HomeMy WebLinkAboutEvaluation Report; Smart Vent Automatic Foundation Flood VentsDIVISION: 08 00 00—OPENINGS
SECTION: 08 95 43—VENTS/FOUNDATION FLOOD VENTS
REPORT HOLDER:
SMARTVENT PRODUCTS, INC.
430 ANDBRO DRIVE, UNIT 1
PITMAN, NEW JERSEY 08071
EVALUATION SUBJECT:
SMART VENT° AUTOMATIC FOUNDATION FLOOD VENTS: MODELS #1540-520;
#1540-521; #1540-510; #1540-511; #1540-570; #1540-574; #1540-524; #1540-514
1CC 1CC I q 1CC
c PM0 c LISTED
Look for the trusted marks of Conformity!
"2014 Recipient of Prestigious Western States Seismic Policy Council
(WSSPC) Award in Excellence" A Subsidiary of
ICGES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not id
specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a
recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as
isontc grass
to any finding or other matter in this report, or as to any product covered by the report. ProCud ce : on g dy „u
_,ono
Copyright ° 2017 ICC Evaluation Service, LLC. All rights reserved.
ESR-2074 I Most Widely Accepted and Trusted Page 2 of 5
installed with a minimum of one FV for every 5.2 The Smart Vent® FVs must not be used in the place
400 square feet (37.2 mZ) of enclosed area. of "breakaway walls" in coastal high hazard areas, but
■ Below the base flood elevation. are permitted for use in conjunction with breakaway
walls in other areas.
■ With the bottom of the FV located a maximum of
12 inches (305.4 mm) above the higher of the final
grade or floor and finished exterior grade immediately
under each opening.
5.0 CONDITIONS OF USE
The Smart Vent® FVs described in this report comply with,
or are suitable alternatives to what is specified in, those
codes listed'in Section 1.0 of this report, subject to the
following conditions:
5.1 The Smart Vent® FVs must be installed in accordance
with this report, the applicable code and the
manufacturer's installation instructions. In the event of
a conflict, the instructions in this report.govem.
6.0 EVIDENCE SUBMITTED
Data in accordance with the ICC-ES Acceptance Criteria
for Mechanically- Operated Flood Vents (AC364), dated
August 2015.
7.0 IDENTIFICATION
The Smart VENT® models recognized in this report must
be identified by a label bearing the manufacturer's name
(Smartvent Products, Inc.), the model number, and the
evaluation report number (ESR-2074).
TABLE 1—MODEL SIZES
MODEL NAME
MODEL NUMBER
MODEL SIZE (in.)
COVERAGE (sq. ft.)
FloodVEN ;
1540 520
15 " X 7 /a" .
200
SmaftVENT®
1540-510
153/4" X 73/a'
200
FloodVENTO Overhead Door
1540-524
153/4" X 73/4"
200
SmartVENT® Overhead Door
1540-514
153/4" X 73/4"
200
Wood Wall FloodVENTO
1540-570
14" X 83/4o'
200
Wood Wall FloodVENTO Overhead Door
1540-574
14" X 83/4".
200
SmartVENT® Stacker
1540-511
16" X 16"
400
FloodVent® Stacker
1540-521
16" X 16"
400
For SI: 1 inch = 25.4 mm; 1 square foot = m`