HomeMy WebLinkAboutAPPROVED 2870 Gregory Ln - Underlayment Product Approval11412UZI
Florida Building Code Online
Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map
Links Search
D01
Product Approval
M: Public User
Product Approval Menu > Product Or Ai?pliCgkion, Search > ggplication Li;;t > Application Detail
FL V
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
FL2569-R20
Revision
2020
Approved
Soprema, Inc. (Canada)
1640 rue Haggarty
Drummondville, NON -US 00000
(819)478-2400
memathieu@sap re ma , ca
Marc -Etienne Mathieu
memathieu@soprema.ca
Marc -Etienne Mathieu
1688 Jean-Berchmans- Michaud
Drummondville, NON -US 00000
(819)478-2400 Ext3327
memathieu@soprema.ca
Jean -Francois Cote, Ph.D.
1640 rue Haggarty
Drummondville
(888)811-3145
jfcote@soprema.ca
Roofing
Underlayments
e"
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect !Name who developed the Robert 3. M. Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 04/10/2023
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FL2569 R2.0 C.01. 20_2D_ 01 COI NIEMINEN.pjf
Referenced Standard and Year (of Standard) Standard Year
ASTM D1970 2015
ASTM D4798 2011
ASTM D6163 2015
FM 4474 2011
FRSA/TRI Sixth Edition 2018
UL 1897 2012
https:llflohdabullding.orglprlpr_app_dtl.aspx?param=wGEVXQwtDgsKQFEnckB10BErxl Ud3xYlmjtrnBrpDan9H30QGunUKXA%3d%3d 112
1141'20L i
Florida Building Code Online
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date
Submitted
09/19/2020
Date
Validated
09/22/2020
Date
Pending FBC Approval
09/29/2020
Date
Approved
12/15/2020
Date
Revised
12/16/2020
Summary of Products
7-
FL #
Y
Model, Number or Name
Description
12569.1
Soprema Roof Underlayments
Self adhering roof underlayments
Limits of Ilse
Installation Instructions
Approved for use in HVHZ: No
FL25§9 R20 11 2020 09 17 FINAL ER FL2 -R O.pdf
Approved for use outside HVH2: Yes
Verified By: Robert N)eminen, P.E. PE-59166
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-150
Evaluation Reports
Other: 1.) Refer to ER Section 5 for Limits of Use. 2,) The
FL2569 R20 AE 2020 09 17 FINAL ER F 2569-R2 .pd
design pressure noted herein pertains to underlayment systems
Created by Independent Third Party: Yes
used beneath adhesive -set tile systems. Refer to ER Section
5.6.4 for details.
Contact Us :: 2601 Blair Stone Road Tallahassee FL 32399 Phone: 650-487-1824
The Stale of Florida Is an AA/EEC employer, Cop ri ht 20 7-2013 Stale of F on r: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are pubiic records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850,487,1395. 'Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
Credit Card
Safe
https://fioridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsKQFEnckBIOBErxlUd3xYlmjtrnBrpDan9H30OGunUKXAa/e3da/e3d 212
n
LJ
NEMO I etc.
Certificate of Authorization #32455
353 Christian Street, Unit 413
Oxford, CT 06478
(203) 262-9245
ENGINEER EVALUATE TEST CONSULT
Soprema, Inc. Evaluation Report S18010.06.09-R18
1640 rue Haggerty FL2569-R20
Drummondville, Quebec J2C 5P8 Canada Date of Issuance: 06/15/2009
(819) 478-2400 Revision 18: 09/17/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 71h Edition (2020) Florida Building Code sections noted herein.
DESCRIPTION: Soprema Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time asthe named product(s) changes, the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). MEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO Ietc. Evaluated" may be
displayed in advertising literature, If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer
or its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59155, Florida DCAANE198.3
CERTIFICATION OF INDEPENDENCE'
The facsimile seal appearing was authorized by Robert
�% FS>`;;'••• ' c' -
Nieminen, P.E. on 09/17/2020. This does not serve as
'!^•�,.+'•"•
an electronically signed document.
