HomeMy WebLinkAboutNOA; Georgia Pacific Vinyl Siding and Vented SoffitM IAM I•DADE NWMI-DARE COUNTY PRODUCT CONTROL SECTION -11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE _ www.miamidadR.gov/economy -e O;= , Georgia Pacific, Div. of Ply Gem Industries, Inc. 303 W. Major JAN 0 2 Kearney, MO 64060 ST. Lucie County, Permitting SCOPE' This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER- Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than -Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify,' or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Georgia Pacific Vinyl Siding and Vented Soffit APPROVAL DOCUMENT: Drawing No. 12-0829.13, titled "Installation Design Drawing for Vinyl Siding/Soffit", sheets 1 and 2 of 2, dated 01/25/2013, prepared by the manufacturer, signed and sealed by Allen N. Reeves, P.E. on 10/27/2017, bearing the Miami -Dade County Product Control renewal stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. NIISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each piece shall bear a permanent label marked at not more than 4' o.c. with the manufacturer's name or logo, city, state, and following statement: "Miami -Dade County Product Control Approved" and per FBC 1709:.10.2 and 1709.10.3 on Soffits. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer'or its distributors and shall be available for inspection at the job site at the request of the Building Official. �• This NOA renews NOA # 17-1107.06 and consists of this page 1 and evidence pages E-1ar ,bas well as approval document mentioned above. i ®� y The submitted documentation was reviewed by Carlos M. Utrera, P.E. NOA No.18-0808.02 MIAMFDADE counrrr Expiration Date: October 31, 2022 Approval Date: September 20, 2018 Page 1 Georgia Pacific, Div. of Ply Gem Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. Evidence submitted' under previous NOA's A. DRAWINGS "Evidence submitted under NOA #12-0829.13" 1. Drawing No.12-0829.13, titled "Installation Design Drawing for Vinyl Siding/Soffit", sheets 1 and 2 of 2, dated 01/25/2013, prepared by the manufacturer, signed and sealed by Allen N. Reeves, P.E. B. TESTS "Submitted under NOA # 03-1017.01 " Laboratory Report Test Date Signature 1. 01-44749.02 TAS 202 & 203 03/10/04 J. A. Reed, P.E. 2. 01-44739.02 TAS 202 & 203 03/10/04 J. A. Reed, P.E. 3. 01-44750.02 TAS 202 & 203 03/10/04 J. A. Reed, P.E. 4. 50437.01-106-18 ASTM G155 12/06/04 J. A. Reed, P.E. 5. 50437.01-106-18 ASTM D638 12/06/04 J. A. Reed, P.E. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. None. , F. STATEMENTS "Evidence submitted under NOA #12-0829.13" 1. Statement letter of code conformance to' 2010 FBC issued by H.R. Engineering, Inc., dated 01/30/2013, signed and sealed by Allen N. Reeves, P.E. "Submitted under NOA # 08-0429.11" 2. Statement letter of no financial interest issued by H.R. Engineering, Inc., dated 05/19/2008, signed and sealed by Allen N. Reeves, P.E. 3. Private label agreement letter dated 08/14/2002. 