Loading...
HomeMy WebLinkAboutAPPROVED SGD670_20-0429.07 NOA No. 20-0429.07 Expiration Date: April 07, 2025 Approval Date: OCT 08, 2020 Page 1 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy PGT Industries, Inc. 1070 Technology Drive, North Venice, Fl. 34275 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series “SGD-670” Aluminum Sliding Glass Doors w/ 900 & 1350 corners -NI APPROVAL DOCUMENT: Drawing No. PGT0128 Rev D, titled “Series 670 Alum SGD-Non-Impact”, sheets 1 through 22 of 22, prepared by manufacturer, dated 02-02-14 and last revised on 04/22/20, signed and sealed by Lynn Miller, P.E., bearing the Miami-Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING: None: Approved Hurricane Protection devices, complying w/ FBC, as applicable are required. Limitations: 1. Max eight (8) panels configuration unit is allowed, having max nominal panel size not to exceed tested height & width per tables 1 thru 3. See sheets 6, 7 and 8 for Design Pressures (DP), glass types, Sill type for Positive DP limits, applicable Standard or Heavy-Duty parts and anchorage requirements. See Typ. Installation in sheet 10 for straight configured units, sheet 11 for corner units and sheet 14 for pocketed units. Pockets & Egress requirements to be reviewed by Building official. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and series and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA # 19-1126.01 and consists of this page 1 and evidence pages E-1, E-2, E-3 & E-4, as well as approval document mentioned above. The submitted documentation was reviewed by Ishaq I. Chanda, P.E. Ishaq I. Chanda, P.E. Product Control Unit Supervisor NOA No. 20-0429.07 Expiration Date: April 07, 2025 Approval Date: October 08, 2020 E - 1 PGT Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1.Evidence submitted under previous approvals A. DRAWINGS 1. Manufacturer's die drawings and sections (submitted under files See below) 2.Drawing No. PGT0128 Rev B, titled “Series 670 Alum SGD-Non-Impact”, sheets 1 thru 22 of 22, prepared by manufacturer, dated 02-02-14 and last revised on 06/08/16, signed and sealed by Lynn Miller, P.E. B. TESTS 1.REF Test report on 1) Uniform Static Air Pressure Test, per FBC, TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 Along with marked-up drawings and installation diagram of Aluminum Sliding Glass Doors (w/ TPS, Super, Cardinal & Duraseal Spacers), prepared by Fenestration Testing Laboratory, Inc., Test Reports No(s) FTL-8717, FTL-8970 and FTL-8968, dated 02/15/16, 06/07/16 and 06/20/16, all signed & sealed by Idalmis Ortega, P.E. 2.Test report on 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94. 4) Forced Entry Test, per FBC 2411.3.2.1 (b) and TAS 202-94 Along with marked-up drawings and installation diagram of Aluminum Sliding Glass Doors, prepared by Fenestration Testing Laboratory, Inc., Test Reports No(s) FTL-5979, FTL-5980, FTL- 5994, FTL-6002, FTL-6034 & FTL-6035, dated 08/10/09, all signed & sealed by Julio Gonzales, P.E. (All above test reports submitted under files # 14-0123.11, #11-1018.17/#09-0826.13) 2.Reference Test reports on 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94. 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411.3.2.1 (b) and TAS 202-94 Along w/ marked-up drawings and installation diagram of Aluminum Sliding Glass Doors, prepared by Fenestration Testing Laboratory, Inc., Test Reports NoFTL-7554, dated 11/01/13, signed & sealed by Marlin D. Brinson, P.E (This file has addendum letter dated 08/14/14 & marked-up drawings dated 08/19/14 & revised interior astragal marked-up Dwgs dated 11-11-13, all issued by Fenestration Testing 3. Additional REF supporting test # FTL 5254, FTL 5980, FTL 5987 and ATI72138.01-401-18. 4. Additional, Reference Fixed window test report FTL-7897 (cardinal spacer) per TAS 201, 202 & 203-94, issued by Fenestration Testing lab (Test report submitted under file #15-0430.08). C. CALCULATIONS (submitted under file #14-0123.11) 1. Anchor verification and comparative analysis dated 03/18/14, 06/25/14 and last revised on 01/30/15, sheets 1 thru 67, prepared by PGT, signed and sealed by Lynn Miller, P. E. 2.Glazing complies with ASTME-1300-02, -04 & -09. D. QALITY ASSURANCE 1.Miami Dade Department of Regulatory and Economic Resources (RER) Ishaq I. Chanda, P.E. Product Control Unit Supervisor NOA No. 20-0429.07 Expiration Date: April 07, 2025 Approval Date: October 08, 2020 E - 2 PGT Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED E.MATERIAL CERTIFICATIONS 1 None. F.STATEMENTS (submitted under file #14-0123.11) 1.Statement letter dated 10/08/15 of compliance to FBC 2014 (5th Edition) and “No financial interest”, prepared by PGT, signed & sealed by Lynn Miller, P.E. 2. Letter of lab compliance, part of the above test reports. G. OTHER 1.This NOA revises # 15-1013.14, expiring April 07, 2020. 