3x12 MT20HS 11
23-4-0
i n-n.n. —A.n .. . 77.0-0 ..22-4.0
m
T
v
Plate Uttsets my)- 11:0-U7U U-U-1b1 lb•U-b-12'U-2-81 l9•u-2-/ tagel 11u•U-3-U u-3-uJ 1T2'U-2-/ tagei
LOADING (pso
-SPACING- 2-04
CSI.
DEFL. in (loc).. I(defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1:25
TG 0.58
Vert(LL) -0.15 10-11 i999 .360
MT20 244/1.90
TCDL 15.0
Lumber DOL 1.25
BC 0.93
Vert(CT) -0.28 10-11 >873 240
MT20HS 187/143
BCLL 0.0 '
Rep Stress [nor YES
WB 0.25
Horz(CT) _ 0.04 9 n/a n/a
BCDL 10.0
Code FBC2017/T012014
Matrix-SH
Wind(LL) 0.21 10-11 .>999 240
Weight: 108lb FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 31 *Except*:: TOP CHORD Structural wood.sheathing directly applied or 5-4-1 os purlins.
4-5: 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or
2-2-0 oc bracing, Except:- .
BOT CHORD :2x4 SP No.2 7-7-1 oc bracing: 10=11.
WEBS 2x4 SP No.9 "
REACTIONS.. (lb/size) 12=1050/0-8-0,.9=1050/0-8-0
Max,Horz 12=90(LC 16):
Max:Uplift 12=-355(LC 12),; 9--355(LC 13)
FORCES. (lb) -Max. Comp,/Max. Ten. -All forces 250:(Ib) or less except when shown.
TOP CHORD 1-2=-1091/634, 273=-1367/1016, 3-.13=-.1183/848, 4-13=-1152186.1, 4-5=71067/881,
5-14=-1152/861, 6-14=-1183/849, 6-7=-1367/1016; 7:8=-1091/634 "
BOT CHORD 1-12=-753/1146, 11-12=-77641146, 10-11=-515/1067, 9-10=-753/1146, 8-9=-753/1146
WEBS: 3-11 =-1 27/272, 6-10=-127/272, 2-12= 699/828, 7-9=-699/828:
NOTES-
1) Unbalanced roof live. loads have been considered:for this:design.
"
2) Wind: ASCE 7-10; Vult=170mph (37second gust) Vasd=132mph;.TCDL=4.2j5sf; BCDL=5.Opsf; h=15ft; Cat, II; Exp C; Encl.,
GCpi=0.18; MW FRS (envelope) and C-C Exte.rior(2) 0-0-0 to 6-0-0, Interior(1) 6-0-0 to 10-0-0, Exterior(2)10-0-0 to 22-0-0, Interior(1)
22-0-0 to 23-4-0 zone; cantilever left and right exposed ;C-C for members and forces. & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding:
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed fora live load of.20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-O.wide ; , .
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to:bearing plate capable of withstanding 355 lb uplift at joint 12 and 355 lb uplift at
joint 9. ." .... . .:
LOAD CASE(S) Standard
Walter P. Finn PE No.22839
.
PdTek USA, Inc. FL Carl 6634.
6904 Parke Blvd.Tampa ampa FL 33810
East
Oats:
co"er 10,2019
...... .. . . ... . ...
- WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCEPAGE'M11-7473 rev, 1WO312015 BEFORE USE.
_.i.
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the. bullding designer must verjfy the applicability of design parameters.and properly Incorporate this design Into the overall
building design. Bracing indicated Is to buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
M1Tek`
prevent
Is always required for stability and to prevent. collapse with possible personal Injury and property damage. For general guidance regarding the:
.
fabrication; storage; delivery, erection and bracing of trusses and truss systems, seeANSVWII Quality Criteria, DS13•89 and SCSI Building Component
6904 Parke East Blvd.
Safety Informationavailabie from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610..
Job
Truss
Truss Type
Qty
Ply
T18335994
201*03091-TNT
03
Hip Girder
1
1
Job Reference (optional)
oulluam rinaouurce, run rice, rL J4U40 nun:.. u J — I I Gu I. rlml: 0.— s JUi cr — i e rvn i en 111—Ulee, nm. U I U i i c
ID:PftLq)XzGof3aThkEvvERV6zC114-TAd8vnzpzSZLnABOCM9bURiil9MsCa_bf4_SLAy sUL
1-4-0 4-8-0 i 15-4-0 i 18-8-0 i 22-0-0 _ 1 23-4.0
1-4-0 3-4-0 3-4-6 7-4-0 3-4-0 3-4-0 1-4-0 '
Scale = 1:39.2
Special
6x8 =
4
Special
NAILED NAILED NAILED 5x6 =
14 15 16 5
V 3x4 = NAILED 4x10 MT20HS= 3x8
ST1.5x8 STP = ST1.5x8 STP
NAILED NAILED
6x8 — Special Special 6x8 — .
23-4-0
Plate Offsets (X Y)--
[1:0-0-0 0-0-151•[4:0-4-0 0-2-21 [9:0-3-8
0-3-01 [13:0-3-8 0-3-UI
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in . (loc) I/dell Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.49
Vert(LL) -0.15 10-12 >999 360 ,
MT20 244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.59
Vert(CT) -0.37 10-12 >670 240
MT20HS 187/143
BCLL 0.0 ' :
Rep Stress Incr NO
WB 0.89
Horz(CT) 0.06 9 n/a .' n/a.
BCDL 10.0
Code FBC2017/T012014
Matrix-SH
Wind(LL) 0.12 10-12 . >999 240
Weight: 123 lb FT = 20%
LUMBER- . BRACING -
TOP CHORD 2x4 SP No.2 "Except TOP CHORD Structural wood sheathing directly applied or 3-0-5 or, purlihs.
4-5:'2x6 SP M 26 BOT CHORD- Rigid ceiling directly applied or 6-7-0 oc bracing.
BOT CHORD 2x4 SP M 31 WEBS 1 Row at midpt 4=10
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 13=1904/0-8-0,.9=1905/0-8-0
Max Horz 13=72(LC 12)
Max Uplift 13=-926(LC 8),_9=-925(LC 9)
-..
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250:(Ib) or less except when shown.:
TOP CHORD 3-4=-3124/1587; 4-14=-2871/1519, 14-15=-2871/1519, 15-16=-2871/.1.519,.
5-16=-2871/1519, 5-6=: 3130/1587
BOT CHORD 12-13=-1248/2447, 12-17=-1394/2865, 11-17=-1394/2865, 11-18=-1394/2865,
10-18=-1394/2865, 9-10=-1176/2449
WEBS 2-13=-305/214, 3-13=-2738/1334, 3=12==331/614, 4-12=0/524, 5-10=0/526, .
6-10=-332/619, 6-9=-2743/1335, 7-9==308/214
NOTES-
1) Unbalanced roof live loads have been Considered for this design.
2) Wind: ASCE 7-10; Vuit=170mph (3-second gust) Vasd=1 32mphi TCDL'=4:2psf; BCDL=5.Opsf; h=15ft; Cat. II; Exp Q. Encl., "
GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; Lumber DOL=1.66 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates.are. MT20 plates unless otherwise indicated.
5) This I -miss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any otheriive loads.
6) ' This truss. has been designed fora live, Load of.20.0psf on the bottom chord in all areas wherea rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 926 lb uplift at joint 13 and 925 lb uplift at
joint 9.
8) "NAILED" indicates 3-10d (o.148!,x3,,) or 3-12d:(0.148"x3.25") toe -nails per NDS guidlines.
9) Hanger(s):or other connection device(s) shall be provided sufficient Io supportconcentrated load(s) 266 lb down and 344 lb up at
8-0-0; and 266 lb, down and 344 lb,up at 15-4-0:on top chord, and 343 lb down and 187 lb up at. 8-0-0,, and,343 lb down and 187 lb
up at 15-3-4 on bottom Chord. The design/selectjon of such connection devices) is the responsibility of others:
10) In the LOAD CASES) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead.+ Roof Live:(balanced): Lumber Increase=1.25, Plate Increase--1.25
Walter P. Finn PE N6.22839
Uniform Loads (plf)
MiTek USA, Ing. FL Cert66.34:
Vert: 1-4=-70,"4-5=-70, 5-8=-70, 1-8=-20
8904 Parke East Blvd Tampa FL 33810
.' Concentrated Loads (Ib) '
Date:
Vert:.4=-219(B) 5==219(B) 11=-57(B) 12=-343(B) 10==343(B) 14=-138(B) 15=-138(B) 16=-138(B) 17=-57(B) 18=-57(B) ...
October 10,2019
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE 11114473 rev. 1WO312015 BEFORE USE.
