HomeMy WebLinkAboutAPPROVED, REVISION, CHG UNDERLAYMENTSOFFICE USE ONLY: DATE FILED• REVISION FEE: PERMIT # RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 (772) 462-1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION LOCATION/SITS ADDRESS: 7104 CABANA LN , FORT PIERCE, FL 34951 DETAILED DESCRIPTION OF PROJECT REVISIONS: Instead of using a synthetic underlayment NOA1 871­109.03 (Gator Skin-1 0) we will be using FL1 1602.1 Titanium PSU 30 which is a self adhering underlayment. CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: CCC1326977 BUSINESS NAME: ST,, LUCIE CO CERT. #0a Modtek Roofing Inc QUALIFIERS NAME: Luke McConnell ADDRESS: 1360 Old Dixie Hwy SW Ste 103, CITY: Vero Beach STATE, FL ZIP-,32962 PHONE (DAYTIME): 772-213,8437 FAX: NA OWNER/BUILDER INFORMATION° NAME: Michael Dorris ADDRESS: 7104 Cabana Ln. CITY: Ft. Pierce, STATE: FL ZIP: 34951 PHONE (DAYTIME: 732-22lm6679 ply; NA ARCHITECT/ENGINEEI2 INFORMATION. NAME: NA ADDRESS: NA CITY: NA STATE: NA ZIP: NA PHONE (DAYTIME): NA FAX: NA SLCCC.m 9123109 Revised 0613 0/17 TRINITY -ERD EVALUATION REPORT Interwrap, Inc. 32923 Mission Way Mission, BC V2V=GE4 Canada SCOPER. EXTERIOR RESEARCH & DESIGN, PLC. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 :g;;D, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 Evaluation Report I11980.11.08 FL1 1602 Date of Issuance: 11/03/7.008 This Evaluation Report is issued under Rule 9B-72 and the applicable rules and regulations governing the use of construction materials in the State of Florida. the documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential volume. The products described herein have been designed to comply with the 2007 Florida Building Code. DESCRIPTIOWn TitanjUMTm Roof Underlayments LABELING: Each unit shaft bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen,, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinitylERD requires a complete review of this Evaluation Repots relative to updated Code requirements with each Code Cycle. ADVERTISEMENT. The Evaluation Report number preceded by the words "TrinityIERD Evaluated," may be displayed in advertising literature,, If any portion of the Evaluation Report is displayed,, then it shall be done in its entirety. INSPECTION; Upon request, a copy o the manufacturer or ids distributors request of the Building Official. f this entire Evaluation Report shall be provided to the user by and sham be available for inspection at the jab site at the this Evaluation Report consists of pages 1 through 5. Prepared by: Robert J.M. Nleminen, P.E. Florida Registration No. 59.156, Florida DCA ANE1983 � 5 5 The facsimile seal appearing was authorized by Robert l ieminen. F.E. on 11 00 This does not serve as an elecLronically signed document. Signed, sealed hardcoples have been transmitted to the product Approval Administrator and to the named client CERTIFICATION F INDEPENID04 E* 1- Trinit l RD does not have, nor does it intend to acquire or will it acquire, a flnan i l interest in any company manufacturing turing or distributing products it evaluates. . TrinitylERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. . Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company nufacturing or distributing products for which the evaluation reports are being issued. . Robert Niel in n, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. f: LA TRO.-I RoOFING COMPONENT E"LUAT90H.Z] im 2. 