PROPERTY INFORMATION
Address: 10851 S Ocean Dr 139
City / State / Zip: Jensen Beach, FI 349:
REVIEW COMMENTS
Owner(s):
Felice Giuliani
1
Parcel #: 4511-810-0146-000/3 Jurisdiction: SAINT LUCIE COUNTY -
i
Zoning: HIRD Lot#: Block:
APPLICATION INFORMATION
r
Permit Number: 1910-0742 Stories: Automatic Sprinkler System? No
Permit Type: BUILDING RESIDENTIAL RENOVATION
CONTRACTOR INFORMATION
Contractor Name: Fax Number:
Business Name:
Business Addr: Email:
City / State / Zip:
I
REVIEWS AND COMMENTS
Review Type Status Reviewed By Date Started Date Completed Date Released
4
DOCUMENTS. MISSING COMPLETE Deanna Givens 10/31/2019 10/31/2019 10/31/2019
Comment:
FRONT COUNTER REVIEW COMPLETE Deanna Givens 10/31/2019 10/31/2019 10/31/2019
Comment:
I
NOTIFIED FOR PICK UP PENDING
Comment:
PE REVIEW COMMENTS (2) INCOMPLETE William Durden 12/3/2019
Comment: 12/03/2019
NOT SUBMITTED.
I
11/15/2019 MANDATORY SOUL REPORT FOR ALL OF NEW SINGLE-FAMILY RESIDENCES IN NETTLES ISLAND.
• PLEASE SUBMIT GEOTECHNICAL REPORT IN COMPLIANCE WITH R401 OF THE 2017 RESIDENTIAL
BUILDING CODE.
Comment: 12/03/2019 f
NOT SUBMITTED.
11/15/2019 PLEASE SEE CHAPTER 3, SECTION 301, SUBSECTION R301.1 APPLICATION AND R3 01.1.1 ALTERNATIVE
PROVISIONS. (STRUCTURE IS LOCATED IN A FLOOD ZONE ON A MAN-MADE ISLAND THAT REQUIRES FULL
BORING FOR THE FOUNDATION REQUIREMENTS PLANS SHOW A WOOD FRAME STRUCTURE DIRECTLY
ATTACHED TO A INCH OR 16 SLAB WITH NO FOOTINGS). PLEASE CLARIFY.
Planning '& Development'Serviees
8uiiding &Godiftuiagora Division
POO Virginia Avenue,
+,Fort l3fame; FL 34992
REVIEW COMMENTS
Comment:
12/03/2019
1. THE CORRECT WIND SPEED PER THE WIND CHART IS 163MPH. PLEASE CORRECT.
2. THE COMPONENT'S AND CLADDING DESIGN PRESSURE USED SEEM TO BE CALCULATED TO LOW FOR
160MPH, EXPOSURE D, WITH A HEIGHT EXPOSURE OF 15FT, AND 1.47 COEFFICIENT OF 1.47. PLEASE
REVIEW THE DESIGN PRESSURES.
11/15/2019
WIND SPEED SPECIFIED ON PLANS IS INCORRECT. PLEASE SEE THE WIND SPEED MAP LOCATED ON THE
ST. LUCIE COUNTY PERMITTING WEBSITE FOR A RISK CATEGORY TWO BUILDING. ACCORDING TO THE
WIND SPEED MAP THE WIND SPEED SHOULD BE 164 MPH. SEE SECTION 107 OF THE 2017 FLORIDA
BUILDING CODE.
Comment:
12/03/2019
SEE REVIEW COMMENTS ABOVE.
11/15I2019
WIND SPEED IS INCORRECT PLEASE REVIEW LINE 6 OF THE CERTIFICATION FOR DESIGN LOAD
COMPLIANCE FORMS FOR THE CORRECT DESIGN PRESSURES. SEE SECTION 107 OF THE 2017 FLORIDA
BUILDING CODE.
Comment:
12/03/2019
NO PRODUCT APPROVALS SUBMITTED FOR THE LOW SLOPE ROOF SYSTEM. THE LOW SLOPE ROOF
LOOKS TO,BE LESS THAN 2:12 SLOPE, NOA NO.: 16-0510.23 SPECIFIES THE MATERIAL CANNOT BE
INSTALLED ON A SLOPE LESS THAN 2:12.
