Loading...
HomeMy WebLinkAboutAPPROVED, 20-0114.09NOA No. 21-0114.09 Expiration Date: March 20, 2024 Approval Date: March 18, 20 21 Page 1 MIAMI -DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy ECO Windows Systems, LLC 9114 N. W. 106th Street, Medley, FL 33178 S COPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER re serves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein and h as been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series “700” Aluminum Sliding Glass Door w/ Reinforcements-S.M.I. APPROVAL DOCUMENT: Drawing No. W13-60 REV E, titled “Series- 700 Alum SLD. Glass Door (S.M.I.)”, sheets 1 through 8 of 8, prepared by Al-Farooq Corporation, dated 11/22/13 and last revised on JAN 12, 20 21, signed and sealed by Jalal Farooq, P.E., bearing the Miami-Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING: Small Missile Impact Resistant Limitations: 1.See Design Pressures Vs Reinforcing, glass types and anchor capacity charts in sheet 2. Exterior (posi tive) design pressures are limited to +70 PSF w / 2-3/4 ” sill riser and +47.0 PSF w/ 2” sill riser. Lower design Pressure from charts applies to entire system. 2.See approved configurations in sheets 1. The max frame width and height not to exceed 96”. 3.See fix jamb installation clip #19 (3” corner and 16” OC) in sheet 5. 4.See low-e insulated laminated glass test lab reported data(s) for thermal performance , listed in sheet G -1, such application to be reviewed by Building Official. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and series and following statement: "Miami-Dade County Product Control Approved", noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in th e a pplicable b uilding code n egatively affecting th e p erformance o f th is p roduct. TERMINATION of th is NOA will occur after th e e xpiration d ate o r if th ere h as b een a revision o r change in th e materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising o r any o ther p urposes shall automatically terminate th is NOA. Failure to c omply with any section o f th is NOA s hall be c ause for termination a nd removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade Co unty, Florida, an d f ollowed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises #18-1220.10 consists of this page 1 and evidence pages E-1, E-2, E-3 and E-4, as well as approval document mentioned above. The submitted documentation was reviewed by Ishaq I. Chanda, P.E. #1F Ishaq I. Chanda, P.E. Product Control Unit Supervisor NOA No. 21-0114.09 Expiration Date: March 20, 2024 Approval Date: March 18, 20 21 E-1 ECO Windows Systems, LLC NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1.Evidence submitted under previous approvals A. DRAWINGS 1.Manufacturer's die drawings and sections (submitted under file # see below) 2. Drawing No. W13-60 REV C, titled “Series- 700 Alum SLD. Glass Door (S.M.I.)”, sheets 1 through 8 of 8, prepared by Al-Farooq Corporation, dated 11/22/13 and last revised on JAN 28, 2016, signed and sealed by Javad Ahmad, P.E. B. TESTS (Submitted under #13-1217.23) 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3)Water Resistance Test, per FBC, TAS 202-94 4)Small Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411 3.2.1, TAS 202-94 along with marked -up drawings and installation diagrams of Alum sliding Glass doors, prepared by Fenestration Testing Lab, Inc., Test Report No. FTL-7405 dated 09/13/2013 and last revised on 02/10/2014, signed and sealed by Marlin D. Brinson, P. E. Note: The above referenced test report has an addendum letter dated