Loading...
HomeMy WebLinkAboutReview Comments'plenntaigt�DeYelopttlettt,Serviees, 8trildhtg ��Codc l7eg�t�ragctin Dr�ision' 230d;Vlrgtnfa Avenue t=®rE Ptaicce, EL=. 34992 PROPERTY INFORMATION Address: 10851 S Ocean Dr 139 City / State / Zip: Jensen Beach, FI 349: REVIEW COMMENTS Owner(s): Felice Giuliani 1 Parcel #: 4511-810-0146-000/3 Jurisdiction: SAINT LUCIE COUNTY - i Zoning: HIRD Lot#: Block: APPLICATION INFORMATION r Permit Number: 1910-0742 Stories: Automatic Sprinkler System? No Permit Type: BUILDING RESIDENTIAL RENOVATION CONTRACTOR INFORMATION Contractor Name: Fax Number: Business Name: Business Addr: Email: City / State / Zip: I REVIEWS AND COMMENTS Review Type Status Reviewed By Date Started Date Completed Date Released 4 DOCUMENTS. MISSING COMPLETE Deanna Givens 10/31/2019 10/31/2019 10/31/2019 Comment: FRONT COUNTER REVIEW COMPLETE Deanna Givens 10/31/2019 10/31/2019 10/31/2019 Comment: I NOTIFIED FOR PICK UP PENDING Comment: PE REVIEW COMMENTS (2) INCOMPLETE William Durden 12/3/2019 Comment: 12/03/2019 NOT SUBMITTED. I 11/15/2019 MANDATORY SOUL REPORT FOR ALL OF NEW SINGLE-FAMILY RESIDENCES IN NETTLES ISLAND. • PLEASE SUBMIT GEOTECHNICAL REPORT IN COMPLIANCE WITH R401 OF THE 2017 RESIDENTIAL BUILDING CODE. Comment: 12/03/2019 f NOT SUBMITTED. 11/15/2019 PLEASE SEE CHAPTER 3, SECTION 301, SUBSECTION R301.1 APPLICATION AND R3 01.1.1 ALTERNATIVE PROVISIONS. (STRUCTURE IS LOCATED IN A FLOOD ZONE ON A MAN-MADE ISLAND THAT REQUIRES FULL BORING FOR THE FOUNDATION REQUIREMENTS PLANS SHOW A WOOD FRAME STRUCTURE DIRECTLY ATTACHED TO A INCH OR 16 SLAB WITH NO FOOTINGS). PLEASE CLARIFY. Planning '& Development'Serviees 8uiiding &Godiftuiagora Division POO Virginia Avenue, +,Fort l3fame; FL 34992 REVIEW COMMENTS Comment: 12/03/2019 1. THE CORRECT WIND SPEED PER THE WIND CHART IS 163MPH. PLEASE CORRECT. 2. THE COMPONENT'S AND CLADDING DESIGN PRESSURE USED SEEM TO BE CALCULATED TO LOW FOR 160MPH, EXPOSURE D, WITH A HEIGHT EXPOSURE OF 15FT, AND 1.47 COEFFICIENT OF 1.47. PLEASE REVIEW THE DESIGN PRESSURES. 11/15/2019 WIND SPEED SPECIFIED ON PLANS IS INCORRECT. PLEASE SEE THE WIND SPEED MAP LOCATED ON THE ST. LUCIE COUNTY PERMITTING WEBSITE FOR A RISK CATEGORY TWO BUILDING. ACCORDING TO THE WIND SPEED MAP THE WIND SPEED SHOULD BE 164 MPH. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. Comment: 12/03/2019 SEE REVIEW COMMENTS ABOVE. 11/15I2019 WIND SPEED IS INCORRECT PLEASE REVIEW LINE 6 OF THE CERTIFICATION FOR DESIGN LOAD COMPLIANCE FORMS FOR THE CORRECT DESIGN PRESSURES. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. Comment: 12/03/2019 NO PRODUCT APPROVALS SUBMITTED FOR THE LOW SLOPE ROOF SYSTEM. THE LOW SLOPE ROOF LOOKS TO,BE LESS THAN 2:12 SLOPE, NOA NO.: 16-0510.23 SPECIFIES THE MATERIAL CANNOT BE INSTALLED ON A SLOPE LESS THAN 2:12. 