Y r4$}Product Approval
I ( ) USER: Public User
`/
bp
PreEucf Aabrbval Menu > Prpnua ur A(tplt[abun
SeacT > gppbcatlan List > Application Detail
FL #
FL14317-R11
-`-—"--- —' Application Type
Revision
Code Version
2020
Application Status
Approved
Comments
Archived
Product Manufacturer Boral Roofing
Address/Phone/Email 7575 Irvine Center Drive
Suite 100
Irvine, CA 92618
(801)380.5091
RobinAnderson@boral.com
Authorized Signature Anderson Robin
RobinAnderson@boral.com
Technical Representative Adrian Cooper
Address/Phone/Email 135 NW 20th Street
Boca Raton, FL 33431
(954) 520-5461
acoopeer@minierlifetile.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J. M. Nleminen
Evaluation Report
Florida License
PE-59166
Quality Assurance Entity
UL LLC
Quality Assurance Contract Expiration Date
04130/2023
Validated By
John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
• t r r • �u.L L!•i
Standard
ASTM D1970
FRSA/TRI 6th Edition
TAS 103
ILL 1897
Year
2015
2018
2020
2015
Sections from the Code
www.8oridabuilding.org/pripr_app_dii.aspx?param=wGEVXQwtDgsbCUITKel20BoXpSjktfpju5SjCfgNBzeRczhREBCXVw%3tl%3d 1/2
2112/2021
Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted 11/25/2020
Date Validated 12/05/2020
Date Pending FBC Approval 12/12/2020
Date Approved 02/09/2021
Summary of Products
FL # Model, Number or Name Description
14317.1 Boral Roof Untlerlayments j Roof underlayments for use In prepared roof assemblies
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL14317 RI 11 2020 11 25 FINAL ER BORAL Underlayments FL14317-
Approved for use outside HVHZ: Yes R31•R11f
Impact Resistant: N/A Verified By: Robert J. M. Nleminen PE - 59166
Design Pressure: +N/A/-210 Created by Independent Third Party: Yes
Other: 1.) The design pressure in this Evaluation Reports
application pertains to a particular underlayment FL14317 RI I AE 2020 11 25 FINAL ER BORAL Untlerlayments FL14317- j
system for use in the roof systems. Refer to ER RRZt p&
Section 5.6.2. 2.) Refer to ER Section 5 for Limits Created by Independent Third Party: Yes
of Use.
Conta.ct.U5:: 26QI Blair Stone Road, Tnllahasee FL 32399 Phone: 850-487-1824
The State of Florida Is an ANECO employe, Cgpyrlaht 2907-2013 State of Flnritla.:: Privacy, Statement :: Accessibibla, Statement :: Refund Statement
Under Ronnie law, email addresses are .but records. Ir you do not want your. -mad address released In response to a public-rocends mgaest, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact SSO.487.1395. 'Pursuant to Section 455.275(l),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an.mall address If they have one. The .mails
Provided may be used far ofOclal communication with the Seer... However .moll addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine If you are a Ikensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
Credit Card
Safe
w.loridabuilding.org/pripr_app_dtI.aspx?param=wGEVXQwtDgsbCUITKel2OBoXpSjktfpiu5SjCfgNBzeRmhREBCXVw%3d%3d 212
NEMO I etc.
Certificate of Authorization 832455
353 Christian Street, Unit #13
Oxford, CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
EVALUATION•
Boral Roofing Evaluation Report M35710.12.10-R12
7575 Irvine Center Drive, Suite 100 FL14317-R11
Irvine, CA. 92618
(602)269-2288
Date of Issuance:12/21/2010
Revision 12: 11/25/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The products described herein have been evaluated for
compliance with the 71h Edition (2020) Florida Building Code sections noted herein.
DESCRIPTION: Boral Roof Underlayments
WELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO)etc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6
Prepared by:
Robert l.M. Nieminen, P.E.
:�'.;:+.j �;2T` The facsimile seal appearing was authorized by Robert
Florida Registration No. 59166, Florida DCA ANE1983
.°..... .',:•�"" Nicminea,P.E.on 11/25/2020. This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nleminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
02018, NEW ETC, LLC
NNEMOJetc.
ROOFING COMPONENT EVALUATION:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Boral Roof Underlayments, as marketed by Boral
Roofing, have demonstrated
compliance with the following sections of the 7" Edition (2020) Florida Building Code through testing in
accordance with the following Standards. Compliance is subject to the Installation
Requirements and Limitations
/ Conditions of Use set forth herein.
