Loading...
HomeMy WebLinkAboutSOUTHEAST2-CoverGENERAL NOTES 1, ALL WORK SHALL COMPLY WITH THE 6TH EDITION 2017 FLA BUILDING CODE,EXISTING BUILDING CODE, THE DEPT. OF BUSINESS REGULATION STANDAR THE FLORIDA ADAPTATION OF THE DISABILITY STANDARDS, FLORIDA ENERGY CONSERVATION 2014 NEC, NFPA 101 (2015 EDITION), 6th EDITION FLORIDA FIRE PREVENTION CODE W/PBC LOCAL AMENDMENTS, NFPA 241, 2013 NFPA 72. 2. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE FIELD. NOTIFY ARCHITECT /ENGINEER OF ANY DESCREPENCIES PRIOR TO COMMENCING WORK. 3. PATCH ALL EXISTING FLOORS , CEILINGS & WALLS DAMAGED DURING CONSTRUCTION. 4. WHEREVER NEW CONSTRUCTION MEETS EXISTING, MATCH MATERIALS IN COLORS AND THICKNESS. 5. VERIFY ALL FINISH CONDITIONS WITH TENANT PRIOR TO INSTALLATION. 6. THESE PLANS ARE BASED ON INFORMATION SUPPLIED BY TENANT. VERIFY ALL CONDITIONS IN FIELD. 7. BUILDINGS WITH AUTOMATIC SPRINKLER SYSTEM: PROVIDE ENGINEERED SPRINKLER SHOP DRAWINGS FOR PERMIT. 8. PROVIDE 2A-10BC FIRE EXTINGUISHER AT EACH EXIT AND TYPE K EXTINGUISHER IN KITCHEN UNLESS DIFFERENT INDICATED BY FIRE DEPT. 9. GENERAL CONTRACTOR SHALL OBTAIN ADEQUATE LIABILITY INSURANCE. AND MAINTAIN SUCH UNTILL CONPLETION OF PROJECT. 10. GENERAL CONTRACTOR SHALL PROVIDE COMPLETE CLEANING AT COMPLETION OF PROJECT. 11. THE INTENT OF THESE DOCUMENTS IS TO INCLUDE ALL WORK AND ITEMS NECESSARY FOR THE PROPER COMPLETION OF THE WORK. THEREFORE, ALL ITEMS NECESSARY FOR THE COMPLETION OF WORK SHALL BE REQUIRED WHETHER OR NOT INDICATED ON PLANS OR CONSTRUCTION DOCUMENTS, BUT ARE REASONABLY INFERABLE AS BEING NECESSARY TO PROVIDE INTENDED RESULTS. 12. ALL MATERIALS SHALL BE NEW AND CODE APPROVED. 13. ALL WORK SHALL BE PROPERLY COMPLETED. ALL WALLS SHALL BE FINISHED SMOOTH. 14. CONSTRUCTION/ DEMOLITION SHALL NOT INTERFERE WITH EMERGENCY VEHICLE ACCESS/RESPONSE TO SITE AND FIRE LANES. 15. COMBUSTIBLE WASTE AND DEBRIS SHALL BE REMOVED AFTER EACH SHIFT. SPECIFICATIONS CEILING: 1. F1 - ARMSTRONG DUNE 2. C2 - ARMSTRONG CIRRUS FLOOR FINISH: 1. F1 - PORCELIN TILE AS SELECTED BY TENANT 2. F2 - CARPET AS SELECTED BY TENANT 3. F3 - VINYL COMPOSITE TILE AS SELECTED BY TENANT MILLWORK: 1. ALL MILLWORK SHALL BE PLASTIC LAMINATE FINISH OVER 3/4" PLYWOOD ON ALL EXPOSED SURFACES. PROVIDE TENANT WITH SHOP DRAWINGS AND PLASTIC LAMINATE SAMPLES FOR APPROVAL. 2. A COUNTERS SHALL HAVE 4" MIN. LAMINATED BACKSPLASH. CAULK TO WALL. WALLS: RETAIL/OFFICES ALL WALLS SHALL BE PAINTED ( COLOR AS SELECTED BY OWNER ). ALL GYPSUM WALLS SHALL BE TAPED, TEXTURED AND SHALL RECIEVE TWO COATS OF PAINT. PAINT ALL UNLESS NOTED. RESTROOMS: ALL WALLS TO RECIEVE CERAMIC TILE TO 5' AFF. PAINT ABOVE. RESTROOM WALLS TO RECIEVE TILE BASE. KITCHEN WALLS TO RECIEVE RESIN OR TILE BASE TO MATCH FLOOR. THESE