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO FTC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
O2o19 NEMO ETC, LLC
ON EMo I etc.
ROOFING COMPONENT EVALUATION:
Product Category:
Roofing
Sub -Category.
Underlayment
Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the
following sections of the 7`h Edition (2020) Florida Building Code through testing in accordance with the following
Standards. Compliance is subject
to the Installation Requirements
and Limitations Conditions of Use set forth
herein.
Section
Property
Standard
Year
1504.3.1
Wind resistance
FM 4474
2011
1504.3.1
Wind resistance
UL 1897
2012
1507.1.1, 1507.2.4, 1507.2.9.2
Material standard
ASTM D1970
2015
/ R905.1.1, R905.2.8.2
1507.3.3 / R905.3.3
Material standard
FRSA/TRI, Sixth Edition
2018
1507.11.2 / R905.11.2
Material standard
ASTM D6163
2015
TAS 110
Accelerated Weathering
ASTM D4798
2011
En_ tits
Examination
Reference
Date
LRD (T5T6049)
Wind Resistance
2778.07.05
07/15/2005
ERD (TST6049)
ASTM 01970 / TAS 110 (QC)
S31370.03.10-1-R1
04/07/2010
ERD (TST6049)
FRSA/TRI 04-12 (OH)
511150.05.09-R2
10/05/2010
ERD (TST6049)
ASTM D1970 (OH)
537210.11.11
11/09/2011
ERD (TST6049)
ASTM D1970 (M5)
537210.12.11
12/01/2011
ERD (TST6049)
ASTM D1970 (MS)
S40540.02.13-1
02/19/2013
ERD (TST6049)
FRSA/TR104-12(MS)
S43530.02.14-1-R1
02/21/2014
ERD (TST6049)
ASTM D1970 (BC)
S44870.04.14-2
04/02/2014
ERD(TST6049)
ASTM D1970(QC)
S44870.04.14-3
04/02/2014
ERD (TST6049)
ASTM D1970 (OH)
S44870.04.14-1
04/10/2014
ERD (TST6049)
ASTM D1970 (MS)
544870,04,14-4
04/10/2014
ERD (TST6049)
ASTM D1970 (OH)
540540.10.14
10/31/2014
ERD (TST6049)
Tensile Adhesion / Long Term Aging
SOPC-5C7645.02.15
02/13/2015
ERD (TST6049)
Accelerated Weathering
SOPC-SC8520.04.14
04/27/2015
ERD (TST6049)
Wind Resistance
SOPC-SC14045.05.17-RI
06/07/2017
M-D (CER1592)
HVHZ Compliance
18-0329.03
06/28/2019
ICC-ES (EVL2396)
201S IBC Compliance
ESR-1524
03/01/2017
NFMO (TST6049)
ASTM D1970 / TAS 110 (QC)
SOPC-SC8970.08.15-Ri
04/25/2018
NEMO (TST6049)
Wind Resistance
4-50PC-18-003.08.18
08/27/2018
NEMO (TST6049)
ASTM D4798/D1970 (OH & MS)
4S-SOPC-18-002.05.19.A
05/31/2019
NEMO (TST6049)
Tensile Adhesion / Long Term Aging
4p-DOW-I9-SSLAP-01.A.R2
02/10/2020
NEMO (TST6049)
Peel adhesion (existing underlayments)
4j-SOPC-I9-SSUDL-04.A
03/12/2020
PRI (TST5878)
ASTM D1970 (MS)
SOP-064-02-01
17/03/2013
Soprema, Inc. (PDM3511)
Equivalency Declaration
SA SMOOTH PLY 40
06/29/2015
UL, LLC (QUA9625)
Quality Control
MLA File No. R2760S
OS/08/2019
UL, LLC (QUA9625)
Quality Control
Service Confirmation
06/29/2020
MEMO ETC, LLC Evaluation Report 518010.06.09-R18
Certificuleof Authorization #32455 7T11 EDITION (2020) EBL NON-HVHZ EVALUATION FL2569-R20
Soprema Roof Underlayments Revision 18: 09/17/2020
Page 2 of 8
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
4.9
4.10
4.11
4.12
4.13
4.14
4.15
4.16
t4NEMO ! etc.
