HomeMy WebLinkAboutNOA; Georgia Pacific Vinyl Siding and Vented SoffitM IAM I•DADE NWMI-DARE COUNTY
PRODUCT CONTROL SECTION
-11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE _ www.miamidadR.gov/economy
-e O;= ,
Georgia Pacific, Div. of Ply Gem Industries, Inc.
303 W. Major JAN 0 2
Kearney, MO 64060
ST. Lucie County, Permitting
SCOPE'
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER-
Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority
Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than -Miami Dade County) reserve the right
to have this product or material tested for quality assurance purposes. If this product or material fails to
perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may
immediately revoke, modify,' or suspend the use of such product or material within their jurisdiction. RER
reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control
Section that this product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code, including the High Velocity Hurricane Zone.
DESCRIPTION: Georgia Pacific Vinyl Siding and Vented Soffit
APPROVAL DOCUMENT: Drawing No. 12-0829.13, titled "Installation Design Drawing for Vinyl
Siding/Soffit", sheets 1 and 2 of 2, dated 01/25/2013, prepared by the manufacturer, signed and sealed by
Allen N. Reeves, P.E. on 10/27/2017, bearing the Miami -Dade County Product Control renewal stamp with
the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section.
NIISSILE IMPACT RATING: Large and Small Missile Impact Resistant
LABELING: Each piece shall bear a permanent label marked at not more than 4' o.c. with the
manufacturer's name or logo, city, state, and following statement: "Miami -Dade County Product Control
Approved" and per FBC 1709:.10.2 and 1709.10.3 on Soffits.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer'or its distributors and
shall be available for inspection at the job site at the request of the Building Official. �•
This NOA renews NOA # 17-1107.06 and consists of this page 1 and evidence pages E-1ar ,bas
well as approval document mentioned above. i ®� y
The submitted documentation was reviewed by Carlos M. Utrera, P.E.
NOA No.18-0808.02
MIAMFDADE counrrr Expiration Date: October 31, 2022
Approval Date: September 20, 2018
Page 1
Georgia Pacific, Div. of Ply Gem Industries, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
1. Evidence submitted' under previous NOA's
A. DRAWINGS "Evidence submitted under NOA #12-0829.13"
1. Drawing No.12-0829.13, titled "Installation Design Drawing for Vinyl Siding/Soffit",
sheets 1 and 2 of 2, dated 01/25/2013, prepared by the manufacturer, signed and sealed
by Allen N. Reeves, P.E.
B. TESTS "Submitted under NOA # 03-1017.01 "
Laboratory Report
Test
Date
Signature
1.
01-44749.02
TAS 202 & 203
03/10/04
J. A. Reed, P.E.
2.
01-44739.02
TAS 202 & 203
03/10/04
J. A. Reed, P.E.
3.
01-44750.02
TAS 202 & 203
03/10/04
J. A. Reed, P.E.
4.
50437.01-106-18
ASTM G155
12/06/04
J. A. Reed, P.E.
5.
50437.01-106-18
ASTM D638
12/06/04
J. A. Reed, P.E.
C. CALCULATIONS
1.
None.
D. QUALITY ASSURANCE
1.
Miami -Dade Department of Regulatory and Economic Resources (RER)
E. MATERIAL CERTIFICATIONS
1.
None.
,
F. STATEMENTS "Evidence submitted under NOA #12-0829.13"
1. Statement letter of code conformance to' 2010 FBC issued by H.R. Engineering, Inc.,
dated 01/30/2013, signed and sealed by Allen N. Reeves, P.E.
"Submitted under NOA # 08-0429.11"
2. Statement letter of no financial interest issued by H.R. Engineering, Inc., dated
05/19/2008, signed and sealed by Allen N. Reeves, P.E.
3.
Private label agreement letter dated 08/14/2002.
4
Carlos M. Utrera, P.E.
Product Control Examiner
NOA No. 18-0808.02
Expiration Date: October 31, 2022
Approval Date: September 20, 2018
E-1
Georgia Pacific, Div. of Ply Gem Industries, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
2. Evidence submitted under NOA #17-1107.06
A. DRAWINGS
1. Drawing No.'12-0829.13, titled "Installation Design Drawing for Vinyl Siding/Soffit",
sheets 1 and 2 of 2, dated 01/25/2013, prepared by the manufacturer, signed and sealed
by Allen N. Reeves, P.E. on 10/27/2017.
B. TESTS
1. Test reports on 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
2) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked -up drawings and installation diagram of Variform Contractors
Choice D5 Vinyl Siding, prepared by Intertek/ATI, Test Report No.
H5091.01-109-18, dated 11/29/2017, signed and sealed by Joseph A. Reed, P.E.
2. Test reports on 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
2) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked -up drawings and installation diagram of Variform Model 145
Standard Double 5 Vinyl Soffit, prepared by Intertek/ATI, Test Report No.
