Loading...
HomeMy WebLinkAboutAPPROVED Design Pressure Letter (1) Advanced Architecture & Planning LLC Architect & Planning 4929 S. Indian River Drive Ft. Pierce, FL 34982 (772)631-5709 Applied Wind Pressures Certification: December 04 2020 Bill Laprade Glass Professionals, Stuart, Florida Cell: 772-745-3459 Project: Gosk Residence 9960 S. Ocean Dr. Suite 1905 Jensen Beach, FL 34957 Dear Mr. Laprade: For the above address, the (6) replaced PGT Industries sliding glass doors, Series SGD-670, the minimum required wind pressures below are based on ASCE 7-16 and FBC 2017 wind load calculations. The applied wind pressures are as follows for the proposed replacement glazed units for Exposure D, per below and NOA: 20-0429.07: Series: Door or Window: Height Wind Zone: Applied Wind Pressure: (3) SGD-670 109”x96” 190 ft 5 +74.5 / -92.6.0 psf (3) SGD-670 144”x96” 190 ft 5 +62.9 / -89.6 psf In reviewing respective NOA for the above windows, the calculated respective design pressures are less than the respective minimum allowable NOA wind pressures as shown on Tables 2 or 3 for 36” wide by 96” high panels, and as such are acceptable to this office. If you have any questions, please contact me at any time. Thank you, Raymond Chladny, B.arch.Sc., M.arch, AIA, NCARB, Lic.#: AR-0017475