SPECIFICATIONS ARE A GUIDE ONLY. TENANT MAY CHANGE WHERE CODE PERMITS. ANY DETAILS PROVIDED IN BODY OF PLANS SHALL SUPERCEDE ANY INDICATIONS MADE IN THESE SPECIFICATIONS. nOTIFY ARCHITECT OF ANY CONFLICTS. FLAME SPREAD GROUP: ® 1. Class A Interior Finish. Flamespread 0-25, Smoke Developed 0-450. Any element thereof when do tested shell not continue to propagate fire. ❑ 2. Class B Interior Finish. Flamespread 26-75, Smoke Developed 0-450. ❑ 3. Class C Interior Finish. Flamespread 76-200, Smoke Developed 0-450. MINIMUM INTERIOR FINISH CLASSIFICATION: OCCUPANY UNSPRINKLERED SPRINKLERED Exit Other Exit Other Exit1 Access Spaces Exit1 Access Spaces OCCUPANT LOAD: RETAIL-24 PEOPLE / WAREHOUSE-18 PEOPLE = 42 TOTAL SQUARE FOOTAGE SHOWROOM - 1463 Sp. ff. STOCK ROOM 5287 Sp. ff OCCUPANCY TYPE MERCANTILE /STORAGE CONSTRUCTION TYPE: 1� PLAN REVIEW 25MAR2021 III B UN-SPRINKLERED LEVEL 3 ALTERATION PLUMBING FIXTURES WATER CLOSETS: REQUIRED- 1 PROVIDED- 2 LAVATORIES: REQUIRED- 1 PROVIDED- 2 PROFESSIONAL STATEMENT TO THE BEST OF MY KNOWLEDGE, THESE PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE FIRE SAFETY STANDARDS AS DETERMINED AND AS INTERIOR IMPROVEMENTS SOUTH EAST SPAS 227 PROFESSIONAL WAY, SUITE 200 WELLINGTON, FLORIDA 33414 PLAN REVIEW 4APRIL2020 METRO ARCHITECTURAL GROUP LLLP AA# 26001493 PH# (561) 686-5853 FAX# (561) 686-5862 SCOPE OF WORK: 1. REMOVE ALL WALLS INDICATED ON DEMOLITION PLAN. 2. REMOVE EXISTING DROPPED CEILINGS IN SHOWROOM. 3. INSTALL 8'w. ROLL -UP DOOR BETWEEN SHOWROOM AND WAREHOUSE. 4. REPLACE 2x2 CEILINGS IN SHOWROOM PER PLAN. 5. REPLACE FLOORING IN SHOWROOM. 6. REPLACE 20 FLOURESCENT LIGHTING IN SHOWROOM WITH NEW LED. 7. REPLACE EXISTING 2x2 PERFORATED AC SUPPLIES WITH NEW CONE LAY -IN. 8. REMOVE ALL WALL ELECTRICAL DEVICES 9. REMOVE AND REPLACE ALL SHOWROOM FLOORING. 10. ENLARGE (1) RESTROOM AND UPGRADE TO CURRENT ACCESSIBILITY STANDARDS THE ARE NO NEW ELECTRICAL DEVICES. TERMINATE RECEPTACLES FROM REMOVED WALLS EXISTING LIGHT SWITCH AT ENTRY SHALL SHALL REMAIN TO CONTROL REPLACEMENT LED 20 LAY -IN FIXTURES ALL WORK SHALL COMPLY WITH 2O17 FLORIDA BUILDING CODE. AND 2014 NEC. CONSTRUCTION TYPE 36 OCCUPANCY -MERCANTILE /STORAGE SHOWROOM - 1463 SD. Ff. STOCK ROOM 5287 Sp. Ff ZL NON-SPRINKLERED DRAWING INDEX C1 = COVER SHEET 1.0a = FLOOR PLAN 1.1 a = REFLECTED CEILING LIGHTING P LAN TH OM AS J. TWOM EY P. E. #25626 JAM ES C. P AI N E ARCHITECT RA #9524 PETE RU SSO- PRES. PH# (561) 686-5853 2831 A EXCHANGE CT. WEST PALM BEACH, FLORIDA 33409 NORTH FEDERAL HWY: w� .-f 11.'N SUBJECT BUILDI V. �F • � _ dal r� <'�.. � c W Digitally signed by Thomas J Twomey DN: c=US, o=Unaffiliated, ou=A01410C0000016E89479A3 700008DB6, cn=Thomas J Twomey Date: 2021.04.09 12:40:07-04'00' KEY PLAN C N.T.S.