4 Carlos M. Utrera, P.E. Product Control Examiner NOA No. 18-0808.02 Expiration Date: October 31, 2022 Approval Date: September 20, 2018 E-1 Georgia Pacific, Div. of Ply Gem Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. Evidence submitted under NOA #17-1107.06 A. DRAWINGS 1. Drawing No.'12-0829.13, titled "Installation Design Drawing for Vinyl Siding/Soffit", sheets 1 and 2 of 2, dated 01/25/2013, prepared by the manufacturer, signed and sealed by Allen N. Reeves, P.E. on 10/27/2017. B. TESTS 1. Test reports on 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of Variform Contractors Choice D5 Vinyl Siding, prepared by Intertek/ATI, Test Report No. H5091.01-109-18, dated 11/29/2017, signed and sealed by Joseph A. Reed, P.E. 2. Test reports on 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of Variform Model 145 Standard Double 5 Vinyl Soffit, prepared by Intertek/ATI, Test Report No. H5171.01-109-18, dated 10/31/2017, signed and sealed by Joseph A. Reed, P.E. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS 1. Statement letter of code conformance to the 5t' edition (2014) and 6t' edition (2017) FBC issued by H.R. Engineering, Inc., dated 11/01/2017, signed and sealed by Allen N. Reeves, P.E. 2. Testing (TASi 100(A)) contract letter issued by Intertek/ATI, dated 11/02/20.17, signed by Vicki L. McElwain. Carlos M. Utrera, P.E. Product Control Examiner NOA No. 18-0808.02 Expiration Date: October 31, 2022 Approval Date: September 20, 2018 E-2 Georgia Pacific, Div. of Ply Gem Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 3. New evidence submitted A. DRAWINGS 1. None. B. TESTS "Submitted under NOA # 18-0808.01" 1. Test report on Wind Driven Rain Resistance Test per FBC TAS 100(A)-95 of the Triple 3-1/3" perforated soffit, prepared by Intertek/ATI, Test Report No. G8989.01-109-18, dated 02/14/2018, signed and sealed by Joseph A. Reed, P.E. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS 1. Statement letter of code conformance to the 601 edition (2017) FBC and of no financial interest issued by H.R. Engineering, Inc., dated 06/25/2018, signed and sealed by Allen N. Reeves, P.E. wi£ri r Carlos A Utrera, P.E. Product Control Examiner NOA No. 18-0808.02. Expiration Date: October 31, 2022 Approval Date: September 20, 2018 E-3 �m OALVANm3D RoomimNAM Va' M1ANK MA., 316' tMW 13111„ X 1.1lz' LONG, TFMOMH NAM tUa 1 MiAND BATTEN AT iMsltLOCKS .S3 i8X2°WOODS0REW,BA'rmTO ^ ' ROORPRAWMG,?A'MLY.9yACINti 1 PRODUCT RENEWED as complying with the Florida Building Code .-No. 18-0806.02 Expiration D 1013112022 sy Miami-Dade/Product Control � PASCiAaA • a a 0 0 0' a de 0 O a v1Ntt, o 0 lA2BATYRN D, O 21 WALL ��:ff 1 a4' V1�N1 r /2n /Z„� ' ROO@OVERHAND 7'i2 LIZ qn LA - PRODUCT CIZ OSS. SI;CTiON ti RENEWED as com lylnp with the Florida Building Code DAl1Rll' i0 NAII NOA-No. 1T-11Q7.D[i NAII 9ACI$N BA11'[zN ExplrationDj�eiDl31/2D18 By---_D BDNPTf I Miami -I d ProductControl�r, pl =� '„ I. sOPvl7' so I 4 ``a,�`uPIN niRl,gn�' III+ HI F wHl WOOAROOPFRAbDND�N�'E,V a4"MA,Y]MIBg3PAc..tt40 e`' ';.` s�•,cc�p'`: FAAVE LONGITi11NINAI,• SECTIONS L , Ne.10364 ALLMi N.RBEV88JML MUCPURALL�AI(t1NI §!t FASCIA ,'',fl SUO,1t1,A1 Ark����0 G+-/!c /1xrvt4� MRMALICIMM 19$54 - ay dcr, a o17 ' Qeorela Pacide Td108e Division of Ply Gem Induslrlae, Inc, 303 W. major 1 fl a Ilkerney, iND 04060 ts2WdanRATr&fSjWS INSTALLATION DESIGN ORB M soDT111ZRNPINE DRA MG FOR, VINYL SOI-'kPP D ANR DATE: 25]AN.2013 EA.VE. FRA11 M ISOMiiTMC 1rM-W rl A rite H12 0829.13 No. Revisions - bofe SCALE VARIES SHEET 2OF2 APPROVIM MODUS CONF GUttAMON EXPOS INCIMS THICKNESS -.001 DESI N PRESSURE NIIT MES AREA ISO Tr3Plo4' 12 0,035" +/-3333 0 151 Trl rlo 4" 12 0.035" W-33.7 14.34 152 rl 1e 4° 12 0.035" +/-33.9 q,211 L 0 Doubles" l0 0.044" *10.0 0 141 Doubles" 10 MUM 6.20 14 ouble5" 10 f40.0 0 145 Don e5 10 fO.O4 f40.0 620 351 Be edT' 1 *40.0 0 ]98 B7 y {O.0 8. 6