11/15/2019 I NOA NUMBER 13 — 21125.02 SPECIFIES THAT THE ROOF PANEL APPROVED FOR ROOF SLOPE IS TO 12 OR GREATER PLANS SHOW A ROOF SLOPE LESS THAN 212 PLEASE SUBMIT PRODUCT APPROVAL OR ANY WAY FOR THE LOW SLOPE ROOF. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. Comment: 12/03/2019 NOA 18-0815.14 IS AN IN SWING DOOR ONLY, PLANS SHOW AN OUTSW ING DOOR. PLEASE SUBMIT THE CORRECT NOA OR PRODUCT APPROVAL. 11/15/2019 NOA 18 — 0815.14 IS FOR A SERIES 18 P, PDC/FIBERGLASS AND SWING GLAZED DOOR. PLAN SHOWS ALL EXTERIOR DOORS AS OUT SWING. PLEASE SUBMIT CORRECT PRODUCT APPROVAL. SEE SECTION 107 2017 FLORIDA BUILDING CODE. Comment: 12/03/2019 NOT SUBMITTED. PLEASE SHOW THE CALCULATIONS ON THE PLANS FOR THE VENTILATION. THE 11/15/2019 VENTILATION CANNOT BE CALCULATED WITH THE FLOOD VENTS. PLEASE CORRECT. PLEASE SUBMIT THE VENTILATION REQUIREMENTS FOR THE CRAWLSPACE. SEE SECTION 107 2017 FLORIDA BUILDING CODE. Comment: 12/03/2019' NOT SUBMITTED. PLEASE SHOW THE CALCULATIONS ON THE PLANS FOR THE VENTILATION. THE VENTILATION CANNOT BE CALCULATED WITH THE FLOOD VENTS. PLEASE CORRECT. 11/15/2019 SHOW ON ;THE PLANS AND CALCULATION FOR THE AIR VENTILATION OF THE CRAWLSPACE. SEE SECTION 107 2017 FLORIDA BUILDING CODE. Comment: 12/03/2019' NOT SUBMITTED. 11/15/2019 • PLEASE FURNISH ENERGY CALULATIONS AND MANUAL J IN ACCORDANCE WITH SECTIONS 402 AND 403 OF THE 2017 FLORIDA ENERGY CODE. NOTE ONLY; ENERGIES MUST HAVE ORIGINAL SIGNATURE OF PREPARER Comment: 12/03/2019 PLANS SHOW PRE ENGINEERED TRUSSES, PLEASE SUBMIT THE TRUSS PLACEMENT DRAWING AND THE 11/15/2019 TRUSS ENGINEERING. PLANS EXAMINER REVIEW Comment: ZONING REVIEW Comment: PLEASE SHOW ON THE PLANS THE TRUST FASTENING SCHEDULE. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE INCOMPLETE, William Durden 11/6/2019 12/3/2019 12/3/2019 APPROVED Lydia Galbraith 11/6/2019 11/19/2019 11/19/2019 Planning s 136velopment services, REVIEW COMMENTS Building &Codi Regufatiok Division 2300 Vhglrnla Avenue fort Pferce; OL U9182 Page 3 REVIEW COMMENTS Buildlltg 8 Code �egr�l�l�n�afi�i►i5il�l� i R v 01" AVEnue, I=olt P*cq;FL Page 1 PROPERTY INFORMATION i Address: 10851 S Ocean Dr 09 Owner(s): i Felice Giuliani City I State I Zip: Jensen Beach, FI 34957 Parcel #: 4511-810-0146-000/3 Jurisdiction: SAINT LUCIE COUNTY Zoning: HIRD Lot#: Block: APPLICATION INFORMATION f Permit Number: 1910-0742 Stories: Automatic Sprinkler System? No 1 Permit Type: BUILDING RESIDENTIAL RENOVATION CONTRACTOR INFORMATION Contractor Name: 7� _ Fax Number: Business Name:lyi Business Addr: Email: City I State I Zip: REVIEWS AND COMMENTS Review Tvue Status { Reviewed By Date Started Date Completed Date Released . DOCUMENTS MISSING fI COMPLETE Deanna Givens 10/31/2019 10/31/2019 10/31/2019 - Comment: I FRONT COUNTER REVIEW COMPLETE Deanna Givens 10/31/2019 10/31/2019 10/31/2019 Comment: NOTIFIED FOR PICK UP PENDING I Comment: PLANS EXAMINER REVIEW INCOMPLETE William Durden 11/6/2019 f Comment: MANDATORY SOUL REPORT FOR ALL OF NEW SINGLE-FAMILY RESIDENCES IN NETTLES ISLAND. 