HomeMy WebLinkAboutEvaluation Report; Smart Vent Automatic Foundation Flood VentsDIVISION: 08 00 00—OPENINGS SECTION: 08 95 43—VENTS/FOUNDATION FLOOD VENTS REPORT HOLDER: SMARTVENT PRODUCTS, INC. 430 ANDBRO DRIVE, UNIT 1 PITMAN, NEW JERSEY 08071 EVALUATION SUBJECT: SMART VENT° AUTOMATIC FOUNDATION FLOOD VENTS: MODELS #1540-520; #1540-521; #1540-510; #1540-511; #1540-570; #1540-574; #1540-524; #1540-514 1CC 1CC I q 1CC c PM0 c LISTED Look for the trusted marks of Conformity! "2014 Recipient of Prestigious Western States Seismic Policy Council (WSSPC) Award in Excellence" A Subsidiary of ICGES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not id specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as isontc grass to any finding or other matter in this report, or as to any product covered by the report. ProCud ce : on g dy „u _,ono Copyright ° 2017 ICC Evaluation Service, LLC. All rights reserved. ESR-2074 I Most Widely Accepted and Trusted Page 2 of 5 installed with a minimum of one FV for every 5.2 The Smart Vent® FVs must not be used in the place 400 square feet (37.2 mZ) of enclosed area. of "breakaway walls" in coastal high hazard areas, but ■ Below the base flood elevation. are permitted for use in conjunction with breakaway walls in other areas. ■ With the bottom of the FV located a maximum of 12 inches (305.4 mm) above the higher of the final grade or floor and finished exterior grade immediately under each opening. 5.0 CONDITIONS OF USE The Smart Vent® FVs described in this report comply with, or are suitable alternatives to what is specified in, those codes listed'in Section 1.0 of this report, subject to the following conditions: 5.1 The Smart Vent® FVs must be installed in accordance with this report, the applicable code and the manufacturer's installation instructions. In the event of a conflict, the instructions in this report.govem. 6.0 EVIDENCE SUBMITTED Data in accordance with the ICC-ES Acceptance Criteria for Mechanically- Operated Flood Vents (AC364), dated August 2015. 7.0 IDENTIFICATION The Smart VENT® models recognized in this report must be identified by a label bearing the manufacturer's name (Smartvent Products, Inc.), the model number, and the evaluation report number (ESR-2074). TABLE 1—MODEL SIZES MODEL NAME MODEL NUMBER MODEL SIZE (in.) COVERAGE (sq. ft.) FloodVEN ; 1540 520 15 " X 7 /a" . 200 SmaftVENT® 1540-510 153/4" X 73/a' 200 FloodVENTO Overhead Door 1540-524 153/4" X 73/4" 200 SmartVENT® Overhead Door 1540-514 153/4" X 73/4" 200 Wood Wall FloodVENTO 1540-570 14" X 83/4o' 200 Wood Wall FloodVENTO Overhead Door 1540-574 14" X 83/4". 200 SmartVENT® Stacker 1540-511 16" X 16" 400 FloodVent® Stacker 1540-521 16" X 16" 400 For SI: 1 inch = 25.4 mm; 1 square foot = m`