,.rrUCT DESCRIPTION:
Product
Material
Standard
Plant(s) Description
Lastobond TV HT
ASTM D1970 and
Gulfport, MS self -adhering, non -woven polyester fabric
FRSA/TRl 09-18
surfaced, SBS modified bitumen roof
underlayment
Lastobond Shield
ASTM D1970
_
Drummondville, QC self -adhering, woven polyethylene surfaced, SBS
modified bitumen roof underlayment available in
two widths; 36 and 45 inch
RESISTO SA SMOOTH PLY
ASTM D1970
Drummondville, QC self -adhering, woven polyethylene surfaced, SBS
40
modified bitumen roof underlayment
Lastobond Shield HT
ASTM D1970
Drummondville, QC self -adhering, woven polyethylene surfaced, high
temperature, SB5 modified bitumen roof
underlayment
Lastobond Pro HT-N
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, SBS
modified bitumen roof underlayment available in
two widths; 36 and 45 inch
Lastobond Pro HT-S
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, 5B5 modified bitumen roof
underlayment
EnviroShield
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof
underlayment
Lastobond 195
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, sand -
Wadsworth, OH
surfaced, SBS modified bitumen roof
underlayment
Lastobond Eaves
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, sand -
Protection Sheet
Wadsworth, OH
surfaced, SB5 modified bitumen roof
underlayment
Lastobond Eco
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
Gulfport, M5
surfaced, 5135 modified bitumen roof
Wadsworth, OH
underlayment
Lastobond Smooth Seal
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, film -
HT
Wadsworth, OH
surfaced, SBS modified bitumen roof
underlayment
PrimeSource Grip -Rite
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, film -
Smooth Seal HT
Wadsworth, OH
surfaced, SBS modified bitumen roof
underlayment
RES15TO LB1236
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
PrimeSource Grip -Rite
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand-
Eave & Valley Protector
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
5RS TopShield ICE &
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
WATER DEFENDER
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
RESISTO LB1244
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
NEMO ETC, LLC
Certificate ofAuthorizution N32455
7'H EDITION 120201 F13C NON-HVHZ EVALUATION
Soprema Roof Underlayments
Evaluation Report 518010A6.09-R18
FL2569-R20
Revision 18: 09/17/2020
Page 3 of 8
4.17
0NK1Pn'4n1"n'+'-
Product
Material
Standard
Plant(s)
Description
Colphene FR GR
ASTM D6163
Gulfport, MS
self -adhering, fiberglass reinforced, granule -
Wadsworth, Oft
surfaced, SBS modified bitumen roof
underlayment
S.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in F3C High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -
Dade Counties).