11/15/2019 • PLEASE SUBMIT GEOTECHNICAL REPORT IN COMPLIANCE WITH R401 OF THE 2017 RESIDENTIAL BUILDING CODE. Comment: PLEASE SEE CHAPTER 3, SECTION 301, SUBSECTION R301.1 APPLICATION AND R3 01.1.1 ALTERNATIVE PROVISIONS. (STRUCTURE IS LOCATED IN A FLOOD ZONE ON A MAN-MADE ISLAND THAT REQUIRES FULL 11/15/2019 BORING FOR THE FOUNDATION REQUIREMENTS PLANS SHOW A WOOD FRAME STRUCTURE DIRECTLY ATTACHED TO A4INCH OR 16 SLAB WITH NO FOOTINGS). PLEASE CLARIFY. Comment: WIND SPEED SPECIFIED ON PLANS IS INCORRECT. PLEASE SEE THE WIND SPEED MAP LOCATED ON THE 11/15/2019 ST. LUCIE COUNTY PERMITTING WEBSITE FOR A RISK CATEGORY TWO BUILDING. ACCORDING TO THE WIND SPEED MAP THE WIND SPEED SHOULD BE 164 MPH. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. Comment: WIND SPEED IS INCORRECT PLEASE REVIEW LINE 6 OF THE CERTIFICATION FOR DESIGN LOAD 11/15/2019 COMPLIANCE FORMS FOR THE CORRECT DESIGN PRESSURES. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING C ODE. Comment: NOA NUMBER 13 — 21125.02 SPECIFIES THAT THE ROOF PANEL APPROVED FOR ROOF SLOPE IS TO 12 OR 11/15/2019 GREATER PLANS SHOW A ROOF SLOPE LESS THAN 212 PLEASE SUBMIT PRODUCT APPROVAL OR ANY WAY FOR TV E LOW SLOPE ROOF. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. 'Awl -Planning & Development.Serrlces. i3ullding .& Code Re4ulaldon Division 2306,Virginia Avenue 'Fort Pierce,, FL. 34982 REVIEW COMMENTS Page 2 Comment: NOA 18 — 0815.14 IS FOR A SERIES 18 P, PDC/FIBERGLASS AND SWING GLAZED DOOR. PLAN SHOWS ALL 11/15/2019 EXTERIOR DOORS AS OUT SWING. PLEASE SUBMIT CORRECT PRODUCT APPROVAL. SEE SECTION 107 2017 FLORIDA BUILDING CODE. 11/15/2019 Comment: SUBMIT THE PRODUCT APPROVALS FOR THE FLOOD VENTS. SEE SECTION 322 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE. 11/15/2019 Comment: PLEASE SUBMIT THE VENTILATION REQUIREMENTS FOR THE CRAWLSPACE. SEE SECTION 107 2017 FLORIDA BUILDING CODE. 11/15/2019 Comment: SHOW ON THE PLANS THE CALCULATION FOR THE FLOOD VENT REQUIREMENTS. SEE SECTION 322 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE 11/15/2019 Comment: SHOW ON THE PLANS AND CALCULATION FOR THE AIR VENTILATION OF THE CRAWLSPACE. SEE SECTION 107 2017 FLORIDA BUILDING CODE. Comment: • PLEASE FURNISH ENERGY CALULATIONS AND MANUAL J IN ACCORDANCE WITH SECTIONS 402 AND 403 11/15/2019 OF THE 2017 FLORIDA ENERGY CODE. NOTE ONLY; ENERGIES MUST HAVE ORIGINAL SIGNATURE OF PREPARER 11/15/2019 Comment: PLEASE SHOW ON THE PLANS THE TRUST FASTENING SCHEDULE. