i + WIrightsoft Project Summary Entire House For: Dunshee Residence RECEIVE 7407 Bayard Rd, Fort Pierce, FL 34951 MAR' 2.9 2021 Notes: Permitting I,partment St. Lucid County I DesignInf6rmation r Weather: Vero Beach Muni, FL, US Winter Design Conditions Outside db 43 °F Inside db 70 'F Design TD 27 °F Heating Summary Structure 18059 Btuh Ducts 7055 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 25114 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 Heating Cooling Area (ft2) 1903 1903 Volume (ft3) 15224 15224 Air changes/hour 0.38 0.20 Equiv. AVF (cfm) 96 51 Heating Equipment Summary Make Champion Trade Champion Model 8kw AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 8.0 kW 27297 Btuh 18 °F 1350 cfm 0.054 cfm/Btuh 0.53 in H2O Job: Dunshee Residence - C... Date: Mar 10, 2021 By: James Bolton Summer Design Conditions Outside db 91 °F Inside db 75 °F Design TD 16 °F Daily range L Relative humidity 50 % Moisture difference 59 gr/lb Sensible Cllooling Equipment Load Sizing Structure 20511 Btuh Ducts 10890 Btuh Central vent,(0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier Equipment load 0.95 29988 Btuh sensible Latent Cooling Equipment Load Sizing Structure 2846 Btuh Ducts 2879 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 5726 Btuh i Equipment Total Load (Sen+Lat) 35714 Btuh Req. total capacity at 0.80 SHR 3.1 ton Cooling Equipment Summary Make ChamHAMpion Trade CPION HEATING AND COOLING Cond TC4134222 Coil AP42CX21++TXV AHRI ref 205758460 Efficiency 11.5 EER, 14 SEER Sensible cooling 32400 Btuh Latent cooling �, 8100 Btuh Total cooling 40500 Btuh Actual air flow 1350 cfm Air flow factor 0.043 cfm/Btuh Static pressure 0.53 in H2O Load sensible heat ratio 0.85 Calculations approved by ACCA to meet all requirements of,Manual J 8th Ed. -FI}- wirgl•isotT#" 2021-Mar-2410:52:01 k .« Right -Suite® Universal 2021 21.0.05 RSU11033 Page 1 •ACCN ...\Rev 1 -Dunshee Residence- C-1026 - J-4350.rup Calc = MJ8 Front Door faces: S I . wrightsoft, Duct System Summary Entire House ,i For: Dunshee Residence 7407 Bayard Rd, Fort Pierce, FL 34951 Job: Dunshee Residence - C... Date: Mar 10, 2021 By: James Bolton i Heating Cooling External static pressure 0.53 in H2O 0.53 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.53 in H2O 0.53 in H2O Supply / return available pressure 0.354 / 0.176 in H2O 10.354 / 0.176 in H2O Lowest friction rate 0.263 in/100ft 0.263 in/100ft Actual air flow 1350 cfm 1350 cfm Total effective length (TEL) 202 ft;' SupplyBranch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk Addition 2 h 2793 150 81 0.267 7.0 Ox 0 1VIFx 17.7 115.0 st1 Addition 2-A h 2793 150 81 0.263 7.0 Ox 0 ' VIFx 19.6 115.0 SO Existing House c 27652 1050 1189 0 0 Ox 0 'VIFx 0 0 Name Trunk Type Htg (cfm) Clg (cfm) Design FR • Veloc (fpm) Diam (in) H x W ! (in) Duct Material Trunk st1 Peak AVF 300 161 0.263 551 10.0 0 x 0 VinlFlx Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in), Opening (in) Matl Trunk rb2 Ox 0 300 161 67.0 0.263 382 12.0 Ox . 0 VIFx rb1 Ox0 1050 1189 0 0 0 0 Ox 0 VIFx - - wriglhtsaf Right -Suite® Universal 2021 21.0.05 RSU11033 f ...\Rev 1-Dunshee Residence - C-1026 - J-4350.rup Calc = MJ8 Front Door faces: S 2021-Mar-24 10:52:01 Page 1 13 i u Manual S Compliance Report Job: DunsheeResidence -C... wrianua ghtsoft� p p Date: Mar 10, 2021 Entire House By: James Bolton .,Project, Information, For: Dunshee Residence 7407 Bayard Rd, Fort Pierce, FL 34951 • • • quiipmenU Design Conditions Outdoor design DB: 90.5°F Sensible gain: 31401 Btuh Entering coil DB: 77.8°F Outdoor design WB: 77.8°F Latent gain: 5726 Btuh Entering coil WB: 64.0°F Indoor design DB: 75.0°F Total gain: 37127 Btuh Indoor RH: 50% Estimated airflow: 1350 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split AC Manufacturer: Champion Model: TC4B4222+AP42CX21++TXV Actual airflow: 1350 cfm Sensible capacity: 32400 Btuh 103% of load Latent capacity: 8100 Btuh 141% of load Total capacity: 40500 Btuh 109% of load SHR: 80% • • • Design Conditions Outdoor design DB: 43.0°F Heat loss: 25114 Btuh Entering coil DB: 69.1°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Elec strip Manufacturer: Champion Model: 8kw Actual airflow: 1350 cfm Output capacity: 8.0 kW 109% of load Temp. rise: 0 °F Meets all requirements of ACCA Manual S. V1CM" i[gIfiik's+GW 2021-Mar-24 10:52:01 wy# Right -Suite® Universal 2021 21.0.05 RSU11033 Page 1 ACr� ...\Rev 1-Dunshee Residence - C-1026 - J-4350.rup Calc = MJS Front Door faces: S N Job M Dunshee Residence - C-1026 - J-4351 Scale: 1 : 90 Performed by James Bolton for: Dunshee Residence Page 1 7407 Bayard Rd Right -Suite® Universal 2021 Fort Pierce, FL 34951 21.0.05 RSU11033 2021-Mar-24 10:52:18 ... Residence - C-1026 - J-4350.rul