HomeMy WebLinkAboutAPPROVED Product Approval, Soprema-TriBuilt Smooth HT-FL Appovals.pdf1/21/2021 Florida Building Code Online
Business . Professional
BQS Horne Log In User Registration Hat Topics Submit Surcharge Stats & Facts Publications contact Us BaS Site Map Links Search
dprbO
Product Approval
USER: Public User
Produa Approval Menu > Product
or Application Search a ARRqgtLi2in Ijg > Application Detail
FL #
FL2569-R20
Application Type
Revision
Code Version
2020
Application Status
Approved
Comments
Archived
Product Manufacturer Soprema, Inc. (Canada)
Address/Phone/Email 1640 rue Haggarty
Drummondville, NON -US 00000
(819)478-2400
memathieu@soprema.ca
Authorized Signature Marc -Etienne Mathieu
memathieu@soprema.ca
Technical Representative Marc -Etienne Mathieu
Address/Phone/Email 1688 Jean-Berch mans- M icha ud
Drummondville, NON -US 00000
(819) 478-2400 Ext3327
memathieu@soprema.ca
Quality Assurance Representative
Jean -Francois Cote, Ph.D.
Address/Phone/Email
1640 rue Haggarty
Drummondville
(888)811-3145
jfcote@soprema.ca
Category
Roofing
Subcategory
Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J. M. Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 04/10/2023
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FL2569 R 0 O
Referenced Standard and Year (of Standard) Standard
Year
ASTM D1970
2015
ASTM D4798
2011
ASTM D6163
2015
FM 4474
2011
FRSA/TRI Sixth Edition
2018
UL1897
2012
https://www.floridabuilding.orglpr/pr_app_dtl.aspx?param=wGEVXQwtDgsKOFEnGkB108ErxlUd3xYlmjtmBrpDan9H30QGunUKXA°/a3d%3d 1/2
1/21/2021
Florida Building Code Online
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
09/19/2020
Date Validated
09/22/2020
Date Pending FBC Approval
09/29/2020
Date Approved
12/15/2020
Date Revised
12/16/2020
FL At Model, Number or Name
2569.1 Sophisms Roof Underiayments
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-150
Other: 1.) Refer to ER Section 5 for Limits of Use. 2.) The
design pressure noted herein pertains to underiayment systems
used beneath adhesive -set tile systems. Refer to ER Section
5.6.4 for details.
Description
Self adhering roof underlayments
Installation Instructions
FI 2569 R20 II 2020 09 17 FINAL ER FL2569-R20 odf
Verified By: Robert Nieminen, P.E. PE-59166
Created by Independent Third Party: Yes
Evaluation Reports
FL2569 R20 AE 2020 09 17 FINAL ER FL2569-R20 gAff
Created by Independent Third Party: Yes
Oack El
correct Us :: 2601 Blair some Road Tallahassee FL 32399 Phone: 850-487-1824
The state of Ronda is an AA/EEO employer. Convraht 2007-2013 State of Florlda. : privacy Statement :: Accessibility statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entry. Instead, contact the office by phone or by traditional mail. It you nave any questions, please corset 850.487.1395. 'Pursuant to section 455.275(1),
Florida Statutes, eBecbve Dctober 1, 2012, licensees licensed under chapter 455, F.S. must provide Me Department with an email address If May have one. The emalls
provided! may be used for official communication with Me licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to Me public. To determine if you am a licensee under chapter 455, F.S., please tick be.
Product Approval Acceptant
MWI ® e: r«
Credit Card
Safe
hftps://www.floddabuilding.org/prIpT_app_M.aspx?param=wGEVXQwtDgsKQFEnckBlOSErxl Ud3xYlmjtmBrpDan9H30OGunUKXAa/o3d%3d 212
NEMO I etc.
Certificate of Authorization A32455
353 Christian Street, Unit 913
Oxford, CT 06478
0 (203) 262-9245
ENGINEER EVALUATE TEST CONSULT
Soprema, Inc.
1640 rue Haggerty
Drummondville, Qudbec 12C 5PB Canada
(819)478-2400
Evaluation Report S18010.06.09-R19
FL2569-R21
Date of Issuance: 06/15/2009
Revision 19: 12/16/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the TN Edition (2020) Florida Building Code sections noted herein.
DESCRIPTION: Soprema Roof Underlayments
LAaEUNG: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.1.1.
CONTINUED CoMpuAi This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOIetc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer
or its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 9.
Prepared by:
Robert JI M. Nieminen, P.E.