11/15/2019
I
NOA NUMBER 13 — 21125.02 SPECIFIES THAT THE ROOF PANEL APPROVED FOR ROOF SLOPE IS TO 12 OR
GREATER PLANS SHOW A ROOF SLOPE LESS THAN 212 PLEASE SUBMIT PRODUCT APPROVAL OR ANY
WAY FOR THE LOW SLOPE ROOF. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE.
Comment:
12/03/2019
NOA 18-0815.14 IS AN IN SWING DOOR ONLY, PLANS SHOW AN OUTSW ING DOOR. PLEASE SUBMIT THE
CORRECT NOA OR PRODUCT APPROVAL.
11/15/2019
NOA 18 — 0815.14 IS FOR A SERIES 18 P, PDC/FIBERGLASS AND SWING GLAZED DOOR. PLAN SHOWS ALL
EXTERIOR DOORS AS OUT SWING. PLEASE SUBMIT CORRECT PRODUCT APPROVAL. SEE SECTION 107
2017 FLORIDA BUILDING CODE.
Comment:
12/03/2019
NOT SUBMITTED. PLEASE SHOW THE CALCULATIONS ON THE PLANS FOR THE VENTILATION. THE
11/15/2019
VENTILATION CANNOT BE CALCULATED WITH THE FLOOD VENTS. PLEASE CORRECT.
PLEASE SUBMIT THE VENTILATION REQUIREMENTS FOR THE CRAWLSPACE. SEE SECTION 107 2017
FLORIDA BUILDING CODE.
Comment:
12/03/2019'
NOT SUBMITTED. PLEASE SHOW THE CALCULATIONS ON THE PLANS FOR THE VENTILATION. THE
VENTILATION CANNOT BE CALCULATED WITH THE FLOOD VENTS. PLEASE CORRECT.
11/15/2019
SHOW ON ;THE PLANS AND CALCULATION FOR THE AIR VENTILATION OF THE CRAWLSPACE. SEE
SECTION 107 2017 FLORIDA BUILDING CODE.
Comment:
12/03/2019'
NOT SUBMITTED.
11/15/2019
• PLEASE FURNISH ENERGY CALULATIONS AND MANUAL J IN ACCORDANCE WITH SECTIONS 402 AND 403
OF THE 2017 FLORIDA ENERGY CODE. NOTE ONLY; ENERGIES MUST HAVE ORIGINAL SIGNATURE OF
PREPARER
Comment:
12/03/2019
PLANS SHOW PRE ENGINEERED TRUSSES, PLEASE SUBMIT THE TRUSS PLACEMENT DRAWING AND THE
11/15/2019
TRUSS ENGINEERING.
PLANS EXAMINER REVIEW
Comment:
ZONING REVIEW
Comment:
PLEASE SHOW ON THE PLANS THE TRUST FASTENING SCHEDULE. SEE SECTION 107 OF THE 2017
FLORIDA BUILDING CODE
INCOMPLETE, William Durden 11/6/2019 12/3/2019 12/3/2019
APPROVED Lydia Galbraith 11/6/2019 11/19/2019 11/19/2019
Planning s 136velopment services, REVIEW COMMENTS
Building &Codi Regufatiok Division
2300 Vhglrnla Avenue
fort Pferce; OL U9182
Page 3
REVIEW COMMENTS
Buildlltg 8 Code �egr�l�l�n�afi�i►i5il�l� i
R v 01" AVEnue,
I=olt P*cq;FL
Page 1
PROPERTY INFORMATION
i
Address: 10851 S Ocean Dr 09 Owner(s):
i Felice Giuliani
City I State I Zip: Jensen Beach, FI 34957
Parcel #: 4511-810-0146-000/3 Jurisdiction: SAINT LUCIE COUNTY
Zoning: HIRD Lot#: Block:
APPLICATION INFORMATION f
Permit Number: 1910-0742 Stories: Automatic Sprinkler System? No
1
Permit Type: BUILDING RESIDENTIAL RENOVATION
CONTRACTOR INFORMATION
Contractor Name: 7�
_ Fax Number:
Business Name:lyi
Business Addr:
Email:
City I State I Zip:
REVIEWS AND COMMENTS
Review Tvue
Status { Reviewed By Date Started Date Completed Date Released .
DOCUMENTS MISSING
fI
COMPLETE Deanna Givens 10/31/2019 10/31/2019 10/31/2019
- Comment:
I
FRONT COUNTER REVIEW
COMPLETE Deanna Givens 10/31/2019 10/31/2019 10/31/2019
Comment:
NOTIFIED FOR PICK UP
PENDING
I
Comment:
PLANS EXAMINER REVIEW
INCOMPLETE William Durden 11/6/2019
f
Comment:
MANDATORY SOUL REPORT FOR ALL OF NEW SINGLE-FAMILY RESIDENCES IN NETTLES ISLAND.