H5171.01-109-18, dated 10/31/2017, signed and sealed by Joseph A. Reed, P.E.
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. Miami -Dade Department of Regulatory and Economic Resources (RER)
E. MATERIAL CERTIFICATIONS
1. None.
F. STATEMENTS
1. Statement letter of code conformance to the 5t' edition (2014) and 6t' edition (2017)
FBC issued by H.R. Engineering, Inc., dated 11/01/2017, signed and sealed by Allen
N. Reeves, P.E.
2. Testing (TASi 100(A)) contract letter issued by Intertek/ATI, dated 11/02/20.17, signed
by Vicki L. McElwain.
Carlos M. Utrera, P.E.
Product Control Examiner
NOA No. 18-0808.02
Expiration Date: October 31, 2022
Approval Date: September 20, 2018
E-2
Georgia Pacific, Div. of Ply Gem Industries, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
3. New evidence submitted
A. DRAWINGS
1. None.
B. TESTS "Submitted under NOA # 18-0808.01"
1. Test report on Wind Driven Rain Resistance Test per FBC TAS 100(A)-95 of the
Triple 3-1/3" perforated soffit, prepared by Intertek/ATI, Test Report No.
G8989.01-109-18, dated 02/14/2018, signed and sealed by Joseph A. Reed, P.E.
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. Miami -Dade Department of Regulatory and Economic Resources (RER)
E. MATERIAL CERTIFICATIONS
1. None.
F. STATEMENTS
1. Statement letter of code conformance to the 601 edition (2017) FBC and of no financial
interest issued by H.R. Engineering, Inc., dated 06/25/2018, signed and sealed by
Allen N. Reeves, P.E.
wi£ri r
Carlos A Utrera, P.E.
Product Control Examiner
NOA No. 18-0808.02.
Expiration Date: October 31, 2022
Approval Date: September 20, 2018
E-3
�m
OALVANm3D RoomimNAM
Va' M1ANK MA., 316' tMW 13111„ X
1.1lz' LONG, TFMOMH NAM tUa 1
MiAND BATTEN AT iMsltLOCKS
.S3
i8X2°WOODS0REW,BA'rmTO ^ '
ROORPRAWMG,?A'MLY.9yACINti 1
PRODUCT RENEWED
as complying with the Florida
Building Code
.-No. 18-0806.02
Expiration D 1013112022
sy
Miami-Dade/Product Control
�
PASCiAaA
•
a a
0
0 0'
a de
0 O a
v1Ntt, o 0
lA2BATYRN D, O
21
WALL ��:ff 1
a4' V1�N1 r /2n /Z„�
' ROO@OVERHAND
7'i2 LIZ qn
LA -
PRODUCT CIZ OSS. SI;CTiON
ti
RENEWED
as com lylnp with the Florida
Building Code DAl1Rll' i0 NAII
NOA-No. 1T-11Q7.D[i NAII 9ACI$N BA11'[zN
ExplrationDj�eiDl31/2D18
By---_D BDNPTf I
Miami -I d ProductControl�r, pl =� '„ I. sOPvl7' so I 4
``a,�`uPIN niRl,gn�' III+ HI F wHl
WOOAROOPFRAbDND�N�'E,V
a4"MA,Y]MIBg3PAc..tt40 e`' ';.` s�•,cc�p'`: FAAVE LONGITi11NINAI,• SECTIONS
L , Ne.10364
ALLMi N.RBEV88JML MUCPURALL�AI(t1NI §!t
FASCIA ,'',fl SUO,1t1,A1 Ark����0 G+-/!c /1xrvt4� MRMALICIMM 19$54
- ay dcr, a o17 ' Qeorela Pacide Td108e Division of Ply Gem Induslrlae, Inc,
303 W. major
1 fl a Ilkerney, iND 04060
ts2WdanRATr&fSjWS INSTALLATION DESIGN
ORB M soDT111ZRNPINE DRA MG FOR, VINYL SOI-'kPP
D ANR DATE: 25]AN.2013
EA.VE. FRA11 M ISOMiiTMC 1rM-W rl A rite H12 0829.13
No. Revisions - bofe SCALE VARIES SHEET 2OF2
APPROVIM
MODUS
CONF GUttAMON
EXPOS
INCIMS
THICKNESS
-.001
DESI N
PRESSURE
NIIT MES
AREA
ISO
Tr3Plo4'
12
0,035"
+/-3333
0
151
Trl rlo 4"
12
0.035"
W-33.7
14.34
152
rl 1e 4°
12
0.035"
+/-33.9
q,211
L 0
Doubles"
l0
0.044"
*10.0
0
141
Doubles"
10
MUM
6.20
14
ouble5"
10
f40.0
0
145
Don e5
10
fO.O4
f40.0
620
351
Be edT'
1
*40.0
0
]98
B7
y {O.0
8. 6