2.Test proposal # 16-0125 dated 03/09/16 approved by RER. 3.AAMA’s Technical Paper for SGD & Bi-fold doors referenced to FBC 2014 (5th edition). 4. Test proposal dated 6/4/13 & 08/12/13 approved by Jaime Gascon, P.E. 5. Test proposals No(s) 09-0177, 0177-A, B & C approved by BCCO. 2. Evidence submitted under previous submittal A. DRAWINGS 1. Drawing No. PGT0128 Rev C, titled “Series 670 Alum SGD-Non-Impact”, sheets 1 through 22 of 22, prepared by manufacturer, dated 02-02-14 and last revised on 04/18/17, signed and sealed by Lynn Miller, P.E. B. TESTS 1. None. C. CALCULATIONS 1. Anchor verification calculations and structural analysis dated 04/18/17 and last revised on 08/09/17, complying with FBC-217 (6th Edition), prepared by PGT, signed and sealed by Lynn Miller, P.E. 2.Glazing complies with ASTME-1300-02, -04 &-09. D. QUALITY ASSURANCE 1.Miami Dade Department of Regulatory and Economic Resources (RER). ‘ E.MATERIAL CERTIFICATIONS 1. None. F.STATEMENTS 1. Statement letter of conformance to FBC 2014(5 th edition) & FBC 2017(6th Edition) and letter of no financial interest, prepared by PGT, dated 04/18/17, signed and sealed by Lynn Miller, P.E. G. OTHER 1.This NOA revises NOA # 16-0629.03, expiring April 07, 2020. 3. Evidence submitted under previous approval. A. DRAWINGS 1.Drawing No. PGT0128 Rev C, titled “Series 670 Alum SGD-Non-Impact”, sheets 1 through 22 of 22, prepared by manufacturer, dated 02-02-14 and last revised on 11/22/19, signed and sealed by Lynn Miller, P.E. B. TESTS 1. None. Ishaq I. Chanda, P.E. Product Control Unit Supervisor NOA No. 20-0429.07 Expiration Date: April 07, 2025 Approval Date: October 08, 2020 E - 3 PGT Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED C. CALCULATIONS (submitted under file #17-0420.09) 1. None 2.Glazing complies with ASTME-1300-02, -04 &-09. D. QUALITY ASSURANCE 1.Miami Dade Department of Regulatory and Economic Resources (RER). ‘ E.MATERIAL CERTIFICATIONS 1. None. F.STATEMENTS 1.Statement letter of conformance to FBC 2017 (6th Edition) and letter of no financial interest, prepared by PGT, dated 11/22/19, signed and sealed by Lynn Miller, P.E. G. OTHER 1.This NOA renews NOA # 17-0420.09, expiring April 07, 2025. 4.New Evidence submitted A. DRAWINGS 1.Drawing No. PGT0128 Rev D, titled “Series 670 Alum SGD-Non-Impact”, sheets 1 through 22 of 22, prepared by manufacturer, dated 02-02-14 and last revised on 04/22/20, signed and sealed by Lynn Miller, P.E. B.TESTS 1.Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4)Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked-up drawings and installation diagram of all PGT Industries, Inc. representative units listed below and tested to qualify Dowsil 791 and Dowsil 983 silicones, prepared by Fenestration Testing Laboratory, Inc., Test Reports No.: FTL-7897, PGT PW5520 PVC Fixed Window (unit 6 in proposal), dated 09/03/14 FTL-20-2107.1, PGT SGD780 Aluminum Sliding Glass Door (unit 7 in proposal) FTL-20-2107.2, PGT CA740 Alum. Outswing Casement Window (unit 8 in proposal) FTL-20-2107.3, PGT PW7620A Aluminum Fixed Window (unit 9 in proposal) and FTL-20-2107.4, PGT PW7620A Aluminum Fixed Window (unit 10 in proposal) dated 07/13/20, all signed and sealed by Idalmis Ortega, P.E. B.CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 7th Edition (2020), dated 04/22/20, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 2. Glazing complies with ASTM E1300-04, -09, -12 and -16. D. QUALITY ASSURANCE 1.Miami Dade Department of Regulatory and Economic Resources (RER). E.MATERIAL CERTIFICATIONS 1. None. Ishaq I. Chanda, P.E. Product Control Unit Supervisor NOA No. 20-0429.07 Expiration Date: April 07, 2025 Approval Date: October 08, 2020 E - 4 PGT Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED F.STATEMENTS 1.Statement letters of conformance to FBC 2020(7th Edition), dated 04/18/20, prepared, signed & sealed by Lynn Miller, P. E. G. OTHER 1.This NOA revises NOA #19-1126.01, and updates to FBC2020 (7th Edition), expiring 04/07/25. 2.RER Test proposals #19-1155 dated 01/10/20 approved by Ishaq I. Chanda, P.E, expiring 04/14/21expiring 04/07/25.