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE 11/15/2019 Comment: PLEASE SHOW ON THE PLANS THE ROOF LAYOUT WITH ZONE REQUIREMENTS. SEE SECTION 107 2017 FLORIDA BUILDING CODE 11/15/2019 Comment: FRONT ENTRY TO NON-CONDJTIONED SPACE MUST BE FLOOD VENTED. SEE SECTION 322 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE. 11/15/2019 Comment: PLEASE SHOW ON THE PLANS THE ATTACHMENT METHOD FOR THE 4 X 4 POST AT THE PROPOSED ELEVATED DECK TO THE EXISTING FOUNDATION. SEE SECTION 107 2017 FLORIDA BUILDING CODE. Comment: PLEASE SHOW ON THE PLANS THE CORRECT ELEVATIONS STARTING WITH THE EXISTING ELEVATION OF 11/15/2019 THE SLAB AND THE GRADE TO BASE FLOOD ELEVATION TO MEAN ROOF HEIGHT. SEE SECTION 107 2017 FLORIDA BUILDING CODE. Comment: THE STRUCTURE WILL BE CONSIDERED AS A SUBSTANTIAL IMPROVEMENT TO THE EXISTING CONDITIONS. THE STRUCTURE MUST COMPLY WITH ALL CODES AND REGULATIONS MEETING THE REQUIREMENTS OF THE SUBSTANTIAL IMPROVEMENT FOR A STRUCTURE IN THE FLOOD ZONE. PLEASE 11/15/2019 SUBMIT DRAWINGS THAT CLEARLY SPECIFY AND SHOW THE STRUCTURE MEETING THE REQUIREMENTS OF THE 2017 FLORIDA EXISTING BUILDING CODE, 2017 FLORIDA RESIDENTIAL BUILDING CODE, FEMA REQUIREMENTS, AND THE LAND DEVELOPMENT CODE. 11/15/2019 Comment: IN ALL DOCUMENTS HAVE BEEN SUBMITTED FOR REVIEW ADDITIONAL COMMENTS MAY BE REQUIRED TO CORRECT ANY DEVIATION FROM THE CODES. ZONING REVIEW INCOMPLE t Lydia Galbraith 11/6/2019 11/7/2019 Comment: PROP SED STRUC RE IS NOT MEETING THE MIN. REQUIRED SETBACK OF VON THE LEFT SIDE (ST. LUCI COUNTY LAND EV. CODE CHAPTER 7.10.16 Q) \� Comment: THE PROPOSED REA DECK IS ENCROACHING IN THE MIN. REQUIRED 5' SETBACK. PL SE INDICATE PR POSED DECK ON SURVEY MEETING CODE. t \v STE S OR RAMPS FO ACCESS PURPOSES MAY BE ERECTED, BUT MAY NOT ENCROACH INTO ANY `\1 REQ IRED SIDE SET ACK. STEPS OR RAMPS MAY ENCROACH INTO THE FRONT OR REAR SETBACKS, IF NEC SSARY PROVI ED THAT THE STEPS OR RAMPS DO NOT OCCUPY MORE THAN TEN PERCENT (10%) 1/7/2019 OFT REQUIRE RONT OR REAR YARD UNLESS OTHERWISE APPROVED BY THE ST. LUCIE COUNTY BOAR OF ADJ TMENT IN ACCORDANCE WITH SECTION 10.01.00. STEPS MPS WHICH ENCROACH INTO FRONT OR REAR SETBACKS MAY NOT HAVE A LANDING WITH DIMENSION EXCESS OF FOUR (4) FEET BY FOUR (4) FEET WHERE SUCH LANDING ENCROACHES INTO THE REQUIRED ONT OR REAR SETBACK. THE ALLOWED ENCROACHMENT IN THE REAR SETBACK WILL BE 15 SF. 11/7 019 Comment: THE FINISHED FLOOR EVATION IS REQUIRED TO BE FLOODZONE + 1'. MIN.REQUIRED FLOOD ELEVATION IS 7'+ V= 8' 11/7/2019 Comment: PLEASE INDICATE ON TH SURVEY TWO PARKING SPACES OF EACH 8'X18'. 11/7/2019 Comment: THE SUBMITTED SURVEY 13 A COPY. PLEASE PROVIDE 2 SIGNED AND SEALED SURVEYS UPDATED WITH ABOVE COMMENTS.