Section Property Standard
Year
1504.3.1 Wind resistance UL 1897
2015
1507.1.1, 1507.2.4, 1507.2.9.2 / Material standard ASTM D1970
2015
R905.1.1, R905.2.8.2
1507.3.3 / R905.3.3 Material standard FRSA/TRI, Sixth Edition
2018
TAS 110 Material standard TAS 103
2020
C
4.1
4.2
4.3
4.4
4.5
Entity
Examination
Reference
Date
ERD (TST 6049)
ASTM D1970 / D4798
M36790.07.11
09/30/2011
ERD (TST 6049)
ASTM D226, 01970
B40380.08.12
08/28/2012
ERD (TST 6049)
TAS 103-20 (tensile adhesion)
C41420.09.12-2
09/11/2012
ERD (TST 6049)
ASTM D1970 (adhesion)
B41940.09.12
09/13/2012
ERD (TST 6049)
TAS 103-20 (tensile adhesion)
B47390.07.14-1
07/31/2014
ERD (TST 6049)
TAS 103-20 (tensile adhesion)
B47390.09.14
09/04/2014
OC (PDM1838)
Physical Properties
Equivalency statement
11/02/2017
PRI (TST 5878)
ASTM D1970
NEI-031-02-02:REV
10/27/2010
PRI (TST 5878)
ASTM D1970
NEI-029-02.01:REV
12/03/2010
PRI (TST 5878)
TAS 103-20(tensile adhesion)
NEI-046-02-01REV
12/17/2010
PRI (TST 5878)
FRSA/TRI April 2012
NEI-076-02-01
02/14/2011
PRI (TST 5878)
ASTM D1970
NEI-034-02-02
01/29/2013
PRI (TST 5878)
Wind Uplift
BORR-001-02-01
03/17/2015
PRI (TST 5878)
Wind Uplift
BORR-005-02-01
06/24/2015
PRI (TST 5878)
TAS 103-20 (tensile adhesion)
DAPF-002-02-01
03/08/2018
PRI (TST 5878)
ASTM D1970 (adhesion)
OCF-443-02-01
10/11/2018
UL, U.C. (QUA 9625)
Quality Assurance
Service Confirmation
08/21/2017
UL, LLC. (QUA 9625)
Quality Assurance
Florida BCIS
Current
Description
Product
Material Standard
Plant(s)
Boralm TileSeal 5011i
ASTM D1970
Brentwood,
nominal 50-mil thick, polyester -surfaced, self -adhering SBS
NH
modified bitumen roof underlayment
Boral® TileSeal"T
ASTM D1970 and
Brentwood,
nominal 60-mil thick, polyester -surfaced, self -adhering SBS
FRSA/TRI 09-18
NH
modified bitumen roof underlayment
Boral° MetalSeal"r
ASTM D1970 and
Brentwood,
nominal 60-mil thick, polyester -surfaced, self -adhering SBS
FRSA/TRI09-18
NH
modified bitumen roof underlayment
GatorSeal"
ASTM D1970
Brentwood,
nominal 55-mil thick, granule -surfaced, fiberglass reinforced,
NH
self -adhering SBS modified bitumen roof underlayment
Citadel- Plus
ASTM D1970
Brentwood,
nominal 48-mil thick, fabric -surfaced, fiberglass reinforced,
NH
self -adhering SBS modified bitumen roofing underlayment
for use as a base -layer in multi -ply underlayment systems
NEMO ETC, LLC Evaluation Report M35710.12.10-R12
Certifcate o)Authoritotion#32455 7"' EDITION (20201 FBC NON.HVHZ EVALUATION FL14317-R11
Soral Roof Underlayments; (602) 269-2288 Revision 12: 11/25/2020
Page 2 of 6
' NEMO I G'eC.
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record forany project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -
Dade Counties).
5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.5 Boral Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers: Table 1 pertains to use of each listed underlayment by -itself beneath the stated roof
covers. Refer to the installation instructions for multi -ply underlayment options.
