Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Transfer switch specs
1 of 2 *Built in the USA using domestic and foreign parts Service and non-Service rated Automatic Smart Transfer Switches Automatic Transfer Switches® Automatic Transfer Switches 100 - 400 Amps, Single Phase Description Generac Automatic Transfer Switches are designed for use with single phase generators that utilize an Evolution™ or Nexus™ Controller. The 100, 200, and 400 amp open transition switches are available in single phase in both service equipment rated and non-service equipment rated configurations. The 150 and 300 amp open transition switches are only available in a service rated equipment configuration. Standard Features Service rated (RXSW) Generac Automatic Transfer Switches are housed in an aluminum NEMA/UL Type 3R enclosure*, with electrostatically applied and baked powder paint. The Heavy Duty Generac Contactor is a UL recognized device, designed for years of service. The controller at the generator handles all the timing, sensing, exercising functions, and transfer commands. All switches are covered by a 5 year limited warranty. * Non-service rated (RXSC) switches are housed in a steel enclosure. DPM Technology Through the use of digital power technology (DPM), these switches have the capability to manage up to 4 individual HVAC (24 VAC controlled) loads with no additional hardware. When used in tandem with Smart Management Modules, up to 8 more loads can be managed as well, providing the most installation efficient power management options available. *CUL only applies to non-service rated switches ISO 9001:2008 2 of 2 Functions Dimensions ®Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com ©2017 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 10000013459-A 04/24/17 100-400 Amps, Single Phase Automatic Smart Transfer Switches ® All timing and sensing functions originate in the generator controller Utility voltage drop-out ......................................................................................................................................................................................................................<65% Timer to generator start ..................................................................................................10 second factory set, adjustable between 2-1500 seconds by a qualified dealer* Engine warm up delay .................................................................................................................................................................................................................5 seconds Standby voltage sensor ..................................................................................................................................................................................................65% for 5 seconds Utility voltage pickup .........................................................................................................................................................................................................................>80% Re-transfer time delay ...............................................................................................................................................................................................................15 seconds Engine cool-down timer ............................................................................................................................................................................................................60 seconds Exerciser ..............................................................................................................................................................5 or 12 minutes adjustable weekly/Bi-weekly/Monthly** The transfer switch can be operated manually without power applied. *When used in conjunction with units utilizing Evolution™ controls **Adjustable via the controller Specifications H2 DEPTH H1 W2 W1 H2 DEPTH H1 W2 W1 Model RXSC100A3 RXSW100A3 RXSW150A3 RXSC200A3 RXSW200A3 RXSW300A3 RXSC400A3 RXSW400A3 Height (in./mm) H1 17.24/437.9 17.24/437.9 26.75/679.4 17.24/437.9 26.75/679.4 42.91/1089.9 31.25/793.8 42.91/1089.9 H2 20/508 20/508 30/762 20/508 30/762 48/1219.2 36/914.4 48/1219.2 Width (in./mm) W1 12.5/317.5 12.5/317.5 10.5/266.7 12.5/317.5 10.5/266.7 16.69/423.9 19.18/487.2 16.69/423.9 W2 14.6/370.8 14.6/370.8 13.5/342.9 14.6/370.8 13.5/342.9 21.82/554.2 24/609.6 21.82/554.2 Depth (in./mm)7.09/180.1 7.09/180.1 6.3/160.1 7.09/180.1 6.3/160.1 10.06/255.5 10.06/255.5 10.06/255.5 Weight (lbs./kilos)20/9.07 22.5/10.21 39/17.69 20/9.07 39/17.69 140/63.5 133/60.33 140/63.5 Model RXSC100A3 RXSW100A3 RXSW150A3 RXSC200A3 RXSW200A3 RXSW300A3 RXSC400A3 RXSW400A3 Amps 100 100 150 200 200 300 400 400 Voltage 120/240, 1ø 120/240, 1ø 120/240, 1ø 120/240, 1ø 120/240, 1ø 120/240, 1ø 120/240, 1ø 120/240, 1ø Load Transition Type (Automatic) Open Transition Open Transition Service Rated Open Transition Service Rated Open Transition Open Transition Service Rated Open Transition Service Rated Open Transition Open Transition Service Rated Enclosure Type NEMA/UL 3R NEMA/UL 3R NEMA/UL 3R NEMA/UL 3R NEMA/UL 3R NEMA/UL 3R NEMA/UL 3R NEMA/UL 3R UL Rating UL/CUL UL UL UL/CUL UL UL UL/CUL UL Withstand Rating (Amps)10,000 10,000 22,000 10,000 22,000 22,000 22,000 22,000 Lug Range 1/0 - #14 250 MCM - #6 600 MCM - #4 or 1/0 - 250 MCMAutomatic Transfer Switches