5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.5 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
Clay and Concrete Tile
Slate or
Asphalt
(1507.3)
Metal
State-TypeWood
Underlayment
Shingles
Mechanical
Adhesive-
Panels
Shingles
Shingles
(15072)
Shingles
Attach
Set
j1507.4)
(1507,5)
(1507.7)
(1507.8)
Shakes (1507.,9)
Lastobond TU HT
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
See S.b.1
[joint strips, 1507.1.1.3
(joint strips, 1507.1.1.3
/ R905.1.331
f R905.1.1.3)
Lastobond Shield / Pro HT-N
Yes
Yes
/ RESISTO SA SMOOTH PLY
Yes
No
No
No
No
Yes
{joint strips, 2507.1.1.3
(join[ strips, 1507.1.1.3
40
/R905.1.1.3#
/R905.i,1.3)
Lastobond Shield HT/ Pro
Yes
Yes
HT-S
Yes
No
No
Yes
Yes
Yes
Ijoint strips, 1s07.1.1.3
{joint strips, 1507.1.1.3
R905.1.1.3)
Yes
Yes
fnviroShiefd
Yes
No
No
Yes
Yes
Yes
Ijoint strips, I507.1.1.3
{join) strips, 1507.1.1.3
J R905.1.1.3)
/ R905.1.1.3#
Lastobond Eaves Protection
Yes
Yes
Sheet / Lastobond 195
Yes
No
No
No
No
Yes
{joint strips, 1507.1.1.3
{jointstrips, 1507.1.1.3
/ R905.1.1.3}
/ R9U5.1.1.31
Lastobond ECO / RESISTO
1.131236, Grip -Rite Eave &
Yes
Yes
Vafley Protector /TopShield
Yes
No
No
No
No
Ycs
(joint strips, 7507.1.1.3
(joint strips, 7507.1.1.3
ICE & WATER DEFENDER/
f R905.1.1.31
/R905.1.1.3)
RESISTO W1244
Lastobond Smooth Seal HT J
Yes
Yes
Grip -Rite Smooth Seal HT
Yes
No
No
Yes
Yes
Yes
)joint strips, 1507.1.1.3
(join[ strips, 1507.1.1.3
/ R9os.1.1.3)
/ R9ns_1.1.3]
Yes
Yes
Colphene FR GR
Yes
Yes
No
No
No
Yes
[joint strips, 1507.1.1.3
(joint strips, 1507. i1.3
/ R905.1.1.31 1
/ R9os.1.1.3)
NEMO ETC, LLC Evaluation Report S18010.06.09-1118
Cerrificote ofAuthorizotion #32455 75n EDITION 12020i FBC NON-HVHZ EVALUATION FL2569-R20
Soprema Roof Underlayments Revision 18; 09/17/2020
Page 4 of 8
MEMO 1 etc.
5.6.1 Adhesive -set tile is limited to use of the following Approved underlayment / tile -adhesive combinations.
TABLE ZA: ALLOWABLE TILE ADHESIVE / UNDERLAYMENT COMBINATIONS'
Underlayment Adhesive Florida Product Approval
Dupont "Tile Bond"" Roof Tile Adhesive" FL22525
Lastobond TU HT
ICP Adhesives and Sealants "Polyset" AH-160" FL6332
S.7 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Underlayment
Application
Substrates (designed to meet wind loads for project)
Type
Primer
Material(s)
Lastobond Shield, Lastobond Pro
(Optional) ASTM
HT-N, RESISTO SA SMOOTH PLY
Deck /
D41, Elastocol Stick,
plywood, 056 or Southern Yellow Pine
40, Lastobond Shieid HT,
sheathing
Elastocol Stick Zero
(SYP)
Lastobond Pro HT-S,
ASTM D41
structural concrete
EnviroShield, Lastobond TU HT,
Insulation
(Optional) Elastocol
Dens Deck Prime or SECUROCK Gypsum -
Lastobond Eaves Protection
Sheet, Lastobond 195, Lastobond
Self
Stick Zero
Fiber Roof Board
ECO, RESISTO LB1236, Grip -Rite
adhering
Eave & Valley Protector,
TopShield ICE & WATER
Base Sheet
(Optional) Elastocol
A5TM D226, Type II felt or Modified Sopra-
DEFENDER, RFSISTO LB1244,
Stick Zero
G
Lastobond Smooth Seal HT or
Grip -Rite Smooth Seal HT
(Optional) ASTM
Deck /
D41
pl wood
Y
sheathing
ASTM D41
structural concrete
Colphene FR GR
self
adhering
Insulation
(Optional) Elastocol
Dens Deck Prime or SECUROCK Gypsum -
Stick Zero
Fiber Roof Board
Base Sheet
(Optional) Elastocol
ASTM D226, Type II felt or Modified Sopra-
Stick Zero
G
RESISTO LB1236, Grip -Rite Eave
self
Existing
EXTERIOR
Existing sand -surfaced, glass -fiber surfaced,
& Valley Protector or TopShield
adhering
substrate
PRIMER
PRIMER
mineral -surfaced or film -surfaced roof
ICE & WATER DEFENDER
underlayment*
* Final acceptance of any existing substrate in a reroof (tear -off) installation is at the discretion of the installer and the Authority
Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive RESISTO LB1236, Grip -Rite Eave &
Valley Protector or TopShield lCF & WATER DEFENDER self -adhering uoderloyments, contact RESISTO technical support.