Florida Registration No. 59166. Florida DCA ANE1983
:s ,k,
Mks latumik seal apm,,.g was autherned by xobert
_ Nmkrnn , P I on 12/16/2020 inks does not serve as
an eiectronKaliv vgnia ooEument
CERTInrAr10N of INDEPENDEIIEE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire. a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are. in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
02019 NEMO ETC, LLC
NNEMO I etc.
ROOFING COMPONENT EVALUATION:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Soprema Roof Underlayments, as produced by Soprema, have demonstrated compliance
with the following sections of the r Edition (2020) Florida Building Code through testing in accordance with the
following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use
set forth herein.
Section
Probe
Standard
Year
1504.3.1
Wind resistance
FM 4474
2011
1504.3.1
Wind resistance
UL 1897
2015
1507.1.1, 1507.2.4, 1507.2.9.2
Material standard
ASTM D1970
2015
/ R905.1.1, R905.2.8.2
1507.3.3 / R905.3.3
Material standard
FRSA/TRI, Sixth Edition
2018
1507.11.2 / R905.11.2
Material standard
ASTM D6163
2015
TAS 110
Accelerated Weathering
ASTM D4798
2011
Entity
Examination
Rehrente
Daft
ERD (TST6049)
Wind Resistance
2779.07.05
07/15/2005
ERD (TST6049)
ASTM D1970 / TAS 110 (QC)
S31370.03.30.1-R1
04/07/2010
ERD (TST6049)
FRSA/TRI 04-12(OH)
S31150.05.09-R2
10/05/2010
ERO(TST6049)
ASTM D1970 (OH)
S37210.11.11
11/09/2011
ERD (TST6049)
ASTM D1970(MSI
S37210.12.11
12/01/2011
ERD (TST6049)
ASTM D1970 (MS)
S40540.02.13-1
02/19/2013
ERD (TST6049)
FRSA/TRI 04-12 (MS)
S43530.02.14-1-R1
02/21/2014
FRO (TST6049)
ASTM D1970(BC)
544870.04.14-2
04/02/2014
ERD (TST6049)
ASTM D1970 [QC)
$44870,04.14-3
04/02/2014
ERD (TST6049)
ASTM D1970 (OH)
S44870.04.14-1
D4/30/2014
ERD (TST6D49)
ASTM D1970 (MS)
S44870.04.14.4
04/10/2014
ERD (TST6D49)
ASTM D1970 (OH)
S40540.10.14
10/31/2014
ERD (TST6049)
Tensile Adhesion / Long Term Aging
SOPC-SC7645.02.15
02/13/2015
ERD (TST6049)
Accelerated Weathering
SOPC-SC8520.04.14
D4/27/2015
ERD (TST6D49)
Wind Resistance
SOPC-SC14045.05.17-RI
06/07/2017
M-0 (CER1592)
HVHZ Compliance
18-0329.03
06/28/2019
ICC-ES(EVL2396)
20151BC Compliance
ESR-1524
03/01/2017
NEMO (TST6049)
ASTM D1970 / TAS 1101QC)
5OPC-SC8970.08.15-RI
04/25/2018
NEMO (TST6049)
Wind Resistance
4-SOPC-18-003.08.18
09/27/2019
NEMO (TST6049)
ASTM D4798/D3970 (OH & MS)
45-SOPC-18-002.05.19.A
05/31/2019
NEMO (TST6049)
Tensile Adhesion/Long Term Aging
4p-DOW-I9-SSLAP-DI.A.R2
02/10/2020
NEMO (TST6049)
Peel adhesion (existing underlayments)
4j-SOPC-I9-SSUDL-04.A
03/12/2020
NEMO (TST6049)
Peel adhesion (existing underlayments)
4j-SOPC-20-SSUDL-01
12/16/2020
PRI(TST5878)
ASTM D1970 MS)
SOP-064.02-01
12/03/2013
Soprema, Inc. (PDM35111
Equivalency Declaration
SA SMOOTH PLY 40
06/29/2015
UL, LLC (QUA9625)
Quality Control
MLA File No. R16814
12/10/2015
UL, LLC (QUA9625)
Quality Control
MLA File No. R27605
05/08/2019
UL, LLC (QUA9625)
Quality Control
Service Confirmation
06/29/2020
UL, LLC (QUA9625)
Quality Control
Florida BCIS
Current
NEMO ETC, LLC Evaluation Report S38010.06.09-1119
Cenlfirate ofAathonTOM1on a32455 7 "EDITION 12020) FBC NON.HVHZ EVALUATION FUS69-1121
Sopmma Roof Underlaymentx Revision 19: 12/15/2020
Page 2 of 9
M
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
4.9
4.10
4.11
4.12
4.13
4,14
4.15
4.16
ONEMO I etc.