Design valid for use only with MiTeke connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the. building designer must verify the applicability of design porameters.and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss.web and/or chord members only. Additional temporary and permanent bracing
Is always required for stability and to prevent.collopse with possible personal Injury and property damage. For general guidance regarding the • ... '
fabricatlon, storage, delivery, erection and bracing of trusses and truss systems, seeANSVIPII Quality CtBerW, DSB-89 and SCSI Building Component:
6904 Parke East Blvd.,
Safety Informatlonavollable from Truss Plate Institute; 218 N. Lee Street Suite 312, Alexandria, VA 22314. .. .. ...
Tampa, FL 33610. - .
Job
l russ
Truss Type
Qty
Ply
- T18335995
20103091-TNT
EA
Jack -Open
1
1
Job Reference (optional)
euiaers mrstbource, ron niece, rr_ 04`J4b
Hun: 6.24U S Feb 11 2u1 u vnnt: 6.24u s Jul 21 2u19 mi I ex Nausines, inc.
I nU UC11 U 1 U:1Z:bn ZU1 `J rage 1
ID:PftLgjXzGof3aThkEwERV6zC114-TAd8vnzpzSZLnABOCM9bURim09VSCnpbf4_SLAyUsUL
-1-0.0 1-4-0
ST1.5x8 STP =
2x4 111-0-0 1-4-0
1-0-0 0-4-0
Scale = 1:10.3
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) Well Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.23
Vert(LL) 0.00
7 >999. 360
MT20 . 244/190
TCDL 15,0
Lumber DOL 1.25
BC 0.04
Vert(CT) , 0.00
7 >999 240
BCLL 0.0 -
Rep Stress lncr YES
WEI0.01
Horz(CT): -0.00
4 n/a n/a -
BCDL 10.0 .
Code FBC2017/TP12014
Matrix-P
Wind(LL) 0.00
7 >999 240 -
Weight: 8:lb FT = 20%
LUMBER-
BRACING -
TOR CHORD 2x4 SPNo.2
TOP CHORD
Structural wood sheathing directly applied or 1-4-0 oc purlins; except
BOT CHORD' 2x4 SP No.2
end verticals.
WEBS 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 7=172/0-8-0, 4=15/Mechaniical, 5=-1/Mechanical
Max Horz 7=52(LC 8)
Max Uplift 7=-85(LC 8), 4=726(LC.12), 5=-6(LC 12)
Max_Grav 7=172(LC 1), 4=15(LC 1), 5=14(LC 3)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-7==159/252
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; Cat. II; Exp C; Encl.,
GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and -fight exposed ;C-C for members and forces & MWFRS,
for reactions shown; _Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) . This truss has been designed for a live load of 20.Opsf on the:bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any othermembers.
4) Refer to girder(s) for truss to truss connections.;
5 Provide mechanical connection b others of truss to bearin late Capable of withstanding 85 lb uplift 'at joint 7,.26. lb uplift at joint 4'
(Y ) 9P P 9.1 P 1
and 6 lb uplift at joint 5.. .
LOAD CASE(S) Standard
Walter P. Finn PE No.22839 "
MiTek USA, Inc. FL Cart 66U.
8904 Parke East Blvd. Tampa 171.038110
Date:
"October 10,2019
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCEPAGE MI17473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verity the applicability of design parameters -and properly Incorporate this design Into the overall
building deslgn. Bracing Indicated is to buckling of individual truss web and/or chord members only.. Additional temporary and permanent bracing
MOW
prevent
Is always required for stability and to prevent.collopse with possible personal Injury and property damage. For general guidance regarding the -
....
fabrication; storage; delivery, erection and bracing of trusses and truss systems, seeANSVTPif Quality Crfteda, DSB-89 and BCSI Buldlnp Component:
6904 Parke East Blvd. -
Sofoty Infonnatlonavallabie from Truss Plate Instltute; 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610.
Job
Truss
Truss Type
Qty�Ply-
211103091-TNT
E.15
'
Jack -Open
6
1
T16335996
Job Reference (optional)
ounuers t-Irs[Source, t-on rlece, rL-94s4b
. 1-4-0
Hun: t3.24U S t-et) 11 zUi u vnnt: tr.24U S JUI 2/ 2U1IJ MI I eK Incustnes, Inc. I nu uct 1 U 1 U:1z:b/ zu1 a rage 1
I D:PftLgjXzGof3aThkEwERV6zC114-yMBW 77_SkmhCPKmDm3ggl fEsDYnTxCW kukjOtdyUsUK
6-0.0
4-8.0
.Scale = 1:20.9
5
4:.
ST1.5x8 STP =
3x12 MT20HS I I
1-0.9
6-0-0
1-0-0
5-0-0
Plate Offsets (X Y)--
[1.0-0-0 0-0-15] [5.0-2-7 Edge]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
. (loc)'
. Vdefl
Ud
_PLATES
GRIP
TCLL 20.0
Plate Grip, DOL 1.25
TIC ..0.5.5
Vert(LL)
-0.02
4-5
>999 .360
MT20
244/190
TCDL :15.0
Lumber'DOL 1.25
C . 0.31
Vert(CT)
-0.04
4-5
>999
240 _
MT20HS
187/143
BCLL 0.0 '
Rep Stress Incr YES
WB 0.17.
Horz(CT)
. -0.04
3
n/a
n/a
BCDL lob
Code FBC2017/TP12014
Matrix-P
Wind(LL)
0.03
4-5
>999
240
Weight: 2b lb
FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood.sheathing directly applied or 6=0-0 oc purlins.
BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied'or 10-0-0 oc bracing.
WEBS:. ' 2x4 SP No.3
REACTIONS. (lb/size) 3=141/Mechanical, 4=49/Mechanical, 5=345/0-8-0
Max Horz 5=150(LC 12)
•
Max Uplift 3=-122(LG 12), 5=-11.2(1LC 8)
Max:Grav 3=141(LC 1), 4=83(LC,3), 5=345(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown..
TOP CHORD 1-2=-367/1,46 .
BOT CHORD 1-5=-114/317
WEBS 2-5=-315/567
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; Cat. II; Exp C; Encl.,
GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members :and forces &:MWFRS
for reactions 'shown; Lumber DOL=1.60: plate grip DOL=1.60
2) All plates are MT20 plates unless otherwise indicated.
3) This truss'hag been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 122 lb uplift at joint 3 and 112 lb uplift at
joint 5. .... .
LOAD CASES) Standard
WARNING -Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
_.
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parometers.and properly Incorporate This design Into the overall
building design. Bracing Indicated Is to buckling of individual truss web and/or chard members only.. Additional temporary and permanent bracing
M
prevent
Is always required for stability and to prevent. collapse with possible personal injury and property damage. For general guidance regarding the: ' ...
iTek`
fabrication: storage, delivery, erection and bracing of trusses and truss systems, seeANSVIPl1 Quality CrBeda, DSB-89 and BCSI Bugding Component:
6904 Parke East Blvd.,
Safety Informatlonavailoble from Truss Plate Institute; 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, K 33610. . ,
Job
Truss
Truss Type
Q ty
ply
T18335997
20103091-TNT
EJ7
Jack -Open
35
1
Job Reference (optional)
ounuers risrocurce, ron rlece, rL J4s4e nun: u.44u s reo l l zUl=! rnm: tl.z4U s JUI z/ zUly mi I eK mausmes, mc. 1 nu VCr 1u 1u:1 e:D/ zul `J rage 1
I D:PftLgiXzGof3aThkEwERV6zC114-yMBW 77_SkmhCPKmDm3ggl fEngYhNxA5kukjOtdyUsUK
1-4-0 8-0-0
1-4-0 6-8-0
1
ST1.5x8 STP =
3x12'MT20HS II
8-0.0
7-0.0
cm
0
m
Scale: 1/2°=1'
Plate Offsets (X Y)-- f1:0-0-0 0-0-151 15:0-2-7 Edgel .
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
. (loc) I/defl Ud
PLATES
GRIP
TCLL 20;0
Plate Grip, DOL 1.25
TC 0.89
Vert(LL) -0.08
4-5 >999 360
MT20
244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.70
Vert(CT) -9.19
4-5 >414 240 _
MT20HS "
187/143
BCLL 0.0
Rep Stress Incr YES
WB 0.26
Horz(CT) -0.11
3 n/a We
BCDL 10.0
Code FBC2017fTP12014
Matrix-SH
Wind(LL) 0.15
A-5 >533 240
Weight: 26lb
FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.i
TOP CHORD
Structural wood.sheathing directly applied or 2-2-0
oc puffins.
BOT CHORD 2x4 SP No.2
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 3=208/Mechanical, 4=77/Mechanical, 5=429/0-8-0
Max Harz 5=196(LC 12) .. .
Max Uplift 3=-173(LC 12), 5=-126(LC 12)
Max Grav 3=208(LC 1), 4=1.23(LC 3), 5=429(LC 1)--
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250.(Ib) or less except when shown..