3. SCOPE: E R !17 �` 1 " Product Category: Roofing Sub -Category; Underlayment Compliance Statement: Titaniu M Tm Roof Underlayments, as produced by Interwrap,, Inc., have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. STANDARDS. Section 1507.7.31 T1507.8111507.8-3, 1 . .3, 1507.9.4 1-. .3 REFERENCESM Entity ITS (TST1509) ITS (TST1509) ITS (TST1509) ITS (QUA1673) 4. PRO UCT DESCRIPTION: 4I. �. _ Self -Adhering U t Pro.Llerly Physical Properties Physical Properties Examination Physical Properties Physical Properties Physical Properties Quality Control nt , Standard Year ASTM D225 1997 ASTM D19701 Reference Date 3146738CQQ-003A 03/28/2008 3146738C(?Q-003 B 03/28/2008 3126617COQ-405 10/31/2007 Email confirmation 09/11/2008 74.1.1 � T i t a n i UMTM PSU 30 is an unreinfvrced polymer modified bitumen material adhered underside of apolymer-coated, synthetic woven sheet. The underside is backed with a film. Unit weight 24 lbs/square. 4.2 Mechanical) :erred Undertayments: to the release 4-2A Titani UMTM UDL-25 is a synthetic sheet -type underlayment comprised of a woven core cowed on one side with a polymer coating. Unit weight 2.9 lbs/square. 4.2.E TitaniumT"' UDL-30 *is a synthetic sheep -type underlayment comprised of a woven core coated on both sides with a polymer coating. Unit weight 4,.0 lbs/square. 4.2.3 Titanium" UDL=50 is a synthetic sheet -type underlayment comprised of a woven core cowed on both sides with a polymer crating. Unit weight 4.7 lbs/square. 4.2.4 Titaniu MTM UDL-TT is a synthetic sheet -type underlayment comprised of a woven core coated on one side with a polymer coating. unit weight 2.9 lbs/square 4.2.5 Titanium -I"' UDL=TF is a synthetic sheet -type underlayment comprised of a woven core coated on both sides with a polymer coating. Unit weight 2.9 lbs/square. S. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVHZ,, 5,2 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design,, LLC. Certificate of Authorization Evaluation Report I11980.11a08 FL11602 Date of 1ssuance: 1110312009 TRINITY..:. ERD 5.3 Titaniu MTM Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within F13CdPPFQVdl documents. If not hsted,, a request may be made to the AHJ for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.4 Allowable roof covers applied atop Titani UMTm Roof Underlayments are follows: Asphalt Foam -On Underlayment Shingles Nails -on Tile 'isle Metal Wood Shakes & Shingles slate _ (See 5.4,1) PSU 30 Yes Yes Yes � Yes Yes Yes UDL 25 Yes Yes No Yes � Yes Yes UDL 34 Yes Yes No Yes Yes Yes UDL 50 Yes Yes No Yes Yes Yes UAL TT Yes Yes No Yes Yes Yes UDL TF Yes Yes Na Yes Yes Yes 5.4.1 "Foam -On Tile"" is limited to use of Polyfoam Polyset or Dow Tile Bond applications unless data from an accredited testing Laboratory for alternate foam -adhesive with the subject underlayment in accordance with ICC.-ES AC152 is provided. 5n4m2 For file roof installations governed by the FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition,, use is limited to the following: Mechanically Fastened Tile with PSU 30; ➢ System 1,, Option 5 or 6, Section 3,02E or F in place of "Self -Adhered Underlayment" ➢ System Z, Option 4 or 5, Section 3.02D or E in place of ""Self -Adhered Underfayment 14F MPrhanirally Facfpnar4 Tiles %AM-h "MI 7q: t ini -:)n "r%i M1 _,-r 1> Syst ..c...� . aw .��.r� [�a,� � ■�L. vv1i.� I vcJL LJ V LJL JU lJ #JL �V V em 1, Option 4, Section 3.02D in place of "No. 30". Mechanically Fastened Tile with UDL / PSU Two -Ply System: r System x, Option 6, Section 3.02F in place of "No. 30"' and "Self -Adhered Underpayment" System 2, Option 5,, Section 3.02E in place of "No. 30"' and "Self -Adhered Underlayment" Adhesive -Set- Tile with PSU 30: System 4, Option A4 or A5, Sections 3.02D or E in place of "Self -Adhered Underlayment" );--- System 4, Option B3 or B4. Sections 3-02C or D in place of "Self -Adhered Underlayment" 5,15 Allowable substrates for self -adhering underiayments are noted below: 5s5ml PSU 30 Self -Adhering Direct -Bond to Deck: ➢ New untreated plywood; );> Existing untreated plywood, primed as needed with Doi primer to achieve bond. 5.5.E PSU 30 Self -Adhering Bond to Mechanically Attached Base Underlayment: ➢ ASTM D226, Type I or II felt. 5m6 Instal self -adhering underlayments when ambient and surface temperatures are minimum 40°F and rising. 