Loading...
HomeMy WebLinkAboutProduct Approval (2) 398 East Dania Beach Blvd. /n/4A\\ BUILDING DROPS Suite338 A Perfect Solution in Every Drop! Dania Beach, FL 33004 Certificate of Authorization:29578 954.399.8478 PH 954'744.4738 FX contact@buildingdrops.com Product Evaluation Report Of RECEIVEp ,ikgAR 2 Silver Line Building Products Corp. Permitting DzPartment V1 Series / 70 Series Single-Hung Window (2127) S` Lucie`°u (Impact) (HVHZ) for Florida Product Approval FL# FL14911 Report No. 548 Current Florida Building Code Method: 1— D (Engineering Evaluation) Category: Windows Sub— Category: Single Hung C m G o Product: V1 Series/70 Series Single Hung Wine ® �w (2127) ® !91 l Material: PVC 0 0 00 a C Product Dimensions: See Installation Instructions, SWD050 0 ! �d Prepared for: ) Silver Line Building Products Corp. 0 One Silverline Dr. W North Brunswick, NJ 089021rr�0'�`'�i ems` �,... •• ��' N Prepared by: �� E ,s 0 Hermes F. Norero, P.E. _ ' : 77 lV Florida Professional Engineer#73778 �' °v _ 5 A OF ., Date:01/23/2018 f Contents: ��j F`s G�' Evaluation Report Pages 1-3 ��i� O Digitally signed by Hennes F.Norero,P.E. Hermes{f1Not6f P.E. Reason:I am approving this document Florida No.73778 Date:2018.04.19 00:55:47-04'00' BUILDING DROPS FL#: FL14911 A Perfect Solution in Every Drop! Date: 0 3/2018 Certificate of Authorization:29578 Report Noo:: 5486 Manufacturer: Silver Line Building Products Corp. Product Category: Windows Product Sub-Category: Single Hung Compliance Method: State Product Approval Method (1)(d) Product Name: V1 Series/70 Series Single Hung Window(2127) Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL#73778)for Sliver Line Building Products Corp. based on Method 1d of the State of Florida Product Approval, Florida Department of Business and Professional Regulation-Florida Building Commission. Hermes F. Norero, P.E.does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity"involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the Current Florida Building Code. See Installation Instructions SWD050,signed and sealed by Hermes F. Norero, P.E. (FL#73778)for specific use parameters. Limits of Use: 1. This product has been evaluated and is in compliance with the Current Florida Building Code, including the"High Velocity Hurricane Zone"(HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Chapter 16 of the Current Florida Building Code and does not require an impact resistant covering. 4. Site conditions that deviate from the details of drawing SWD050 require further engineering analysis by a licensed engineer or registered architect. 5. See Installation Instructions SWD050 for size and design pressure limitations. Hermes F. Norero, P.E. Florida No. 73778 Page 2 of 3 /. A\\ BUILDING DROPS FL#: FL14911 A Perfect Solution in Every Drop! Date: O - 018 Report No:o: 54 5486 Certificate of Authorization:29578 Quality Assurance: The manufacturer has demonstrated compliance of window products in Accordance with the Current Florida Building Code and State Rules for manufacturing under a quality assurance program audited by an approved quality assurance entity through Window and Door Manufacturers Association(FBC Organization#: QUA2515). Performance Standards: The product described herein has been tested per: • TAS 201-94 • TAS 202-94 • TAS 203-94 • ASTM E330-02 • ASTM E1886-05 • ASTM E1996-06/09/12 • AAMA/WDMA/CSA 101/i.S.2/A440-08 Referenced Data: 1. Product Testing performed by National Certified Testing Laboratories, Inc. (FBC Organization#TST1589) Report: Dated: NCTL 110-16327-1 08/13/2013 Signed and Sealed by: Harold E. Rupp, FL PE No 15935,Sealed Date 02/06/18 NCTL110-16327-2 11/05/2013 NCTL 110-16327-3 08/13/2013 2. Quality Assurance Window and Door Manufacturers Association (FBC Organization#: QUA2515) 3. Material Certification Miami-Dade County Notice of Acceptance Eastman Chemical Company(Previously Solutia) Saflex(Vanceva Composites) PVB Interlayer 4. PVC profiles meet requirements of WDMA/HallMark WD-61 in accordance with AAMA 303 Installation: Refer to Installation Instructions(SWD050)for anchor spacing and more details of the installation requirements. Design Pressure: Refer to Installation Instructions(SWD050)for anchor spacing and