FEB 10, 2014, issued by Fenestration Testing Lab, Inc., signed by Ms. Iliana Sanchez, test report Author. C. CALCULATIONS 1.Anchor verification calculations and structural analysis, complying wit h FBC-2014 (5th Ed it ion), prepared by Al Farooq Corporation, dated 06/10/1 5 and last revised on JAN 28, 2015, signed and sealed by Javad Ahmad, P.E. 2.Glazing complies w/ ASTME-1300-02 , -04 & -09. D.QUALITY ASSURANCE 1.Miami Dade Department of Regulatory and Economic Resources (RER). E.MATERIAL CERTIFICATIONS 1.Notice of Acceptance No. 14-0916.10 issued to Kuraray America, Inc. (Former E.I. DuPont DeNemours & Co., Inc.) for the “Kurray Butacite PVB Interlayers”, expiring on 12/11/2016. F.STATEMENTS 1.Statement letter of conformance to FBC 2014 (5th edition) and letter of no financial interest, prepared by Al Farooq Corporation, dated 06/10/15, signed and sealed by Javad Ahmad, P.E. 2.Lab compliance as part of the above referenced test report. G.OTHER 1.Test proposal, d at ed 03/25/13 approved by Jaime D. Gascon, P.E. Ishaq I. Chanda, P.E. Product Control Unit Supervisor NOA No. 21-0114.09 Expiration Date: March 20, 2024 Approval Date: March 18, 20 21 E-2 ECO Windows Systems, LLC NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED G.OTHER (Continue) (Submitted under #13-1217.23) 2.Thermal Simulation Test report # FTL 7605 dated 11/12/2013, issued by Fenestration Test ing Lab to validate the U-Factor and SHGC attributes, using NFRC procedures and computer Software listed below: 2.1) NFRC 100-2004 “Procedure for Determining Fenestration Product U-Factors”. 2.2) NFRC 200-2004 “Procedure for Determining Fenestration Product Solar Heat Gain Coefficient and Visible Transmittance at Normal Incidence”. 2.3) NFRC 500-2004 “Procedure for Determining Fenestration Product Condensation Resistance Values”. 2.4) Computer simulation Software Therm 6.3.38 Window v6.3.74, simulation manual. Along with marked -up drawings of 96” Wx96”H (OX) alum Sliding glass door, with insulated laminated low -e glass (3/16 LowE336-3/8 AIR gap-3/16CLR-060 PVB -3/16CLR), simulation conducted by Jose Sanchez (NFRC Certified Simulator-in Responsible Charge). 3.Thermal Performance Test Report # FTL 7606 dated 11/13/2013, issued by Fenestration Testing Lab for measured Test data and calculated Test data per NFRC procedure below : 3.1) NFRC 102-2004 “Test Procedure for Measuring the Steady State Thermal Trans mittance of Fenestration Systems”. Along with marked -up drawings of 96” Wx96”H (OX) alum Sliding glass door, with insulated laminated low -e glass w/ SS-D (3/16 T LowE336-3/8 AIR gap-3/16HS-060 PVB -3/16HS), test conducted by Jose Sanchez (NFRC Certified Simulator-in Responsible Charge). GREEN SUSTAINABLE ATTRIBUTES (GSA) SCOPE: This document is solely for the purpose of test lab report ed Sustainable Attributes of construction materials. The documentation s under items G (2) & (3) have been provided to Miami-Dade County Product Control Section. Te sted Baseline sample: Max 96” W X 96” H Alum SGD (OX) w/ (Low-e Insulated laminated Glass w/SS-D). Max DLO 87 -15/16” H x 41-3/4” W per each panel. Overall Panel size 48-7/8”H x 94-7/16” W G.8 – U-FACTOR (THERMAL TRANSMITTANCE ) BTU/HR-FT2 -0 F G.9 – SHGC -FACTOR (SOLAR HEAT G AIN COEFFICIENT ) BTU/HR-FT2 ID# Test Report# Product Number Glazing Components: G.8 U-Factor G.9 SHGC Base line Product FTL- 7605 001 3/16 LowE336-3/8 AIR gap -3/16CLR-060 PVB -3/16CLR 0.60 Tota l 0.22 Total (NG) Legend Abbreviations: Description: SS-D Desiccant-Filled Stainless -Steel Spacer 360#2 Cardinal Low E 336(e=0.022) @ #2 Surface AIR Pure Air Space PVB .0 60” Poly Vinyl Butral (PVB) interlayer CLR Clear Glass T Tempered HS Hea t Strengthened NG Non -Grid AL Aluminum Frame (Non-Thermally Broken) Ishaq I. Chanda, P.E. Product Control Unit Supervisor NOA No. 21-0114.09 Expiration Date: March 20, 2024 Approval Date: March 18, 20 21 E-3 ECO Windows Systems, LLC NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2.Evidence submitted under previous approvals. A. DRAWINGS 1. Drawing No. W13-60 REV D, titled “Series- 700 Alum SLD. Glass Door (S.M.I.)”, sheets 1 through 8 of 8, prepared by Al-Farooq Corporation, dated 11/22/13 and last revised on JAN 23, 2018, signed and sealed by Javad Ahmad, P.E. B. TESTS 1. None. C. CALCULATIONS 1. None. D.QUALITY ASSURANCE 1.Miami Dade Depart ment of Regulatory and Economic Resources (RER). E.MATERIAL CERTIFICATIONS 1.Notice of Acceptance No. 16-1117.01 issued to Kuraray America, Inc. (former E.I. DuPont DeNemours & Co., Inc.) for “Trosifol: Ultra clear, clear & color PVB glass interlayer” (former “Kuraray Butacite PVB Interlayer)”, expiring on 07/08/19. F.STATEMENTS 1.Statement letter of conformance to FBC 2017(6th edition) prepared by Al-Farooq Corporation, dated JAN 23, 2018, signed and sealed by Javad Ahmad, P.E. G.OTHER 1. This N OA revises NOA # 15-0612.04 , e xpiring 0 3/20/2019. 3.Evidence submitted under previous approval. A. DRAWINGS 1. Drawing No. W13-60 REV D, titled “Series- 700 Alum SLD. Glass Door (S.M.I.)”, sheets 1 through 8 of 8, prepared by Al-Farooq Corporation, dated 11/22/13 and last revised on JAN 23, 2018, signed and sealed by Javad Ahmad, P.E. B. TESTS 1. None. C. CALCULATIONS 1. None. D.QUALITY ASSURANCE 1.Miami Dade Department of Regulatory and Economic Resources (RER). E.MATERIAL CERTIFICATIONS 1.Notice of Acceptance No. 16-1117.01 issued to Kuraray America, Inc. (former E.I. DuPont DeNemours & Co., Inc.) for “Trosifol: Ultra clear, clear & color PVB glass interlayer” (former “Kuraray Butacite PVB Interlayer)”, expiring on 07/08/19. F.STATEMENTS (submitted under file #18-0129.12) 1.Statement letter of conformance to FBC 2017(6th edition) prepared by Al-Farooq Corporation, dated JAN 23, 2018, signed and sealed by Javad Ahmad, P.E. G.OTHER 1. This NOA revises NOA # 18-0129.12 , e xpiring 03/20/20 24. Ishaq I. Chanda, P.E. Product Control Unit Supervisor NOA No. 21-0114.09 Expiration Date: March 20, 2024 Approval Date: March 18, 20 21 E-4 ECO Windows Systems, LLC NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 4.New Evidence submitted. A.DRAWINGS 1.Drawing No. W13-60 REV E, titled “Series- 700 Alum SLD. Glass Door (S.M.I.)”, sheets 1 through 8 of 8, prepared by Al-Farooq Corporation, dated 11/22/13 and last revised on JAN 12, 2021, signed and sealed by Jalal Farooq, P.E. B. TESTS 1.None. C. CALCULATIONS 1.Anchor verification calculations and structural analysis, complying with FBC-2020 (7th Edition), prepared by Al Farooq Corporation, dated 01/12/21, signed and sealed by Jalal Farooq, P.E. D.QUALITY ASSURANCE 1.Miami Dade Department of Regulatory and Economic Resources (RER). E.MATERIAL CERTIFICATIONS 1.Notice of Acceptance No. 20-0915.28 issued to Kuraray America, Inc. (former E.I. DuPont DE Nemours & Co., Inc.) for “Trosifol: Ultra clear, clear & color PVB glass interlayer” (former “Kuraray Butacite PVB Interlayer)”, expiring on 07/08/24. F.STATEMENTS 1.Statement letter of conformance to FBC 2020(7th edition) prepared by Al-Farooq Corporation, dated JAN 12, 2021, signed and sealed by Jalal Farooq, P.E. G.OTHER 1.This NOA revises NOA # 18-1220.10, expiring 03/20/2024.