TABLE 1: ROOF COVER OPTIONS
FBC Section:
1507.2
1507.3
1507.4 & 1507.5
1507.7
1507.8 & 1507.9
Clay and Concrete The
Metal
Slate or
Wood
Underlayment
Asphalt
Shingles
Slate -Type
Mechanical
Adhesive•
Panels
Shingles
Shingles&Shakes
Attach
Set
Shingles
RoralTileSeal50w
Yes
No
No
Yes
Yes
Yes
Yes
(jointstrips, I507.1.1.3/R905.1.1.3)
Boral TileSealHT
Yes
Yes
Yes
Yes
Yes
Yes
Yes
(See 5.6.1)
(jointstrips, 1507.1.1.3/005.1.1.3)
Boral MetalSealHT
Yes
Yes
Yes
Yes
Yes
Yes
Yes
fs"e5.6.31
(jointstrips, 1507.1.1.3/R905.1.14
GatorSeal
Yes
No
No
No
No
Yes
Yes
(joint snips, 150Z1.1.3/R905.1.1.3)
5.6.1 Adhesive -set is limited to use of following underlayment / tile -adhesive combinations.
TABLE IA: ALLOWABLE UNDERLAYMENT / TILE -ADHESIVE COMBINATIONS'
Underlayment
Adhesive
Florida Product
Approval
Boral TileSealHT or Boral MetalSealHT
DAP Foam "Touch'n Seal Storm Bond Roof Tile Adhesive'
FL14506
Boral TileSeal"T or Boral MetalSealHT
DAP Foam "Touch'n Seal StormBond 2 Two -Component
Polyurethane Roof Tile Adhesive'
FL21374
Boral TileSeal"T or Boral MetalSealHT
Dupont "Tile Bond'" Roof Tile Adhesive"
FL22525
Boral TileSealHT or Boral MetalSealHT
ICP Adhesives and Sealants "Polyset" AH-160"
FL6332
Boral TileSealHT or Boral MetalSealHT
ICP Adhesives and Sealants "Polyset°' RTA-1"
FL6276
1 Refer to Tile Manufacturer's orAdhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance
NEMO ETC, LLC Evaluation Report M35730.12.10-R12
certificate ofAothorimtion 832455 7n'EDITION (2020) FBC NON.HVH2 EVALUATION FL14317-RII
Boral Roof Underlayments; (6021269-2288 Revision 12: 11/25/2020
Page 3 of 6
ZNEM01ei-c'
5.7 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Underlayment
Application
Primer
Substrates
Citadel Plus, Boral TileSeal 50"T, Boral
TileSeal"T, Boral MetalSeal"T or GatorSeal
self -adhering
(Optional) ASTM D41
plywood
none
ASTM D226 Type 11 felt or Citadel Plus
ASTM D41
metal (flashing metal, valley metal, etc.)
Boral TileSeal"T, Boral MetalSeal"T
self -adhering
(Optional) ASTM D41
OSB
Boral TileSeal"T
self -adhering
(Optional) ASTM D41
Huber "Zip Deck"
None
G-P Gypsum "DensDeck Prime"
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with
the manufacturer's installation instructions, but — for mechanically attached underlayments or base sheets - not
less than FBC 1507.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation
instructions, but not less than Section 5.8.3 herein.
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. The Maximum Design Pressure
is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing
pressure divided by 2 (the 2 to 1 margin of safety per FBC 2504.9 has already been applied).
5.8.3.1 Direct -to -Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the
critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
#1 Maximum Design Pressure = -120.0 post:
Deck: Min, 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: (Optional) ASTM D41 to the plywood deck
Base Ply: Citadel Plus, self -adhered
Cap Ply: Boral TileSeal"T or Boral MetalSeal"T, self -adhered, and back -nailed within the selvedge -edge side
laps using 12 ga. x IX" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.
#2 Maximum Design Pressure = -142.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Ply: None
Cap Ply: Boral TileSeal"T or Boral MetalSeal"T, self -adhered and back -nailed within the selvedge -edge side
laps using 12 ga. x IY<" ring shank nails through 32 ga., 1.5/8" diameter tin caps spaced 12-inch o.c.
#3 Maximum Design Pressure=-202.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: Tropical Roofing Products #410 Quick Dry Primer or other ASTM D41 primer to the plywood deck
Base Ply: None
Cap Ply: Boral TileSeal"T or Boral MetalSeal"T, self -adhered, and back -nailed within the selvedge -edge side
laps using 12 ga. x IY" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.
