HomeMy WebLinkAboutREVISION, Electronic Plans PDFs 4-13-21Additional
45 bars
Lintel
Bar
Clear
"A"
"
Length
Length
Span
Bars
Bars
CLEAR
COVER
2'-10"
2'-8"
'-
16"
2,U3
none
.' Precast Lintel
i '• �.i
2'-2"
2,1t3
none
8F8-OB/IT
Additional
4'-0"
3'-10"
2'-8"
2,U3
none
CLEAR ''.:!`
4'-6"
4'-4"
3'-2"
2,U3
none
COVER One Row of Beam
5'-4"
5'-2"
4'-O"
2,U3
none
Block Above
2,U4
none
Precast Lintel
none
- i Additional
�'-6"
_1'-0"
6'-2"
2,U5
none
CLEAR a------ #5 bars '' ----y
COVER
8FI6-IB/IT 8FI6-IB/2T
8'-4"
7'-10"
7'-0"
2,U5
none
NOTES:
ALL reinforcing steel is grade 60.
L MIN. COVERAGE OF STEEL = 1.5"
2. MIN. BEARING REQUIRED 8 EA. END = 4"
3. STANDARD FOR REINF. STEEL = ASTM A615 GRADE 6O
TYPICAL LINTEL SECTION
( PRECAST CONCRETE )
LINTEL SCHEDULE
Window
Pre-
Rows of
Max.
Max.
Max.
Mark
or Door
Unit
Lintel
Cast -Crete
Stressed
BM Block
Above
Bottom
Top
Gravitg
Load
Uplift
Load
Lateral
Load
Width
Size
Specification
Steel
Size
Steel
Size
(PLF)
(PLF)
(PLF)
L20
2'-0"
2'-10"
8F8-OB/IT
NO
—
1
#5
3069
1569
IL42
2'-2"
L31
2'-6"
V-9"
8F8-OB/IT
NO
—
1
45
25LI
1363
%3
L45
4'-5"
5'-1"
8F8-OB/IT
NO
—
I
#5
1349
1016
411
L50
5'-O"
5'-8"
8F8-OB/IT
NO
—
1
#5
1105
909
339
L60
6'-8"
6'-8"
8F8-OB/IT
NO
—
I
#5
1011
121
534
L10
T-O"
1'-0"
8F8-OB/IT
NO
—
1
#5
1011
-12-1
534
L80
8'-0"
8'-8"
8F8-OB/IT
NO
—
1
#5
699
591
512
L90
9'-0"
9'-8"
8F8-OB/IT
NO
—
I
#5
535
530
401
- ALL LINTELS SHALL BE MADE BY CAST-CRETE.
- LINTELS
SHALL BE FILLED SOLID WITH 3000 PSI CONCRETE
- REFER TO CAST-CRETE CATALOG FOR ALL INFORMATION REGARDING
LINTEL CONSTRUCTION, HANDLING INFORMATION, AND SAFE LOAD
REQ.
REQUIREMENTS
- LINTELS
OVER
13'-11" LONG ARE TO BE PRESTRESSED.
- CONTRACTOR
TO VERIFY ALL LINTEL SIZES BASED ON FINAL
MASONRY
OPENING
SIZES AND ADJUST LINTELS ACCORDINGLY PRIOR TO ORDERING
ANY/ALL
LINTELS
2" x 6" PT wood secured with overhead door track secured to wood
1/2"dia. x 6" expansion anchors jamb per manufacturer's product approval
with 2" sq. washer at 18" o.c.
ALL GARAGE DOORS AS SPECIFIED IN PRODUCT
APPROVAL ON THESE PLANS. DOORS TO MEET
WIND PRESSURE STATED IN PERMIT INFO BOX ON
THESE PLANS
Gdracle Door Jamb Detail
NTS
Verify all stucco banding and
trim per elevations
Stucco return
Attach door to block wall with
1/4" dia. x 3" tap -cons with min.
1 1/2" penetration at 12" o.c. max
and 6" o.c. max from each corner thru
I" x 8" PT Buck
Exterior
See door schedule and
floor plan for size and locations
install door per product approval bg mfg
Drywall return
Interior
See tgpical wall sections for interior
drgwall finish notes
verify filled cell count per
floor plans at window jambs
Exterior Door Jamb Detail
NTS
Seal ALL concrete block jambs prior
to buck per FBC R1O3.8 using any
approved sealant
VERIFY ALL SILL MATERIAL
WITH OWNER PRIOR TO ORDERING
VERIFY ALL ROUGH OPENING
SIZES WITH THEIR RESPECTIVE
MANUFACTURER PRIOR TO
INSTALLING MASONRY
Drywall
Sill - v
material
with own
to order
Er
SEAM SCHEDULE
Mark Size and Description
61 Two rows of beam block filled with concrete and (1) #5 bar
continuous in each row. Provide precast lintel filled with
concrete and (1) #5 bar per lintel schedule continuous
over openings.