TOP CHORD 1-2=-548/213
BOT CHORD . 1,-5=-139/387
WEBS 2-5=-462/871
NOTES-
1) Wind: ASCE 7-10; Vult=1.70mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; Cat. II; Exp C; Encl.,
GCpi=0.18; MWFRS. (envelope) and C-C Exterior(2) 0-0-0 to 6-0-0, Interior(1) 6-0-0 to 7-11-4 zone; cantilever left and right exposed
;C-C. for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) All plates are MT20 plates unless otherwise indicated.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2=0-0 wide
will fit between the bottom chard and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of. withstanding 173115 uplift at joint 3 and 126 lb uplift at
joint 5.
LOAD CASE(S) Standard
Waller P. Finn PE No.22839
.. MiTek USA, Inc. FL Cart 66U.
6904 Parke East Blvd. Tampa FL 33610
Date:
October 10,2019
. WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MrTEK REFERANCE PAGE MII-7473 rev. 10103QOIS BEFORE USE.
_
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not
�� -
a.truss system. Before use, the building designer must verify the applicability of design parameters.and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss.web and/or chord members only.. Additional temporary and permanent bracing
MiTek` '
Is always required for stability and to prevent.collapse with possible personal Injury and property damage. For general guidance regarding the:
.
fabrication; storage; delivery, erection and bracing of trusses and truss systems, seeANSVTPII Quality CIfteda, DSB-89, and BCSI Building Component.
6904 Parke East Blvd.,
Safety Informatlanavoilable from Truss Plate Institute; 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610• . .
Job
Truss
Truss Type
Qty
Ply
T18335998
20103091-TNT
EJ21
JACK -OPEN
1
1
-
Job Reference (optional)
B.ild s nrswuurce, Pon Piece, FL 34945 nun: e.zvu s Feb i i zui s rnnr. ezau s uw a 2019 Mi i ex industries, Inc. i nu 0ci t o i u:12:oi zut a Pagel
I D:PftLgjXzGof3aThkEwERV6zCl l 4-yMBW 77_SkmhCPKmDm3ggi fEyAYg6xDOkukjOtdyUsUK
-0-11-8 0 1 1 1-10.8 .
0-11-8 0-1-1 1-9-7
s_nn R _ Scale = 1:18.2
0
9
0
m
6 ..
ADEQUATE 5 4
SUPPORT 2x4 II 3x4 =
REQUIRED. 0-1-1
-io-e
1s7
010
Plate Offsets (X Y)-- [4•Edge 0-1-81
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL. in
. (16c). I/deft Ud
PLATES GRIP
TCLL 20,0
Plate Grip DOL -
1.25
TC 0.17
Vert(LL) -0.00
5 >999 360.
MT20 244/190
TCDL 15.0
Lumber DOL
1.25
BC - 0.08
Vert(CT) : -0.00
4-5 >999 240
BCLL 0.0
Rep Stress Incr
..YES
WB 0.07
Horz(CT) . -0.00
3 n/a n/a .
BCDL 10.0
Code FBC2017/TP12014
Matrix-P
Wind(LL) 0.00
5 >999 240
Weight: 14lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
'TOP CHORD
Structural wood sheathing directly applied or 1-10-8;o6 purlins.
BOT CHORD 2x4 SP No.2
BOT CHORD "
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 3=27/Mechanical, 6=169/Mechanical, 4=39/Mechanical
Max Horz6=61(LC 8). .
Max Uplift 3= 28(LC 12); 6=-31(LC 8), 4=-72(LC 8)
Max Grav 3=27(LC 1), 6=169(LC 1), 4=46(LC 3)
FORCES. (lb) - Max. Comp,/Max. Ten. - All forces 25b (lb) or less except when shown.:
NOTES-
1) Wind: ASCE 7-10; Vuit=170mph (3=second gust) Vasd=132mph; TCDL=4,2psf; BCDL=5.Opsf; h=15ft; Cat. 11; Exp C; Encl.,
GCpi=0.18; MWFRS (envelope) and C-C•Extedor(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS;
for reactions shown;:Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-070 wide
will fit between the bottom chord and any other -members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection ,(by others) of truss to bearing plate capable of withstanding 28 lb uplift at joint 3, 31 lb uplift at joint 6
and 72 lb uplift at joint 4. -
LOAD CASE(S) Standard
A WARNING -Verify design parameters and READ NOTES ON. THIS AND INCLUDED MITEK REFERANCE PAGE MII.7473 rev. 1010=015 BEFORE USE.
Design valid for use only with Mrrek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, The, building designer must verify the applicability of design porameters.and properly Incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only.. Additional temporary and permanent bracing
MITBk-
is always required for stability and to prevent, collapse with possible personal Injury and property damage. For general guidance regarding the:
fabrication; storage, delivery, erection and bracing of trusses and truss systems, seeANSVTPII QualitItyy Criteria, DSB-89 and BCSI Bugdtng Component:
6904 Parke East Blvd..
Safety Infonnatlanovailoble from Truss Plate Institute; 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33010 .
Job
Truss
Qty
Ply
T18335999
20103091-TNT
EJ22
JACK -OPEN
1
1
Job Reference (optional)
Dormers r r touuroe, ron rieoe, rr. 04e4a
mun: u.z4u s "D 11 Zulu vnnt: b.z4u s JUI Zr Zulu mi i eK Inaustnes,, Inc. 1 nu uct l u l un z:br Zulu rage l
I D:PftLgjXzGof3aThkEwERV6zC114-yMBW 77_SkmhCPKmDm3gg1 fEwuYppxEBkukjOtdyUsUK
1-10-8
1-10-8
5.00 12 Scale = 1:18.2
2:
ADEQUATE
SUPPORT
REQUIRED. 4 3
3x4 I
1 10 8
1108
m
0
M
LOADING (psf)
TCLL 20.0
TCDL 15.0
BCLL 0.0 '
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC201.7/TPI2014
CSI.
TC 0.31
BC 0.16
WB' 0.00
Matrix-R
DEFL. in (loc) I/dell Ud
Vert(LL) 0.00 4 >999 240
Vert(CT) . -0.0.0 3-4 >999 : 240;
Horz(CT) -0.03 2 n/a n/a
PLATES GRIP
MT20 : 244/190
Weight: 9.Ib FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 1-10-8 oc purlins,
BOT CHORD 2x4 SP No.2 except end verticals.
WEBS 2x4"SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing." "
REACTIONS. (lb/size) 4=77/Mechanical, 2=58/Mechanical, 3 19/Mechanical'
Max Horz 4=40(LC.12)
Max Uplift 2= 69(LC 12), 3=-18(LC 12)
Max.Grav 4=77(LC 1), 2=58(LC 1), 3=34(LC 3)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.-
NOTES-
1) Wind: ASCE 7-10; Vult=170Mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=5.0psf; h=15ft; Cat.:ll; Exp C; Encl.,
GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS
for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed fora 10.0 psf bottom chord.live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0=0 wide
will fit between the bottom chord and any other members.
4) Refer.to girder(s) for truss to truss connections.
5) Provide Mechanical connection (by others) of truss to bearing plate Capable of. withstanding 69 lb uplift at joint 2 and 18 Ib uplift at
joint 3. .....
LOAD CASE(S) Standard
Walter P. Finn PE No.22839'
MiTek USA, Inc. FL Cert6634:
69H Parke East Blvd. Tampa FL 33610
n
Date:-','
October 10,2019
® WARNING - Verify deslgn parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGEMll-7473 rev. 1010312015 BEFORE USE,
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the. building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing,
MiTek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the . .
fabrication, storage; delivery, erection and bracing -of trusses and truss systems, seeANSVtPII QuaBByy Cdtoda, DSB-89 and BCSI Building Component:
6904 Parke East Blvd..
Safety InformaHonovailoble from Truss Plate Institute; 218 N. Lee Street, Suite 312, Alexandria, VA 22314. ... . .: ..... ..
Tampa, FL 33610. .
Job
Truss
Truss Type
ty
Ply
T18336000
20103091-TNT
EJ71
Jack -Partial
3
1
Job Reference (optional)
ouaaers rnstoaurce, Fort Piece,. FL 34945 Run: 9.24U s Feb 11 2019 Print: u.240 s JUI'L/ 2019 MI Tek Industnes, Inc. Thu Oct 1 U l U:12:09 2019 rage i
ID:PftLgjXzGof3aThkEwERV6zC114-QYkuKT_4V4p3OTKPJnB3Zsnw6yOrgftt6OTZP3yUsUJ
it
=4.0 3-10-0 8-0-0
1-4.0 2.6-0 4-2-0
Scale: 1/T=1'
7 2x4 11
ST1.5xB STP =
3x6 'I I
1-0.0 4• 3-10-0
1-0-0 4- 2-6.0
-0
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (Ioc).,., Udefl Lid
PLATES GRIP
TCLL 20:0
Plate Grip DOL 125
TIC . 0.92
Vert(LL) -0.09 4-5 '>851 360
MT20 2.44/190
TCDL 15.0
LumberDOL1.25
BC 0.68
Vert(CT) -0.23 4-5 >347 240 .
