Loading...
HomeMy WebLinkAboutAPPROVED 2870 Gregory Ln - Underlayment Product Approval11412UZI Florida Building Code Online Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search D01 Product Approval M: Public User Product Approval Menu > Product Or Ai?pliCgkion, Search > ggplication Li;;t > Application Detail FL V Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method FL2569-R20 Revision 2020 Approved Soprema, Inc. (Canada) 1640 rue Haggarty Drummondville, NON -US 00000 (819)478-2400 memathieu@sap re ma , ca Marc -Etienne Mathieu memathieu@soprema.ca Marc -Etienne Mathieu 1688 Jean-Berchmans- Michaud Drummondville, NON -US 00000 (819)478-2400 Ext3327 memathieu@soprema.ca Jean -Francois Cote, Ph.D. 1640 rue Haggarty Drummondville (888)811-3145 jfcote@soprema.ca Roofing Underlayments e" Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect !Name who developed the Robert 3. M. Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 04/10/2023 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL2569 R2.0 C.01. 20_2D_ 01 COI NIEMINEN.pjf Referenced Standard and Year (of Standard) Standard Year ASTM D1970 2015 ASTM D4798 2011 ASTM D6163 2015 FM 4474 2011 FRSA/TRI Sixth Edition 2018 UL 1897 2012 https:llflohdabullding.orglprlpr_app_dtl.aspx?param=wGEVXQwtDgsKQFEnckB10BErxl Ud3xYlmjtrnBrpDan9H30QGunUKXA%3d%3d 112 1141'20L i Florida Building Code Online Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 09/19/2020 Date Validated 09/22/2020 Date Pending FBC Approval 09/29/2020 Date Approved 12/15/2020 Date Revised 12/16/2020 Summary of Products 7- FL # Y Model, Number or Name Description 12569.1 Soprema Roof Underlayments Self adhering roof underlayments Limits of Ilse Installation Instructions Approved for use in HVHZ: No FL25§9 R20 11 2020 09 17 FINAL ER FL2 -R O.pdf Approved for use outside HVH2: Yes Verified By: Robert N)eminen, P.E. PE-59166 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-150 Evaluation Reports Other: 1.) Refer to ER Section 5 for Limits of Use. 2,) The FL2569 R20 AE 2020 09 17 FINAL ER F 2569-R2 .pd design pressure noted herein pertains to underlayment systems Created by Independent Third Party: Yes used beneath adhesive -set tile systems. Refer to ER Section 5.6.4 for details. Contact Us :: 2601 Blair Stone Road Tallahassee FL 32399 Phone: 650-487-1824 The Stale of Florida Is an AA/EEC employer, Cop ri ht 20 7-2013 Stale of F on r: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are pubiic records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850,487,1395. 'Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: Credit Card Safe https://fioridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsKQFEnckBIOBErxlUd3xYlmjtrnBrpDan9H30OGunUKXAa/e3da/e3d 212 n LJ NEMO I etc. Certificate of Authorization #32455 353 Christian Street, Unit 413 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT Soprema, Inc. Evaluation Report S18010.06.09-R18 1640 rue Haggerty FL2569-R20 Drummondville, Quebec J2C 5P8 Canada Date of Issuance: 06/15/2009 (819) 478-2400 Revision 18: 09/17/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 71h Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: Soprema Roof Underlayments LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.1.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time asthe named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). MEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO Ietc. Evaluated" may be displayed in advertising literature, If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59155, Florida DCAANE198.3 CERTIFICATION OF INDEPENDENCE' The facsimile seal appearing was authorized by Robert �% FS>`;;'••• ' c' - Nieminen, P.E. on 09/17/2020. This does not serve as '!^•�,.+'•"• an electronically signed document. 