PnooucT DESCRIPTION:
Product
Material
Plant(s)
Description —
Standard
Lastobond TU HT
ASTM D1970 and Gulfport, MS
self -adhering, non -woven polyester fabric
FRSA/TRI 09.18
surfaced. SBS modified bitumen roof
underlayment
Tri-Built S/A HT TU
ASTM D1970 and Gulfport, MS
self -adhering, non -woven polyester fabric
Underiayment
FRSA/TRI 09-18
surfaced, SBS modified bitumen roof
underlayment
Lastobond Shield
ASTM D1970 Drummondville, QC
self -adhering, woven polyethylene surfaced, SBS
modified bitumen roof underlayment available In
two widths; 36 and 45 inch
RESISTO SA SMOOTH PLY
ASTM D1970 Drummondville. QC
self -adhering, woven polyethylene surfaced, SBS
40
modified bitumen roof underlayment
Lastobond Shield HT
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof
underlayment
Lastobond Pro HT-N
ASTM D1970
I Drummondville, QC
self -adhering, woven polyethylene surfaced, SBS
modified bitumen roof underlayment available in
two widths; 36 and 45 inch
Lastobond Pro HT-S
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof
underlayment
Enviro5hield
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature. SBS modified bitumen roof
underlayment
Lastobond 195
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, sand -
Wadsworth, OR
surfaced, SBS modified bitumen roof
underlayment
Lastobond Eaves
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, sand -
Protection Sheet
Wadsworth. OH
surfaced. SBS modified bitumen roof
underlayment
Lastobond Eco
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
Gulfport, MS
surfaced. SBS modified bitumen roof
Wadsworth, OH
underlayment
Lastobond Smooth Seal
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, film -
HT
Wadsworth, OR
surfaced, SBS modified bitumen roof
underlayment
Tri-Built Smooth HE 5/A
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, film-
Underlayment
Wadsworth, OR
surfaced, SBS modified bitumen roof
underlayment
PrimeSource Grip -Rite
ASTM D1970
Gulfport. MS
self -adhering, glass -mat reinforced, film -
Smooth Seal HT
Wadsworth, OH
surfaced. SBS modified bitumen roof
underlayment
RE51STO L81236
ASTM D1970
Drummondville. QC
self -adhering, glass -mat reinforced, sand -
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
I underlayment
TRI-BUILT Sand-R SA
ASTM D1970
Drummondville. QC
self -adhering, glass -mat reinforced, sand -
Shingle Underlayment
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth. OH
underlayment
NEMO ETC, LLC Evaluation Report S19030.06.09-R19
Cernjtrmr of ♦uMO@ Wit r32455 7"EDITION (2020) FRc NON.HVHI EVALUATION FL2569-11121
Supreme Roof Underlayments Revision 19: 12/15/2020
Page 3 of 9
4.17
4.18
4.19
4.20
5.1
5.2
NNEMOletc.
Material
F4odtM
Plant(s)
Description
Standard
PrimeSource Grip -Rite
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand-
Eave & Valley Protector
Gulfport, MS
surfaced. SOS modified bitumen roof
Wadsworth, OH
underlayment
SRS TopShield ICE &
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
WATER DEFENDER
Gulfport, MS
surfaced, SOS modified bitumen roof
Wadsworth, OH
underlayment
RESISTO LB1244
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand.
Gulfport. MS
surfaced, SOS modified bitumen roof
Wadsworth, OH
underlayment
Colphene FR GR
ASTM D6163
Gulfport, MS
self -adhering, fiberglass reinforced, granule -
Wadsworth. OH
surfaced. SOS modified bitumen roof
underlayment
This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -
Dade Counties(.