BCLL 0.0 '
Rep Stress Incr YES
WB. 0.16
Horz(CT) 0.06 3 n/a n/a
BCDL 10.0
Code FBC2017/TP12014 "
Matrix-SH
Wind(LL) 0.17 4-5, >468 240
Weight: 36lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP, CHORD Structural wood. Sheathing directly applied.
BOT CHORD 2x4 SP No.2'Except. BOT CHORD Rigid ceiling directly applied or
10-0-0 oc bracing, Except:
_
. 5-6: 2x4 SP No.3 8-10-1 oc bracing: 6-7.
WEBS 2x4 SP No.3
REACTIONS. .(Ib/size) 3=197/Mechanical, 4=96/Mechanical, 7=468/0r8-0
Max Harz 7=196(LC 12)
Max Uplift 3=-154(LC_ 12), 4=-12(LC 12), 7=-106(LC 12)
Max Grav 3=197(LC 1), 4=141(LC 3), 7=468(LC 1)
FORCES. (lb) - Max..Comp./Max. Ten. - All forces 250 (lb) or less except when shown.. .
BOT CHORD . 6r7= 437/299, 2-5=-299/441
WEBS 2-7=-429/544
NOTES-
1) Wind: ASCE 7-10; Vult=170mph-(3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; Cat. II; Exp C; Encl.,,
GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) 0-0-0 to 6-0-0, Interior(1) 6-0-0 to 7-11-4: zone; cantilever left and right exposed
;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcul`rent with any other live loads..
3) ' This truss has been designed for live load of20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members:
4) Refer to girder(s) for. truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 154.Ib uplift at joint 3, 12 Ib uplift at joint 4
and 106 Ib uplift at joint 7.
LOAD CASE(S) Standard .
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cert 663,4
6904 Parke East Blvd. Tampa FL:33610
Date: .
O tober 10,2019
C
... ..
& WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MX7473 rev. 1W03/2015 BEFORE USE.
Design valid for use only with Mirek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
�
a truss system. Before use, the building designer must verity the applicability of design parameters. and properly Incorporate this design Into the overall
building design. Bracing indicated is to buckling of individual truss.web and/or chord members only.. Additional temporary and permanent bracing
MiTeW
prevent
Is always required for stability and to prevent. collapse with possible personal Injury and property damage. For general guidance regarding the: ...
.
6904 Parke East Blvd.
fabrication; storage; delivery, erection and bracing of trusses and truss systems, seeANSVIPII Qualify Cftft, DSB-69 and BCSI Building Carnpionont:
Tampa, FL 33610..
Safety Informationavallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. .... .. ..... .
Job
Truss
Truss Type
City
Ply
T18336001
20103091-TNT
EJ72
Jack•Partial
3
1
Job Reference (optional)
eumers rlrstsource, t-ort t•lece, FL 34945
Hun: 5.24U S hen 11 zg19 YMt: 6.24U S Jul ZI ZU19 MI I eK Inaustnes, Inc. I nu uct lu 1un 2:bb zu19 Ya e 1
ID:PftLgiXzGof3aThkEwERV6zC114-QYkuKT_4V4p3OTKPJnB3Zsn4iy10gfpt6OTZP3y sUJ
11 6-1.8 8-0.0
1-4-0 4-9.8 1-10-8
ST1.5x8 STP =
3x12 MT20HS I
1-0-0 4- 6-1-8 8-0-0
1-0.0 4- 4.9-8 1.10-B
Scale: 1/2"=1'
m
0
N
m
Lh
m
O
0'
Plate Offsets (X Y)-- [.1:0-0-0 0-0-151; [5:Edge 0-1-81 [8:072-7 Edgel
LOADING (psf)
SPACING- 2-0-0
CS].
DEFL. in
(loc) I/defl Ud
PLATES
GRIP
TCLL 20:0
Plate Grip DOL 1.25
TC 0.3.1
Vert(LL) -0.01
7-8 >999 : 360
MT20-
244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.61
Vert(CT) -0.02
7-8 >999 240
MT20HS
187/143 -
BCLL 0.0
Rep Stress Incr YES
WB 0.17
Horz(CT) -0.03
5 n/a n/a .
BCDL 10.0
Code FBC2017/fP12014
Matrix-SH
Wind(LL) 0.02
6 .>999 240
" Weight: 33lb
FT=20% ..
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP_ CHORD
Structural wood.sheathing directly applied or 6-0-09c
pudins.
BOT CHORD 2x4 SP No.2 "Except
BOT CHORD
Rigid ceiling directly applied or 9-7-10 oc bracing.
" 3-7:'2x4 SP No.3
WEBS 2x4 SP No.3
REACTIONS.. .(lb/size) 4=38/Mechanical, 5=246/Mechanical, 8=432/078-0
_1
.
Max.Horz 8=196(LC 12):
Max Uplift 4=-18(LC 12), 5=-150(LC 12), 8=-127(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250.(lb) or less except when shown.
TOP CHORD 2-3=-265/1.03
BOT CHORD• 7-8=-278/223, 5-6=-347/283
WEBS 2-8=-336/55713-5= 370/454 .
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; Cat. II; Exp C; Encl.,
GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) 0.0-0 to 5-11-12, Interior(1) 5-11-12 to.7-11-4 zone; cantilever left and right
exposed ;C-C for members and forces.& MWFRS for reactions shown;: Lumber DOL=1.60 plate:grip, DOL=1.60
2) All plates are MT20 plates unless otherwise indicated.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2=0-0 wide
will fit between the bottom chord and any other members.
5) Refer, to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of,withstanding 18 lb uplift at joint 4, 150 lb uplift at.joint 5
and 127 Ip ,uplift at joint 8.
LOAD CASE(S) Standard
Walter P. Finn PE N6.22839
...... '.:
MiTek USA, Inc. FL Cart 034
69D4 Parke East Blvd. Tampa FL 33610
e
Date:
Octobe r 10,2019
WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGEM11.7473 rev. 1010312015 BEFORE USE,
`
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parometers.and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to buckling of Individual truss web and/or chord members only., Additional temporary and permanent bracing
MITek"
prevent
is alwayssequired for stability and to prevent, collapse with possible personal Injury and property damage. For general guidance regarding the. .
.
fabrication; storage; delivery, erection and bracing of trusses and truss systems, seeANSVTPII Qualify Cdfeda, DSB-89 and BCSI Building Component
6904 Parke East Blvd.,
Safety Infotmafbnovallable from Truss Plate Institute: 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610 . .
Job
russ
Truss Type
ty
y
T18336002
20103091-TNT
G1
Hip Girder
1
1
Job Reference (optional)
oumers mrsiaeurce, ror[ riece,, rL. avavo nun. o.wu s reu i i cu i a Hurt; o.«v s �w c, cc is rvn i en muusurcs,,um. rays
ID:PftLgiXzGof3aThkEwERV6zC114-ullGXp?iGNxwedvbtU]I64K7UMIBP221 L2C7yVyUsUI
1-4-0 -4 60 , 11-1-0 16-2-0 , 20-10-0 22-2-0
1-4-0 4-8-0 5.1-0 5-1-0 4-8-0 1-40
Scale = 1:37.0
5.00 F12
Special
5x8 =
NAILED
3 13
NAILED
NAILED 2x4 II NAILED
14 4 15 16
Special
5xB
5
2x4 11 ryni�ou rvru�cv .5x8 = 2x4 II
ST1.5x8 STP = ST1.5x8 STP =
3x12 MT20HS II Special NAILED Special 3x12 MT20HS II
1-0-0' -a- 6-0-0
11-1-0
16-2.0 20-10-0
'21.2022-2-0
1-0.0 4 4-8-0
5-1-0
5-1-0 4-8-0
-41-0-0
Plate Offsets (X 1)-- [1.0-0-0 0-0-15] [3.0-5-12 0-2-8] [5:0-5-12
0-2-8] [7:0=0-0 0-0-15] [8:0-2-7 Edge]
[10:0-4-0 0-3-01 [12:0-2-7 Edgel
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) Udefl Ud
PLATES
GRIP
TCLL 20:O
Plate Grip, DOL 1.25
TC 0.82
Vert(LL)
0.36 9-10 >647 240
MT20
244/190
.:
TCDL 15.0
Lumber DOL 1.25
BC 0.93
Vert(CT)
-0.47 10-11 >495 240
MT20HS
187/143
BCLL 6.0 '
Rep Stress Incr NO
WB 0.42
HOrz(CT)
0.04 8 n/a n/a
BCDL 10.6
Code FBC2017/TP12014 .