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO FTC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. O2o19 NEMO ETC, LLC ON EMo I etc. ROOFING COMPONENT EVALUATION: Product Category: Roofing Sub -Category. Underlayment Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the following sections of the 7`h Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations Conditions of Use set forth herein. Section Property Standard Year 1504.3.1 Wind resistance FM 4474 2011 1504.3.1 Wind resistance UL 1897 2012 1507.1.1, 1507.2.4, 1507.2.9.2 Material standard ASTM D1970 2015 / R905.1.1, R905.2.8.2 1507.3.3 / R905.3.3 Material standard FRSA/TRI, Sixth Edition 2018 1507.11.2 / R905.11.2 Material standard ASTM D6163 2015 TAS 110 Accelerated Weathering ASTM D4798 2011 En_ tits Examination Reference Date LRD (T5T6049) Wind Resistance 2778.07.05 07/15/2005 ERD (TST6049) ASTM 01970 / TAS 110 (QC) S31370.03.10-1-R1 04/07/2010 ERD (TST6049) FRSA/TRI 04-12 (OH) 511150.05.09-R2 10/05/2010 ERD (TST6049) ASTM D1970 (OH) 537210.11.11 11/09/2011 ERD (TST6049) ASTM D1970 (M5) 537210.12.11 12/01/2011 ERD (TST6049) ASTM D1970 (MS) S40540.02.13-1 02/19/2013 ERD (TST6049) FRSA/TR104-12(MS) S43530.02.14-1-R1 02/21/2014 ERD (TST6049) ASTM D1970 (BC) S44870.04.14-2 04/02/2014 ERD(TST6049) ASTM D1970(QC) S44870.04.14-3 04/02/2014 ERD (TST6049) ASTM D1970 (OH) S44870.04.14-1 04/10/2014 ERD (TST6049) ASTM D1970 (MS) 544870,04,14-4 04/10/2014 ERD (TST6049) ASTM D1970 (OH) 540540.10.14 10/31/2014 ERD (TST6049) Tensile Adhesion / Long Term Aging SOPC-5C7645.02.15 02/13/2015 ERD (TST6049) Accelerated Weathering SOPC-SC8520.04.14 04/27/2015 ERD (TST6049) Wind Resistance SOPC-SC14045.05.17-RI 06/07/2017 M-D (CER1592) HVHZ Compliance 18-0329.03 06/28/2019 ICC-ES (EVL2396) 201S IBC Compliance ESR-1524 03/01/2017 NFMO (TST6049) ASTM D1970 / TAS 110 (QC) SOPC-SC8970.08.15-Ri 04/25/2018 NEMO (TST6049) Wind Resistance 4-50PC-18-003.08.18 08/27/2018 NEMO (TST6049) ASTM D4798/D1970 (OH & MS) 4S-SOPC-18-002.05.19.A 05/31/2019 NEMO (TST6049) Tensile Adhesion / Long Term Aging 4p-DOW-I9-SSLAP-01.A.R2 02/10/2020 NEMO (TST6049) Peel adhesion (existing underlayments) 4j-SOPC-I9-SSUDL-04.A 03/12/2020 PRI (TST5878) ASTM D1970 (MS) SOP-064-02-01 17/03/2013 Soprema, Inc. (PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015 UL, LLC (QUA9625) Quality Control MLA File No. R2760S OS/08/2019 UL, LLC (QUA9625) Quality Control Service Confirmation 06/29/2020 MEMO ETC, LLC Evaluation Report 518010.06.09-R18 Certificuleof Authorization #32455 7T11 EDITION (2020) EBL NON-HVHZ EVALUATION FL2569-R20 Soprema Roof Underlayments Revision 18: 09/17/2020 Page 2 of 8 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 t4NEMO ! etc. ,.rrUCT DESCRIPTION: Product Material Standard Plant(s) Description Lastobond TV HT ASTM D1970 and Gulfport, MS self -adhering, non -woven polyester fabric FRSA/TRl 09-18 surfaced, SBS modified bitumen roof underlayment Lastobond Shield ASTM D1970 _ Drummondville, QC self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths; 36 and 45 inch RESISTO SA SMOOTH PLY ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, SBS 40 modified bitumen roof underlayment Lastobond Shield HT ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, high temperature, SB5 modified bitumen roof underlayment Lastobond Pro HT-N ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths; 36 and 45 inch Lastobond Pro HT-S ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, high temperature, 5B5 modified bitumen roof underlayment EnviroShield ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment Lastobond 195 ASTM D1970 Gulfport, MS self -adhering, glass -mat reinforced, sand - Wadsworth, OH surfaced, SBS modified bitumen roof underlayment Lastobond Eaves ASTM D1970 Gulfport, MS self -adhering, glass -mat reinforced, sand - Protection Sheet Wadsworth, OH surfaced, SB5 modified bitumen roof underlayment Lastobond Eco ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand - Gulfport, M5 surfaced, 5135 modified bitumen roof Wadsworth, OH underlayment Lastobond Smooth Seal ASTM D1970 Gulfport, MS self -adhering, glass -mat reinforced, film - HT Wadsworth, OH surfaced, SBS modified bitumen roof underlayment PrimeSource Grip -Rite ASTM D1970 Gulfport, MS self -adhering, glass -mat reinforced, film - Smooth Seal HT Wadsworth, OH surfaced, SBS modified bitumen roof underlayment RES15TO LB1236 ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand - Gulfport, MS surfaced, SBS modified bitumen roof Wadsworth, OH underlayment PrimeSource Grip -Rite ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand- Eave & Valley Protector Gulfport, MS surfaced, SBS modified bitumen roof Wadsworth, OH underlayment 5RS TopShield ICE & ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand - WATER DEFENDER Gulfport, MS surfaced, SBS modified bitumen roof Wadsworth, OH underlayment RESISTO LB1244 ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand - Gulfport, MS surfaced, SBS modified bitumen roof Wadsworth, OH underlayment NEMO ETC, LLC Certificate ofAuthorizution N32455 7'H EDITION 120201 F13C NON-HVHZ EVALUATION Soprema Roof Underlayments Evaluation Report 518010A6.09-R18 FL2569-R20 Revision 18: 09/17/2020 Page 3 of 8 4.17 0NK1Pn'4n1"n'+'- Product Material Standard Plant(s) Description Colphene FR GR ASTM D6163 Gulfport, MS self -adhering, fiberglass reinforced, granule - Wadsworth, Oft surfaced, SBS modified bitumen roof underlayment S.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in F3C High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami - Dade Counties). 5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.6 Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS Clay and Concrete Tile Slate or Asphalt (1507.3) Metal State-TypeWood Underlayment Shingles Mechanical Adhesive- Panels Shingles Shingles (15072) Shingles Attach Set j1507.4) (1507,5) (1507.7) (1507.8) Shakes (1507.,9) Lastobond TU HT Yes Yes Yes Yes Yes Yes Yes Yes See S.b.1 [joint strips, 1507.1.1.3 (joint strips, 1507.1.1.3 / R905.1.331 f R905.1.1.3) Lastobond Shield / Pro HT-N Yes Yes / RESISTO SA SMOOTH PLY Yes No No No No Yes {joint strips, 2507.1.1.3 (join[ strips, 1507.1.1.3 40 /R905.1.1.3# /R905.i,1.3) Lastobond Shield HT/ Pro Yes Yes HT-S Yes No No Yes Yes Yes Ijoint strips, 1s07.1.1.3 {joint strips, 1507.1.1.3 R905.1.1.3) Yes Yes fnviroShiefd Yes No No Yes Yes Yes Ijoint strips, I507.1.1.3 {join) strips, 1507.1.1.3 J R905.1.1.3) / R905.1.1.3# Lastobond Eaves Protection Yes Yes Sheet / Lastobond 195 Yes No No No No Yes {joint strips, 1507.1.1.3 {jointstrips, 1507.1.1.3 / R905.1.1.3} / R9U5.1.1.31 Lastobond ECO / RESISTO 1.131236, Grip -Rite Eave & Yes Yes Vafley Protector /TopShield Yes No No No No Ycs (joint strips, 7507.1.1.3 (joint strips, 7507.1.1.3 ICE & WATER DEFENDER/ f R905.1.1.31 /R905.1.1.3) RESISTO W1244 Lastobond Smooth Seal HT J Yes Yes Grip -Rite Smooth Seal HT Yes No No Yes Yes Yes )joint strips, 1507.1.1.3 (join[ strips, 1507.1.1.3 / R9os.1.1.3) / R9ns_1.1.3] Yes Yes Colphene FR GR Yes Yes No No No Yes [joint strips, 1507.1.1.3 (joint strips, 1507. i1.3 / R905.1.1.31 1 / R9os.1.1.3) NEMO ETC, LLC Evaluation Report S18010.06.09-1118 Cerrificote ofAuthorizotion #32455 75n EDITION 12020i FBC NON-HVHZ EVALUATION FL2569-R20 Soprema Roof Underlayments Revision 18; 09/17/2020 Page 4 of 8 MEMO 1 etc. 5.6.1 Adhesive -set tile is limited to use of the following Approved underlayment / tile -adhesive combinations. TABLE ZA: ALLOWABLE TILE ADHESIVE / UNDERLAYMENT COMBINATIONS' Underlayment Adhesive Florida Product Approval Dupont "Tile Bond"" Roof Tile Adhesive" FL22525 Lastobond TU HT ICP Adhesives and Sealants "Polyset" AH-160" FL6332 S.7 Allowable Substrates: TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS Underlayment Application Substrates (designed to meet wind loads for project) Type Primer Material(s) Lastobond Shield, Lastobond Pro (Optional) ASTM HT-N, RESISTO SA SMOOTH PLY Deck / D41, Elastocol Stick, plywood, 056 or Southern Yellow Pine 40, Lastobond Shieid HT, sheathing Elastocol Stick Zero (SYP) Lastobond Pro HT-S, ASTM D41 structural concrete EnviroShield, Lastobond TU HT, Insulation (Optional) Elastocol Dens Deck Prime or SECUROCK Gypsum - Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond Self Stick Zero Fiber Roof Board ECO, RESISTO LB1236, Grip -Rite adhering Eave & Valley Protector, TopShield ICE & WATER Base Sheet (Optional) Elastocol A5TM D226, Type II felt or Modified Sopra- DEFENDER, RFSISTO LB1244, Stick Zero G Lastobond Smooth