Loading...
HomeMy WebLinkAboutEngineering Architectonic Inc St. Lucie County Planning& Development Services Building&Code Regulation Division 2300 Virginia Ave. Fort Pierce, FL 34982 RECEIVED APR 0 3 1011 April 7,2021 Permittirg Dapartment St. Lucic County RE: 3409 Industrial 271h Street, Fort Pierce, FL 34946 To Whom It May Concern: Our office has performed design pressure calculations for the above referenced project and herby certify that the proposed garage door is in compliance with the 2020 Florida Bu de 165hwind zone, KEWIEWEU exposure "C", risk category III. PR CODE COMPLIANCE From Table 1609.3.1: V,it= 165mph ST. LUCIE COUNTY OCC From Table 1609.7 : 14' h x 14'w door, 1 - -(1) 65 mph= 24.8/ 27.6 From Table 1609.7(2): 15' mean roof height, Exposure C= 1.21 Required Design Pressures: 24.8 X 1.21=29.8 File Copy -27.6X1.21=33.5 Product:Janus International Group, LLC.,Series 3100 26 ga. Door Assembly, FL#12765.3 Product Pressures: +36.0&-41.0 Res p�e�c-t� ly-�S�®itted, Michae Seal,AIA Ar. hitecto�r'i�c;pl kv 806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg#AA26003348 1 of 1