Matrix-SH
Weight: 96 lb
FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 31 'Except
TOP. CHORD Structural wood sheathing directly applied or 2-6-7
oc pudins.
3-5:-2x4 SP No.2
BOT CHORD Rigid ceiling directly applied or 7-3-1 oc bracing.
BOT CHORD 2x4 SP M 31
WEBS 2x4 SP.No.3
REACTIONS. .(Ib/size) 12=1437/0-8-0,.8m1437/0-8-0
Max.Horz 12=56(LC 8) : -
Max;Uplift 12= 763(LC 4), 8- 763(LC 5)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP. CHORD 1-2=-1783/962, 2-3=-2038/1144, 3-.13=-2710/1603, 13-14=-2710/.1603,.4-14=-2709/1603,
4-15=-2709/1603, 15-16=-2710/1603, 5-16=-2710/1603, 5-6=-2038/1144, 6-7=-1783/962
BOT CHORD 1-12=-947/1765, 11=12=-949/1765, 11-17=-940/1760, 17-18— 940/1760, 10-18=-940/1760,
10=19= 937/1760, 19=20=-937/1760, 9-20=-937/1760, 8-9= 947/1765, 7-8=-947/1765
WEBS 3-10=-639/1106, 4-10=-669/522, 5-10— 639/1106, 2-12=-638/428,'6-8=-638/428
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4:2psf; BCDL=5.Opsf; h=15ft; Cat. 11; Exp C; Encl.,
GCpi=0.18; MWFRS (envelope); cantilever left-andright exposed; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding:. .
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live lead nonconcurrent with any other. live loads.
6) ' This truss has been designed for live load of.20.Opsf on the bottom chord in all areas where a, rectangle 3-6-0 tall by 2-0-0 wide
will fit -between the bottom chord and any other members.
7) Provide mechanical connection .(by others) of truss to bearing plate capable of withstanding 763'lb uplift at joint 12 and 763 lb uplift at
joint 8.
8) "NAILED" indicates 3-10d (0.148"x3") or 3-12d (0.148"x3.25") toe -nails per NDS guidlines.
9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 217-lb down and 293 lb up. at
6-0-0; and 217lb down and 293 lb up"at' 16-2-0 on top chord, and 104,lb down and 58 lb up at 64-0, and 104lb down and 58 lb up
at 16-1-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others:
10) In the LOAD CASE,(S) section; loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard : . . .
1) Dead:+ -Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (pif)
Vert: 1-3=-70, 3-5=-70, 5-7=-70; T-7=-20
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cart 6634,
6904 Parke East Blvd. Tampa FL 33610
Date:
October 10,2019
WARNING -Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII.7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MRek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
a.truss system. Before use, The. building designer must verify the appllcgbllity of design parameters. and properly Incorporate this design into the overall
building design. Bracing Indicated Is to buckling of individual truss and/or chord members only.. Additional temporary and permanent bracing
MITBK•
prevent web
Is always required for stability and to prevent.collopse with possible personal Injury and property damage. For general guidance regarding the: - ... '
.
6904 Parke East Blvd.,
fabrication, storage; delivery, erection and bracing of trusses and truss systems, seeANSVMII Quality Criteria, DSB49 and BCSI Building Component:
'
Tampa, FL 33610..
Safety Informatlonovailable from Truss Plate Institute; 218 N. Lee Street, Suite 312. Alexandria, VA 22314. . ... . . .....
.
Job
Truss
russ ype
ty
y
T16336002
20103091-TNT
G1
Hip Girder
1
1
Job Reference (optional)
bullaers mrS[Jource, tort meCe,, rL.a4945 Hun: e.24u s 1-ea 11 Zu1.4 runt: u.z4u s Jul z/ 2u1 a mi I eK Inaustnes,inc. I nu uci l u i u:lz:oe Zulu rage z
ID:PftLgiXzGof3aThkEwERV6zC114-u11GXp7iGNxwedvbtUj164K7UMIBP221 L2C7yVyUsUI
LOAD CASE(S) - Standard
Concentrated toads (Ib)
Vert: 3=-170(F) 5=170(F) 11=-69(F) 9=-69(F) 13= 71(F) 14=-71(F) 15=-71(F) 16=-71(F) 17= 29(F) 18=-29(F) 19=-29(F) 20=-29(F)
- A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MfrEK REFERANCEPAGE'MIF7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
a.truss system. Before use, the building designer must verify the applicability of design parometers.and properly Incorporate this design Into the overall
bullding design. Bracing indicated is to buckling Individual truss,web and/or chord members only. Additional temporary and permanent bracing
MiTek..
prevent of
Is always required for stability and to prevent. collapse with possible personal Injury and property damage. For general guidance regarding the:,
fabrication;. storage; delivery, erection and bracing of trusses and truss systems, seeANSVFPII Quality CdlOrla, DSB-89 and BCSI Budding Component:
6904 Parke East Blvd..
Safety Infonnationovailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610..
Job
Truss
Truss Type
Qty
Ply
T18336003
20103091-TNT
HJ5
Diagonal Hip Girder
2
1
Job Reference (optional)
eunciers mrstbource, port Nlece, I-L 34845 Hun: 5.24U S Feb 11 2U18 vnnt: 6.24U S JUI 27 ZU1 U MI I eK Inouslnes, Inc. I nu Uct 1 U 1 un Z:bu 2Ul a Page 1
ID:PftLlXzGof3aThkEwERV6zC1147ullGXp?iGNxwedvbtUj164K7cMP1 P701 L2C7yVyUsUI
-4 4-2-6 8-5-1
1-11-190 4 2-4-2 4-2-11
Scale=1:19.9
5 4
2x4 11
1-4-10
1-4-10
LOADING (psf)
SPACING-
2-0-0.
CSI.
DEFL.
in
(Ioc)
I/defl
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TIC 0.81
Vert(LL)
0.13
4-5
>580
240
MT20 244/190
TCDL 15.0
Lumber DOL
1.25
BC 0.49
Vert(CT)
. -0.117
4-5
>471
240..
BCLL 0.0
Rep Stress Incr
NO
WB 0.10
Horz(CT);
-0.08
3
n/a
.n/a .
BCDL 10.0
Code FBC2017/TP12014
Matrix-SH
Weight: 26 Ib FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP No.2 BOT. CHORD Rigid ceiling directly applied or 10-0-0 oc bracing..
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 3=198/Mechanical, 4=69/Mechanical, 5=482/0-11-5
Max Hori 5=150(LC 4)
Max Uplift 3=-156(LC 8), 4= 1 O(LC 8), 5= 306(LC 4)
Max Grav 3=198(LC 1),:4=118(LC 3), 5=482(LC 1)
FORCES. (Ib) -:Max. Comp./Max, Ten. -All forces 250 (lb) or less except when shown.
WEBS 2-5=-449/349
NOTES- .
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4,2psf; BCDL=5.Opsf; h=15ft; Cat. II; Exp C; Encl.,
GCpi=0.18; MW FRS (envelope); cantilever left and right exposed Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members. .
4) Refer: to girders) for truss to truss Connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 156 lb uplift at joint 3, 10 lb uplift at joint 4
and 306 lb uplift at joint 5. `
6) "NAILED" indicates 3=10d (0.148"x3") or 2-12d (0.148"x3.25') toe -nails per NDS guidlines.
7) In the LOAD CASE(S) section,.loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live. (balanced): Lumber Increase=1.25, Plate Increase=125;
Uniform Loads (plf)
Vert: 1-3=-70, 1-4=-20
Concentrated Loads (Ib)
Vert: 9=3(1`=2, M) .. ... .
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cert 663.4
East Blvd Tampa
6994 Parke E FL 33610.
.. Date:
October 10,2019
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED M/TEK REFERANCE PAGE'MIF7473 rev, 1010312015 BEFORE USE.
Design valid for use only with MITeke connectors. This deslgn Is based only upon porameters'shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parometers.and properly Incorporate this design Into the overall
- building design. Bracing indicated is to buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
Welk'
prevent
Is always required for stability and to prevent. collapse with possible personal Injury and property damage. For general guidance regarding the: ... '
fabrication, storage; delivery, erection and bracing of trusses and truss systems, seeANSV?II CualNy Criteria, DSB-89 and BCSI Building Component:
6904 Parke East Blvd.,
Salety Infonnatlonavailoble from Truss Plate Institute: 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610.. . .
