HomeMy WebLinkAboutEngineering Architectonic Inc
St. Lucie County
Planning& Development Services
Building&Code Regulation Division
2300 Virginia Ave.
Fort Pierce, FL 34982 RECEIVED
APR 0 3 1011
April 7,2021
Permittirg Dapartment
St. Lucic County
RE: 3409 Industrial 271h Street, Fort Pierce, FL 34946
To Whom It May Concern:
Our office has performed design pressure calculations for the above referenced project and herby certify
that the proposed garage door is in compliance with the 2020 Florida Bu de 165hwind zone,
KEWIEWEU
exposure "C", risk category III. PR
CODE COMPLIANCE
From Table 1609.3.1: V,it= 165mph ST. LUCIE COUNTY
OCC
From Table 1609.7 : 14' h x 14'w door, 1 - -(1) 65 mph= 24.8/ 27.6
From Table 1609.7(2): 15' mean roof height, Exposure C= 1.21
Required Design Pressures: 24.8 X 1.21=29.8 File Copy
-27.6X1.21=33.5
Product:Janus International Group, LLC.,Series 3100 26 ga. Door Assembly, FL#12765.3
Product Pressures: +36.0&-41.0
Res p�e�c-t� ly-�S�®itted,
Michae Seal,AIA
Ar. hitecto�r'i�c;pl kv
806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com
Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg#AA26003348 1 of 1