Loading...
HomeMy WebLinkAboutEvaluation Report; Static Flood VentsDIVISION: 08 00 00—OPENINGS SECTION: 08 95 43—VENTS/FOUNDATION FLOOD VENTS REPORT HOLDER: FLOOD SOLUTIONS, LLC ONE INDUSTRIAL PARK DRIVE, BUILDING 27 PELHAM, NEW HAMPSIRE 03076 EVALUATION SUBJECT: STATIC FLOOD VENTS ICC ICC ICC ��� cQ"— ED Look for the trusted marks of Conformity! "2014 Recipient of Prestigious Western States Seismic Policy Council (WSSPQ Award in Excellence" iN(fRNA({QHA+_ ASubsidiaryof soaecooecir ICGES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a tnum recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as v�iec vmc na to any finding or other matter in this report, or as to any product covered by the report. °° °°°oda a°°' A" ". Copyright m 2018 ICC Evaluation Service, LLC. All rights reserved. IMES Evaluation Report ESR-3760 Reissued March 2016 Revised January 2018 This report is subject to renewal March 2018. www.icc-es.org I (800) 423-6587 I (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 08 00 00—OPENINGS Section: 08 95 43—Vents/Foundation Flood Vents REPORT HOLDER: FLOOD SOLUTIONS, LLC ONE INDUSTRIAL PARK DRIVE BUILDING 27 PELHAM, NEW HAMPSHIRE 03076 (800)326.9775 www.floodsolutions.com i nfogbfloodso lutions. c o m EVALUATION SUBJECT: STATIC FLOOD VENTS 1.0 EVALUATION SCOPE Compliance with the following codes: ■ 2018, 2015, 2012 and 2009 International Building Codee ■ 2018, 2015, 2012 and 2009 International Residential Code® Property evaluated: Water flow 2.0 USES Flood Solutions' static flood vents are used to provide for the equalization of hydrostatic flood forces on exterior walls. 3.0 DESCRIPTION 3.1 General: Flood Solutions' static flood vents are engineered, permanently open flood vents with no moving parts that automatically allow flood waters to enter and exit enclosed areas. The vents are constructed of aluminum and available in four models. See Table 1 for model designations and sizes. See Figure 1 for illustrations of the flood vents. 3.2 Engineered Opening: The Flood Solutions static flood vents comply with the design principle noted in Section 2.6.2.2 of ASCE/SEI 24 for a rate of rise and fall of 5 feet per hour (0.423 mm/s). In order to comply with the engineered opening requirement of ASCE/SEI 24, the static flood vents must be installed in accordance with Section 4.0 of this report. womm Flood Solutions' static flood vents may be used to supply natural ventilation for under -floor ventilation. See Table 1 for net free area for under -floor ventilation provided by each of Flood Solutions' static flood vents. 4.0 DESIGN AND INSTALLATION The Flood Solutions static flood vents are designed to be installed into walls or doors of existing or new construction from the exterior side. Installation of the vents must be in accordance with the manufacturer's instructions, the applicable code and this report. In order to comply with the engineered opening design principle noted in Section 2.6.2.2 of ASCE/SEI 24, the vents must be installed as follows: • With a minimum of two opening on different sides of each enclosed area. • With a minimum of one vent for the square footage of enclosed area noted in Table 1. • Below the base flood elevation. • With the bottom of the vent located a maximum of 12 inches (305 mm) above grade. 5.0 CONDITIONS OF USE The static flood vents described in this report comply with, or are a suitable alternative to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 The static flood vents must be installed in accordance with this report, the applicable code and the manufacturer's installation instructions. In the event of a conflict, the instuctions in this report govern. 5.2 The static flood vents must not be used in the place of "breakaway walls" in coastal high hazard areas, but are permitted for use in conjunction with breakaway walls in other areas. 6.0 EVIDENCE SUBMITTED 6.1 Manufacturer's descriptive literature and installation instructions. 6.2 Detail drawings. 6.3 Engineering calculations in accordance with ASCE/SEI 24. 6.4 Quality documentation in accordance With the ICC-ES Acceptance Criteria for Quality Documentation (AC10), dated June 2014. ICC-ES rvoluation Reports are nor to be construed as represonang aesvhebcs or any other ouribules non specifically addressed, nor are they lobe c,inaraed per' as an endorsementsofthe.nubject of the report or a recommendation Jbr its use. There is no warranq, by ICC Evaluation Service, LLC, express or implied, ns v l�J to anyJlndig or other moiler in Ills report, arcsnto any product covered by the report Rv.''n .,. Copyright 0 2018 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 3 ESR-3760 I Most Widely Accepte% tl Trusted Page 2 of 3 7.0 IDENTIFICATION manufacturer's name (Flood Solutions), the model The Flood Solutions static flood vents recognized in this number, and the evaluation report number (ESR-3760). report must be identified by a label bearing the TABLE 1—FLOOD SOLUTIONS STATIC FLOOD VENTS VENT SIZE ROUGH OPENING SIZE ENCLOSED NET FREE AREA MODEL (Width x Height) (Width x Height) AREA COVERAGE (in) (in) (In) FS-1608 181/, x 10'/, 16 x 8 97 80.7 FS-1616 18 /, x 18% 16 x 16 191 158.2 FS-1412 - 17 x 14 /, 14'/, x 12 129 106.7 FS-1608-Hex�k; 18'/, x 10'/, 16 x 8 Ew 91.4 For SI: 1 inch = 25.4 mm; 1 ft = 304.8 mm 'Available for use as under -floor ventilation. FS-1412 FS-1616 FS-1608 FS-1608-HEX FIGURE 1—FLOOD SOLUTIONS STATIC FLOOD VENTS ICC-ES Evaluation Report ESR-3760 FBC Supplement Reissued March 2016 Revised January 2018 This report is subject to renewal March 2018. www.icc-es.oro 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 08 00 00—OPENINGS Section: 08 95 43—Vents/Foundation Flood Vents REPORT HOLDER: FLOOD SOLUTIONS, LLC ONE INDUSTRIAL PARK DRIVE BUILDING 27 PELHAM, NEW HAMPSHIRE 03076 (800)325-9775 www.floodsolutions.com infoaflood sol u ti o n s.com EVALUATION SUBJECT: STATIC FLOOD VENTS 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that Flood Solutions' flood vents, recognized in ICC-ES master evaluation report ESR-3760, have also been evaluated for compliance with the codes noted below. Applicable code editions: ■ 2017 Florida Building Code —Building ■ 2017 Florida Building Code —Residential 2.0 CONCLUSIONS The Flood Solutions flood vents, described in Sections 2.0 through 7.0 of the master evaluation report ESR-376 , comply with the Florida Building Code —Building and the Florida Building Code —Residential, provided the design and installation are in accordance with the 2015 International Building Code® provisions noted in the master report. Use of the Flood Solutions' flood vents has also been found to be in compliance with the High -Velocity Hurricane Zone provisions of the Florida Building Code —Building and the Florida Building Code —Residential. For products falling under Florida Rule 9N-3, verification that the report holder's quality assurance program is audited by a quality assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the responsibility of an approved validation entity (or the code official when the report holder does not possess an approval by the Commission). This supplement expires concurrently with the master report, reissued March 2016, revised January 2018. IC'C-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not speaficahp addressed, nor are they to be coninn ed as an endorsement ajthe subject o'the report or a recommendation for its use. There is no warranty by ICC Eva/union Service, LLC, expresx nr rmplrad ns s�� to any findtog or other matter in this report, or as to any product covered by the report, Copyright 0 20181CC Evaluation Service, LLC. All rights reserved. Page 5 of 3