5.7.1 Soprema recommends priming with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof
cover is not slated for installation within 24 hours.
5.7.2 Soprema requires tongue -and -groove board decking be covered with plywood or OSB prior to installation of the
self -adhering underlayment
Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performunce
NEMO ETC, LLC Evaluation Report S18010.06.09-R18
Certificate of Authorizarion #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-RZO
Soprema Roof Underlayments Revision IS: 09/17/2020
Page 5 of 8
5.8 Attachment Limitations: NNEMOletc.
5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with
the manufacturer's installation instructions, but -for mechanically attached underlayments or base sheets - not
less than FBC 1507.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation
instructions, but - for mechanically attached base sheets - not less than:
• FRSA/TRI Florida Nigh Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A,
Table 1(for Two -Ply Asphalt Applied Hot Mop Underlayment)
or
Section 5.8.3 herein (for other underlayment systems).
5.8.3 Wind Resistance for Underla ment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI
Florida Nigh Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. The Maximum Design Pressure
is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing
pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
S.83.1 Direct -to -Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida Nigh Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the
critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
#1 Maximum Desi n Pressure = -45.0 sf:
Deck: Min. 1S/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional) Elastocol Stick, Elastocol Stick Zero or RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT, self -adhered.
#2 Maximum Design Pressure =-67.5 osf:
Deck:
Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer:
Elastocol Stick Zero
Underlayment:
Lastobond TU HT, self -adhered.
43 Maximum Desi
n Pressure - -120.0 sf:
Deck:
Min. 15/32-inch APA-rated CDX plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer:
(Optional) RESISTO EXTERIOR PRIMER
Base Ply:
RESISTO SA SMOOTH PLY 40, self -adhered.
Underlayment:
Lastobond TU HT, self -adhered.
44 Maximum Design Pressure = -150.0 psf:
Deck:
Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project requirements to
satisfaction of Authority Having Jurisdiction.
Primer:
(Optional) RESISTO EXTERIOR PRIMER
Underlayment:
Lastobond TU HT, self -adhered.
45 All other direct -deck, adhered underlayment systems beneath the roof systems carry a Maximum Design
Pressure of -45
psf.
NEIVIO ETC, LLC
Certificote of Authnrizotian #324SS
7"' EDITION (2020) FBC NON-HVHZ EVALUATION
Soprema Roof Underlayments
Evaluation Report S18010.06.09-1118
FL2569-R20
Revision IS: 09/17/2020
Page 6 of 8
5.8.3.2 Mechanically -Attached Base Sheet:
ON EMO I etc.
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida Nigh Wind Concrete and Clay hoof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the
critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
Alternatively, the maximum designs pressure for the selected assembly shall meet or exceed at least the Zone 1
design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones
shall employ an attachment density designed by a qualified design professional to resist the elevated pressure
criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Applications
Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the
limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for
enhancements.
46 Maximum Design Pressure = -60.0 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet; Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC 1517.5.2) spaced 6-
inch o.c. at the 4-inch laps and 6-inch o.c. in three (3), equally spaced rows in the center of the sheet.
Underlayment: Lastobond TU HT, self -adhered
5.8.4 For use over insulation or coverboard and under mechanically attached prepared roof coverings, underlayment
attachment shall be in accordance with the manufacturer's installation instructions and attachment of the
insulation or coverboard shall be in accordance with the prepared roof covering manufacturer's Product
Approval.