Job
I russ
Truss Type
City
Fly
T18336004
20103091-TNT
HJ7
Diagonal Hip Girder
4
1
Job Reference (optional)
aulcers mrstJource, r•ort Mace, rL a4s4b
1-10-4
1-10-4
Hun: d.Z4u s veD 11 ZUl `J rnnc d.Z4U s JUI Z/ Zul a MI I eK ircustnes, inc. I nu uct 1 u l u:1 Z:be ZUl d ra e 1
ID:PftLgXzGof3aThkEwERV6zC114-uIIGXp?iGNxwedvbtUjl64K96MP?P221L2C7yVy sU1
6-0-0 11-3-0
4-1-12 5-3-0
2x4 II NAILED NAILED NAILED
NAILED
1130
5-3-0
0
0
M
Scale = 1:23.7
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
Well
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.65
Vert(LL)
-0.04
. 6-7
.>999
360
MT20 244/190
TCDL 15:0
Lumber DOL :
1.25
BC . 0.50
Vert(CT)
-0.08
6-7
>999
240; ,
BCLL '0.0
Rep Stress Incr
NO
WB 0.42
Horz(CT)
-0.01
4
n/a
-n/a
BCDL 10.0
Code FBC201.7/TPI2014
Matrix-SH
Wind(LL)
0.03
6-7
>999
240
Weight: 51 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing:
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 4=180/Mechanical, 8=636/0-11-5, 6=314/Mechanical
Max Holz 8=196(LC 8)
Max Uplift 4=-151(LC
FORCES. .(Ib) -Max. Comp./Max. Ten.:_ All forces 250 (lb) or less except when shown.
TOP CHORD 2-9— 704/376, 9-10= 630/372, 3=10= 622/356 "
BOT CHORD 7-14=-465/647,.6-14=465/647
WEBS 2-8=-557/310, 2-7=-368/744, 3-6=-694/499
NOTES-
1) Wind: ASCE 7-10; Vuit=170mph (3=second gust) Vasd=132mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft;.Cat. ll; Exp C; Encl.,
GCpi=0.18; MWFRS (envelope); cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) " This truss has been designed for a live load of 20.Opsf on.the;bottom chord in all areas where a rectangle 3-6.0 tall by 2.0-0 wide
will fit between the bottom chord and any othermembers.
4) Refer to girder(s) for truss to truss connections.'
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 151 Ib uplift at joint 4, 392 lb uplift at joint
8 and 170 lb uplift at joint 6:
6) "NAILED" indicates 3-10d (0.148"x3") or 2-12d (0.148"x3.25") toe -nails per NDS gutdlines.
7) In the LOAD .CASE(S) section, loads applied to the face of the truss are noted as front(F) or back (B).
LOAD CASE(S). Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25'
Uniform Loads (plf)
Vert: 1-4=-70, 1-5=-20
Concentrated Loads (lb)
Vert: 11=-84(F=-42, B=-42) 1:3=3(F=2, B=2) 14— 41(F=-21,.B=-21)
i
Walter P. Finn PE N6.22839
MiTek USA, Inc. FL Cert6634,
.6904 Parke East Blvd. Tampa FL 33610.
Date: -
October 10,2019'
WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MfrEK REFERANCE PAGE M11-7473 rev. 10/03/2015 BEFORE USE.��
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parometers.and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only.. Additional temporary and permanent bracing
MITBk•
Is always.required for stability and to prevent, collapse with possible personal Injury and property damage. For general guidance regarding the : ...
fabrication; storage; delivery, erection and bracing of trusses and truss systems, seeANSVMII Quality Cdtoda, DSB49 and BCSI Building Component:
6904 Parke East Blvd,
Safety Infomlatlonavollable from Truss Plate Institute; 218 N. Lee Street, Suite 312, Alexandria, VA 22314. ....
Tampa, FL 33610• .
Job
I russ
Truss Type
Qty
Ply
T18336005
201*03091-TNT
HJ71
Diagonal Hip Girder
1
1
Job Reference (optional)
ouuaers nrslaource, ton rlece,, r�.a454a
1-10-,
s
2x4 II NAILED -
Hun: 6.44V 5 reD 1 I zu I U rrmC 0.44U 5 JUI 4/ 4U IV Nil I UK IDUU511IG5,, Inu. I IIu V gt iv I U] I J:UU N I v ruye I
ID:PftLgiXzGof3aThkEwERV6zC114-Mxse190K1h3nGnUoRCEXeHsRKmhkBYlAaiygUyyUsUH
B-3-10 11-3-0
-6 2-112-11-6
.Scale = 1:23.8
1-4-10 1-10 5-4-5 8.3-10 11-3-0
1-4-10 5-1 3.6-1 2-11-6 2-11-6
LOADING (psf) SPACING- 2-0-0.. CSI. DEFL. in (loc): I/defl Ud ... PLATES GRIP
TCLL 20.0 Plate Grip DOL 1.25., TC 0.24 Vert(LL) 0.04 8-9 >999. 240 MT20 244/190
TCDL 15.0 Lumber DOL 1.25 BG 0.72 Vert(CT) -0.06 8-9 5999 240:
BCLL 0.0 ' Rep Stress Incr NO WBE 0.25 Horz(CT) 0.03 7 n/a ,n/a
BCDL 10.0 . Code FBC2017fTP12014 Matrix-SH . Weight: 54 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puriins.
BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 5=80/Mechanical, 11=657/0-11-5; 7=438/Mechanical
Max Harz 11=196(LC 4)
Max Uplift 5= 59(LC 4), 11=-357(LC 4), 7=-205(LC 8)
FORCES.' .(Ib) -; Max. Camp./Max. Ten. All forces 250 (lb) or less except, when shown.
TOP. CHORD 2-12=-647/264, 3-12=604/259, 3=13=-641/266,_4-13=-613/256
BOT CHORD 9-15=-513/889, 8-15=-513/889, 7-8=-308/588 -
WEBS 2-11=-610/311„ 2-10=-223/646, 3-8=-319/218, 4-8=-26/358, 4-7=7720/377
NOTES-
1) Wind: ASIDE 7-10; Vult=170mph (3-second gust) Vasd=1 32mph;, TCDL=4.2psf; BCDL=5.Opsf; h=15ft; Cat. 11; Exp C; Encl.,
GCpj=0.18; MWFRS (envelope); cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) '. This truss has been designed for a live load of 20.Opsf on:the:bottom chord in all areas where a rectangle 3-670 tall by 2-0-0 wide
will fit between the bottom chord and any othermembers.
4) Refer to girder(s) for truss to truss connections.:
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 59 lb uplift at joint 5, 357 lb uplift at joint
11 and 205 lb uplift at joint 7.
6) "NAILED" indicates 3-10d (0.148"x3") or 2-12d (0.148"x3.25") toe -nails per NDS guidlines.
7) In the. LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). .
LOAD CASE(S). Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-5=-70, 1-10=-20,:6-9= 20
Concentrated Loads (lb)
Vert: 8= 66(F=-33, B=-33) 4=-83(F=.-42; B— 42) 15=-18(F=-9, B=-9)
s.
Walter P. Finn PEEN6.22639
MiTek USA, Inc. FL Cart6634E.
69 East Blvd. Tampa
64 Parke E F1.000 E
.. Date:.. ..
October 10,2019
WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MX7473 rev. IW032015 BEFORE USE.
Design valid for use only with MITek® connectors. This deslgn is based only upon parameters shown, and Is for an Individual building component, not
a,tluss system. Before use, the, building designer must verify the applicability of design parometers.and properly Incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only.. Additional temporary and permanent bracing
M iTek"
Is always.required for stability and to prevent.collopse with possible personal Injury and property damage. For general guidance regarding the : .. .
.
fabrication;. storage; delivery, erection and bracing of trusses and truss systems, seeM1SVFP11 Quality CrIl la, DSB-89 and SCSI Building Component.
6904 Parke East Blvd.,
Safety Infonnatlonavoilable from Truss Plate Institute, 2.18 N. Lee Street. Suite 312, Alexandrla, VA 22314. ..... . ..
Tampa, FL 33610 .
Job
Truss
Iruss lype
QtyPly
T18336006
20103091-TNT
V1
Valley
1
1
Job Reference (optional)
tiumers rirsisource, tort niece, t-L 34e4b
v
0
0
nun: n.z4u s t-eo i i zui a rnnt: n.e4u saw zt zui a MI i eK inousmes, mc. i nu act r u r u: i suu eu 1 a rage 1
ID:PftLgjXzGof3aThkEwERV6zC114-Mxse190K1h3nGnUoRCEXeHsROmppBZYAaiygUyyUsUH
8-0-0
8-0-0
2x4 II Scale = 1:21.3
3
5 4
2x4 i 2x4 I 2x4 II
LOADING (psf) SPACING- 2-0-6 : CSI. DEFL. in (loc): I/defl Ud .-PLATES GRIP
TCLL 20.0 Plate Grip DOL 1.25 TC 0.26 Vert(LL) n/a n/a 999 MT20 244/190
TCDL 15:0 Lumber DOL 1.25 BC 0.20 Vert(CT) n/a n/a 999.