11/15/2019
• PLEASE SUBMIT GEOTECHNICAL REPORT IN COMPLIANCE WITH R401 OF THE 2017 RESIDENTIAL
BUILDING CODE.
Comment:
PLEASE SEE CHAPTER 3, SECTION 301, SUBSECTION R301.1 APPLICATION AND R3 01.1.1 ALTERNATIVE
PROVISIONS. (STRUCTURE IS LOCATED IN A FLOOD ZONE ON A MAN-MADE ISLAND THAT REQUIRES FULL
11/15/2019
BORING FOR THE FOUNDATION REQUIREMENTS PLANS SHOW A WOOD FRAME STRUCTURE DIRECTLY
ATTACHED TO A4INCH OR 16 SLAB WITH NO FOOTINGS). PLEASE CLARIFY.
Comment:
WIND SPEED SPECIFIED ON PLANS IS INCORRECT. PLEASE SEE THE WIND SPEED MAP LOCATED ON THE
11/15/2019
ST. LUCIE COUNTY PERMITTING WEBSITE FOR A RISK CATEGORY TWO BUILDING. ACCORDING TO THE
WIND SPEED MAP THE WIND SPEED SHOULD BE 164 MPH. SEE SECTION 107 OF THE 2017 FLORIDA
BUILDING CODE.
Comment:
WIND SPEED IS INCORRECT PLEASE REVIEW LINE 6 OF THE CERTIFICATION FOR DESIGN LOAD
11/15/2019
COMPLIANCE FORMS FOR THE CORRECT DESIGN PRESSURES. SEE SECTION 107 OF THE 2017 FLORIDA
BUILDING C ODE.
Comment:
NOA NUMBER 13 — 21125.02 SPECIFIES THAT THE ROOF PANEL APPROVED FOR ROOF SLOPE IS TO 12 OR
11/15/2019
GREATER PLANS SHOW A ROOF SLOPE LESS THAN 212 PLEASE SUBMIT PRODUCT APPROVAL OR ANY
WAY FOR TV E LOW SLOPE ROOF. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE.
'Awl
-Planning & Development.Serrlces.
i3ullding .& Code Re4ulaldon Division
2306,Virginia Avenue
'Fort Pierce,, FL. 34982
REVIEW COMMENTS
Page 2
Comment: NOA 18 — 0815.14 IS FOR A SERIES 18 P, PDC/FIBERGLASS AND SWING GLAZED DOOR. PLAN SHOWS ALL
11/15/2019 EXTERIOR DOORS AS OUT SWING. PLEASE SUBMIT CORRECT PRODUCT APPROVAL. SEE SECTION 107
2017 FLORIDA BUILDING CODE.
11/15/2019 Comment: SUBMIT THE PRODUCT APPROVALS FOR THE FLOOD VENTS. SEE SECTION 322 OF THE 2017 FLORIDA
RESIDENTIAL BUILDING CODE.
11/15/2019 Comment: PLEASE SUBMIT THE VENTILATION REQUIREMENTS FOR THE CRAWLSPACE. SEE SECTION 107 2017
FLORIDA BUILDING CODE.
11/15/2019 Comment: SHOW ON THE PLANS THE CALCULATION FOR THE FLOOD VENT REQUIREMENTS. SEE SECTION 322 OF
THE 2017 FLORIDA RESIDENTIAL BUILDING CODE
11/15/2019 Comment: SHOW ON THE PLANS AND CALCULATION FOR THE AIR VENTILATION OF THE CRAWLSPACE. SEE
SECTION 107 2017 FLORIDA BUILDING CODE.
Comment: • PLEASE FURNISH ENERGY CALULATIONS AND MANUAL J IN ACCORDANCE WITH SECTIONS 402 AND 403
11/15/2019 OF THE 2017 FLORIDA ENERGY CODE. NOTE ONLY; ENERGIES MUST HAVE ORIGINAL SIGNATURE OF
PREPARER
11/15/2019 Comment: PLEASE SHOW ON THE PLANS THE TRUST FASTENING SCHEDULE. SEE SECTION 107 OF THE 2017
FLORIDA BUILDING CODE
11/15/2019 Comment: PLEASE SHOW ON THE PLANS THE ROOF LAYOUT WITH ZONE REQUIREMENTS. SEE SECTION 107 2017
FLORIDA BUILDING CODE
11/15/2019 Comment: FRONT ENTRY TO NON-CONDJTIONED SPACE MUST BE FLOOD VENTED. SEE SECTION 322 OF THE 2017
FLORIDA RESIDENTIAL BUILDING CODE.