NEMO ETC, LLC Evaluation Report M35710.12.10-R32
Certificate of Authorization N32455 71.. EDITION (2020)FBC NON-HVH2 EVALUATION FL14317.R11
Boral Roof Underlayments; (602) 269-2288 Revision 12: 11/25/2020
Page 4 of 6
0 NEMO I etc.
#4 Maximum Design Pressure=-210.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: KARNAK #89 Sta-Tak Primer to the plywood deck
Base Ply: None
Cap Ply: Boral TileSeal''' or Boral MetalSeal"', self -adhered, and back -nailed within the selvedge -edge side
laps using 12 ga. x 1'/." ring shank nails through 32 ga., 1-5/8" diametertin caps spaced 12-inch o.c.
#5 Maximum Design Pressure=-120.0 psf:
Deck: Min. 2,500 psi structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: ASTM D41 to the concrete deck
Base Ply: (Optional) Citadel Plus, self -adhered
Cap Ply: Boral TileSeal"' or Boral MetalSeal"r, self -adhered
#6 All other direct -deck, adhered underlayment systems beneath tile roof systems carry a Maximum Design
Pressure of -45 psf.
5.9 Exposure Limitations:
TABLE 3: ExPOSURE LIMITATIONS
Maximum
Underlayment
Prepared Roof Cover Installation Type
Exposure
(days)
GatorSeal
Mechanically attached
30
Boral TileSea150"T
Mechanically attached
180
Adhesive -set tile roof system
30
Boral TileSeal"T or Boral MetalSeal"T
Mechanically attached
180
/
Citadel Plus(boseply in multi -ply underlayment systems only)
(prior to placement of subsequent underlayment)
180
5,10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the
maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during
loading of the roof tiles.
TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRELT-DECK TILE INSTALLATIONS
Underlayment•
Tile Profile
Staging Method
Maximum Slope
Boral TileSeal"' or Boral MetalSealH'
Flat or Lugged
Max. 10-tile stack
6:12
6.1 Boral Roof Underlayments shall be installed in accordance with Boral Roofing published installation instructions
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application, and prime the substrate (if applicable).
6.3 Boral TileSeal 50"r or GatorSeal:
6.3.1 Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in
FBC 1507.1.2.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering
to be installed, and the manufacturer's installation instructions.
When installed over a mechanically attached, FBC Approved ASTM D226 Type 11 felt, the felt shall be fastened in
accordance with FBC 1507.1.1 or R905.1.1.
NEMO ETC, LLC Evaluation Report M35710.12.10-R32
CertifmW.f Authorization d32455 7O1 EDITION (2020) FBC NON-HVHZ EVALUATION FL14317-All
Boral Roof Underlayments; )602) 269.2288 Revision 12: 11/25/2020
Page 5 of 6
ONEMOjetc.
6.3.2 Multi -Ply Underlayment Systems:
One or two plies of Citadel Plus followed by Boral TileSeal 50"T or GatorSeal is allowable for use under
mechanically attached, non -tile prepared roof systems. Limits of use are those associated with the top -layer
material. This is not a requirement, but is allowable if a multi -ply underlayment system is desired.
6.4 Boral TileSeal"TorBoral MetalSeal"T:
6.4.1 Non -Tile Applications:
Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in
FBC 1507.1.2.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering
to be installed, and the manufacturer's installation instructions.
When installed over a mechanically attached, FBC Approved ASTM D226 Type II felt, the felt shall be fastened in
accordance with FBC 1507.1.1 or R905.1.1.
6.4.2 Tile Applications:
Shall be installed in compliance with requirements for a Self -Adhered Membrane in the FRSA/TRI Florida High
Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, and the manufacturer's installation
instructions.
Refer to Section 5.8.2 for attachment limitations.
Refer to Table 4 for tile staging limitations.
6.4.3 Multi -Ply UnderlaVment Systems:
One or two plies of Citadel Plus followed by Boral TileSeal"T or Boral MetalSeal"T is allowable for use under
mechanically attached, non -tile prepared roof systems. Limits of use are those associated with the top -layer
material. This is not a requirement, but is allowable if a multi -ply underlayment system is desired.
Refer to Section 5.8.2 for use of Citadel Plus as a base ply membrane in underlayment systems for use under tile -
roof systems.
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the
product.
Contact the named CIA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
UL LLC—QUA9625; (414) 248-6409;
END OF EVALUATION REPORT -
NEMO ETC, L C Evaluation Report M35710.12.10-R32
Certifimte of Authorimtlon 032455 7"'EDITION (2020)FBC NON-HVHZ EVALUATION FL14317-R11
aoral Roof Underlayments; 16021269-228B Revision 12; 11/25/2020
Page 6 of 6