BCLL 0.0 Rep Stress Incir YES WB 0.15 HOrz(CT) -0.00 4 n/a n/a
BCDL 10.0 Code FBC2017lTP12014 Matrix-SH Weight: 29lb . FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puffins, except .
BOT CHORD 2x4 SP No.3 end verticals.
WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4:SP No.3
REACTIONS. (lb/size) 1=110/7-11-6, 4=143/7-11-6, 5=386/7-11-6
Max Horz 1=165(LC 12) .
Max Uplift 4=-75(LC 12); 5= 202(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown... .
TOP CHORD 1-2=-276/1,13
WEBS 2-5=-320/502
NOTES'
1) Wind: ASCE 7-10; Vult=170mph (3=second gust) Vasd=132mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; Cat;,:ll; Exp C; Encl.,
- GCpi=0.18; MWFRS (envelope) and C-C Exterior(?) 0-9-1 to 6-9-1, Interior(1) 6-9-1 to:7-10-4 zone; cantilever left and right exposed
;C-C for members and: forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.:
3) This truss has been designed for a 10.0 psf bottom chord live load noriconcurrent with any other:live loads:
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any othermembers.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 75 lb uplift at joint 4 and 202 lb uplift at
joint 5.
LOAD CASE(S) Standard
A WARNING -Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCEPAGE 'MIP7473 rev. 10103/2015 BEFORE USE.
-Design valid for use only with MiTek® connectors. This design Is based only upon parameters' shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters, and. properly Incorporate this design Into the overall
building design. Bracing indicated 'is to buckling of individual truss.web and/or chord members only. Additional temporary and permanent bracing
MiTek`
prevent
Is always required for stability and to prevent, collapse with possible personal Injury and property damage. For general guidance regarding the: .. .
.
fabrication, storage; delivery, erection and bracing of trusses and truss systems, seeANSVrP11 Quality Cdlorla, DSB-89 and BCSI Bu9ding Component:
6904 Parke East Blvd.,
Safety Infonnatlonavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610.. .
Job
Truss
russ Type
Qty
Ply
T18336007
20103091-TNT
V2
Valley
1
1
Job Reference (optional
ID:PftLdXzGof3aThkEwERV6zC114-Mxse190K1h3nGn6o96EXeHsIPmki5d ti aiygUyyUsUH
6.0-0
6-0-0
2x4 I Scale =1:16.4
2
.. 3
.
- 2x4 2x4 11
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.81
Vert(LL) n/a n/a 999
MT20 244/190
TCDL 15:0
Lumber DOL 1.25
BC , 0.55
Vert(CT) n/a n/a 999:
BCLL 0.0
Rep Stress Incr YES
WB: 0.00
Horz(CT): 0.00 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix-P
Weight: 20 lb .. FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural .wood sheathing directly applied or 6-0-0 oc purlins; except
BOT CHORD 2x4 SP No.3 end verticals.
WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0
oc bracing:
REACTIONS. (lb/size) 1=229/5-1'1-6, 3=229/5-11-6-
Max Harz 1=119(LC 12)
Max Uplift 1=-70(LC 12), 3=r120(LC 12)
FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
\
TOP. CHORD 2-3=-204/332.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf;kDL=5.0psf; h=15ft; Cat.:ll; Exp C; Encl.,
GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS
for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom,chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. -
4) . This truss has been designed for a live load of 20.Opsf on.the.bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 70 lb uplift at joint 1 and 120 lb uplifFat'
joint 3.
LOAD CASE(S) Standard
Walter P. Finn PE No.22839
. • .
MiTek USA, Inc. FL Cart 6634:
6904 Parke East Blvd. Tampa FL 33610.
Date:
Otobe c r 10,2019
. - WARNING - Verify design parameters end READ NOTES ON THIS AND INCLUDED MTTEK REFERANCEPAGE1411-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
al
'-
a truss system. Before use, the. building designer must verity the applicability of design parameters, and properly Incorporate this design Into the overall
building design. Bracing indicated is to buckling Individual truss.web and/or chard members only. Additional temporary and permanent bracing
MiTek`
prevent of
Is alwayssecluired for stability and to prevent. collapse with possible personal Injury and'property damage. For general guidance regarding the' ' ' ... '
6904 Parke East Blvd..
fabrication; storage; delivery, erection and bracing of trusses and truss systems, seeANSVTPII Quality Criteria, DSB-69 and BCSI Bull Component:
Tampa, FL 33610.. •
Safety InformaHonavoilable from Truss Plate Institute, 218 N. Lee Street Suite 312, Alexandria, VA 22314. ..... .:
.
Job
I russ
Truss Type
Qty
Ply
T1B336006
20103091-TNT
V3
Valley
1
1
Job Reference (optional)
om�uers nracouurue, run riew, r� ovavo
v
a
0
ID: PftLgjXzGof3aThkEwERV6zC114-g7Q1 yU 1 yo?Betx3_?vImBV PbOAAIt27KoMhD00yUsUG
-0
-0
I Scale =1:11.0
2
3
2x4. % 2x4 11
LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Well Ud PLATES GRIP
TCLL 20.0 Plate. Grip DOL 1.25 . TC 0.28 Vert(LL) n/a n/a 999 MT20-.. 244/190 .
TCDL 15.0 Lumber DOL 1.25 BC . 0.19 Vert(CT) n/a n/a 999.
BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT): 0.00 n/a n/a
BCDL 10.0 Code FBC2017/TP12014 Matrix-P Weight: 13 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied Dr 4-0-0 oc purlins; except -
BOT CHORD 2x4 SP No.3 end verticals.
WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 1=140/3-11-6, 3=139/3-11=6
Max Harz 1=73(LC 12)
Max Uplift 1=-43(LC 12), 3=-73(LC 12)
FORCES. (lb) - Max. Comp./Max. Ten. - Al] forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph.(3-second gust) Vasd=132mph; TCDL=4.2psf;.BCDL=5.Opsf; h=15ft; Cat. 11; Exp.C; Encl.,
GCpi=0.18; MWFRS (envelope) and.C-C.Exterior(2) zone; cantilever left and:right exposed;C-C for members and forces & MWFRS,
for reactions shown; Lumber DOL=1:60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0.ta11 by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Provid'e mechanical connection (by others) of truss to bearing plate capable of withstanding 43 lb uplift at joint 1 and 73 lb uplift at,
joint 3:
p.
A' WARNING- Verily design parameters and READ NOTES ON: THIS AND INCLUDED mrTEK REFERANCE PAGE'M11-7473 rev. M3/2015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not•
a truss system. Before use, the building designer must verity the applicability of design porometers,and properly Incorporate this design into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only.. Additional temporary and permanent bracing
MiTek`
is always required for stability and to prevent.coliapse with possible personal Injury and,property damage. For general guidance regarding the : , ...
fabrication; storage; delivery, erection and bracing of trusses and truss systems, seeANSV1Pl1 GualBy Crlterla, DSB-69 and BCSI Building Component:
.
_ _ ' . '
6904 Parke East Blvd.
Safety Infonnatlonavaliable from Truss Plate Institute, 2,18 N. Lee Street, Suite 312, Alexandria, VA 22314. .. ..... . .:
Tampa, FL 33610.. ,
Job
russ
Truss Type
Uty
Ply
T18336009
20103091-TNT
V4
Valley
1
1
Job Reference (optional)
, ...., .............. __ .
ID:PftLgjXzGof3aThkEwERV6zC114-g7Q1yU1yo?Betx3_?vlmBVPf9ACpt27KWk hD6 0yUsUG
r 2-0.0 r
2-0-0
5.00 F12 2
2x4
Scale = 1:6.9
i
LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP
TCLL 20.0 Plate Grip DOL 1.25 TC 0.04 Vert(LL) n/a n/a 999 MT20 244/190
TCDL 15.0 Lumber DOL 1.25 BC0.03 Vert(CT) n/a n/a 999; ,
BCLL 0.0 Rep Stress lncr YES WB 0.00 Horz(CT)_ -0.00 2 n/a n/a
BCDL 10.0 Code FBC201.7/rP12014 Matrix-P Weight: 5 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP.No.2 : TOP CHORD Structural Wood sheathing directly applied or 2-0-0 oc purlins.
BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS: (lb/size) 1=56/1-11=6, 2=44/1-11=6, 3=12/1-11-6 ..
Max Horz 1=30(LC 12)
Max Uplift 1=-17(LC 12), 2=-36(LC 12)
Max Grav 1=55(LC 1), 2=44(LC 1), 3=25(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten.-- All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; Cat. 11; Exp.0; Encl_
GCpi=0.18; MWFRS (envelope) and:C-CExterior(2) zone; cantilever left and,right exposed ;C-C for members and forces & MWFRS
for reactions shown; Lumber DOL=1:60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) " This truss has been designed for a live load of 20.Opsf on.the bottom chord in a11areas where a rectangle 3-6-01all by 2-0=0 wide
will fit between the bottom chord and any other members.