5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.5 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers:
TABLE 1: RooF COVER Oprious
ra[stirdi
1517.2
1W..3
1W..4•1507s
1W..7
1W..aA1507.9
Clay and Concrete Tile
Clay
Metal
slate or
Asphalt
WoodSNkes or
Mechanical
Adhesive-
Panels
Shingles
Urkalaymem
Shingles
sate -Type
Shingles
Set
Shingles
Lastobond TU HT, Tn-Built S/A HT TU
Yes
Yes
Untleraymenl
Yes
Yes
see 5.6.1
Yes
Yes
Yes
1., 11nw. ISO, 1131
RIGS 1131
Lastabond shield, Pro HT-N. RESISTO SA
Yes
SMOOTH PLY 40
Yes
No
No
No
No
Yes
1p .1 w. ism 1 13 /
MsI131
Yes
LastobOnd shield HT, Pro HT-S
Yes
No
No
Yes
Yes
Yes
1p,m m,w. lsor 11 3 /
M1SOS 1111
Yes
EOvIfo$hwid
Yes
No
No
Yes
Yes
♦es
W'm.biw. 1", 113/
R90] 1 1 31
Lastobond Eaves Protwion Sheet.
Yes
lastatwnd 195
Yes
No
No
No
No
Yes
lwm nnw. 1sw113/
Ades 1131
NEMO ETC, LLC EVAIWtion Report 918030.06.09-1119
Certljcute ofAuthwavtim a32455 7"EDITION (2020)FBC NON-HVHZ EVALUATION FLZ569-R21
Soprama Roof Underayments Revision 19: 12/15/2020
Page 4 of 9
NNEM01letc.
TABLE 1: ROOF COVER OPTIONS -- -
racserdPa:
2502.2
1507.3
asm.4 Aums
1s07.1
any..$&15o29
flay and contrite Tile
Maui
SlateW
Wood Shakes or
Mechanical
"he,,_
Panels
Shingles
UnderkymeM
Shingles
Skte-Type
Shingles
Attach
set
Shingles
LastobDnd ECO, RESISTO LB1236. TRI-
BUILT Sand-R SA Shingle Underlayment,
Yes
Grill -Rite Eave & Valley Protector,
Yes
No
No
No
No
Yes
prim unp. ism 111 r
TopShield ICE & WATER DEFENDER,
it" I 1 a
RESISTO LB1244
Lastobond Smooth Seal HT, Trr. Built
Yes
Smooth HT S/A Underlayment, Grip -Rite
Yes
No
No
Yes
Yes
Yes
ipim nnp 150111 31
Smooth Seal HT
59115 1131
Yes
Colphene FR GR
Yes
Yes
No
No
No
Yes
I.. Imp. 15a1113/
19(i5113)
5.6.1 Adhesive -set tile is limited to use of the following Approved underlayment / tile -adhesive combinations.
TABLE SA: ALLOWABLE TILE ADHESIVE / UI4DERlAyMENT COMBINATK1NSs
Underlayment Adhesive Marlds Product Approval
Lastobond TU HT, Tr. -Built S/A Dupont'Tlle Bond"' Roof Tile Adhesive" FL22525
HT TU Underlayment ICP Adhesives and Sealants "Polyset• AH-160" FL6332
5.7 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERIATMENTS
Substrates (designed to meet wind loads for project)
Underlayment
Application
Type Primer Materiags)
Lastobond Shield, Lastobond Pro
(Optional) ASTM
plywood, OSB or Southern Yellow Pine
HT.N, RESISTO SA SMOOTH PLY
Deck /
D41, Elastocol Stick,
(SYPI
40, Lastobond Shield HT,
sheathing
Elastocol Stick Zero
ASTM D41
structural concrete
Lastobond Pro HT-S,
Enviro5hield, Lastobond TU HT,
Elastocol
Dens Deck Prime or SECUROCK Gypsum-
Tri-Built S/A HT TU
Insulation
Stick(Optionall
Zero
Stick Zero
Fiber Root Board
Underlayment, Lastobond Eaves
Protection Sheet, Lastobond 195, self-
Lastobond ECO, RESISTO L81236, adhering
TRI-BUILT Sand-R SA Shingle
Underlayment, Grip -Rite Eave &
Valley Protector, TopShield ICE &
Base Sheet
(Optionall Elastocol
ASTM D226, Type II felt or Modified Sopra-
WATER DEFENDER, RESISTO
Stick Zero
G
L81244, Lastobond Smooth Seal
HT, Tri-guilt Smooth HT S/A
Underlayment or Grip -Rite
Smooth Seal HT
Deck/
(Optional)ASTM
Plywood
D41
sheathing
ASTM 041
structural concrete
Col p hene FR GR 'self -
adheringSnck
Insulation
(Optional) Elastocol
Dens Deck Prime or SECUROCK Gypsum-
Zero
Fiber Roof Board
(Optional) Elastocol
ASTM D226, Type 11 felt or Modified Sopra-
Base Sheet
Stick Zero
G
I Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
REMO ETC, LLC Evaluation Report 519010.06.09-R19
CenlJrtarc ofAuthonn twn 832455 T"EDITION (20201 FBC NON-HVHZ EVALUATION FL2569-R21
Sopsema Roof Undeflayments Revision 19: 1Z/15/2020
Page S of 9
ONEMOIetc.