Seal HT or Grip -Rite Smooth Seal HT (Optional) ASTM Deck / D41 pl wood Y sheathing ASTM D41 structural concrete Colphene FR GR self adhering Insulation (Optional) Elastocol Dens Deck Prime or SECUROCK Gypsum - Stick Zero Fiber Roof Board Base Sheet (Optional) Elastocol ASTM D226, Type II felt or Modified Sopra- Stick Zero G RESISTO LB1236, Grip -Rite Eave self Existing EXTERIOR Existing sand -surfaced, glass -fiber surfaced, & Valley Protector or TopShield adhering substrate PRIMER PRIMER mineral -surfaced or film -surfaced roof ICE & WATER DEFENDER underlayment* * Final acceptance of any existing substrate in a reroof (tear -off) installation is at the discretion of the installer and the Authority Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive RESISTO LB1236, Grip -Rite Eave & Valley Protector or TopShield lCF & WATER DEFENDER self -adhering uoderloyments, contact RESISTO technical support. 5.7.1 Soprema recommends priming with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof cover is not slated for installation within 24 hours. 5.7.2 Soprema requires tongue -and -groove board decking be covered with plywood or OSB prior to installation of the self -adhering underlayment Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performunce NEMO ETC, LLC Evaluation Report S18010.06.09-R18 Certificate of Authorizarion #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-RZO Soprema Roof Underlayments Revision IS: 09/17/2020 Page 5 of 8 5.8 Attachment Limitations: NNEMOletc. 5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with the manufacturer's installation instructions, but -for mechanically attached underlayments or base sheets - not less than FBC 1507.1.1 or R905.1.1. 5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation instructions, but - for mechanically attached base sheets - not less than: • FRSA/TRI Florida Nigh Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1(for Two -Ply Asphalt Applied Hot Mop Underlayment) or Section 5.8.3 herein (for other underlayment systems). 5.8.3 Wind Resistance for Underla ment Systems in Tile Roof Applications: The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI Florida Nigh Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. The Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). S.83.1 Direct -to -Deck: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida Nigh Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. #1 Maximum Desi n Pressure = -45.0 sf: Deck: Min. 1S/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) Elastocol Stick, Elastocol Stick Zero or RESISTO EXTERIOR PRIMER Underlayment: Lastobond TU HT, self -adhered. #2 Maximum Design Pressure =-67.5 osf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: Elastocol Stick Zero Underlayment: Lastobond TU HT, self -adhered. 43 Maximum Desi n Pressure - -120.0 sf: Deck: Min. 15/32-inch APA-rated CDX plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) RESISTO EXTERIOR PRIMER Base Ply: RESISTO SA SMOOTH PLY 40, self -adhered. Underlayment: Lastobond TU HT, self -adhered. 44 Maximum Design Pressure = -150.0 psf: Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) RESISTO EXTERIOR PRIMER Underlayment: Lastobond TU HT, self -adhered. 45 All other direct -deck, adhered underlayment systems beneath the roof systems carry a Maximum Design Pressure of -45 psf. NEIVIO ETC, LLC Certificote of Authnrizotian #324SS 7"' EDITION (2020) FBC NON-HVHZ EVALUATION Soprema Roof Underlayments Evaluation Report S18010.06.09-1118 FL2569-R20 Revision IS: 09/17/2020 Page 6 of 8 5.8.3.2 Mechanically -Attached Base Sheet: ON EMO I etc. The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida Nigh Wind Concrete and Clay hoof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Alternatively, the maximum designs pressure for the selected assembly shall meet or exceed at least the Zone 1 design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Applications Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for enhancements. 