5) Bearing at joint(s) 2 considers parallel to' grain value using ANSVTPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 17 lb uplift at joint 1 and 36 lb uplift at
joint 2.
LOAD CASE(S) Standard
0 WARNING- Verify design parameters and READ NOTES ON, THIS AND INCLUDED MirEK REFERANCEPAGE MIP7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the. building designer must verify the applicability of design parometers.and properly Incorporate this design Into the overall
building design. Bracing Indicatedisto buckling of individual truss,web and/or chord members only.. Additional temporary and permanent bracing
MiTek,
prevent
Is always required for stability and to prevent, collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication; storage; delivery, erection and bracing of trusses and truss systems, seeANSVTPl1 Quality Criteria, DSB.89 and SCSI BuOding Component:
6904 Parke East Blvd.,
Safety Informatlonavailable from Truss Plate Institute; 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610.. .:
Job
I russ
Truss Type
uly
Ply
..
..
T18336010
20103091-TNT
V5
Valley
1
1
.
Job Reference (optional)
nuuuers nrsrouurue, run rieue, rL
I D: PftLgjXZGof3aThkEW ERV6zC114-g7Q1 yU1.yo?Betx3_?VlmBVPZgA72tOLKoMhDOOyUsUG
1000
10.0-0
.. 2x4 .Scale = 1:26.0 .
.. .. - 3
1�
0
...2z4 , .. 5 .. _ .. ..
2x4. I.
42x4. II ..
LOADING (psf)
SPACING- 2-0-11,:
CSI.
DEFL. in (Idc) ' I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1:25
TC 0.39
Vert(LL) Na Na 999
MT20 .: 244/190
TCDL 15.0
Lumber DOL 1.25
BC. 0.33
Vert Na - Na • .999
(CT)
BCLL 0.0
Rep Stress.locr YES
WB'0.18.
Horz(CT)' 0.00 4 Na n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix-SH
Weight: 37 lb 'FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP N0.2 TOP CHORD St[uctural wood sheathing directly applied or 6-0-0 oc purlins, except
BOT CHORD 2x4 SP No.3 end verticals.
WEBS 2x4'SP No.3 BOT_ CHORD Rigid ceiling directly applied'or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
REACTIONS. (lb/size). 1=145/9=11-6, 4=179/9-11-6, 5=495/9-11-6 )
Max.Horz 1=212(LC 12)
Max Uplift 4=-93(LC 12); 5=-259(LC 12) . . .
FORCES. (lb) - Max. Comp./Max. Ten. = All forces 250 (lb) or less except when shown.
TOP CHORD 1-6==332/95, 2-6==320/137
WEBS 2-5=-394/601
NOTES-
1) Wind: ;ASCE7-10; Vult=170mph (3 second gust) Vasd=132mph; TCDL=4:2psf; BCDL=5.Opsf; h=15ft; Cat. ll; Exp C; Encl.,
GCpi=0.18; MWFRS (envelope) and C-C Exterior(2).0-9-1 to 6-9-1, Interior(1) 6-9-1 to 9--104 zone; cantilever left and right exposed
;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing. "
"
3) This truss .has been designed for a 10.0 psf, bottom chord live load noncgncurinent with any other live loads.. . : . ' . . .
4) *This truss, has been designed fora IiVe load of 20.Opsf on the bottom chord in all areas where; a. rectangle 3-6-0 tall by 2-0-0 wide..
will fit between the bottom chord and any other'members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 93 lb uplift at joint 4 and 259 lb uplift at
joint 5.
LOAD CASE(S) Standard
.. ..
•
Walter P. Finn PE:No.22839
MiTek USA, Inc f.L Cert 6634
East st Blvd. Tampa
:Parke. m a F4 3.3610.
Date;
October 10;2019
®:WARNING -. Verify design parameters and READ NOTES ON THIS AND INCLUDED M/TEK REFERANCE PAGE MIk7473 rev. 1WO12015 BEFORE USE.
Design valid for use only with MTek® connectors. This design is. based only upon parameters shown, ,and Is for an individual building component, nott'
a. truss system. Before use, the building designer must verify.the applicability of design parameters:and properly Incorporate this .design Into the overall
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporaryyand permanent bracing .
MiTek'
Is always:required for stability and to prevent collapse with possible personal Injury,.and property damage. For general guidance regarding the : :.. ..
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSU1PI1 Quality CrBoda, DS8-11119.and BCSI Building Component " .
... .
6904 Parke East Blvd..
Saloty Informatlo available from Truss Plate Institute, 218 N. Lee Street, Suite:312, Alexandria, VA 22314,
Tampa, FL 33610 . . .
Symbols
PLATE LOCATION AND ORIENTATION
3/4 Center plate on joint unless x, y
offsets are. indicated.
Dimensions are in ff-in-sixteenths...
.Apply plates to both sides of truss
and fullyembed teeth.
For 4 x 2 orientation, locate
plates 0-1/0 from outside
edge of truss.
This symbol indicates the
required direction of slots in
connector plates.
Plate location details available in MTek 20/20
software or upon request.
PLATE SIZE
The first dimension is the plate
width measured perpendicular
4 x 4
to slots. Second dimension is .
the length parallel to slots.
LATERAL BRACING LOCATION
Indicated by symbol shown and/or
by text in the bracing section of the
output. Use T or I bracing .
if indicated,
BEARING
Indicates. location where bearings
(supports) occur. Icons vary but
reaction section indicates joint
number where bearings occur.
Min size shown is for crushing only.
Industry Standards:
ANSI/TPI1: National Design Specification for Metal
Plate Connected Wood Truss Construction.
DSB789: Design Standard for Bracing..
BCSI: Building Component Safety Information,
Guide to Good Practice for Handling,
Installing & Bracing. of Metal Plate
Connected Wood Trusses.
Numbering System
6-4-8 dimensions shown in .ff-in-sixteenths
(Drawings not to. scale)
1 2 3
0
c
O
U
d
0
8 7 -- 6 5
JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE: .
AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO
THE LEFT.
CHORDS AND WEBS ARE IDENTIFIED BY END JOINT
NUMBERS/LETTERS
PRODUCT CODE APPROVALS
ICC-ES Reports:
ESR-1311, ESR-1352, ESR1988
ER-3907, ESR-2362, ESR-1397, ESR-3282 .
Trusses are designed for wind loads in the plane of the
truss unless otherwise shown.
Lumber. design values are in accordance with ANSI/TPI -1
section 6.3 These truss designs rely on lumber values
established by others.
2012 MiTekO All Rights Reserved
MiTek"
MiTek Engineering Reference Sheet: Mll-7473 rev. 10/03/2015
:General Safety Note
Failure to Follow Could- Cause Property
Damage or Personal Injury
T. Additional stability bracing for truss system, e.g.
diagonal or X-bracing, is always required. See BCSI:
2. Truss bracing must be designed. by an engineer..For'
wide truss spacing, individual lateral braces: themselves
may require bracing, or alternative Tor I
bracing should be considered: .
3. Never exceed the design loading shown and never
stack materials on inadequately braced_ trusses.
4. Provide copies of this truss design to the building ..
designer, erection supervisor, property owner and
all other interested parties.
5. Cut members to bear tightly against each other.
6. Place plates on each face of.truss at each
joint and embed fully. Knots and wane at joint .
locations are regulated by ANSI/TPI 1.
7. Design assumes trusses will be suitably protected from
the environment in accord with ANSI/TPI 1.
8. Unless otherwise noted, moisture content of lumber
shall not exceed 19% of time of fabrication.
9. Unless expressly noted, this design is not applicable for
use with fire retardant, preservative treated,, or green lumber.
10. Camber is a non-structural consideration and. is the
responsibility of truss fabricator. General practice is to
camber for dead load deflection.
11. Plate type, size, orientation and location. dimensions . . .
indicated are minimum:plating requlrements.
12. Lumber used shall be of the species and size, and..*:'...
in all respects, equal to or better than that
specified.
13. Top chords must be sheathed. or purlins provided at
spacing indicated on design. -
14. Bottom chords require lateral bracing at 10 ft. spacing,
or less, ifno ceiling is installed, unless otherwise noted.
15. Connections not shown are the responsibility of others..
16. Do not cut or alter truss member or plate without prior .
approval of an engineer.,
17. Install and load vertically unless indicated otherwise.
18. Use of green or treated lumber may pose unacceptable
environmental, health or performance risks. Consult with
project engineer before use.
19. Review all portions of this design (front, back, words
and pictures) before use.,Reviewing pictures alone
is not sufficient.
20. Design assumes manufacture in accordance with
ANSI/TPI 1 Quality Criteria.
s