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Underlayment Appliratfon Substrates (designed to meet wind loads for project)
Type T Primer Materials)
Lastobond TU HT, Tri-Built S/A HT
TU Underlayment, RES15TO
LB1236, TRI-BUILT Sand-R SA Existing sand -surfaced, glass -fiber surfaced,
self- Existing RE5IS70 EXTERIOR
Shingle Underlayment, Grip -Rite adhering substrate PRIMER mineral -surfaced or film -surfaced roof
Eave &Valley Protector or underlayment* i
TopShield ICE & WATER
DEFENDER
' Final acceptance of any existing substrate in a reroof (rear -off) installation Is at the discretion of the installer and the Authority
Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive Lostobond TU HT, Tri-Built S/A HT
TU Underlayment, RESISTO L81236, TRI-BUILT Sand-R SA Shingle Underlayment Grip -Rite Eave & Valley Protector or TopShield ICE &
WATER DEFENDER self -adhering underlayments, contact RESISTO technical support.
5.7.1 Soprema recommends priming with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof
cover is not slated for installation within 24 hours.
5.7.2 Soprema requires tongue -and -groove board decking be covered with plywood or OSB prior to installation of the
self -adhering underlayment
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with
the manufacturer's installation instructions, but —for mechanically attached underlayments or base sheets - not
less than FBC 1507.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation
instructions, but— for mechanically attached base sheets - not less than:
• FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A,
Table 1 (for Two -Ply Asphalt Applied Hot Mop Underlayment)
or
• Section 5.8.3 herein (for other underlayment systems).
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI
Florida High Wind Concrete and Cloy Roof Tile Installation Manual, Sixth Edition. The Maximum Design Pressure
is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing
pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct -to -Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the
critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
#1 Maximum Design Pressure = -45.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional) Elastocol Stick, Elastocol Stick Zero or RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT, Tri-Built S/A HT TU Underlayment, self -adhered.
R2 Maximum Design Pressure = -67.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: Elastocol Stick Zero
Underlayment: Lastobond TU HT, Tri-Built S/A HT TU Underlayment, self -adhered.
NEMO ETC, LLC Evaluation Report S18010.06.09-R19
Ceaiflaate ofAurhonaebon a32455 7" EDITION(2020) FBC NON HVHZ EVALUATION FL2569-RZ1
Soprema Roof Underlaymenis Revision 19: 1Z/15/Z020
Page 6 of 9
ONEMOletc.
B3 Maximum Design Pressure = -120.0 psf:
Deck: Min. 15/32-inch APA-rated CDX plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer (Optional) RESISTO EXTERIOR PRIMER
Base Ply: RESISTO SA SMOOTH PLY 40, self -adhered.
Underlayment: Lastobond TU HT, Tri-Built S/A HT TU Underlayment, self -adhered.
p4 Maximum Design Pressure=-1SO.0 psf:
Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project requirements to
satisfaction of Authority Having Jurisdiction.
Primer: (Optional) RESISTO EXTERIOR PRIMER
Underlayment. Lastobond TU HT, Tri-Built S/A HT TU Underlayment, self -adhered.
k5 All other direct -deck, adhered underlayment systems beneath tile roof systems carry a Maximum Design
Pressure of -45 psf.
5.8.3.2 Mechanically -Attached Base Sheet.
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the
critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1
design pressure determined in accordance with FBC 1609or FBC Residential Chapter 3. Elevated pressure zones
shall employ an attachment density designed by a qualified design professional to resist the elevated pressure
criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application
Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk' carry the
limitations set forth in Section 2.2,10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for
enhancements.
R6 Maximum Design Pressure = -60.0 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction,
Base Sheet: Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC 1517.5.2) spaced 6-
inch o.c. at the 4-inch laps and 6-inch o.c. in three (3), equally spaced rows in the center of the sheet.
Underlayment: Lastobond TU HT, Tri-Built S/A HT TU Underlayment, self -adhered
5.8.4 For use over insulation or coverboard and under mechanically attached prepared roof coverings, underlayment
attachment shall be in accordance with the manufacturer's installation instructions and attachment of the
insulation or coverboard shall be in accordance with the prepared roof covering manufacturer's Product
Approval.