5.9 Exposure Limitations;
TABLE 3: ExPOSuftE LIMITATIONS
Underlayment
Prepared Roof Cover
Maximum
Installation Type
Exposure (days)
Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco, RESISTO 1-131236, Grip-
Mechanically
Rite Eave & Valley Protector, TopShield fCE & WATER DEFENDER or RESISTO LB1244
attached
30
Lastobond TU HT
Adhesive -set the roof
30
system
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT,
Mechanically
Lastobond Pro HT-5, Fnviro5hield, Lastobond Smooth Seal HT or Grip -Rite Smooth Seal HT
attached
90
Lastobond TU HT or Colphene FR GR
Mechanically
180
attached
5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the
maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during
loading of the roof tiles.
TARLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS
Underlayment
Tile Profile
Staging Method
Maximum Slope
Flat
Max. 10-tile stack
6:12
Lugged
Max. 10-tile static
5:12
Max. 10-tile stack (bottom 2-tile stack shall be inverted,
followed by 8 tiles high on slope, as shown below)
6:12
Lastobond TU H7
Lugged
d
NEMO ETC, LLC
Cerirficate of Authorization #32955
7n" EDITION 12020) FIX NON-HVHZ EVALUATION
SDprema Roof Underlayments
Evaluation Report S18010-06.09-1118
FL2569-R20
Revision 18: 09/17/2020
Page 7 of 8
ONEMOJetc.
TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS
Underlayment Tile Profile Staging Method Maximum Slope
Colphene FR GR Flat Max. to -tile stack 5;1Z
Lugged Max. 10-tile stack 6:12
NSTALILATIICIN*,'�
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation instructions
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application, and prime the substrate (if applicable).
6.2.1 Installation of RESISTO L131236, Grip -Rite Eave & Valley Protector or TopShield ICE & WATER DEFENDER self -
adhering underlayment in a reroof (tear -off) application atop an existing underlayment (per Table 2) requires
priming of the existing substrate with RESISTO EXTERIOR PRIMER. Final acceptance of any existing substrate in a
reroof (tear -off) installation is at the discretion of the installer and the Authority Having Jurisdiction. Should a
question arise as to the suitability of an existing substrate to receive RESISTO LB1236, Grip -Rite Eave & Valley
Protector or TopShield ICE & WATER DEFENDER self -adhering underlayments, contact RESISTO technical support.
6.3 Lastobond TU HT, Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT,
Lastobond Pro HT-S, EnviroShield, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond Eco, Lastobond
Smooth Seal HT, Grip -Rite Smooth Seal HT, RESISTO LB1236, Grip -Rite Eave & Valley Protector, TopShield ICE &
WATER DEFENDER, RESISTO LB1244 or Colphene FR GR:
b.3,1 Non- IfleApplications:
Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R90S.1.1.3 for the type of prepared roof covering
to be installed, and the manufacturer's installation instructions.
When installed over a mechanically attached base sheet of FBC Approved ASTM D226, Type II felt the base sheet
shall be fastened in accordance with FBC 1507.1.1 or R905.1.1.
6.3.2 Tile Applications;
Limited to Lastobond TU HT or Colphene FR GR.
Shall be installed in compliance with the requirements for Self -Adhered Membrane set forth in FRSA/TRI Florida
High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition and the manufacturer's installation
instructions.
Refer to Section 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for tile staging limitations.
Refer to7.8.2 for attachment limitations.
Refer to Table 4 for the staging limitations.
• •
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
ANUFACTUiIING PLAN
Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61GZO-3 CIA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
UL, LLC—QUA9625; (314) 578-3406; k.chancellor@u5ml.com
- END OF EVALUATION REPORT -
NEMO ETC, LLC Evaluation Report S18010.06.09-R18
CeNifitote of Authorization N32455 7;" EDITION (20201 FBC NON-HVH2 EVALUATION FL2569-R20
Soprema Roof Underlayments Revision 18: 09/17/2020
Page 8 of 8