X
a
0
Typ. 1Iasonrq Filled Cell Detail
NTS
Dowel (1) #5 bar
w/ 25" min lap
and 6" embed
ete Footing
Missed T« DOuir R&baIr
nts
Verify all stucco banding and
trim per elevations
Stucco return
Attach window to block wall with
1/4" dia. x 3" tap -cons with min.
1 1/2" penetration at 12" o.c, max
and 6" o.c. max from each corner thru
I" x 4" PT Buck
See window schedule and
floor plan for size and locations
install window per product approval bg mfg
Drywall return
Interior
See typical wall sections for interior
drywall finish notes
verify filled cell count per
floor plans at window iambs
Window Jamb Detail
NTS
Lintel — see plans for
size and steel req.
Attach mndom to block mall oath
1/4• dia. x 3" tap -corn with min.
I I/4' penetration at ac oco max
and L' o.c. max Prom each corner thru
I" x 4' PT Buck
stucco return
See window schedule and
floor plan for size and locations
Stucco finish over sill
slope for drainage
Pour concrete sill
over tin cap
Section Window Head lt Sill
NTS
iced Cells
(Typical)
1/2"x 4 1/
isonrg Inspe,
Clean Out
O° bend fir,
8 bar dia. I
id footing
Existin
Filled Cell Masonry Column With One
U5 From Footing To Beam.
Conc. Fill To Be 3000 PSI
See Floor Plan For Location
S1ngI Filled Cell Column
NTS
Filled Cell Masonry Column With One
U5 From Footing To Beam Each.
Conc. Fill To Be 3000 PSI
See Floor Plan For Location
Double Filled Cell Column
R esid&nc& to New A d6tion Connection Details
Sanibel Flat Roof Tile installed per product
Tapproval FLU 3019-1.1 and evaluation report using
IOd ring shank nails over ppolyglass self adhered
roofing underlagment over 1`1/32" CI_
plywood attached
to trusses per sheeting attachment diagram on roof plan.
Simpson HETA 20 or equal
hurries e c or at each truss 12
with (12) �� x I I/2" nails
24" supporting Max. \ 6 SLOP
18101bs. uplift
Galt' -Alum Metal drip on
I" x 4" Drip on _
I" x 8" Fascia on
2" x 6" Sub -Fascia
24"
5/8" thick stucco on 3/8" hi -rib lath /
attached to horizontal and vertical wood
framing with nails or staples to provide
no less than 1-3/4" penetration into
horizontal wood framing and 3/4" penetration
into vertical wood framing members
5/8" thick light textured
stucco on typical concrete
block construction
45 bar vert. w/
30" overlap —
at each filled cell
I" Block recess for
waterproofing at
slab (Optional)
Grade
NTS TYPIC,4L SECTION
I�
Cl
Typical
Baseboard
R-30 Batts Insulation
PRE-ENGINEERED TRUSSES
at 24"o.c. TYPICAL
( shop drawings by manufacturer )
5/8" drywall w/ smooth finish
1/2" drywall over I" x furring
strips at 16" o.c. with R-4.2 fyfoil
insulation on typical 8" Block walls
All drywall is per FBC 102.3.1 and
shall meet all pertaining ASTM codes.
Mortar to be Type "M" only.
Provide Dur-O-Rock at all wet
areas (ex. showers, tubs etc...)
Fill cell with concrete and
(1) 45 bar vert. (typical).
Max. spacing shall not exceed
32" unless otherwise noted
see foundation plan notes for
spacing at openings
4" concrete slab with fibermesh OR
Cx6" 410/10 WWM on 6 mil Visqueen over
clean compacted termite treated fill
SCALE 1/2" = 1'-0"
SCALE 1/2" = I'-O"
Corner Steel Lap
nts
Digitally signed by
Daniel R. Braden
Date: 2021.04.13
15:42:22-04'00'
LU
Q
QL
--
c<1
g9j�
�O
>OCm
Q>' <I- Ln a0
� 0
"N
U U
+, 00 00
E
O"<
� 1 1
0���
03
CV CV
it
1
Urr
N
k3
-0a
Q3�`���
}
U r X
ra J
L_ •q (U
~
E U-
I
U] }'
L
(n
Sheet
I
OF 1.
Comm #
20-21,4
........o V!jK
CN
01% R. � �4,
0
°
o°�°�°DEC
QIs�D°la�_„nV/