46 Maximum Design Pressure = -60.0 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet; Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC 1517.5.2) spaced 6- inch o.c. at the 4-inch laps and 6-inch o.c. in three (3), equally spaced rows in the center of the sheet. Underlayment: Lastobond TU HT, self -adhered 5.8.4 For use over insulation or coverboard and under mechanically attached prepared roof coverings, underlayment attachment shall be in accordance with the manufacturer's installation instructions and attachment of the insulation or coverboard shall be in accordance with the prepared roof covering manufacturer's Product Approval. 5.9 Exposure Limitations; TABLE 3: ExPOSuftE LIMITATIONS Underlayment Prepared Roof Cover Maximum Installation Type Exposure (days) Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco, RESISTO 1-131236, Grip- Mechanically Rite Eave & Valley Protector, TopShield fCE & WATER DEFENDER or RESISTO LB1244 attached 30 Lastobond TU HT Adhesive -set the roof 30 system Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Mechanically Lastobond Pro HT-5, Fnviro5hield, Lastobond Smooth Seal HT or Grip -Rite Smooth Seal HT attached 90 Lastobond TU HT or Colphene FR GR Mechanically 180 attached 5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TARLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Slope Flat Max. 10-tile stack 6:12 Lugged Max. 10-tile static 5:12 Max. 10-tile stack (bottom 2-tile stack shall be inverted, followed by 8 tiles high on slope, as shown below) 6:12 Lastobond TU H7 Lugged d NEMO ETC, LLC Cerirficate of Authorization #32955 7n" EDITION 12020) FIX NON-HVHZ EVALUATION SDprema Roof Underlayments Evaluation Report S18010-06.09-1118 FL2569-R20 Revision 18: 09/17/2020 Page 7 of 8 ONEMOJetc. TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Slope Colphene FR GR Flat Max. to -tile stack 5;1Z Lugged Max. 10-tile stack 6:12 NSTALILATIICIN*,'� 6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.2.1 Installation of RESISTO L131236, Grip -Rite Eave & Valley Protector or TopShield ICE & WATER DEFENDER self - adhering underlayment in a reroof (tear -off) application atop an existing underlayment (per Table 2) requires priming of the existing substrate with RESISTO EXTERIOR PRIMER. Final acceptance of any existing substrate in a reroof (tear -off) installation is at the discretion of the installer and the Authority Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive RESISTO LB1236, Grip -Rite Eave & Valley Protector or TopShield ICE & WATER DEFENDER self -adhering underlayments, contact RESISTO technical support. 6.3 Lastobond TU HT, Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, EnviroShield, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond Eco, Lastobond Smooth Seal HT, Grip -Rite Smooth Seal HT, RESISTO LB1236, Grip -Rite Eave & Valley Protector, TopShield ICE & WATER DEFENDER, RESISTO LB1244 or Colphene FR GR: b.3,1 Non- IfleApplications: Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R90S.1.1.3 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. When installed over a mechanically attached base sheet of FBC Approved ASTM D226, Type II felt the base sheet shall be fastened in accordance with FBC 1507.1.1 or R905.1.1. 6.3.2 Tile Applications; Limited to Lastobond TU HT or Colphene FR GR. Shall be installed in compliance with the requirements for Self -Adhered Membrane set forth in FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition and the manufacturer's installation instructions. Refer to Section 5.8.3 herein for attachment limitations. Refer to Table 4 herein for tile staging limitations. Refer to7.8.2 for attachment limitations. Refer to Table 4 for the staging limitations. • • As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. ANUFACTUiIING PLAN Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61GZO-3 CIA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. UL, LLC—QUA9625; (314) 578-3406; k.chancellor@u5ml.com - END OF EVALUATION REPORT - NEMO ETC, LLC Evaluation Report S18010.06.09-R18 CeNifitote of Authorization N32455 7;" EDITION (20201 FBC NON-HVH2 EVALUATION FL2569-R20 Soprema Roof Underlayments Revision 18: 09/17/2020 Page 8 of 8