more details of the installation requirements. Hermes F. Norero, P.E. Florida No. 73778 Page 3 of 3 398 East Dania Beach Blvd. BUILDING DROPS Suite338 A Perfect Solution in Every Drop! Dania Beach, FL 33004 Certificate of Authorization:29578 954.399.8478 PH 954.744.4738 FX contact@buildingdrops.com Product Evaluation Report of AMERICAN CRAFTSMAN WINDOWS SILVER LINE WINDOWS AND DOORS 70 Series/V3 Series/ (5800) Gliding Patio Doors (IMPACT) (HVHZ) for Florida Product Approval _ FL# FL14998 Report No. 7292 Current Florida Building Code Method: 1—D (Engineering Evaluation) Category: Exterior Doors Sub—Category: Sliding Exterior Door Assemblies - Product: 70 Series/V3 Series/(5800) Gliding Patio Doors (IMPACT) (HVHZ) Material: Vinyl Product Dimensions: See Installation Instructions,SWD040 Prepared for: Silver Line Windows and Doors One Silverline Dr. �`. E North Brunswick, N! 08902 *` .`•" ' '• N 7 p Prepared by: Hermes F. Norero, P.E. -0� S A OF Florida Professional Engineer#73778 p IpP•:' ���� Date: 10/15/2020 -ell ` Contents: �O, Evaluation Report Pages 1—3 Digitally signed by Hermes F Norero Hermes F. Norero, P.E. Reason:I am approving this document Florida P.E. No. 73778 Date:2020.10.22 02:32:28+02'00' BUILDING DROPS FL#: FL14998 A Perfect Solution in Every Drop! Date:10/15/20 Certificate of Authorization:29578 Report No: 7292 Manufacturer: Silver Line Windows and Doors Product Category: Exterior Doors Product Sub-Category: Sliding Exterior Door Assemblies Compliance Method: State Product Approval Method (1)(d) Product Name: 70 Series/V3 Series/(5800)Gliding Patio Doors (IMPACT) (HVHZ) Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL#73778)for Silver Line Windows and Doors based on Method 1d of the State of Florida Product Approval, Florida Department of Business and Professional Regulation -Florida_Building Commission. Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the current Florida Building Code. See Installation Instructions SWD040,signed and sealed by Hermes F. Norero, P.E. (FL#73778)for specific use parameters. Limits of Use: 1. This product has been evaluated and is in compliance with the current Florida Building Code, including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Chapter 16 of the current Florida Building Code and does not require an impact resistant covering. 5. Site conditions that deviate from the details of Installation Instructions SWD040 require further engineering analysis by a licensed engineer or registered architect. 6. See Installation Instructions SWD040 for size and design pressure limitations. Hermes F. Norero, P.E. Florida P.E. No. 73778 Page 2 of 3 BUILDING DROPS FL#: FL14998 A Perfect Solution in Every Drop! Date:10/15/20 Certificate of Authorisation:29578 Report No: 7292 Quality Assurance Entity: The manufacturer has demonstrated compliance of products in accordance with the Florida Building Code for manufacturing under a Quality Assurance Entity through Window and Door Manufacturers Association (FBC Organization#QUA2515). Performance Standards: The product described herein has been evaluated per: • TAS 201-94 • TAS 202-94 • TAS 203-94 Referenced Data: 1. Product Testing performed by National Certified Testing Laboratories,Inc. (FBC Organization# TST 1589) Report#: 110-15666-1 Report Date: 12/14/2012 Report#: 110-15666-2 Report Date: 01/10/2013 Report#: 110-15934-1 Report Date: 03/25/2013 2. Quality Assurance Entity Window and Door Manufacturers Association (FBC Organization#QUA2515) 3. Material Certification Miami-Dade Country RER Product Control Office NOA Current NOA for PVB Interlayer by Kuraray America (Previously DuPont) 4. Material Certification Miami-Dade Country RER Product Control Office NOA Current NOA for PVB Interlayer by Eastman Chemical Co(Previously Solutia) 5. PVC profiles certified by AAMA in accordance with AAMA 303 Installation Method: Please refer to installation instructions,SWD040,for anchor methods,selection,spacing, edge distances, embedment's and further details of installation. Design Pressure: Please refer to installation instructions,SWD040,for mull combination grouping, configurations, and corresponding design pressures. Hermes F. Norero, P.E. Florida P.E. No. 73778 Page 3 of 3