5.9 Exposure Limitations:
TABLE 3: EXPOSURE LIMITATIONS !
Prepared Roof Cover
Maximum
Underlayment
Installation Type
Exposure (days)
Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco, RESISTO LB1236, TRI-
Mechanically
!
BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector, TopShield ICE
30
& WATER DEFENDER or RESISTO LB1244
attached
Adhesive -se[ file roof
Lastobond TU HT, Tri-Built S/A HT TU Underlayment
30
system
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT,
Mechanically
Lastobond Pro HT-S, EnviroShield, Lastobond Smooth Seal HT, Tri-Built Smooth HT S/A
attached
90
Underlayment or Grip -Rite Smooth Seal HT
Lastobond TU HT, Tri-Built S/A HT TU Underlayment or Colphene FR GR
Mechanically
180
attached
NEMO ETC, LLC Evaluation Report 516010.06.09-1119
Certifmre ofAuteoraoton 4s2455 T"EDITION (2020)FBC NON-HVHZ EVALUATION FL2S69-R21
Soprema Roof Underlayment, Revision 19: 1Z/1S/Z020
Page 7 of 9
NNEMOletc.
5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the
maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during
loading of the roof tiles.
TAEia 4: TILE SUPPAOE LIMITAnONs FOR DIRECt-DECK TILE beTAUATMNS
Underlayment
Tile Profile
Stagklg M@Owd
Maximum Slope
Flat
Max. 10-tile stack
6:12
Lugged
Max. 10-tile stack
5:12
Lastobond TU HT. Tri-
Built S/A HT TU
Underlayment
Lugged
Max. 10-tile stack (bottom 2-tile stack shall be inverted,
followed by 8 tiles high on slope, as shown below)
6:12
Flat
Max. 10-tile stack
5:12
Colphene FR GR
Lugged
Max. 30-tile stack
6:12
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation instructions
subject to the Limitations set forth In Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application, and prime the substrate (if applicable).
6.2.1 Installation of RESISTO L81236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector or
TopShield ICE & WATER DEFENDER self -adhering underlayment in a reroof (tear -off) application atop an existing
underlayment (per Table 2) requires priming of the existing substrate with RESISTO EXTERIOR PRIMER. Final
acceptance of any existing substrate in a reroof (tear -off) installation is at the discretion of the installer and the
Authority Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive
RESISTO LB1236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector or TopShield ICE
& WATER DEFENDER self -adhering underlayments, contact RESISTO technical support.
6.3 Lastobond TU HT, Tri-Suitt S/A HT TU Underlayment, Lastobond Shield, Lastobond Pro HT-N, RESISTO SA
SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, EnviroShield, Lastobond Eaves Protection Sheet,
Lastobond 195, Lastobond Eco, Lastobond Smooth Seal HT, Tri-Built Smooth HT $/A Underlayment, Grip -Rite
Smooth Seal HT, RESISTO 1.81236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley
Protector, TopShield ICE & WATER DEFENDER, RESISTO L81244 or Colphene FR GR:
6.3.1 Non -Tile Applications:
Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering
to be installed, and the manufacturer's installation instructions.
When installed over a mechanically attached base sheet of F8C Approved ASTM D226, Type II felt the base sheet
shall be fastened in accordance with FBC 1507.1.1 or R905.1.1.
NEMO ETC, LLC Evaluation Report 518020.06.09-R39
Eenifirote ofAutMrvafm 132455 7'-EDITION 12020) FBC NON.HVHZ EVALUATION FL2569-R21
Soprema Root Underlayment; Revision 19: 12/16/2020
Page a of 9
ONEN401 etc.
6.3.2 Tile Applications:
Limited to Lastobond TU HT, Tri-Built S/A HT TU Underlayment or Colphene FR GR.
Shall be installed in compliance with the requirements for Self -Adhered Membrane set forth in FRSA/TRI Florida
High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition and the manufacturer's installation
Instructions.
Refer to Section 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for tile staging limitations.
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
Contact the named GA entity for manufacturing facilities covered by F.A.C. Rule 61G20.3 QA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
UL, LLC —
- END OF EVALUATION REPORT .
NEMO ETC, LUC Evaluation RePon $1801006.09-M119
Cenl/irnte of 4utMrllaran a32455 7'"EDITION 120201 FSC NON-NVN2 EVALUATION FL2569-1121
Soprerna Roof UnderlaynnentF Revhlon 19: 12/IS/2020
Page 9 of 9