11/15/2019 Comment: PLEASE SHOW ON THE PLANS THE ATTACHMENT METHOD FOR THE 4 X 4 POST AT THE PROPOSED
ELEVATED DECK TO THE EXISTING FOUNDATION. SEE SECTION 107 2017 FLORIDA BUILDING CODE.
Comment: PLEASE SHOW ON THE PLANS THE CORRECT ELEVATIONS STARTING WITH THE EXISTING ELEVATION OF
11/15/2019 THE SLAB AND THE GRADE TO BASE FLOOD ELEVATION TO MEAN ROOF HEIGHT. SEE SECTION 107 2017
FLORIDA BUILDING CODE.
Comment: THE STRUCTURE WILL BE CONSIDERED AS A SUBSTANTIAL IMPROVEMENT TO THE EXISTING
CONDITIONS. THE STRUCTURE MUST COMPLY WITH ALL CODES AND REGULATIONS MEETING THE
REQUIREMENTS OF THE SUBSTANTIAL IMPROVEMENT FOR A STRUCTURE IN THE FLOOD ZONE. PLEASE
11/15/2019 SUBMIT DRAWINGS THAT CLEARLY SPECIFY AND SHOW THE STRUCTURE MEETING THE REQUIREMENTS
OF THE 2017 FLORIDA EXISTING BUILDING CODE, 2017 FLORIDA RESIDENTIAL BUILDING CODE, FEMA
REQUIREMENTS, AND THE LAND DEVELOPMENT CODE.
11/15/2019 Comment: IN ALL DOCUMENTS HAVE BEEN SUBMITTED FOR REVIEW ADDITIONAL COMMENTS MAY BE REQUIRED TO
CORRECT ANY DEVIATION FROM THE CODES.
ZONING REVIEW INCOMPLE t Lydia Galbraith 11/6/2019
11/7/2019 Comment: PROP SED STRUC RE IS NOT MEETING THE MIN. REQUIRED SETBACK OF VON THE LEFT SIDE (ST.
LUCI COUNTY LAND EV. CODE CHAPTER 7.10.16 Q)
\� Comment: THE PROPOSED REA DECK IS ENCROACHING IN THE MIN. REQUIRED 5' SETBACK.
PL SE INDICATE PR POSED DECK ON SURVEY MEETING CODE.
t \v STE S OR RAMPS FO ACCESS PURPOSES MAY BE ERECTED, BUT MAY NOT ENCROACH INTO ANY
`\1 REQ IRED SIDE SET ACK. STEPS OR RAMPS MAY ENCROACH INTO THE FRONT OR REAR SETBACKS, IF
NEC SSARY PROVI ED THAT THE STEPS OR RAMPS DO NOT OCCUPY MORE THAN TEN PERCENT (10%)
1/7/2019 OFT REQUIRE RONT OR REAR YARD UNLESS OTHERWISE APPROVED BY THE ST. LUCIE COUNTY
BOAR OF ADJ TMENT IN ACCORDANCE WITH SECTION 10.01.00.
STEPS MPS WHICH ENCROACH INTO FRONT OR REAR SETBACKS MAY NOT HAVE A LANDING WITH
DIMENSION EXCESS OF FOUR (4) FEET BY FOUR (4) FEET WHERE SUCH LANDING ENCROACHES INTO
THE REQUIRED ONT OR REAR SETBACK. THE ALLOWED ENCROACHMENT IN THE REAR SETBACK WILL
BE 15 SF.
11/7 019 Comment: THE FINISHED FLOOR EVATION IS REQUIRED TO BE FLOODZONE + 1'. MIN.REQUIRED FLOOD
ELEVATION IS 7'+ V= 8'
11/7/2019 Comment: PLEASE INDICATE ON TH SURVEY TWO PARKING SPACES OF EACH 8'X18'.
11/7/2019 Comment: THE SUBMITTED SURVEY 13 A COPY. PLEASE PROVIDE 2 SIGNED AND SEALED SURVEYS UPDATED WITH
ABOVE COMMENTS.