5v7 Titanium Roof Underlayments shall not be left exposed for longer than 30-days after installation. Exterior Research and Design.. ry.. LL _ Certificate of Authorization #9503 Evaluation Report 3EILIL980.11,08 FL11602 Date of Issuance; I I RVA 6a INSTALLATIONS 6alTitanium Roof Underlaymen�s shall be installed in accordance with Interwrap publi shed installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and premed the substrate (if applicable), 6.3 TitaniUMTM PSU 3091 6.3.1 PSU 30 shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.3 d, 2 For use in non -lice applications: 63.2.1 Cut to 10- to 15-foot manageable sections and re -roll with the release from side out. 6.3-2.2 Membrane Application. v Peel back release film approximately 1 to Z feet and align with the lower edge of the roof and set in place, printed side up. ➢ Apply the balance of the membrane to the substrate by removing the film and firmly pressing the membrane into place. �> Apply subsequent courses parallel to the eave in a shingle -type, water -shedding manner. ➢ End (vertical) daps shall be minimum 12-inches and side (horizontal) daps shall be minimum 3-inches,, )ip, If the membrane becomes misaligned, cut the roll and re -start. Jo- Upon completion, inspect the membrane and repair any defects or fish -mouths. 63.3 For use in tile applications, reference is made to FRSA/TRI 07320/8-05 Installation Manual,, Fourth Edition, and Section 5.4.3 herein,. using the instruct -ions noted above as a guideline. 6,33al Wait a minimum of 24 hours prior to loading roof tikes. 6,112 Tiles shall be staged so as to avoid slippage and/or damage to the roof underlayment. 6.4 Titanium "' UDL=25,r UDLm301 UDL-501, UDL-TT and UDLwwTFn 6o4ml Install in compliance with manufacturer's Published installation instructions and the requirements for ASTM D226,r Type I and TI underlayments, respectively, in FRC Sections IS07 for the type of prepared roof covering to be installed. 6,4,1,ol End (vertical) laps shall be minimum 6-inches and side (horizontal) laps shall be minimum 4- inches. 6.4-1.2 Mechanical attachment of UDL-25 and UDL-30 is limited to ring shank roofing nails with minimum 1-inch diameter plastic caps. 6.4.13 Mechanical attachment of UDL-50,, UDL-TT and UDL-TF is limited to ring shank roofing nails with minimum 3/8-inch diameter heads; ring shank roofing nails with minimum 1-inch diameter plastic caps; screws and plates; or plastic cap staples. 6w4m 1.4 Minimum attachment shall be 12�-'Jnches o.c. vertically and 24-inches o.c. horizontally in accordance with the surface markings on the exposed face of the under#ayment. When batten systems are to be installed atop the underlayment, the underpayment need only be preliminarily attached pending attachment of the battens. Exterior Research and Design, LL . Certificate ofAuthorization Evaluation [deport 111980,.11.08 FL11602 Date of Issuance: i i TA N 'ell y5 714 TR N-ITY KL.:,) 6s4m2 For use in non -tile ap plications, reference is made to the current edition of the NRCA Steep - slope Roofing Manual. 6v4-3 For use in tide a lications, reference is made to FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Section 5,4.1 herein, 6.4.3.1 Titani UMTM UDL underiayments are 48--inches wide; wider than the typical, codified 36-inch wide ASTM D226, Type I and Il underlayment. FRSA/TRI references to attachment shall be maintained on a proportional basis relative to the wider sheep. 7o LABIELINGa. Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. Be BUILDING PERMIT REQUIREMENTS2 As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 91, MANUFACTURING PLANTS: Mission, B.C. - Canada ion QUALITY ASSURANCE ENTITY: Intertek Testing services NA Inc. -ETL/Warnock Hersey - QUA1673 - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Certificate hori aLion #9503 Evaluation Report 11.1980.11,08 FLiffiO2